Guilherme Bicalho Saturnino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Guilherme Bicalho Saturnino has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Axel Thielscher
Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
18 shared publications - Kristoffer Hougaard Madsen
Technical University of Denmark
10 shared publications - Oula Puonti
Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital – Amager and Hvidovre, Copenhagen, Denmark
4 shared publications Hartwig R. Siebner
Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Denmark; Department of Neurology, Copenhagen University Hospital Bispebjerg, Copenhagen, Denmark; Institute for Clinical Medicine, Faculty of Medical and Health Sciences, University of Copenhagen, Copenhagen, Denmark
3 shared publications- Daria Antonenko
Department of Neurology, University Medicine Greifswald, Germany
2 shared publications - Hartwig Roman Siebner
Danish Research Centre for Magnetic Resonance, Department of Radiology and Nuclear Medicine, Copenhagen University Hospital - Amager and Hvidovre
2 shared publications
Latest Publications
- 11 February 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (1) , 014001
Optimizing the electric field strength in multiple targets for multichannel transcranial electric stimulation
Objective. Most approaches to optimize the electric field pattern generated by multichannel transcranial electric stimulation (TES) require the definition of a preferred direction of the electric field in the target region(s). However, this requires knowledge about how the neural effects depend on the field direction, which is not always available. Thus, it can be preferential to optimize the field strength in the target(s), irrespective of the field direction. However, this results in a more complex optimization problem. Approach. We introduce and validate a novel optimization algorithm that maximizes focality while controlling the electric field strength in the target to maintain a defined value. It obeys the safety constraints, allows limiting the number of active electrodes and allows also for multi-target optimization. Main results. The optimization algorithm outperformed naïve search approaches in both quality of the solution and computational efficiency. Using the amygdala as test case, we show that it allows for reaching a reasonable trade-off between focality and field strength in the target. In contrast, simply maximizing the field strength in the target results in far more extended fields. In addition, by maintaining the pre-defined field strengths in the targets, the new algorithm allows for a balanced stimulation of two or more regions. Significance. The novel algorithm can be used to automatically obtain individualized, optimal montages for targeting regions without the need to define preferential directions. It will automatically select the field direction that achieves the desired field strength in the target(s) with the most focal stimulation pattern.
- 11 February 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (1) , 014001
Optimizing the electric field strength in multiple targets for multichannel transcranial electric stimulation
Objective. Most approaches to optimize the electric field pattern generated by multichannel transcranial electric stimulation (TES) require the definition of a preferred direction of the electric field in the target region(s). However, this requires knowledge about how the neural effects depend on the field direction, which is not always available. Thus, it can be preferential to optimize the field strength in the target(s), irrespective of the field direction. However, this results in a more complex optimization problem. Approach. We introduce and validate a novel optimization algorithm that maximizes focality while controlling the electric field strength in the target to maintain a defined value. It obeys the safety constraints, allows limiting the number of active electrodes and allows also for multi-target optimization. Main results. The optimization algorithm outperformed naïve search approaches in both quality of the solution and computational efficiency. Using the amygdala as test case, we show that it allows for reaching a reasonable trade-off between focality and field strength in the target. In contrast, simply maximizing the field strength in the target results in far more extended fields. In addition, by maintaining the pre-defined field strengths in the targets, the new algorithm allows for a balanced stimulation of two or more regions. Significance. The novel algorithm can be used to automatically obtain individualized, optimal montages for targeting regions without the need to define preferential directions. It will automatically select the field direction that achieves the desired field strength in the target(s) with the most focal stimulation pattern.
