Saverio Affatato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Saverio Affatato has a total of 345 co-authors. Here are the top co-authors by number of shared publications:
- Paola Taddei
Biochemistry Unit, Department of Biomedical and Neuromotor Sciences, University of Bologna, Via Irnerio 48, 40126 Bologna, Italy
40 shared publications - Marco Viceconti
Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy
20 shared publications A. Toni
19 shared publications- Alessandro Ruggiero
University of Salerno
19 shared publications - Michele Spinelli
Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
17 shared publications - Simone Carmignato
Department of Management and Engineering, University of Padova, 36100 Vicenza, Italy
13 shared publications
Latest Publications
- 7 May 2022
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 110 (10) , 2299-2309
To what extent could the acetabular liner thickness be reduced yet remaining tribologically acceptable in metal‐on‐vitamin E‐diffused crosslinked polyethylene hip arthroplasty?
The aim of the present study was to evaluate how much reduction in acetabular liner thickness could be tribologically acceptable in metal‐on‐vitamin‐E diffused highly crosslinked ultra‐high molecular weight polyethylene (Vit‐E XLPE) bearings for total hip arthroplasty. We tested thick‐ (10.3 mm), moderate‐ (6.3 mm), and thin‐ (4.3 mm) Vit‐E XLPE liners coupled with 28‐mm cobalt‐chromium femoral heads on a hip simulator to 5 million cycles, and peak contact stress was predicted based on mathematical modeling. Wear damage was also evaluated in terms of surface topology and morphology. Wear simulation demonstrated that the 2–4 mm thickness reduction (6.3 → 4.3 mm and 10.3 → 6.3 mm) did not significantly affect the wear rate for Vit‐E XLPE liner, whereas 6‐mm reduction (10.3 → 4.3 mm) significantly increased liner wear (by 309%) and head roughness (by 415%). This effect was attributed to a contact stress increase (by 24–41%). However, the wear rates for all thicknesses tested were much lower than those previously reported for thicker non‐crosslinked materials. The original crystalline morphology was maintained in all liners after wear. Our results suggest that the 2–4 mm thickness reduction may be tribologically acceptable in Vit‐E XLPE liners. However, more severe and longer term simulations are necessary to determine a minimum acceptable thickness.
- 7 May 2022
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 110 (10) , 2299-2309
To what extent could the acetabular liner thickness be reduced yet remaining tribologically acceptable in metal‐on‐vitamin E‐diffused crosslinked polyethylene hip arthroplasty?
The aim of the present study was to evaluate how much reduction in acetabular liner thickness could be tribologically acceptable in metal‐on‐vitamin‐E diffused highly crosslinked ultra‐high molecular weight polyethylene (Vit‐E XLPE) bearings for total hip arthroplasty. We tested thick‐ (10.3 mm), moderate‐ (6.3 mm), and thin‐ (4.3 mm) Vit‐E XLPE liners coupled with 28‐mm cobalt‐chromium femoral heads on a hip simulator to 5 million cycles, and peak contact stress was predicted based on mathematical modeling. Wear damage was also evaluated in terms of surface topology and morphology. Wear simulation demonstrated that the 2–4 mm thickness reduction (6.3 → 4.3 mm and 10.3 → 6.3 mm) did not significantly affect the wear rate for Vit‐E XLPE liner, whereas 6‐mm reduction (10.3 → 4.3 mm) significantly increased liner wear (by 309%) and head roughness (by 415%). This effect was attributed to a contact stress increase (by 24–41%). However, the wear rates for all thicknesses tested were much lower than those previously reported for thicker non‐crosslinked materials. The original crystalline morphology was maintained in all liners after wear. Our results suggest that the 2–4 mm thickness reduction may be tribologically acceptable in Vit‐E XLPE liners. However, more severe and longer term simulations are necessary to determine a minimum acceptable thickness.
- Open Access
- 26 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (23) , 11224
Roughness Digital Characterization and Influence on Wear of Retrieved Knee Components
Tribological performance of knee components are strongly related to the surface characteristics. Primarily, the roughness and its 3D distribution on the surfaces affect the joint performance. One of the main limitations related to the tribological study of knee prostheses is that most of the research studies report in vitro or in silico results, as knee retrievals are difficult to find or are too damaged to be analyzed. This paper is focused on the roughness characterization of retrieved metal femoral components of total knee replacements (TKR) by means of a rugosimeter and involving digital methods to reconstruct the 3D topography of the studied surfaces. The aim of this study is to investigate how changes and distribution of roughness are correlated between the medial vs. the lateral part and how the resulting digital topography can give insights about the wear behavior.
