EAEhab Marouf Attalla

Ehab Marouf Attalla

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ehab Marouf Attalla has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Radiobiological Effects for Prostate Cancer High-Dose-Rate Brachytherapy

    by Alaa A. Abou Khadra, Intesar A. El-Mesady, Ehab M. Attalla, Mohamed A. Shehata

    Background: HDR brachytherapy represents a cornerstone in prostate cancer management by enabling high tumor doses while sparing surrounding normal tissues. Radiobiological modelling allows quantitative assessment of tumour control and normal tissue complication probability for optimization of fractionation schedules. Objective: The purpose of this study is to comparatively appraise the radiobiological outcome of two HDR brachytherapy regimens, 13.5 Gy × 2 fractions versus 15 Gy × 1 fraction, regarding tumor control probability, normal tissue complication probability, and dose-effect metrics in patients presenting with intermediate- to high-risk prostate cancer. Materials and Methods: A retrospective analysis of 20 patients treated by Co-60 HDR brachytherapy was performed. The treatment planning was image-based, in which, target and organ-at-risk delineation was followed standard guidelines. BED, EQD2, and Deff were computed using the linear-quadratic model. TCP and NTCP modeling utilized Poisson-based and Lyman–Kutcher–Burman methods, respectively. Correlations between radiobiological parameters and TCP/NTCP were analyzed. Results: The single 15 Gy fraction regimen resulted in significantly higher BED, EQD2, Deff, and modeled TCP compared with 13.5 Gy×2 fractions (p ≤ 0.031). However, NTCP for urethra at 10% volume was higher in the 15 Gy group (8.42% ± 1.58 vs. 6.86% ± 1.24; p = 0.006). Strong positive correlations were observed between BED, EQD2, Deff and TCP (ρ = 0.984–1.000; p < 0.001). NTCP at 30% urethral volume negatively correlated with BED, EQD2, and Deff (ρ ≈ -0.52; p = 0.003). Conclusions: Higher radiobiological doses (BED, EQD2, Deff) in prostate HDR brachytherapy are strongly associated with improved tumor control, with Deff showing perfect correlation with TCP. A single 15 Gy fraction yields greater radiobiological effectiveness than 13.5 Gy × 2. Urethral toxicity shows no clear correlation at 10% volume but a strong negative correlation at 30%, indicating that higher doses may reduce toxicity at this level. Radiobiological modeling is thus valuable for optimizing HDR planning, enhancing tumor control prediction, and balancing urethral toxicity.

  • Open Access

    Assessment of radiation doses in computed tomography scans using simulation models versus experimental verification and cancer risk estimation in pediatric phantom

    by Ehab M. Attalla, Raghda A. El Gendy, Shireen A. Abdelbadee, Abdelrahman S. Mosallam, Rasha A. Elawady

    Objective: This study aims to develop a methodology for estimating the absorbed dose in various organs of a pediatric phantom during computed tomography (CT) scans. The approach combines Monte Carlo simulations with experimental validation to ensure the accuracy of the numerical results. Methods: This study employed thermoluminescent dosimeters (TLDs) and GEANT4/GATE-based Monte Carlo simulations to estimate and validate organ dose measurements in a pediatric phantom. The phantom was irradiated utilizing a Siemens CT scanner at appropriate parameters (120 kVp and 60 mA). We calculated the dose at identical positions within the phantom using Monte Carlo simulations and subsequently compared the dose results. Results: The absorbed doses recorded by the TLDs for the left eye, right eye, thyroid, left lung, right lung, left pelvic, right pelvic, and testes were 18.93 ± 1.02, 16.47 ± 0.86, 28.37 ± 1.63, 16.30 ± 1.06, 15.21 ± 1.26, 14.33 ± 0.01, 14.10 ± 1.6, and 17.91 ± 0.16 mGy, respectively. The calculated absorbed doses in the respective organs using GEANT4/GATE were: 16.96 ± 1.99, 16.75 ± 1.45, 29.61 ± 0.77, 16.92 ± 0.08, 16.26 ± 0.39, 15.07 ± 0.01, 14.91 ± 0.75, and 17.94 ± 0.041 mGy. The results indicate a strong concordance between the two methods, with percentage differences of 11.6%, 1.7%, 4.4%, 3.77%, 6.9%, 5.14%, 5.74%, and 0.17%, respectively. Conclusion: The strong agreement between simulation results and experimental measurements enhances the ability to estimate absorbed doses in radiosensitive organs during CT scans. Additionally, the study utilizes phantom dose data to evaluate the risk of secondary cancers in susceptible organs, highlighting a relationship between lifetime risk and excess absolute risk for both males and females.