- Open Access
- 1 January 2021
- Published by Elsevier in NeuroImage
- Vol. 224, 117413
Inter-individual and age-dependent variability in simulated electric fields induced by conventional transcranial electrical stimulation
- 1 January 2021
- Published by Elsevier in NeuroImage
- Vol. 224, 117413
Open AccessInter-individual and age-dependent variability in simulated electric fields induced by conventional transcranial electrical stimulation
- Top Cited PapersOpen Access
- 1 October 2020
- Published by Elsevier in NeuroImage
- Vol. 219, 117044
Accurate and robust whole-head segmentation from magnetic resonance images for individualized head modeling
- 1 October 2020
- Published by Elsevier in NeuroImage
- Vol. 219, 117044
Top Cited PapersOpen AccessAccurate and robust whole-head segmentation from magnetic resonance images for individualized head modeling
- Open Access
Optimizing the Electric Field Strength in Multiple Targets for Multichannel Transcranial Electric Stimulation
Objective: Most approaches to optimize the electric field pattern generated by multichannel Transcranial Electric Stimulation (TES) require the definition of a preferred direction of the electric field in the target region(s). However, this requires knowledge about how the neural effects depend on the field direction, which is not always available. Thus, it can be preferential to optimize the field strength in the target(s), irrespective of the field direction. However, this results in a more complex optimization problem. Approach: We introduce and validate a novel optimization algorithm that maximizes focality while controlling the electric field strength in the target to maintain a defined value. It obeys the safety constraints, allows limiting the number of active electrodes and allows also for multi-target optimization. Main Results: The optimization algorithm outperformed naïve search approaches in both quality of the solution and computational efficiency. Using the amygdala as test case, we show that it allows for reaching a reasonable trade-off between focality and field strength in the target. In contrast, simply maximizing the field strength in the target results in far more extended fields. In addition, by maintaining the pre-defined field strengths in the targets, the new algorithm allows for a balanced stimulation of two or more regions. Significance: The novel algorithm can be used to automatically obtain individualized, optimal montages for targeting regions without the need to define preferential directions. It will automatically select the field direction that achieves the desired field strength in the target(s) with the most focal stimulation pattern.
Open AccessOptimizing the Electric Field Strength in Multiple Targets for Multichannel Transcranial Electric Stimulation
Objective: Most approaches to optimize the electric field pattern generated by multichannel Transcranial Electric Stimulation (TES) require the definition of a preferred direction of the electric field in the target region(s). However, this requires knowledge about how the neural effects depend on the field direction, which is not always available. Thus, it can be preferential to optimize the field strength in the target(s), irrespective of the field direction. However, this results in a more complex optimization problem. Approach: We introduce and validate a novel optimization algorithm that maximizes focality while controlling the electric field strength in the target to maintain a defined value. It obeys the safety constraints, allows limiting the number of active electrodes and allows also for multi-target optimization. Main Results: The optimization algorithm outperformed naïve search approaches in both quality of the solution and computational efficiency. Using the amygdala as test case, we show that it allows for reaching a reasonable trade-off between focality and field strength in the target. In contrast, simply maximizing the field strength in the target results in far more extended fields. In addition, by maintaining the pre-defined field strengths in the targets, the new algorithm allows for a balanced stimulation of two or more regions. Significance: The novel algorithm can be used to automatically obtain individualized, optimal montages for targeting regions without the need to define preferential directions. It will automatically select the field direction that achieves the desired field strength in the target(s) with the most focal stimulation pattern.
- Top Cited Papers
- 6 November 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (6) , 066032
Electric field simulations for transcranial brain stimulation using FEM: an efficient implementation and error analysis
Objective . Transcranial magnetic stimulation (TMS) and transcranial electric stimulation (TES) modulate brain activity non-invasively by generating electric fields either by electromagnetic induction or by injecting currents via skin electrodes. Numerical simulations based on anatomically detailed head models of the TMS and TES electric fields can help us to understand and optimize the spatial stimulation pattern in the brain. However, most realistic simulations are still slow, and the role of anatomical fidelity on simulation accuracy has not been evaluated in detail so far. Approach . We present and validate a new implementation of the finite element method (FEM) for TMS and TES that is based on modern algorithms and libraries. We also evaluate the convergence of the simulations and estimate errors stemming from numerical and modelling aspects. Main results . Comparisons with analytical solutions for spherical phantoms validate our new FEM implementation, which is three to six times faster than previous implementations. The convergence results suggest that accurately capturing the tissue geometry in addition to choosing a sufficiently accurate numerical method is of fundamental importance for accurate simulations. Significance . The new implementation allows for a substantial increase in computational efficiency of FEM TMS and TES simulations. This is especially relevant for applications such as the systematic assessment of model uncertainty and the optimization of multi-electrode TES montages. The results of our systematic error analysis allow the user to select the best tradeoff between model resolution and simulation speed for a specific application. The new FEM code is openly available as a part of our open-source software SimNIBS 3.0.