- 26 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (23) , 11224
Open AccessRoughness Digital Characterization and Influence on Wear of Retrieved Knee Components
Tribological performance of knee components are strongly related to the surface characteristics. Primarily, the roughness and its 3D distribution on the surfaces affect the joint performance. One of the main limitations related to the tribological study of knee prostheses is that most of the research studies report in vitro or in silico results, as knee retrievals are difficult to find or are too damaged to be analyzed. This paper is focused on the roughness characterization of retrieved metal femoral components of total knee replacements (TKR) by means of a rugosimeter and involving digital methods to reconstruct the 3D topography of the studied surfaces. The aim of this study is to investigate how changes and distribution of roughness are correlated between the medial vs. the lateral part and how the resulting digital topography can give insights about the wear behavior.
- Open Access
- 21 June 2021
- Published by Wiley in Artificial Organs
- Vol. 46 (5) , 804-812
Dual mobility cup in hip arthroplasty: An in‐depth analysis of joint registries
Although total hip arthroplasty (THA) has shown successful results, instability remains a major complication. In recent years, dual mobility cups (DMC) have gained interest among clinicians thanks to its low rate of dislocation and good clinical results. The main aim of this work was to describe the accuracy of data on DMC from national and regional joint registries (JRs) and the available worldwide literature. We identified topics on DMC among JRs to propose a new harmonized and standardized section for DMC with the aim to understand its surveillance over the time. We extracted survival and implant data for a separate analysis. After performing a critical exclusion process, nine JRs were considered eligible and included for final synthesis; these were the results from the available worldwide data from JRs. In our study, eight analyzed JRs reported a slight increase in DMC use in the last decade. In all the JRs evaluated and the available articles, dislocation remains one of the main reasons for revision and re‐revision in hip arthroplasties. DMC is considered to be a valid construct increasingly used worldwide in primary and revision THA with the primary aim of reducing dislocation rates. Annual reports from JRs collect heterogeneous and low‐quality information about outcomes and surveillance of DMC, creating a burden for clinicians to extract comparable data from different JRs. Longer follow‐up and a systematic registering of DMCs with international registry harmonization are needed to monitor DMC outcomes.
- 21 June 2021
- Published by Wiley in Artificial Organs
- Vol. 46 (5) , 804-812
Open AccessDual mobility cup in hip arthroplasty: An in‐depth analysis of joint registries
Although total hip arthroplasty (THA) has shown successful results, instability remains a major complication. In recent years, dual mobility cups (DMC) have gained interest among clinicians thanks to its low rate of dislocation and good clinical results. The main aim of this work was to describe the accuracy of data on DMC from national and regional joint registries (JRs) and the available worldwide literature. We identified topics on DMC among JRs to propose a new harmonized and standardized section for DMC with the aim to understand its surveillance over the time. We extracted survival and implant data for a separate analysis. After performing a critical exclusion process, nine JRs were considered eligible and included for final synthesis; these were the results from the available worldwide data from JRs. In our study, eight analyzed JRs reported a slight increase in DMC use in the last decade. In all the JRs evaluated and the available articles, dislocation remains one of the main reasons for revision and re‐revision in hip arthroplasties. DMC is considered to be a valid construct increasingly used worldwide in primary and revision THA with the primary aim of reducing dislocation rates. Annual reports from JRs collect heterogeneous and low‐quality information about outcomes and surveillance of DMC, creating a burden for clinicians to extract comparable data from different JRs. Longer follow‐up and a systematic registering of DMCs with international registry harmonization are needed to monitor DMC outcomes.
- Open Access
Preliminary In Vitro Wear Assessment of Ceramic Cemented Femoral Components Coupled with Polyethylene Menisci
Success of total knee replacement (TKR) depends on the prosthetic design and materials. The use of metal components is well established with the disadvantage of allergic reactions. Ceramics have been recently proposed because of high wear resistance, excellent biocompatibility, wettability, and suitable mechanical properties. This study was aimed at investigating in vitro wear resistance of Zirconia Toughened Alumina (ZTA)/Ultra-high-molecular-weight polyethylene (UHMWPE) of TKR femoral components. An in vitro protocol was designed with the application of relevant load profile, 6-degrees-of-freedom knee simulator, and 8 × 105 cycles on the ZTA/UHMWPE configuration under bovine calf serum. Before and after wear test, the femoral components were investigated by using the Scanning Electron Microscope (SEM) and the X-Ray Diffraction (XRD) analyses, and stylus surface roughness measurements. The proposed pre-clinical test yielded repeatable results. In particular, gravimetric results showed that, after 8 × 105 cycles, the mean weight loss of the polyethylene mobile components is 5.3 ± 1.1 mg. The surface roughness measurements (Ramax) performed after the wear test showed no significant variation on the UHMWPE menisci. A slight increase of roughness has been found on the ZTA (0.02 µm before wear test, 0.28 µm after the test). SEM observations did not show significant modification of the surface morphology. Tetragonal to monoclinic phase ratio was measured by XRD before and after wear test to evaluate stability of tetragonal ZrO2 phase. Minimal conversion of tetragonal to monoclinic phase was found from 5.4 to 8%. Although this study is a preliminary evaluation limited to in vitro tests, it provides novel pre-clinical indications about the potential of ceramic TKR femoral components.
