Mohammad Mehdi Najafizadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohammad Mehdi Najafizadeh has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Mohsen Najarchi
Department of Civil Engineering, Arak Branch, Islamic Azad University, Arak, Iran
2 shared publications A. Sharifi
Department of Mechanical Engineering, Islamic Azad University, Arak Branch, Arak, I.R. Iran
1 shared publication- Abdorahim Jamal
Khatam-ol-Anbia Construction Headquarter, Taha Consulting Engineers, Tehran, Iran
1 shared publication - Abolghasem Sayadi
Department of Civil Engineering, Marv. C., Islamic Azad University, Marvdasht, Iran
1 shared publication - Ali Ghorbani1 shared publication
- Amin Joodaky
Islamic Azad University
1 shared publication
Latest Publications
- 12 December 2022
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 31 (5) , 1006-1020
Free vibration analysis of a porous functionally graded, truncated conical shell with a magneto-rheological fluid core
- 12 December 2022
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 31 (5) , 1006-1020
Free vibration analysis of a porous functionally graded, truncated conical shell with a magneto-rheological fluid core
- 4 May 2022
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 10 (4) , 1495-1509
Non-linear Free Vibration Analysis of a Thick Sandwich Panel with an Electrorheological Core
- 4 May 2022
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 10 (4) , 1495-1509
Non-linear Free Vibration Analysis of a Thick Sandwich Panel with an Electrorheological Core
- 1 October 2020
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Water Management
- Vol. 173 (5) , 238-248
Simulation and prediction of discharge coefficient of combined weir–gate structure
Combined weir–gate structures are important structures for controlling the water level, measuring discharge and avoiding sediment deposition behind a weir. They can be used, for example, in irrigation channels and waste water systems. Using three-dimensional numerical software (Flow-3D) and experimental data from the literature, four combined systems of a triangular weir and a rectangular gate with different geometries were simulated. Dimensional analyses were then performed to determine the dimensionless parameters that affect the discharge coefficient of such structures. Four different intelligent system models were used to estimate the discharge coefficient and their results were compared. It was found that Flow-3D is highly capable of simulating the flow over a combined structure. Goodness of fit criteria also showed that the numerical solver estimated the water head and discharge coefficient very well. The results of all the models showed that the discharge coefficient had an inverse relation with the dimensionless parameters h/b, h/d and h/y (h being the water head over the weir, b the gate width, d the gate height and y the distance between the bottom of the weir and above the gate); the discharge coefficients were 0·3–0·9. Accuracy analyses of six intelligent system models showed that the multi-layer perceptron model was the superior model, followed by the M5P model, the regression equation, the radial basis function and the generalised regression neural network model.
- 1 October 2020
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Water Management
- Vol. 173 (5) , 238-248
Simulation and prediction of discharge coefficient of combined weir–gate structure
Combined weir–gate structures are important structures for controlling the water level, measuring discharge and avoiding sediment deposition behind a weir. They can be used, for example, in irrigation channels and waste water systems. Using three-dimensional numerical software (Flow-3D) and experimental data from the literature, four combined systems of a triangular weir and a rectangular gate with different geometries were simulated. Dimensional analyses were then performed to determine the dimensionless parameters that affect the discharge coefficient of such structures. Four different intelligent system models were used to estimate the discharge coefficient and their results were compared. It was found that Flow-3D is highly capable of simulating the flow over a combined structure. Goodness of fit criteria also showed that the numerical solver estimated the water head and discharge coefficient very well. The results of all the models showed that the discharge coefficient had an inverse relation with the dimensionless parameters h/b, h/d and h/y (h being the water head over the weir, b the gate width, d the gate height and y the distance between the bottom of the weir and above the gate); the discharge coefficients were 0·3–0·9. Accuracy analyses of six intelligent system models showed that the multi-layer perceptron model was the superior model, followed by the M5P model, the regression equation, the radial basis function and the generalised regression neural network model.
- Open Access
- 11 March 2019
- Published by Wiley in Advances in Meteorology
- Vol. 2019, 1-16
Investigation into the Effects of Climatic Change on Temperature, Rainfall, and Runoff of the Doroudzan Catchment, Iran, Using the Ensemble Approach of CMIP3 Climate Models
This study investigated the effects of climatic changes on temperature, rainfall, and runoff in the Doroudzan catchment in the northeast of Fars province, Iran. Temperature and rainfall changes in three periods including 2011–2030, 2046–2065, and 2080–2099 were downscaled and studied using 15 Coupled Model Intercomparison Project, Phase 3 (CMIP3) climatic models, under three scenarios of greenhouse gas emissions A2, B1, and A1B, from the database of the LARS-WG model. The difference in the amount of changes in temperature and rainfall in these three periods and the observational amounts under the 15 models indicated the uncertainty of the changes values. To reduce this uncertainty and limit the results to the management and planning of water resources, ensemble approach was considered. For the preparation of the ensemble approach, the parameters from the files of the 15-model scenarios were averaged so that a climatic ensemble model could be obtained for each period. Then, the runoffs of the next three periods, under the second approach and three emission scenarios, were produced using the feedforwad neural network. The results indicated an increase in the average monthly maximum temperature and the minimum temperature in all three periods under the three scenarios. The results also showed a decrease in the rainfall in the early months of the year as well as an increase in the rainfall in the spring in most scenarios. Generally, the average annual rainfall in all these three periods under the climatic ensemble model, and three emission scenarios showed a reduction in the average annual rainfall in the three periods. The maximum amount of reduction was in 2080–2099 (101 mm) under the scenario B1. Besides, a reduction occurred in the average runoff of the catchment under three ensemble models and the emission scenario in all three periods, as compared to the average of the long-term observational values in most years.