- 6 November 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (6) , 066032
Top Cited PapersElectric field simulations for transcranial brain stimulation using FEM: an efficient implementation and error analysis
Objective . Transcranial magnetic stimulation (TMS) and transcranial electric stimulation (TES) modulate brain activity non-invasively by generating electric fields either by electromagnetic induction or by injecting currents via skin electrodes. Numerical simulations based on anatomically detailed head models of the TMS and TES electric fields can help us to understand and optimize the spatial stimulation pattern in the brain. However, most realistic simulations are still slow, and the role of anatomical fidelity on simulation accuracy has not been evaluated in detail so far. Approach . We present and validate a new implementation of the finite element method (FEM) for TMS and TES that is based on modern algorithms and libraries. We also evaluate the convergence of the simulations and estimate errors stemming from numerical and modelling aspects. Main results . Comparisons with analytical solutions for spherical phantoms validate our new FEM implementation, which is three to six times faster than previous implementations. The convergence results suggest that accurately capturing the tissue geometry in addition to choosing a sufficiently accurate numerical method is of fundamental importance for accurate simulations. Significance . The new implementation allows for a substantial increase in computational efficiency of FEM TMS and TES simulations. This is especially relevant for applications such as the systematic assessment of model uncertainty and the optimization of multi-electrode TES montages. The results of our systematic error analysis allow the user to select the best tradeoff between model resolution and simulation speed for a specific application. The new FEM code is openly available as a part of our open-source software SimNIBS 3.0.
- Open Access
Comparing and Validating Automated Tools for Individualized Electric Field Simulations in the Human Head
Comparing electric field simulations from individualized head models against in-vivo recordings is important for direct validation of computational field modeling for transcranial brain stimulation and brain mapping techniques such as electro- and magnetoencephalography. This also helps to improve simulation accuracy by pinning down the factors having the largest influence on the simulations. Here we compare field simulations from four different automated pipelines, against intracranial voltage recordings in an existing dataset of 14 epilepsy patients. We show that ignoring uncertainty in the simulations leads to a strong bias in the estimated linear relationship between simulated and measured fields. In addition, even though the simulations between the pipelines differ notably, this is not reflected in the correlation with the measurements. We discuss potential reasons for this apparent mismatch and propose a new Bayesian regression analysis of the data that yields unbiased estimates enabling robust conclusions to be reached.
Open AccessComparing and Validating Automated Tools for Individualized Electric Field Simulations in the Human Head
Comparing electric field simulations from individualized head models against in-vivo recordings is important for direct validation of computational field modeling for transcranial brain stimulation and brain mapping techniques such as electro- and magnetoencephalography. This also helps to improve simulation accuracy by pinning down the factors having the largest influence on the simulations. Here we compare field simulations from four different automated pipelines, against intracranial voltage recordings in an existing dataset of 14 epilepsy patients. We show that ignoring uncertainty in the simulations leads to a strong bias in the estimated linear relationship between simulated and measured fields. In addition, even though the simulations between the pipelines differ notably, this is not reflected in the correlation with the measurements. We discuss potential reasons for this apparent mismatch and propose a new Bayesian regression analysis of the data that yields unbiased estimates enabling robust conclusions to be reached.
- Open Access
- 1 March 2019
- Published by Elsevier in NeuroImage
- Vol. 188, 821-834
A principled approach to conductivity uncertainty analysis in electric field calculations
- 1 March 2019
- Published by Elsevier in NeuroImage
- Vol. 188, 821-834
Open AccessA principled approach to conductivity uncertainty analysis in electric field calculations
- Open Access
- 6 February 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (2) , 024001
Comparative performance of the finite element method and the boundary element fast multipole method for problems mimicking transcranial magnetic stimulation (TMS)
Objective . A study pertinent to the numerical modeling of cortical neurostimulation is conducted in an effort to compare the performance of the finite element method (FEM) and an original formulation of the boundary element fast multipole method (BEM-FMM) at matched computational performance metrics. Approach . We consider two problems: (i) a canonic multi-sphere geometry and an external magnetic-dipole excitation where the analytical solution is available and; (ii) a problem with realistic head models excited by a realistic coil geometry. In the first case, the FEM algorithm tested is a fast open-source getDP solver running within the SimNIBS 2.1.1 environment. In the second case, a high-end commercial FEM software package ANSYS Maxwell 3D is used. The BEM-FMM method runs in the MATLAB ® 2018a environment. Main results . In the first case, we observe that the BEM-FMM algorithm gives a smaller solution error for all mesh resolutions and runs significantly faster for high-resolution meshes when the number of triangular facets exceeds approximately 0.25 M. We present other relevant simulation results such as volumetric mesh generation times for the FEM, time necessary to compute the potential integrals for the BEM-FMM, and solution performance metrics for different hardware/operating system combinations. In the second case, we observe an excellent agreement for electric field distribution across different cranium compartments and, at the same time, a speed improvement of three orders of magnitude when the BEM-FMM algorithm used. Significance . This study may provide a justification for anticipated use of the BEM-FMM algorithm for high-resolution realistic transcranial magnetic stimulation scenarios.
