Oliver F. Bischof
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Oliver F. Bischof has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
Torsten Tritscher
4 shared publicationsCarsten Kykal
TSI GmbH, Neuköllner Str. 4, 52068 Aachen, Germany
3 shared publications- Andrés Alastuey
Institute of Environmental Assessment and Water Research (IDAEA CSIC), Barcelona, Spain
2 shared publications Eric Filimundi
TSI France Incorporated, Technopôle de Château-Gombert, 13382 Marseille, France
2 shared publicationsHans-Georg Horn
2 shared publicationsHenna Tuomenoja
Dekati Ltd
2 shared publications
Latest Publications
- Open Access
- 25 February 2026
- Published by Swiss Chemical Society in Chimia
- Vol. 80 (1-2) , 13-20
Metrology of Nanoparticles
In the past decades, several measurement techniques have been developed and continuously optimized to specifically analyze airborne nanoparticles. Nanoparticles have gained significant importance in fields such as air quality research, climate studies, nanotechnology, material science, particle technology and filtration. Key measurement fundamentals for an accurate, reliable measurement of nanoparticles includes their sampling, conditioning, and analysis. We present a number of state-of-the-art aerosol measurement techniques, with a focus on condensation particle counters, mobility analyzers, and instruments based on the diffusion charging of particles. A brief overview of these methods is provided, with a special focus on work done in the framework of the ETH Nanoparticles Conference, which was originally founded to better understand and mitigate nanoparticles generated by vehicles and combustion processes.
- 25 February 2026
- Published by Swiss Chemical Society in Chimia
- Vol. 80 (1-2) , 13-20
Open AccessMetrology of Nanoparticles
In the past decades, several measurement techniques have been developed and continuously optimized to specifically analyze airborne nanoparticles. Nanoparticles have gained significant importance in fields such as air quality research, climate studies, nanotechnology, material science, particle technology and filtration. Key measurement fundamentals for an accurate, reliable measurement of nanoparticles includes their sampling, conditioning, and analysis. We present a number of state-of-the-art aerosol measurement techniques, with a focus on condensation particle counters, mobility analyzers, and instruments based on the diffusion charging of particles. A brief overview of these methods is provided, with a special focus on work done in the framework of the ETH Nanoparticles Conference, which was originally founded to better understand and mitigate nanoparticles generated by vehicles and combustion processes.
- 18 November 2019
- Published by Springer Nature in Emission Control Science and Technology
- Vol. 6 (1) , 37-46
Characterization of the Miniaturized Inverted Flame Burner as a Combustion Source to Generate a Nanoparticle Calibration Aerosol
- 18 November 2019
- Published by Springer Nature in Emission Control Science and Technology
- Vol. 6 (1) , 37-46
Characterization of the Miniaturized Inverted Flame Burner as a Combustion Source to Generate a Nanoparticle Calibration Aerosol
- Open Access
- 23 May 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 168, 09002
Solutions for the size & concentration measurement of aerosols from combustion
Currently the main pollution comes from the anthropogenic sources related to residential heating and combustion. Most of the emitted particles from this sources are in the mode below 1 μm. Therefore, only by using methods based on the electric mobility separation and size enhancement we can measure the size and concentration of this particles from nano to ultrafine sizes. This contribution describes the most recent methods how to study particle size and concentration of the particles coming from combustion sources.
- 23 May 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 168, 09002
Open AccessSolutions for the size & concentration measurement of aerosols from combustion
Currently the main pollution comes from the anthropogenic sources related to residential heating and combustion. Most of the emitted particles from this sources are in the mode below 1 μm. Therefore, only by using methods based on the electric mobility separation and size enhancement we can measure the size and concentration of this particles from nano to ultrafine sizes. This contribution describes the most recent methods how to study particle size and concentration of the particles coming from combustion sources.
- Open Access
- 1 April 2017
- Published by Elsevier in Science of The Total Environment
- Vol. 584-585, 849-855
Identification of technical problems affecting performance of DustTrak DRX aerosol monitors
- 1 April 2017
- Published by Elsevier in Science of The Total Environment
- Vol. 584-585, 849-855
Open AccessIdentification of technical problems affecting performance of DustTrak DRX aerosol monitors
- Open Access
- 7 April 2016
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 9 (4) , 1545-1551
Intercomparison of 15 aerodynamic particle size spectrometers (APS 3321): uncertainties in particle sizing and number size distribution
Aerodynamic particle size spectrometers are a well-established method to measure number size distributions of coarse mode particles in the atmosphere. Quality assurance is essential for atmospheric observational aerosol networks to obtain comparable results with known uncertainties. In a laboratory study within the framework of ACTRIS (Aerosols, Clouds, and Trace gases Research Infrastructure Network), 15 aerodynamic particle size spectrometers (APS model 3321, TSI Inc., St. Paul, MN, USA) were compared with a focus on flow rates, particle sizing, and the unit-to-unit variability of the particle number size distribution. Flow rate deviations were relatively small (within a few percent), while the sizing accuracy was found to be within 10 % compared to polystyrene latex (PSL) reference particles. The unit-to-unit variability in terms of the particle number size distribution during this study was within 10 % to 20 % for particles in the range of 0.9 up to 3 µm, which is acceptable for atmospheric measurements. For particles smaller than that, the variability increased up to 60 %, probably caused by differences in the counting efficiencies of individual units. Number size distribution data for particles smaller than 0.9 µm in aerodynamic diameter should only be used with caution. For particles larger than 3 µm, the unit-to-unit variability increased as well. A possible reason is an insufficient sizing accuracy in combination with a steeply sloping particle number size distribution and the increasing uncertainty due to decreasing counting. Particularly this uncertainty of the particle number size distribution must be considered if higher moments of the size distribution such as the particle volume or mass are calculated, which require the conversion of the aerodynamic diameter measured to a volume equivalent diameter. In order to perform a quantitative quality assurance, a traceable reference method for the particle number concentration in the size range 0.5–3 µm is needed.