Open AccessPreliminary In Vitro Wear Assessment of Ceramic Cemented Femoral Components Coupled with Polyethylene Menisci
Success of total knee replacement (TKR) depends on the prosthetic design and materials. The use of metal components is well established with the disadvantage of allergic reactions. Ceramics have been recently proposed because of high wear resistance, excellent biocompatibility, wettability, and suitable mechanical properties. This study was aimed at investigating in vitro wear resistance of Zirconia Toughened Alumina (ZTA)/Ultra-high-molecular-weight polyethylene (UHMWPE) of TKR femoral components. An in vitro protocol was designed with the application of relevant load profile, 6-degrees-of-freedom knee simulator, and 8 × 105 cycles on the ZTA/UHMWPE configuration under bovine calf serum. Before and after wear test, the femoral components were investigated by using the Scanning Electron Microscope (SEM) and the X-Ray Diffraction (XRD) analyses, and stylus surface roughness measurements. The proposed pre-clinical test yielded repeatable results. In particular, gravimetric results showed that, after 8 × 105 cycles, the mean weight loss of the polyethylene mobile components is 5.3 ± 1.1 mg. The surface roughness measurements (Ramax) performed after the wear test showed no significant variation on the UHMWPE menisci. A slight increase of roughness has been found on the ZTA (0.02 µm before wear test, 0.28 µm after the test). SEM observations did not show significant modification of the surface morphology. Tetragonal to monoclinic phase ratio was measured by XRD before and after wear test to evaluate stability of tetragonal ZrO2 phase. Minimal conversion of tetragonal to monoclinic phase was found from 5.4 to 8%. Although this study is a preliminary evaluation limited to in vitro tests, it provides novel pre-clinical indications about the potential of ceramic TKR femoral components.
- Open Access
- 7 April 2021
- Published by Wiley in Advanced Healthcare Materials
- Vol. 10 (7) , 2170029
Cartilage Substitutes: Graphene Oxide‐Doped Gellan Gum–PEGDA Bilayered Hydrogel Mimicking the Mechanical and Lubrication Properties of Articular Cartilage (Adv. Healthcare Mater. 7/2021)
- 7 April 2021
- Published by Wiley in Advanced Healthcare Materials
- Vol. 10 (7) , 2170029
Open AccessCartilage Substitutes: Graphene Oxide‐Doped Gellan Gum–PEGDA Bilayered Hydrogel Mimicking the Mechanical and Lubrication Properties of Articular Cartilage (Adv. Healthcare Mater. 7/2021)
- Open Access
- 15 February 2021
- Published by Wiley in Advanced Healthcare Materials
- Vol. 10 (7) , 2001434
Graphene Oxide‐Doped Gellan Gum–PEGDA Bilayered Hydrogel Mimicking the Mechanical and Lubrication Properties of Articular Cartilage
Articular cartilage (AC) is a specialized connective tissue able to provide a low‐friction gliding surface supporting shock‐absorption, reducing stresses, and guaranteeing wear‐resistance thanks to its structure and mechanical and lubrication properties. Being an avascular tissue, AC has a limited ability to heal defects. Nowadays, conventional strategies show several limitations, which results in ineffective restoration of chondral defects. Several tissue engineering approaches have been proposed to restore the AC's native properties without reproducing its mechanical and lubrication properties yet. This work reports the fabrication of a bilayered structure made of gellan gum (GG) and poly (ethylene glycol) diacrylate (PEGDA), able to mimic the mechanical and lubrication features of both AC superficial and deep zones. Through appropriate combinations of GG and PEGDA, cartilage Young's modulus is effectively mimicked for both zones. Graphene oxide is used as a dopant agent for the superficial hydrogel layer, demonstrating a lower friction than the nondoped counterpart. The bilayered hydrogel's antiwear properties are confirmed by using a knee simulator, following ISO 14243. Finally, in vitro tests with human chondrocytes confirm the absence of cytotoxicity effects. The results shown in this paper open the way to a multilayered synthetic injectable or surgically implantable filler for restoring AC defects.