  • Open Access

    Optimizing Head and Neck Cancer Radiotherapy: A Dosimetric Comparison of FF and FFF Beams in VMAT

    by Reham S. Sherif, Limam Ahmed Neya, Ahmed M. Abdelaal, Ehab M. Attalla, Reem H. El-Gebaly

    Aim: Head and neck cancer (HNC) is a significant global health concern, with rising incidence rates and a high prevalence in South Asia, particularly in India. Radiation therapy, including advanced techniques like Volumetric-Modulated Arc Therapy (VMAT) and Intensity-Modulated Radiotherapy (IMRT), plays a crucial role in treating HNC. This study aims to compare the dosimetric and biological and second cancer risk estimation differences between flattened (FF) and flattening filter-free (FFF) beams in VMAT treatment plans for HNC, focusing on the impact of 6 MV and 10 MV energies.Methods: Twenty HNC patients underwent replanning using VMAT on an ELEKTA VERSA HD linear accelerator with 6 MV FF, 6 MV FFF, 10 MV FF, and 10 MV FFF beams. Dosimetric parameters evaluated included dose distribution to planning target volumes (PTVs) and dose delivered to 98% of the target (D98), 50% (D50), and 2% (D2), as well as doses to organs at risk (OARs)., monitor units per segment (MU/Segment), number of MU/cGy, treatment delivery time, conformity index, and homogeneity index, also biological parameters (NTCP and EUD) and second cancer risk estimation were evaluated.Results: The results showed that 6 MV FFF beams provided slightly better dose-sparing for OARs compared to 6 MV FF, with no significant differences in target volume coverage. Both FF and FFF beams demonstrated comparable conformity indices, but FF beams had better homogeneity indices. FFF beams required more monitor units (MUs) and segments but offered reduced treatment delivery times. For 10 MV beams, FFF showed marginal advantages in dose homogeneity and sparing of normal tissues at lower doses, though it required more MUs and segments, this study found that NTCP and EUD were largely comparable between FF and FFF types, with minor but statistically significant differences for the brainstem (favoring FFF) and heart. Second cancer risks varied slightly by energy and technique 6MV FFF reduced parotid risks (though increased larynx risk).Conclusion: 6 MV beams, particularly FFF, showed slight advantages in sparing OARs and target volume coverage compared to 10 MV beams. This study highlights the dosimetric comparability of FF and FFF beams in HNC treatment, with FFF offering potential benefits in treatment efficiency and reduced delivery times. This study also shows that FF and FFF types yield comparable radiobiological outcomes, though 6MV FFF beams slightly reduce doses to critical organs without sacrificing efficacy. Both types perform similarly, with minor risk variations by energy.

  • Open Access

    Radiobiological Study for HDR Cervical Brachytherapy: Dosimetric Correlations and Clinical Validation

    by Asmaa M. El Doushy, Ehab M. Atalla, I.H Ibrahim, S.M. El Sayed, Ayat M. Saadeldin

    Purpose: High-dose-rate (HDR) brachytherapy remains a cornerstone in the definitive management of locally advanced cervical cancer. While conventional metrics derived from dose-volume histograms (DVHs) guide treatment planning, radiobiological modeling—using tumor control probability (TCP) and normal tissue complication probability (NTCP)—offers enhanced predictive capacity for clinical outcomes. This study evaluates the clinical applicability of TCP and NTCP models to optimize HDR brachytherapy. Materials and Methods: A retrospective dosimetric analysis was conducted on 30 cervical cancer patients (FIGO stage IIB–IIIB), treated with HDR intracavitary brachytherapy using Fletcher-Suit-Delclos applicators between 2022 and 2024. TCP was calculated applying a Poisson-based linear-quadratic model, whereas NTCP estimations for rectum, bladder, and sigmoid colon were based on the Lyman-Kutcher-Burman model. Correlations between radiobiological indices and conventional dosimetric parameters were assessed via Pearson correlations. Results: TCP values demonstrated exceptional tumor control probabilities, ranging from 99.37% to 99.85% (median: 99.80%). NTCP values exhibited notable variabilities: rectum (0.0003%–0.3885%, median 0.0178%), bladder (0.0032%–0.6938%, median 0.0731%), and sigmoid colon (0.0000%–0.0405%, median 0.0001%). Significant positive correlations were observed between TCP and HR-CTV D90 (r=0.62, pConclusions: Radiobiological modeling integrating TCP and NTCP substantially complements dosimetric parameters, enabling improved prediction of therapeutic outcomes and toxicity risks in HDR brachytherapy for cervical cancer. The strong correlations observed endorse the integration of these tools into routine clinical workflows to facilitate personalized treatment optimization.

