Rebecca Gregory
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rebecca Gregory has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Glenn D. Flux
The Institute of Cancer Research, 123 Old Brompton Road, London, SW7 3RP, United Kingdom; Joint Department of Physics, Royal Marsden NHSFT, Downs Road, Sutton, SM2 5PT, United Kingdom
7 shared publications Andrew Fenwick
National Physical Laboratory, Teddington, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
2 shared publications- Andrew Hall
Clinical Trials Research Unit Leeds Institute of Clinical Trials Research, University of Leeds Leeds UK
2 shared publications Iain Murray
Physics, Royal Marsden NHS Foundation Trust, Sutton, SM2 5PT, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
2 shared publicationsJonathan Gear
Physics, Royal Marsden NHS Foundation Trust, Sutton, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
2 shared publications- Jonathan Wadsley
Weston Park Hospital, Sheffield, S10 2SJ, UK
2 shared publications
Latest Publications
- Open Access
- 2 March 2021
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 94 (1119) , 20200072
SOLLID – a single centre study to develop methods to investigate the effects of low radiation doses within nuclear medicine, to enable multicentre epidemiological investigations
There is continuing debate concerning the risks of secondary malignancies from low levels of radiation exposure. The current model used for radiation protection is predicated on the assumption that even very low levels of exposure may entail risk. This has profound implications for medical procedures involving ionising radiation as radiation doses must be carefully monitored, and for diagnostic procedures are minimised as far as possible. This incurs considerable expense. The SOLLID study (ClinicalTrials.gov Identifier: NCT03580161) aims to develop the methodology to enable a large-scale epidemiological investigation of the effect of radiopharmaceutical administrations to patients undergoing diagnostic nuclear medicine procedures. Patients will undergo a series of scans in addition to that acquired as standard of care to enable the radiation doses delivered to healthy organs to be accurately calculated. Detailed analysis will be performed to determine the uncertainty in the radiation dose calculations as a function of the number and type of scans acquired. It is intended that this will inform a subsequent long-term multicentre epidemiological study that would address the question definitively. Secondary aims of the study are to evaluate the range of absorbed doses that are delivered from diagnostic nuclear medicine procedures and to use current risk models to ascertain the relative risks from these administrations.
- 2 March 2021
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 94 (1119) , 20200072
Open AccessSOLLID – a single centre study to develop methods to investigate the effects of low radiation doses within nuclear medicine, to enable multicentre epidemiological investigations
There is continuing debate concerning the risks of secondary malignancies from low levels of radiation exposure. The current model used for radiation protection is predicated on the assumption that even very low levels of exposure may entail risk. This has profound implications for medical procedures involving ionising radiation as radiation doses must be carefully monitored, and for diagnostic procedures are minimised as far as possible. This incurs considerable expense. The SOLLID study (ClinicalTrials.gov Identifier: NCT03580161) aims to develop the methodology to enable a large-scale epidemiological investigation of the effect of radiopharmaceutical administrations to patients undergoing diagnostic nuclear medicine procedures. Patients will undergo a series of scans in addition to that acquired as standard of care to enable the radiation doses delivered to healthy organs to be accurately calculated. Detailed analysis will be performed to determine the uncertainty in the radiation dose calculations as a function of the number and type of scans acquired. It is intended that this will inform a subsequent long-term multicentre epidemiological study that would address the question definitively. Secondary aims of the study are to evaluate the range of absorbed doses that are delivered from diagnostic nuclear medicine procedures and to use current risk models to ascertain the relative risks from these administrations.
- 11 December 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (24) , 245038
IPEM topical report: current molecular radiotherapy service provision and guidance on the implications of setting up a dosimetry service
Despite a growth in molecular radiotherapy treatment (MRT) and an increase in interest, centres still rarely perform MRT dosimetry. The aims of this report were to assess the main reasons why centres are not performing MRT dosimetry and provide advice on the resources required to set-up such a service. A survey based in the United Kingdom was developed to establish how many centres provide an MRT dosimetry service and the main reasons why it is not commonly performed. Twenty-eight per cent of the centres who responded to the survey performed some form of dosimetry, with 88% of those centres performing internal dosimetry. The survey showed that a ‘lack of clinical evidence’, a ‘lack of guidelines’ and ‘not current UK practice’ were the largest obstacles to setting up an MRT dosimetry service. More practical considerations, such as ‘lack of software’ and ‘lack of staff training/expertise’, were considered to be of lower significance by the respondents. Following on from the survey, this report gives an overview of the current guidelines, and the evidence available demonstrating the benefits of performing MRT dosimetry. The resources required to perform such techniques are detailed with reference to guidelines, training resources and currently available software. It is hoped that the information presented in this report will allow MRT dosimetry to be performed more frequently and in more centres, both in routine clinical practice and in multicentre trials. Such trials are required to harmonise dosimetry techniques between centres, build on the current evidence base, and provide the data necessary to establish the dose–response relationship for MRT.