- 11 March 2019
- Published by Wiley in Advances in Meteorology
- Vol. 2019, 1-16
Open AccessInvestigation into the Effects of Climatic Change on Temperature, Rainfall, and Runoff of the Doroudzan Catchment, Iran, Using the Ensemble Approach of CMIP3 Climate Models
This study investigated the effects of climatic changes on temperature, rainfall, and runoff in the Doroudzan catchment in the northeast of Fars province, Iran. Temperature and rainfall changes in three periods including 2011–2030, 2046–2065, and 2080–2099 were downscaled and studied using 15 Coupled Model Intercomparison Project, Phase 3 (CMIP3) climatic models, under three scenarios of greenhouse gas emissions A2, B1, and A1B, from the database of the LARS-WG model. The difference in the amount of changes in temperature and rainfall in these three periods and the observational amounts under the 15 models indicated the uncertainty of the changes values. To reduce this uncertainty and limit the results to the management and planning of water resources, ensemble approach was considered. For the preparation of the ensemble approach, the parameters from the files of the 15-model scenarios were averaged so that a climatic ensemble model could be obtained for each period. Then, the runoffs of the next three periods, under the second approach and three emission scenarios, were produced using the feedforwad neural network. The results indicated an increase in the average monthly maximum temperature and the minimum temperature in all three periods under the three scenarios. The results also showed a decrease in the rainfall in the early months of the year as well as an increase in the rainfall in the spring in most scenarios. Generally, the average annual rainfall in all these three periods under the climatic ensemble model, and three emission scenarios showed a reduction in the average annual rainfall in the three periods. The maximum amount of reduction was in 2080–2099 (101 mm) under the scenario B1. Besides, a reduction occurred in the average runoff of the catchment under three ensemble models and the emission scenario in all three periods, as compared to the average of the long-term observational values in most years.
- Open Access
- 15 February 2017
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 19 (1) , 394-408
Evaluation of brick infill walls under in-plane and out-of-plane loading
In this paper, the in-plane (IP) and out-of-plane (OP) interaction of masonry infill walls with various length-to-height ratios and vertical forces from dead and live loads are studied. For this purpose, calibrated numerical simulation for IP and OP behaviors of infilled frames has been exploited. In this method, first, the vertical loads are applied, then increasing IP displacement is imposed at the top of the models and finally OP demands are applied to the walls up to their failure. Two different methods of applying OP loading are studied: increasing static uniform pressure on the wall, and increasing dynamic acceleration. Three levels of IP displacement demands are considered: at the first reduction of tangential stiffness for IP force-displacement response, at the maximum IP strength, and at the displacement related to 20 % reduction of IP strength. The results obviously show that up to the point of the maximum IP strength capacity, the OP behavior of the considered models slightly enhanced due to the effects of improved arching actions originated from the development of IP compressive diagonal struts. Moreover, slight differences exist between the static and dynamic loadings in OP direction, hence proving the accuracy of the equivalent static loading in determining OP capacity for the studied infilled frames. Comparing the results of masonry infilled frames with those of the corresponding masonry walls indicate that the IP displacements negatively affect the OP strength in the latter, even at small IP displacement demands; however, the rate of OP strength reduction in larger IP drift ratios is lower compared to that of the corresponding infilled frame.