  • Open Access

    Determination of Setup Margin for Nasopharyngeal Carcinoma by Using Electroinc Portal Imaging Device

    by Safa Elfaramawy, Ehab Attalla, Fathi Elhussiny, Mohamed Alm El-Din, Ahmed Elmekawy

    Introduction: This study aimed to assess three-dimensional (3D) setup mistakes and provide optimal margins for planned target volume (PTV) coverage in head and neck radiation. Methods: Ten patients participated in the trial, receiving IMRT in conjunction with weekly electronic portal imaging (EPI). A total of 170 portal pictures were analyzed. The systematic (S) and random (s) errors in the population of patients with head and neck cancer were assessed using portal images in the caudocranial longitudinal (CC) and left-right lateral (LR) orientations, measured within the anterior-posterior (AP) field. The clinical-to-planning target volume (CTV-PTV) margins were determined in accordance with ICRU Report 62 guidelines and van Herk’s formulae. Results: The group systematic errors and random errors were 0.19 and 0.26 cm , respectively in the anteroposterior direction; the group systematic errors and random errors were 0.15 cm and 0.24 cm in SI direction, respectively; the group systematic errors and random errors were 0.13 cm and 0.25 cm in LR direction, respectively; According to the classical van-Herk formula MPTV =2.5Σ +0.7σ, we figured out the ideal PTV margins (MPTV) based on the setup errors and 0.65 cm, 0.55 cm, and 0.5 cm were required in the AP, SI, and RL directions. Discussion and conclusions: we can conclude that a 6-mm extension of CTV to PTV margin, as the optimal margin and can be reduced with increasing frequency of online verification (daily imaging) or for patients where the prescribed does not exceed tolerance doses for organs at risk.

  • Open Access

    Physical and Radiobiological Evaluation of Patient Setup Errors in the Radiotherapy Procedure for Prostate Cancer

    by Asmaa Moustafa, Ehab Marouf Attalla, S.M. El-Sayed, Ibrahim Hassan

    Radiobiological and dosimetric indices related effects of patient setup errors were evaluated for prostate patients treated using volumetric modulated arc therapy technique. Materials and Methods: Ten patients were treated and evaluated during the course of treatment. Each one was treated with 2 Gy for 39 fractions. The setup verification of each patient was determined using an electronic portal imaging device for 5 fractions during the treatment course. The mean of setup errors for those 5 fractions was calculated for each patient. Dose-Volume Histograms of the planning target volume, femoral heads, bladder and rectum were generated, and the conformity index, homogeneity index, tumor control probability, and normal tissue complication probability were determined.The population random set-up errors were (3.61), (3.24), and (3.87) mm in vertical, longitudinal, and lateral directions respectively. Radiobiological indexes were evaluated witht and without inrtoduction of the random errors. In the original plan the average EUD in the VMAT plans was 77.59 Gy, and the average of TCP was 98.24%; but with the introduction of the errors, the average EUD became in the order of 60.24 Gy, while the average of TCP was in the order of 84.24%. Significant differences were observed between the two plans. The dosimetric and biological impacts were evaluated and indicated that setup errors during VMAT treatments can lead to a non-significant change of conformity and homogeneity but can lead to changes in the dose distribution influencing the target volume coverage and altering the deliver dose to the organs at risk.

  • Physical and Radiobiological Evaluation of Gamma Knife Radiosurgery Plans in the Treatment of Meningioma: Comparison between two isodose lines (50% and 75%)

    by ‪Gad Yahia Elbaz‬, Hedaya Mohammed Hendam, ElSayed Mohammed Alashkar, Khairy Mohammed Tohamy, Ehab Marouf Attalla

    This work explores how the choice of prescription isodose line (IDL) achieves a high probability of local tumor control (Tumor Control Probability, TCP) at low risk of normal tissue complications (Normal Tissue Complications Probability, NTCP) for Gamma Knife Radiosurgery at two different plans applying different isodose lines to evaluate the radiosurgical metrics, plan quality, and outcome probability in treatment of meningioma using Gamma Knife Radiosurgery (GKS). METHODS: The cross-sectional study included 10 patients (4 male and 6 female) with median age of 42 years (21-66) and presented with radiologically diagnosed meningioma. Two radiosurgical forward plans were applied with same marginal dose of 12Gy at two different isodose lines of 50% and 75% isodose alternatively using Leksell Gamma Plan of single session GKS. A quantitative approach has been conducted to evaluate and compare both plans. Dose-volume histogram was imported to MATLAB to compute tumor control probability (TCP), normal tissue complications probability (NTCP) values at 5 years for each plan, and physical indices such as coverage, selectivity, conformity, heterogeneity, and gradient indices. RESULTS: Median target irradiated volume was 5.44 cm3(0.59-23.72). TCP was significantly higher in the plan using 50% isodose line for the marginal dose than that using 75% isodose line (94.98%, 45.09%, p=0.0018, Mann-Whitney test). Brainstem and optic apparatus NTCPs were very low with median of 0.01% (0-0.03%) in the former plan and zero in the later one (p=0.005, Mann-Whitney test). CONCLUSION: Radiobiological models and physical indices could be used for the optimum plan selection of GKS.

  • Open Access

    Developing and implementing a multi-modality imaging optimization study in paediatric radiology: Experience and recommendations from an IAEA coordinated research project

    by H. Delis, P. Homolka, C.L. Chapple, P.R. Costa, E. Attalla, L.E. Lubis, T.A. Sackey, F. Fahey, M. Lassmann, G.L. Poli