- 15 February 2021
- Published by Wiley in Advanced Healthcare Materials
- Vol. 10 (7) , 2001434
Open AccessGraphene Oxide‐Doped Gellan Gum–PEGDA Bilayered Hydrogel Mimicking the Mechanical and Lubrication Properties of Articular Cartilage
Articular cartilage (AC) is a specialized connective tissue able to provide a low‐friction gliding surface supporting shock‐absorption, reducing stresses, and guaranteeing wear‐resistance thanks to its structure and mechanical and lubrication properties. Being an avascular tissue, AC has a limited ability to heal defects. Nowadays, conventional strategies show several limitations, which results in ineffective restoration of chondral defects. Several tissue engineering approaches have been proposed to restore the AC's native properties without reproducing its mechanical and lubrication properties yet. This work reports the fabrication of a bilayered structure made of gellan gum (GG) and poly (ethylene glycol) diacrylate (PEGDA), able to mimic the mechanical and lubrication features of both AC superficial and deep zones. Through appropriate combinations of GG and PEGDA, cartilage Young's modulus is effectively mimicked for both zones. Graphene oxide is used as a dopant agent for the superficial hydrogel layer, demonstrating a lower friction than the nondoped counterpart. The bilayered hydrogel's antiwear properties are confirmed by using a knee simulator, following ISO 14243. Finally, in vitro tests with human chondrocytes confirm the absence of cytotoxicity effects. The results shown in this paper open the way to a multilayered synthetic injectable or surgically implantable filler for restoring AC defects.
- Open Access
Wear Behavior Characterization of Hydrogels Constructs for Cartilage Tissue Replacement
This paper aims to characterize the wear behavior of hydrogel constructs designed for human articular cartilage replacement. To this purpose, poly (ethylene glycol) diacrylate (PEGDA) 10% w/v and gellan gum (GG) 1.5% w/v were used to reproduce the superior (SUP) cartilage layer and PEGDA 15% w/v and GG 1.5% w/v were used to reproduce the deep (DEEP) cartilage layer, with or without graphene oxide (GO). These materials (SUP and DEEP) were analyzed alone and in combination to mimic the zonal architecture of human articular cartilage. The developed constructs were tested using a four-station displacement control knee joint simulator under bovine calf serum. Roughness and micro-computer tomography (µ-CT) measurements evidenced that the hydrogels with 10% w/v of PEGDA showed a worse behavior both in terms of roughness increase and loss of uniformly distributed density than 15% w/v of PEGDA. The simultaneous presence of GO and 15% w/v PEGDA contributed to keeping the hydrogel construct’s characteristics. The Raman spectra of the control samples showed the presence of unreacted C=C bonds in all the hydrogels. The degree of crosslinking increased along the series SUP < DEEP + SUP < DEEP without GO. The Raman spectra of the tested hydrogels showed the loss of diacrylate groups in all the samples, due to the washout of unreacted PEGDA in bovine calf serum aqueous environment. The loss decreased along the series SUP > DEEP + SUP > DEEP, further confirming that the degree of photo-crosslinking of the starting materials plays a key role in determining their wear behavior. μ-CT and Raman spectroscopy proved to be suitable techniques to characterize the structure and composition of hydrogels.
Open AccessWear Behavior Characterization of Hydrogels Constructs for Cartilage Tissue Replacement
This paper aims to characterize the wear behavior of hydrogel constructs designed for human articular cartilage replacement. To this purpose, poly (ethylene glycol) diacrylate (PEGDA) 10% w/v and gellan gum (GG) 1.5% w/v were used to reproduce the superior (SUP) cartilage layer and PEGDA 15% w/v and GG 1.5% w/v were used to reproduce the deep (DEEP) cartilage layer, with or without graphene oxide (GO). These materials (SUP and DEEP) were analyzed alone and in combination to mimic the zonal architecture of human articular cartilage. The developed constructs were tested using a four-station displacement control knee joint simulator under bovine calf serum. Roughness and micro-computer tomography (µ-CT) measurements evidenced that the hydrogels with 10% w/v of PEGDA showed a worse behavior both in terms of roughness increase and loss of uniformly distributed density than 15% w/v of PEGDA. The simultaneous presence of GO and 15% w/v PEGDA contributed to keeping the hydrogel construct’s characteristics. The Raman spectra of the control samples showed the presence of unreacted C=C bonds in all the hydrogels. The degree of crosslinking increased along the series SUP < DEEP + SUP < DEEP without GO. The Raman spectra of the tested hydrogels showed the loss of diacrylate groups in all the samples, due to the washout of unreacted PEGDA in bovine calf serum aqueous environment. The loss decreased along the series SUP > DEEP + SUP > DEEP, further confirming that the degree of photo-crosslinking of the starting materials plays a key role in determining their wear behavior. μ-CT and Raman spectroscopy proved to be suitable techniques to characterize the structure and composition of hydrogels.