- 11 December 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (24) , 245038
IPEM topical report: current molecular radiotherapy service provision and guidance on the implications of setting up a dosimetry service
Despite a growth in molecular radiotherapy treatment (MRT) and an increase in interest, centres still rarely perform MRT dosimetry. The aims of this report were to assess the main reasons why centres are not performing MRT dosimetry and provide advice on the resources required to set-up such a service. A survey based in the United Kingdom was developed to establish how many centres provide an MRT dosimetry service and the main reasons why it is not commonly performed. Twenty-eight per cent of the centres who responded to the survey performed some form of dosimetry, with 88% of those centres performing internal dosimetry. The survey showed that a ‘lack of clinical evidence’, a ‘lack of guidelines’ and ‘not current UK practice’ were the largest obstacles to setting up an MRT dosimetry service. More practical considerations, such as ‘lack of software’ and ‘lack of staff training/expertise’, were considered to be of lower significance by the respondents. Following on from the survey, this report gives an overview of the current guidelines, and the evidence available demonstrating the benefits of performing MRT dosimetry. The resources required to perform such techniques are detailed with reference to guidelines, training resources and currently available software. It is hoped that the information presented in this report will allow MRT dosimetry to be performed more frequently and in more centres, both in routine clinical practice and in multicentre trials. Such trials are required to harmonise dosimetry techniques between centres, build on the current evidence base, and provide the data necessary to establish the dose–response relationship for MRT.
- Open Access
- 1 December 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (24) , 245013
Standardised quantitative radioiodine SPECT/CT Imaging for multicentre dosimetry trials in molecular radiotherapy
The SEL-I-METRY trial (EudraCT No 2015-002269-47) is the first multicentre trial to investigate the role of 123I and 131I SPECT/CT-based tumour dosimetry to predict response to radioiodine therapy. Standardised dosimetry methodology is essential to provide a robust evidence-base for absorbed dose–response thresholds for molecular radiotherapy (MRT). In this paper a practical standardised protocol is used to establish the first network of centres with consistent methods of radioiodine activity quantification. Nine SPECT/CT systems at eight centres were set-up for quantitative radioiodine imaging. The dead-time of the systems was characterised for up to 2.8 GBq 131I. Volume dependent calibration factors were measured on centrally reconstructed images of 123I and 131I in six (0.8–196 ml) cylinders. Validation of image quantification using these calibration factors was performed on three systems, by imaging a 3D-printed phantom mimicking a patient’s activity distribution. The percentage differences between the activities measured in the SPECT/CT image and those measured by the radionuclide calibrator were calculated. Additionally uncertainties on the SPECT/CT-based activities were calculated to indicate the limit on the quantitative accuracy of this method. For systems set-up to image high 131I count rates, the count rate versus activity did not peak below 2.8 GBq and fit a non-paralysable model. The dead-times and volume-dependent calibration factors were comparable between systems of the same model and crystal thickness. Therefore a global calibration curve could be fitted to each. The errors on the validation phantom activities’ were comparable to the measurement uncertainties derived from uncertainty analysis, at 10% and 16% on average for 123I and 131I respectively in a 5 cm sphere. In conclusion, the dead-time and calibration factors varied between centres, with different models of system. However, global calibration factors may be applied to the same system model with the same crystal thickness, to simplify set-up of future multi-centre MRT studies.
