Fumio Sasazawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fumio Sasazawa has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Norimasa Iwasaki
Department of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine Hokkaido University Sapporo Japan
4 shared publications - Davide Fontanarosa
School of Clinical Sciences, Faculty of Health, Queensland University of Technology, Brisbane, QLD 4000, Australia
3 shared publications - Ajay Kumar Pandey
Queensland University of Technology
2 shared publications - Maria Antico
School of Clinical Sciences, Faculty of Health, Queensland University of Technology, Brisbane, QLD 4000, Australia
2 shared publications - Tadashi Yamashita
School of Veterinary Medicine Azabu University Sagamihara Japan
2 shared publications - Tomohiro Onodera
Department of Orthopaedic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15 jo, Nishi 7 chome, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
2 shared publications
Latest Publications
- Open Access
- 28 May 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (11) , 5488
Automatic 3D MRI-Ultrasound Registration for Image Guided Arthroscopy
Registration of partial view intra-operative ultrasound (US) to pre-operative MRI is an essential step in image-guided minimally invasive surgery. In this paper, we present an automatic, landmark-free 3D multimodal registration of pre-operative MRI to 4D US (high-refresh-rate 3D-US) for enabling guidance in knee arthroscopy. We focus on the problem of initializing registration in the case of partial views. The proposed method utilizes a pre-initialization step of using the automatically segmented structures from both modalities to achieve a global geometric initialization. This is followed by computing distance maps of the procured segmentations for registration in the distance space. Following that, the final local refinement between the MRI-US volumes is achieved using the LC (Linear correlation of linear combination) metric. The method is evaluated on 11 cases spanning six subjects, with four levels of knee flexion. A best-case error of 1.41 mm and 2.34 and an average registration error of 3.45 mm and 7.76 is achieved in translation and rotation, respectively. An inter-observer variability study is performed, and a mean difference of 4.41 mm and 7.77 is reported. The errors obtained through the developed registration algorithm and inter-observer difference values are found to be comparable. We have shown that the proposed algorithm is simple, robust and allows for the automatic global registration of 3D US and MRI that can enable US based image guidance in minimally invasive procedures.- 28 May 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (11) , 5488
Open AccessAutomatic 3D MRI-Ultrasound Registration for Image Guided Arthroscopy
Registration of partial view intra-operative ultrasound (US) to pre-operative MRI is an essential step in image-guided minimally invasive surgery. In this paper, we present an automatic, landmark-free 3D multimodal registration of pre-operative MRI to 4D US (high-refresh-rate 3D-US) for enabling guidance in knee arthroscopy. We focus on the problem of initializing registration in the case of partial views. The proposed method utilizes a pre-initialization step of using the automatically segmented structures from both modalities to achieve a global geometric initialization. This is followed by computing distance maps of the procured segmentations for registration in the distance space. Following that, the final local refinement between the MRI-US volumes is achieved using the LC (Linear correlation of linear combination) metric. The method is evaluated on 11 cases spanning six subjects, with four levels of knee flexion. A best-case error of 1.41 mm and 2.34 and an average registration error of 3.45 mm and 7.76 is achieved in translation and rotation, respectively. An inter-observer variability study is performed, and a mean difference of 4.41 mm and 7.77 is reported. The errors obtained through the developed registration algorithm and inter-observer difference values are found to be comparable. We have shown that the proposed algorithm is simple, robust and allows for the automatic global registration of 3D US and MRI that can enable US based image guidance in minimally invasive procedures. - 1 February 2020
- Published by Elsevier in Medical Image Analysis
- Vol. 60, 101631
Siam-U-Net: encoder-decoder siamese network for knee cartilage tracking in ultrasound images
- 1 February 2020
- Published by Elsevier in Medical Image Analysis
- Vol. 60, 101631
Siam-U-Net: encoder-decoder siamese network for knee cartilage tracking in ultrasound images
- 27 March 2019
- Published by Morressier GmbH
1757 - Towards Robotic Knee Arthroscopy: Creating A 3D Ultrasound Based Knee Atlas To Introduce 4D Ultrasonography As Robotic Vision Modality For Guidance
INTRODUCTION: Recent advancements in technology have made robotic assisted orthopaedic surgery possible. In particular, we are investigating the |
- 27 March 2019
- Published by Morressier GmbH
1757 - Towards Robotic Knee Arthroscopy: Creating A 3D Ultrasound Based Knee Atlas To Introduce 4D Ultrasonography As Robotic Vision Modality For Guidance
INTRODUCTION: Recent advancements in technology have made robotic assisted orthopaedic surgery possible. In particular, we are investigating the |
- 1 February 2019
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 27 (2) , 314-325
Coordinated existence of multiple gangliosides is required for cartilage metabolism
- 1 February 2019
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 27 (2) , 314-325
Coordinated existence of multiple gangliosides is required for cartilage metabolism
- Open Access
- 3 April 2017
- Published by sPage.direcT in Journal of Orthopedic Surgery and Techniques
- Vol. 1 (1)
Efficacy of Adjunctive Antibiotic-Loaded Acrylic Bone Cement for Deep Surgical Site Infection Prophylaxis after Primary Cemented Hip and Knee Arthroplasties
The efficacy of antibiotic-loaded acrylic bone cements (ALBC) for prophylaxis of deep surgical site infections (deep SSIs) after primary cemented joint replacement surgery remains controversial. Therefore, the purpose of this study was to examine the issue, with respect to three types of arthroplasty, namely, total knee arthroplasty (TKA), total hip arthroplasty (THA), and bipolar hip arthroplasty (BHA).
- 3 April 2017
- Published by sPage.direcT in Journal of Orthopedic Surgery and Techniques
- Vol. 1 (1)
Open AccessEfficacy of Adjunctive Antibiotic-Loaded Acrylic Bone Cement for Deep Surgical Site Infection Prophylaxis after Primary Cemented Hip and Knee Arthroplasties
The efficacy of antibiotic-loaded acrylic bone cements (ALBC) for prophylaxis of deep surgical site infections (deep SSIs) after primary cemented joint replacement surgery remains controversial. Therefore, the purpose of this study was to examine the issue, with respect to three types of arthroplasty, namely, total knee arthroplasty (TKA), total hip arthroplasty (THA), and bipolar hip arthroplasty (BHA).
- 1 February 2014
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 22 (2) , 313-322
Depletion of gangliosides enhances cartilage degradation in mice
- 1 February 2014
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 22 (2) , 313-322
Depletion of gangliosides enhances cartilage degradation in mice
- 1 January 2014
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 22 (1) , 121-127
Chondroprotective effects of high-molecular-weight cross-linked hyaluronic acid in a rabbit knee osteoarthritis model
- 1 January 2014
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 22 (1) , 121-127
Chondroprotective effects of high-molecular-weight cross-linked hyaluronic acid in a rabbit knee osteoarthritis model