- Open Access
- 14 December 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (24) , 8919
Biotribology in Arthroplasty: Worn Surfaces Investigation on Ceramic Hip Femoral Heads Considering Wettability
Ceramic-on-ceramic bearings for total hip replacement are considered the best choice to avoid problems such as osteolysis and wear, mainly related to soft bearings. The aim of this work was to investigate in a comparative way different kinds of ceramic femoral heads for total hip replacements from a biotribological point of view, discussing the results obtained in terms of topographies, presence of metal transfer (MT) phenomena, and wettability on their worn surfaces in a tribological framework. Different ceramic femoral heads derived from in vitro wear tests, retrieved form patients, and brand new total hip replacements were investigated. The patients group had an average age of 60 years (ranging from 27 to 83). In most cases, the cause of failure was aseptic loosening of the acetabular component. Roughness analyses were performed to measure the tribological surface evolution of the material; an SEM and EDS investigation on the explanted heads proves and quantified MT, while the wettability was measured through a novel optical laboratory set-up with the aim to furnish useful data in the framework of synovial lubrication phenomena acting in the tribosystem. For the average roughness measurements on explanted specimens were considered three parameters (Ra = the average area between the roughness profile and its mean line; Rt = the vertical distance from the deepest valley to the highest peak of the roughness profile; and Rsk = it is the skewness and it is a measure of the asymmetry of the amplitude distribution function. In other words, the skewness indicates whether a surface is dominated by peaks or by valleys) and their values were: Ra 0.22 ± 0.12 μm, Rt 34.5 ± 13.5 μm and Rsk −0.01 ± 11.3; on the new specimens we measured Ra 0.01 ± 0.001 μm, Rt 0.12 ± 0.09 μm, and Rsk = 5.67 ± 8.7; for the in vitro specimens they were Ra 0.05 ± 0.12 μm, Rt 0.71 ± 1.4 μm and Rsk 7.73 ± 20.6. The wettability angle measurements showed hydrophilic surfaces for all femoral heads considered in this study with small differences between the three investigated categories, allowing to discuss their effects on the biobearings’ lubrication phenomena.
- 14 December 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (24) , 8919
Open AccessBiotribology in Arthroplasty: Worn Surfaces Investigation on Ceramic Hip Femoral Heads Considering Wettability
Ceramic-on-ceramic bearings for total hip replacement are considered the best choice to avoid problems such as osteolysis and wear, mainly related to soft bearings. The aim of this work was to investigate in a comparative way different kinds of ceramic femoral heads for total hip replacements from a biotribological point of view, discussing the results obtained in terms of topographies, presence of metal transfer (MT) phenomena, and wettability on their worn surfaces in a tribological framework. Different ceramic femoral heads derived from in vitro wear tests, retrieved form patients, and brand new total hip replacements were investigated. The patients group had an average age of 60 years (ranging from 27 to 83). In most cases, the cause of failure was aseptic loosening of the acetabular component. Roughness analyses were performed to measure the tribological surface evolution of the material; an SEM and EDS investigation on the explanted heads proves and quantified MT, while the wettability was measured through a novel optical laboratory set-up with the aim to furnish useful data in the framework of synovial lubrication phenomena acting in the tribosystem. For the average roughness measurements on explanted specimens were considered three parameters (Ra = the average area between the roughness profile and its mean line; Rt = the vertical distance from the deepest valley to the highest peak of the roughness profile; and Rsk = it is the skewness and it is a measure of the asymmetry of the amplitude distribution function. In other words, the skewness indicates whether a surface is dominated by peaks or by valleys) and their values were: Ra 0.22 ± 0.12 μm, Rt 34.5 ± 13.5 μm and Rsk −0.01 ± 11.3; on the new specimens we measured Ra 0.01 ± 0.001 μm, Rt 0.12 ± 0.09 μm, and Rsk = 5.67 ± 8.7; for the in vitro specimens they were Ra 0.05 ± 0.12 μm, Rt 0.71 ± 1.4 μm and Rsk 7.73 ± 20.6. The wettability angle measurements showed hydrophilic surfaces for all femoral heads considered in this study with small differences between the three investigated categories, allowing to discuss their effects on the biobearings’ lubrication phenomena.