- 1 December 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (24) , 245013
Open AccessStandardised quantitative radioiodine SPECT/CT Imaging for multicentre dosimetry trials in molecular radiotherapy
The SEL-I-METRY trial (EudraCT No 2015-002269-47) is the first multicentre trial to investigate the role of 123I and 131I SPECT/CT-based tumour dosimetry to predict response to radioiodine therapy. Standardised dosimetry methodology is essential to provide a robust evidence-base for absorbed dose–response thresholds for molecular radiotherapy (MRT). In this paper a practical standardised protocol is used to establish the first network of centres with consistent methods of radioiodine activity quantification. Nine SPECT/CT systems at eight centres were set-up for quantitative radioiodine imaging. The dead-time of the systems was characterised for up to 2.8 GBq 131I. Volume dependent calibration factors were measured on centrally reconstructed images of 123I and 131I in six (0.8–196 ml) cylinders. Validation of image quantification using these calibration factors was performed on three systems, by imaging a 3D-printed phantom mimicking a patient’s activity distribution. The percentage differences between the activities measured in the SPECT/CT image and those measured by the radionuclide calibrator were calculated. Additionally uncertainties on the SPECT/CT-based activities were calculated to indicate the limit on the quantitative accuracy of this method. For systems set-up to image high 131I count rates, the count rate versus activity did not peak below 2.8 GBq and fit a non-paralysable model. The dead-times and volume-dependent calibration factors were comparable between systems of the same model and crystal thickness. Therefore a global calibration curve could be fitted to each. The errors on the validation phantom activities’ were comparable to the measurement uncertainties derived from uncertainty analysis, at 10% and 16% on average for 123I and 131I respectively in a 5 cm sphere. In conclusion, the dead-time and calibration factors varied between centres, with different models of system. However, global calibration factors may be applied to the same system model with the same crystal thickness, to simplify set-up of future multi-centre MRT studies.
- Open Access
- 14 June 2019
- Published by Springer Nature in BMC Cancer
- Vol. 19 (1) , 1-10
Investigating the potential clinical benefit of Selumetinib in resensitising advanced iodine refractory differentiated thyroid cancer to radioiodine therapy (SEL-I-METRY): protocol for a multicentre UK single arm phase II trial
Thyroid cancer is the most common endocrine malignancy. Some advanced disease is, or becomes, resistant to radioactive iodine therapy (refractory disease); this holds poor prognosis of 10% 10-year overall survival. Whilst Sorafenib and Lenvatinib are now licenced for the treatment of progressive iodine refractory thyroid cancer, these treatments require continuing treatment and can be associated with significant toxicity. Evidence from a pilot study has demonstrated feasibility of Selumetinib to allow the reintroduction of I-131 therapy; this larger, multicentre study is required to demonstrate the broader clinical impact of this approach before progression to a confirmatory trial. SEL-I-METRY is a UK, single-arm, multi-centre, two-stage phase II trial. Participants with locally advanced or metastatic differentiated thyroid cancer with at least one measureable lesion and iodine refractory disease will be recruited from eight NHS Hospitals and treated with four-weeks of oral Selumetinib and assessed for sufficient I-123 uptake (defined as any uptake in a lesion with no previous uptake or 30% or greater increase in uptake). Those with sufficient uptake will be treated with I-131 and followed for clinical outcomes. Radiation absorbed doses will be predicted from I-123 SPECT/CT and verified from scans following the therapy. Sixty patients will be recruited to assess the primary objective of whether the treatment schedule leads to increased progression-free survival compared to historical control data. The SEL-I-METRY trial will investigate the effect of Selumetinib followed by I-131 therapy on progression-free survival in radioiodine refractory patients with differentiated thyroid cancer showing increased radioiodine uptake following initial treatment with Selumetinib. In addition, information on toxicity and dosimetry will be collected. This study presents an unprecedented opportunity to investigate the role of lesional dosimetry in molecular radiotherapy, leading to greater personalisation of therapy. To date this has been a neglected area of research. The findings of this trial will be useful to healthcare professionals and patients alike to determine whether further study of this agent is warranted. It is hoped that the development of the infrastructure to deliver a multicentre trial involving molecular radiotherapy dosimetry will lead to further trials in this field. SEL-I-METRY is registered under ISRCTN17468602 , 02/12/2015.
