Ignacio Vieto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ignacio Vieto has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Jian Sun
Department of Electrical, Computer and Systems Engineering, Rensselaer Polytechnic Institute, 8024 Troy, New York, United States, 12180-3522
2 shared publications
Latest Publications
- Open Access
- 25 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 1, 513-528
Development and Application of Type-III Turbine Impedance Models Including DC Bus Dynamics
Several small-signal impedance models have been reported for type-III wind turbines. Common to these models is the assumption that the dc bus between the rotor- and stator-side converters is an ideal voltage source. Under this assumption, there is no dynamic coupling between the two converters and the turbine can be represented by the impedance of the stator-side converter in parallel with the impedance of the induction generator with the rotor-side converter behind it. The assumption is well justified above the second harmonic frequency but introduces considerable error at lower frequencies, especially within 20-30 Hz of the fundamental where dc bus voltage control is active and dc bus capacitor impedance is high. This paper presents the development and application of full-order sequence impedance models for type-III turbines that include dc bus dynamics. The new models consider the coupled current responses created by each of the converters as well as their coupling across the dc bus. Inclusion of these additional dynamics leads to more accurate prediction of turbine impedance responses and turbine-grid system stability. A comparison with existing models is presented to show the utility and limitation of each model. A practical resonance problem is also presented to demonstrate the application.
- 25 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 1, 513-528
Open AccessDevelopment and Application of Type-III Turbine Impedance Models Including DC Bus Dynamics
Several small-signal impedance models have been reported for type-III wind turbines. Common to these models is the assumption that the dc bus between the rotor- and stator-side converters is an ideal voltage source. Under this assumption, there is no dynamic coupling between the two converters and the turbine can be represented by the impedance of the stator-side converter in parallel with the impedance of the induction generator with the rotor-side converter behind it. The assumption is well justified above the second harmonic frequency but introduces considerable error at lower frequencies, especially within 20-30 Hz of the fundamental where dc bus voltage control is active and dc bus capacitor impedance is high. This paper presents the development and application of full-order sequence impedance models for type-III turbines that include dc bus dynamics. The new models consider the coupled current responses created by each of the converters as well as their coupling across the dc bus. Inclusion of these additional dynamics leads to more accurate prediction of turbine impedance responses and turbine-grid system stability. A comparison with existing models is presented to show the utility and limitation of each model. A practical resonance problem is also presented to demonstrate the application.
- 16 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (2) , 537-545
Sequence Impedance Modeling and Analysis of Type-III Wind Turbines
Sequence impedance models are presented for type-III wind turbines that use doubly-fed induction generators (DFIG) and back-to-back voltage source converters. The models, presented in analytical form for both positive and negative sequence impedances, include the effects of the induction machine, both the stator and rotor side converters as well as their controls, and the phase-locked loop (PLL) used for synchronizing converter control with the grid voltage. The models are valid from subsynchronous frequency up to 1/3 of the switching frequency of the converter, making them useful for the analysis and mitigation of both subsynchronous and supersynchronous resonances and control interactions of type-III turbines with different types of grid.
- 16 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (2) , 537-545
Sequence Impedance Modeling and Analysis of Type-III Wind Turbines
Sequence impedance models are presented for type-III wind turbines that use doubly-fed induction generators (DFIG) and back-to-back voltage source converters. The models, presented in analytical form for both positive and negative sequence impedances, include the effects of the induction machine, both the stator and rotor side converters as well as their controls, and the phase-locked loop (PLL) used for synchronizing converter control with the grid voltage. The models are valid from subsynchronous frequency up to 1/3 of the switching frequency of the converter, making them useful for the analysis and mitigation of both subsynchronous and supersynchronous resonances and control interactions of type-III turbines with different types of grid.