- 15 February 2017
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 19 (1) , 394-408
Open AccessEvaluation of brick infill walls under in-plane and out-of-plane loading
In this paper, the in-plane (IP) and out-of-plane (OP) interaction of masonry infill walls with various length-to-height ratios and vertical forces from dead and live loads are studied. For this purpose, calibrated numerical simulation for IP and OP behaviors of infilled frames has been exploited. In this method, first, the vertical loads are applied, then increasing IP displacement is imposed at the top of the models and finally OP demands are applied to the walls up to their failure. Two different methods of applying OP loading are studied: increasing static uniform pressure on the wall, and increasing dynamic acceleration. Three levels of IP displacement demands are considered: at the first reduction of tangential stiffness for IP force-displacement response, at the maximum IP strength, and at the displacement related to 20 % reduction of IP strength. The results obviously show that up to the point of the maximum IP strength capacity, the OP behavior of the considered models slightly enhanced due to the effects of improved arching actions originated from the development of IP compressive diagonal struts. Moreover, slight differences exist between the static and dynamic loadings in OP direction, hence proving the accuracy of the equivalent static loading in determining OP capacity for the studied infilled frames. Comparing the results of masonry infilled frames with those of the corresponding masonry walls indicate that the IP displacements negatively affect the OP strength in the latter, even at small IP displacement demands; however, the rate of OP strength reduction in larger IP drift ratios is lower compared to that of the corresponding infilled frame.
- 14 July 2016
- Published by University of Liege in Bulletin de la Société Royale des Sciences de Liège
- p. 721-728
A Theoretical and Experimental Analysis of Critical Buckling Force of Short and Long Cylindrical Shells with a Welded Seam Using Argon
In this paper, seaming and seamless as well as short and long cylindrical shell buckling of aluminum 6063 which is under axial loading is taken into account. The used parts have equal mass and thickness and the seam is filled with argon method. An experimental test has been done bySANTAM-STM-250 device. Numerical analysis has been conducted by Abaqus Software, and precision of these models is measured by experimental results.
- 14 July 2016
- Published by University of Liege in Bulletin de la Société Royale des Sciences de Liège
- p. 721-728
A Theoretical and Experimental Analysis of Critical Buckling Force of Short and Long Cylindrical Shells with a Welded Seam Using Argon
In this paper, seaming and seamless as well as short and long cylindrical shell buckling of aluminum 6063 which is under axial loading is taken into account. The used parts have equal mass and thickness and the seam is filled with argon method. An experimental test has been done bySANTAM-STM-250 device. Numerical analysis has been conducted by Abaqus Software, and precision of these models is measured by experimental results.
- Open Access
- 1 January 2016
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 10 (31) , 1-7
DESIGNING HYDRAULIC AIR CHAMBER IN WATER TRANSMISSION SYSTEMS USING GENETIC ALGORITHM
Transient flow control in Water Transmission Systems (WTS) is one of the requirements of designing these systems. Hence, among control equipment, air chambers offer the best solution to control transient flow effects, i.e. both prevents water column separation and absorbs pressure increase. It is...
- 1 January 2016
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 10 (31) , 1-7
Open AccessDESIGNING HYDRAULIC AIR CHAMBER IN WATER TRANSMISSION SYSTEMS USING GENETIC ALGORITHM
Transient flow control in Water Transmission Systems (WTS) is one of the requirements of designing these systems. Hence, among control equipment, air chambers offer the best solution to control transient flow effects, i.e. both prevents water column separation and absorbs pressure increase. It is...
- 1 January 2014
- Published by Springer Nature
- p. 2236-2243
Higher Order Thermal Buckling of Circular Plates
- 1 January 2014
- Published by Springer Nature
- p. 2236-2243
Higher Order Thermal Buckling of Circular Plates
- Open Access
- 16 October 2012
- Published by Oxford University Press (OUP) in Journal of Mechanics
- Vol. 29 (1) , 157-167
Thermal Buckling Analysis of Circular FGP with Actuator/Actuator Piezoelectric Layers Based on Neutral Plane Method
In this research, thermal buckling analysis of circular functionally graded plates with Actuator/Actuator piezoelectric layers (FGPs) is studied based on neutral plane, classical and first order shear deformation plate theories. Mechanical properties of the plate are considered as those of Reddy Model. Plate is assumed to be under thermal loading. Nonlinear temperature rises through the thickness and boundary conditions are considered clamped. Equilibrium and stability equations have been derived using calculus of variations and application of Euler equations. Finally, critical buckling temperature changes are studied based on the mentioned theories for a sample plate. An appropriate agreement is seen among the present results and the results of other researches.
- 16 October 2012
- Published by Oxford University Press (OUP) in Journal of Mechanics
- Vol. 29 (1) , 157-167
Open AccessThermal Buckling Analysis of Circular FGP with Actuator/Actuator Piezoelectric Layers Based on Neutral Plane Method
In this research, thermal buckling analysis of circular functionally graded plates with Actuator/Actuator piezoelectric layers (FGPs) is studied based on neutral plane, classical and first order shear deformation plate theories. Mechanical properties of the plate are considered as those of Reddy Model. Plate is assumed to be under thermal loading. Nonlinear temperature rises through the thickness and boundary conditions are considered clamped. Equilibrium and stability equations have been derived using calculus of variations and application of Euler equations. Finally, critical buckling temperature changes are studied based on the mentioned theories for a sample plate. An appropriate agreement is seen among the present results and the results of other researches.