- 14 June 2019
- Published by Springer Nature in BMC Cancer
- Vol. 19 (1) , 1-10
Open AccessInvestigating the potential clinical benefit of Selumetinib in resensitising advanced iodine refractory differentiated thyroid cancer to radioiodine therapy (SEL-I-METRY): protocol for a multicentre UK single arm phase II trial
Thyroid cancer is the most common endocrine malignancy. Some advanced disease is, or becomes, resistant to radioactive iodine therapy (refractory disease); this holds poor prognosis of 10% 10-year overall survival. Whilst Sorafenib and Lenvatinib are now licenced for the treatment of progressive iodine refractory thyroid cancer, these treatments require continuing treatment and can be associated with significant toxicity. Evidence from a pilot study has demonstrated feasibility of Selumetinib to allow the reintroduction of I-131 therapy; this larger, multicentre study is required to demonstrate the broader clinical impact of this approach before progression to a confirmatory trial. SEL-I-METRY is a UK, single-arm, multi-centre, two-stage phase II trial. Participants with locally advanced or metastatic differentiated thyroid cancer with at least one measureable lesion and iodine refractory disease will be recruited from eight NHS Hospitals and treated with four-weeks of oral Selumetinib and assessed for sufficient I-123 uptake (defined as any uptake in a lesion with no previous uptake or 30% or greater increase in uptake). Those with sufficient uptake will be treated with I-131 and followed for clinical outcomes. Radiation absorbed doses will be predicted from I-123 SPECT/CT and verified from scans following the therapy. Sixty patients will be recruited to assess the primary objective of whether the treatment schedule leads to increased progression-free survival compared to historical control data. The SEL-I-METRY trial will investigate the effect of Selumetinib followed by I-131 therapy on progression-free survival in radioiodine refractory patients with differentiated thyroid cancer showing increased radioiodine uptake following initial treatment with Selumetinib. In addition, information on toxicity and dosimetry will be collected. This study presents an unprecedented opportunity to investigate the role of lesional dosimetry in molecular radiotherapy, leading to greater personalisation of therapy. To date this has been a neglected area of research. The findings of this trial will be useful to healthcare professionals and patients alike to determine whether further study of this agent is warranted. It is hoped that the development of the infrastructure to deliver a multicentre trial involving molecular radiotherapy dosimetry will lead to further trials in this field. SEL-I-METRY is registered under ISRCTN17468602 , 02/12/2015.
- 20 May 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1100) , 20190117
Clinical trials in molecular radiotherapy—Tribulations and Triumphs Report of the NCRI CTRad meeting held at the Lift Islington, 8 June 2018
It has been almost a decade since the commentary Molecular radiotherapy — the radionuclide raffle? by Gaze and Flux (2010). The overarching feeling then was that no individual or organisation has taken up the challenge, nationally or internationally, of championing molecular targeted radionuclide therapy in all its aspects. Here, we report on the recent NCRI–CTRad (Clinical Trials in Molecular Radiotherapy–Tribulations and Triumphs) meeting, held in London on the 8 June 2018. The meeting was organized by the NCRI–CTRad to review the challenges and opportunities for clinical trials in molecular radiotherapy, particularly focussing on investigator-led trials that incorporate imaging and dosimetry, and to discuss how the community can move forward. This meeting was organised in conjunction with the British Nuclear Medicine Society and reflects the progress of Nuclear Medicine in the UK.
- 20 May 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1100) , 20190117
Clinical trials in molecular radiotherapy—Tribulations and Triumphs Report of the NCRI CTRad meeting held at the Lift Islington, 8 June 2018
It has been almost a decade since the commentary Molecular radiotherapy — the radionuclide raffle? by Gaze and Flux (2010). The overarching feeling then was that no individual or organisation has taken up the challenge, nationally or internationally, of championing molecular targeted radionuclide therapy in all its aspects. Here, we report on the recent NCRI–CTRad (Clinical Trials in Molecular Radiotherapy–Tribulations and Triumphs) meeting, held in London on the 8 June 2018. The meeting was organized by the NCRI–CTRad to review the challenges and opportunities for clinical trials in molecular radiotherapy, particularly focussing on investigator-led trials that incorporate imaging and dosimetry, and to discuss how the community can move forward. This meeting was organised in conjunction with the British Nuclear Medicine Society and reflects the progress of Nuclear Medicine in the UK.
- Open Access
- 1 May 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1073) , 20160637
SELIMETRY—a multicentre I-131 dosimetry trial: a clinical perspective
Treatment options for patients with thyroid cancer that is no longer sensitive to iodine therapy are limited. Those treatments which currently exist are associated with significant toxicity. The SE...
- 1 May 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1073) , 20160637
Open AccessSELIMETRY—a multicentre I-131 dosimetry trial: a clinical perspective
Treatment options for patients with thyroid cancer that is no longer sensitive to iodine therapy are limited. Those treatments which currently exist are associated with significant toxicity. The SE...