- 6 February 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (2) , 024001
Open AccessComparative performance of the finite element method and the boundary element fast multipole method for problems mimicking transcranial magnetic stimulation (TMS)
Objective . A study pertinent to the numerical modeling of cortical neurostimulation is conducted in an effort to compare the performance of the finite element method (FEM) and an original formulation of the boundary element fast multipole method (BEM-FMM) at matched computational performance metrics. Approach . We consider two problems: (i) a canonic multi-sphere geometry and an external magnetic-dipole excitation where the analytical solution is available and; (ii) a problem with realistic head models excited by a realistic coil geometry. In the first case, the FEM algorithm tested is a fast open-source getDP solver running within the SimNIBS 2.1.1 environment. In the second case, a high-end commercial FEM software package ANSYS Maxwell 3D is used. The BEM-FMM method runs in the MATLAB ® 2018a environment. Main results . In the first case, we observe that the BEM-FMM algorithm gives a smaller solution error for all mesh resolutions and runs significantly faster for high-resolution meshes when the number of triangular facets exceeds approximately 0.25 M. We present other relevant simulation results such as volumetric mesh generation times for the FEM, time necessary to compute the potential integrals for the BEM-FMM, and solution performance metrics for different hardware/operating system combinations. In the second case, we observe an excellent agreement for electric field distribution across different cranium compartments and, at the same time, a speed improvement of three orders of magnitude when the BEM-FMM algorithm used. Significance . This study may provide a justification for anticipated use of the BEM-FMM algorithm for high-resolution realistic transcranial magnetic stimulation scenarios.
- Open Access
Efficient Electric Field Simulations for Transcranial Brain Stimulation
Objective: Transcranial magnetic stimulation (TMS) and transcranial electric stimulation (TES) modulate brain activity non-invasively by generating electric fields either by electromagnetic induction or by injecting currents via skin electrodes. Numerical simulations based on anatomically detailed head models of the TMS and TES electric fields can help us to understand and optimize the spatial stimulation pattern in the brain. However, most realistic simulations are still slow, and their numerical accuracy and the factors that influence it have not been evaluated in detail so far. Approach: We present and validate a new implementation of the Finite Element Method (FEM) for TMS and TES that is based on modern algorithms and libraries. We also evaluate the convergence of the simulations and give estimates for the discretization errors. Main results: Comparisons with analytical solutions for spherical head models validate our new FEM implementation. It is five to ten times faster than previous implementations. The convergence results suggest that accurately capturing the tissue geometry in addition to choosing a sufficiently high mesh density is of fundamental importance for accurate simulations. Significance: The new implementation allows for a substantial increase in computational efficiency of TMS and TES simulations. This is especially relevant for applications such as the systematic assessment of model uncertainty and the optimization of multi-electrode TES montages. The results of our systematic error analysis allow the user to select the best tradeoff between model resolution and simulation speed for a specific application. The new FEM code will be made openly available as a part of our open-source software SimNIBS 3.0.
Open AccessEfficient Electric Field Simulations for Transcranial Brain Stimulation
Objective: Transcranial magnetic stimulation (TMS) and transcranial electric stimulation (TES) modulate brain activity non-invasively by generating electric fields either by electromagnetic induction or by injecting currents via skin electrodes. Numerical simulations based on anatomically detailed head models of the TMS and TES electric fields can help us to understand and optimize the spatial stimulation pattern in the brain. However, most realistic simulations are still slow, and their numerical accuracy and the factors that influence it have not been evaluated in detail so far. Approach: We present and validate a new implementation of the Finite Element Method (FEM) for TMS and TES that is based on modern algorithms and libraries. We also evaluate the convergence of the simulations and give estimates for the discretization errors. Main results: Comparisons with analytical solutions for spherical head models validate our new FEM implementation. It is five to ten times faster than previous implementations. The convergence results suggest that accurately capturing the tissue geometry in addition to choosing a sufficiently high mesh density is of fundamental importance for accurate simulations. Significance: The new implementation allows for a substantial increase in computational efficiency of TMS and TES simulations. This is especially relevant for applications such as the systematic assessment of model uncertainty and the optimization of multi-electrode TES montages. The results of our systematic error analysis allow the user to select the best tradeoff between model resolution and simulation speed for a specific application. The new FEM code will be made openly available as a part of our open-source software SimNIBS 3.0.
- Top Cited PapersOpen Access
- 1 January 2019
- Published by Elsevier in NeuroImage
- Vol. 185, 300-312
The non-transcranial TMS-evoked potential is an inherent source of ambiguity in TMS-EEG studies
- 1 January 2019
- Published by Elsevier in NeuroImage
- Vol. 185, 300-312
Top Cited PapersOpen AccessThe non-transcranial TMS-evoked potential is an inherent source of ambiguity in TMS-EEG studies