- 7 April 2016
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 9 (4) , 1545-1551
Open AccessIntercomparison of 15 aerodynamic particle size spectrometers (APS 3321): uncertainties in particle sizing and number size distribution
Aerodynamic particle size spectrometers are a well-established method to measure number size distributions of coarse mode particles in the atmosphere. Quality assurance is essential for atmospheric observational aerosol networks to obtain comparable results with known uncertainties. In a laboratory study within the framework of ACTRIS (Aerosols, Clouds, and Trace gases Research Infrastructure Network), 15 aerodynamic particle size spectrometers (APS model 3321, TSI Inc., St. Paul, MN, USA) were compared with a focus on flow rates, particle sizing, and the unit-to-unit variability of the particle number size distribution. Flow rate deviations were relatively small (within a few percent), while the sizing accuracy was found to be within 10 % compared to polystyrene latex (PSL) reference particles. The unit-to-unit variability in terms of the particle number size distribution during this study was within 10 % to 20 % for particles in the range of 0.9 up to 3 µm, which is acceptable for atmospheric measurements. For particles smaller than that, the variability increased up to 60 %, probably caused by differences in the counting efficiencies of individual units. Number size distribution data for particles smaller than 0.9 µm in aerodynamic diameter should only be used with caution. For particles larger than 3 µm, the unit-to-unit variability increased as well. A possible reason is an insufficient sizing accuracy in combination with a steeply sloping particle number size distribution and the increasing uncertainty due to decreasing counting. Particularly this uncertainty of the particle number size distribution must be considered if higher moments of the size distribution such as the particle volume or mass are calculated, which require the conversion of the aerodynamic diameter measured to a volume equivalent diameter. In order to perform a quantitative quality assurance, a traceable reference method for the particle number concentration in the size range 0.5–3 µm is needed.
- 1 September 2015
- Published by Elsevier in Journal of Aerosol Science
- Vol. 87, 75-87
Fast and precise measurement in the sub-20nm size range using a Scanning Mobility Particle Sizer
- 1 September 2015
- Published by Elsevier in Journal of Aerosol Science
- Vol. 87, 75-87
Fast and precise measurement in the sub-20nm size range using a Scanning Mobility Particle Sizer
- Open Access
- 19 June 2015
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 49 (9) , 777-785
Intercomparisons of Mobility Size Spectrometers and Condensation Particle Counters in the Frame of the Spanish Atmospheric Observational Aerosol Network
Red Española de DMAs Ambientales (REDMAAS), the Spanish network of environmental differential mobility analyzers (DMAs), currently comprises six research groups involved in the measurement of atmospheric aerosol size distributions by means of DMAs. The aim of this network is to guarantee the good quality and comparability of the routine measurements carried out at each location and in diverse environments across Spain. In order to achieve this objective, one of its main activities is the annual intercomparison of mobility size spectrometers used within the network (five units of scanning mobility particle sizers [SMPS] and one ultrafine particle monitor [UFPM]). Here we report the 2main results obtained during the 2010–2012 campaigns, including a study on particle deposition in dryers used in ambient air sampling systems. In general, all instruments showed good performance with deviations in accepted tolerance. The intercomparisons have been proved to be a useful exercise to detect instrument problems, such as incorrect calibrations. DMA calibration checks were performed with polystyrene latex reference particles. Deviations of less than 1% were observed during the first year, which increased 4.7% during the last campaign. Some differences among the responses of different condensation particle counter (CPC) models were encountered, being mainly connected to the intrinsic characteristics of each counter. The comparison of UFPM with CPCs has given good results. The SMPS intercomparisons, especially for particles above 20 nm, have been within +/−15% tolerance. Regarding particle deposition in dryers used in sampling systems, particle penetration was lower than predicted by the recommended model. This result was probably due to the fact that not all the possible mechanisms were considered in the model. Copyright 2015 American Association for Aerosol Research
- 19 June 2015
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 49 (9) , 777-785
Open AccessIntercomparisons of Mobility Size Spectrometers and Condensation Particle Counters in the Frame of the Spanish Atmospheric Observational Aerosol Network