- Open Access
- 14 December 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (1) , 17-30
Objective comparison of lesion detectability in low and medium-energy collimator iodine-123 mIBG images using a channelized Hotelling observer
Iodine-123 mIBG imaging is widely regarded as a gold standard for diagnostic studies of neuroblastoma and adult neuroendocrine cancer although the optimal collimator for tumour imaging remains undetermined. Low-energy (LE) high-resolution (HR) collimators provide superior spatial resolution. However due to septal penetration of high-energy photons these provide poorer contrast than medium-energy (ME) general-purpose (GP) collimators. LEGP collimators improve count sensitivity. The aim of this study was to objectively compare the lesion detection efficiency of each collimator to determine the optimal collimator for diagnostic imaging.
- 14 December 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (1) , 17-30
Open AccessObjective comparison of lesion detectability in low and medium-energy collimator iodine-123 mIBG images using a channelized Hotelling observer
Iodine-123 mIBG imaging is widely regarded as a gold standard for diagnostic studies of neuroblastoma and adult neuroendocrine cancer although the optimal collimator for tumour imaging remains undetermined. Low-energy (LE) high-resolution (HR) collimators provide superior spatial resolution. However due to septal penetration of high-energy photons these provide poorer contrast than medium-energy (ME) general-purpose (GP) collimators. LEGP collimators improve count sensitivity. The aim of this study was to objectively compare the lesion detection efficiency of each collimator to determine the optimal collimator for diagnostic imaging.
- 14 March 2009
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 36 (7) , 1037-1048
Optimization and assessment of quantitative 124I imaging on a Philips Gemini dual GS PET/CT system
Quantitative 124I PET imaging is challenging as 124I has a complex decay scheme. In this study the performance of a Philips Gemini dual GS PET/CT system was optimized and assessed for 124I. The energy window giving the maximum noise equivalent count rate (NECR) and NEMA 2001-NU2 image quality were measured. The activity concentration (AC) accuracy of images calibrated using factors from 18F and 124I decaying source measurements were investigated. The energy window 455–588 keV gave the maximum NECR of 9.67 kcps for 233 MBq. 124I and 18F image quality was comparable, although 124I background variability was increased. The average underestimation in AC in 124I images was 17.9 ± 2.9% for nonuniform background and 14.7 ± 2.9% for single scatter simulation (SSS) subtraction scatter correction. At 224 MBq the underestimation was 10.8 ± 11.3%, which is comparable to 7.7 ± 5.3% for 18F, but increased with decreasing activity. The best 124I PET quantitative accuracy was achieved for the optimized energy window, using SSS scatter correction and calibration factors from decaying 124I source measurements. The quantitative accuracy for 124I was comparable to that for 18F at high activities of 224 MBq but diminishing with decreasing activity. Specific corrections for prompt γ-photons may further improve the quantitative accuracy.
- 14 March 2009
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 36 (7) , 1037-1048
Optimization and assessment of quantitative 124I imaging on a Philips Gemini dual GS PET/CT system
Quantitative 124I PET imaging is challenging as 124I has a complex decay scheme. In this study the performance of a Philips Gemini dual GS PET/CT system was optimized and assessed for 124I. The energy window giving the maximum noise equivalent count rate (NECR) and NEMA 2001-NU2 image quality were measured. The activity concentration (AC) accuracy of images calibrated using factors from 18F and 124I decaying source measurements were investigated. The energy window 455–588 keV gave the maximum NECR of 9.67 kcps for 233 MBq. 124I and 18F image quality was comparable, although 124I background variability was increased. The average underestimation in AC in 124I images was 17.9 ± 2.9% for nonuniform background and 14.7 ± 2.9% for single scatter simulation (SSS) subtraction scatter correction. At 224 MBq the underestimation was 10.8 ± 11.3%, which is comparable to 7.7 ± 5.3% for 18F, but increased with decreasing activity. The best 124I PET quantitative accuracy was achieved for the optimized energy window, using SSS scatter correction and calibration factors from decaying 124I source measurements. The quantitative accuracy for 124I was comparable to that for 18F at high activities of 224 MBq but diminishing with decreasing activity. Specific corrections for prompt γ-photons may further improve the quantitative accuracy.