Red Española de DMAs Ambientales (REDMAAS), the Spanish network of environmental differential mobility analyzers (DMAs), currently comprises six research groups involved in the measurement of atmospheric aerosol size distributions by means of DMAs. The aim of this network is to guarantee the good quality and comparability of the routine measurements carried out at each location and in diverse environments across Spain. In order to achieve this objective, one of its main activities is the annual intercomparison of mobility size spectrometers used within the network (five units of scanning mobility particle sizers [SMPS] and one ultrafine particle monitor [UFPM]). Here we report the 2main results obtained during the 2010–2012 campaigns, including a study on particle deposition in dryers used in ambient air sampling systems. In general, all instruments showed good performance with deviations in accepted tolerance. The intercomparisons have been proved to be a useful exercise to detect instrument problems, such as incorrect calibrations. DMA calibration checks were performed with polystyrene latex reference particles. Deviations of less than 1% were observed during the first year, which increased 4.7% during the last campaign. Some differences among the responses of different condensation particle counter (CPC) models were encountered, being mainly connected to the intrinsic characteristics of each counter. The comparison of UFPM with CPCs has given good results. The SMPS intercomparisons, especially for particles above 20 nm, have been within +/−15% tolerance. Regarding particle deposition in dryers used in sampling systems, particle penetration was lower than predicted by the recommended model. This result was probably due to the fact that not all the possible mechanisms were considered in the model. Copyright 2015 American Association for Aerosol Research
- Open Access
- 26 May 2015
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 617 (1) , 012013
Multi-Instrument Manager Tool for Data Acquisition and Merging of Optical and Electrical Mobility Size Distributions
Electrical mobility classification (EC) followed by Condensation Particle Counter (CPC) detection is the technique combined in Scanning Mobility Particle Sizers(SMPS) to retrieve nanoparticle size distributions in the range from 2.5 nm to 1 μm. The detectable size range of SMPS systems can be extended by the addition of an Optical Particle Sizer(OPS) that covers larger sizes from 300 nm to 10 μm. This optical sizing method reports an optical equivalent diameter, which is often different from the electrical mobility diameter measured by the standard SMPS technique. Multi-Instrument Manager (MIMTM) software developed by TSI incorporates algorithms that facilitate merging SMPS data sets with data based on optical equivalent diameter to compile single, wide-range size distributions. Here we present MIM 2.0, the next-generation of the data merging tool that offers many advanced features for data merging and post-processing. MIM 2.0 allows direct data acquisition with OPS and NanoScan SMPS instruments to retrieve real-time particle size distributions from 10 nm to 10 μm, which we show in a case study at a fireplace. The merged data can be adjusted using one of the merging options, which automatically determines an overall aerosol effective refractive index. As a result an indirect and average characterization of aerosol optical and shape properties is possible. The merging tool allows several pre-settings, data averaging and adjustments, as well as the export of data sets and fitted graphs. MIM 2.0 also features several post-processing options for SMPS data and differences can be visualized in a multi-peak sample over a narrow size range.
- 26 May 2015
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 617 (1) , 012013
Open AccessMulti-Instrument Manager Tool for Data Acquisition and Merging of Optical and Electrical Mobility Size Distributions
Electrical mobility classification (EC) followed by Condensation Particle Counter (CPC) detection is the technique combined in Scanning Mobility Particle Sizers(SMPS) to retrieve nanoparticle size distributions in the range from 2.5 nm to 1 μm. The detectable size range of SMPS systems can be extended by the addition of an Optical Particle Sizer(OPS) that covers larger sizes from 300 nm to 10 μm. This optical sizing method reports an optical equivalent diameter, which is often different from the electrical mobility diameter measured by the standard SMPS technique. Multi-Instrument Manager (MIMTM) software developed by TSI incorporates algorithms that facilitate merging SMPS data sets with data based on optical equivalent diameter to compile single, wide-range size distributions. Here we present MIM 2.0, the next-generation of the data merging tool that offers many advanced features for data merging and post-processing. MIM 2.0 allows direct data acquisition with OPS and NanoScan SMPS instruments to retrieve real-time particle size distributions from 10 nm to 10 μm, which we show in a case study at a fireplace. The merged data can be adjusted using one of the merging options, which automatically determines an overall aerosol effective refractive index. As a result an indirect and average characterization of aerosol optical and shape properties is possible. The merging tool allows several pre-settings, data averaging and adjustments, as well as the export of data sets and fitted graphs. MIM 2.0 also features several post-processing options for SMPS data and differences can be visualized in a multi-peak sample over a narrow size range.
- Open Access
- 28 April 2015
- Published by Springer Nature in Emission Control Science and Technology
- Vol. 1 (2) , 203-212
Recent Developments in the Measurement of Low Particulate Emissions from Mobile Sources: A Review of Particle Number Legislations
- 28 April 2015
- Published by Springer Nature in Emission Control Science and Technology
- Vol. 1 (2) , 203-212
Open AccessRecent Developments in the Measurement of Low Particulate Emissions from Mobile Sources: A Review of Particle Number Legislations
- 10 April 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 429
NanoScan SMPS – A Novel, Portable Nanoparticle Sizing and Counting Instrument
- 10 April 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 429
NanoScan SMPS – A Novel, Portable Nanoparticle Sizing and Counting Instrument