Pascal Maussion
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pascal Maussion has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Antoine Picot
Universit de Toulouse, CNRS, INPT, UPS,Laplace,Toulouse,France
4 shared publications - Georges Zissis
Université de Toulouse, Toulouse INP, CNRS, LAPLACE, UMR 5213, 31000 Toulouse, France
4 shared publications - Laurent Canale
Université de Toulouse, Toulouse INP, CNRS, LAPLACE, UMR 5213, 31000 Toulouse, France
3 shared publications - Andrea Al Haddad
LAPLACE, Universit de Toulouse, Toulouse, France
2 shared publications Antoine Picot
LAPLACE, Universit de Toulouse, CNRS, INPT, UPS, Toulouse, France
2 shared publications- Pascal Dupuis
LAPLACE, UMR 5213 (CNRS, INPT, UPS), Toulouse, France
2 shared publications
Latest Publications
- Open Access
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 661, 63-69
Contribution to a review of lithium-ion batteries diagnostic methods for space applications
Thanks to their excellent performance, lithium-ion batteries have become increasingly used in terrestrial and space applications. Despite the long lifespan, this type of battery is subject to inevitable aging dependent on electrochemical degradation phenomena. Defining a diagnostic method capable of estimating the state of health of a battery and predicting its end of life is therefore a priority to ensure proper functioning. Although considerable progress has been made in recent years in this research topic, most of the effort of the scientific community is concentrated in terrestrial applications. Of all the various existing approaches, both experimental and numerical, few are applicable within the limitations imposed by space applications. Hence, the main contribution of this paper is to provide an overview of the current state of the diagnostic methods adopted to estimate the aging of lithium-ion batteries used in satellites.
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 661, 63-69
Open AccessContribution to a review of lithium-ion batteries diagnostic methods for space applications
Thanks to their excellent performance, lithium-ion batteries have become increasingly used in terrestrial and space applications. Despite the long lifespan, this type of battery is subject to inevitable aging dependent on electrochemical degradation phenomena. Defining a diagnostic method capable of estimating the state of health of a battery and predicting its end of life is therefore a priority to ensure proper functioning. Although considerable progress has been made in recent years in this research topic, most of the effort of the scientific community is concentrated in terrestrial applications. Of all the various existing approaches, both experimental and numerical, few are applicable within the limitations imposed by space applications. Hence, the main contribution of this paper is to provide an overview of the current state of the diagnostic methods adopted to estimate the aging of lithium-ion batteries used in satellites.
- 16 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5329-5340
Improved Modelling of PDIV Evolution Over Time Under Multiple Ageing Factors for Insulation of Inverter-Fed Electrical Machines
This article describes research to model PDIV evolution under multi-factor stressing of the insulation system of an electrical machine. An attempt is made to establish whether a change of PDIV could be used to predict remaining life. Twisted pairs are used as samples of electrical motor insulation. They undergo accelerated ageing by exposure to high temperatures and the constant influence of inverter-style square-wave voltage. The ageing process lasts between weeks and months during which PDIV is measured periodically. The dedicated method of PDIV measurement with inverter-style voltage is presented. The evolution of PDIV is successfully modelled using an Inverse Power Model – observation and modelling of PDIV evolution is a novelty in the field. The ageing tests are performed according to the Design of Experiment method. The evolution of the parameters of the model at different factor levels can be extrapolated from the model obtained.
- 16 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5329-5340
Improved Modelling of PDIV Evolution Over Time Under Multiple Ageing Factors for Insulation of Inverter-Fed Electrical Machines
This article describes research to model PDIV evolution under multi-factor stressing of the insulation system of an electrical machine. An attempt is made to establish whether a change of PDIV could be used to predict remaining life. Twisted pairs are used as samples of electrical motor insulation. They undergo accelerated ageing by exposure to high temperatures and the constant influence of inverter-style square-wave voltage. The ageing process lasts between weeks and months during which PDIV is measured periodically. The dedicated method of PDIV measurement with inverter-style voltage is presented. The evolution of PDIV is successfully modelled using an Inverse Power Model – observation and modelling of PDIV evolution is a novelty in the field. The ageing tests are performed according to the Design of Experiment method. The evolution of the parameters of the model at different factor levels can be extrapolated from the model obtained.
- 13 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 676-683
Modeling OLED Luminance Decay Under Thermal, Constant and Cyclic Electrical Stress
Organic Light Emitting diodes (OLED) are lighting devices which are sensitive to a number of intrinsic and extrinsic stresses due to their organic nature. This paper proposes a study of the degradation of warm white, large area OLED panels under accelerated thermal and electrical stress as a tool to estimate their lifespan. The laboratory-induced stress reflects the usual on/off use of lighting in different conditions by applying not only constant, but also cyclic electrical current. The luminance decay path was modeled using linear and stretched exponential decay models, showing that luminance degradation has a linear path in more than $77\%$ of cases. The relationship between the decay rate parameter of the selected model and the stress factors, as well as the quadratic term of current was then constructed using a multi-linear regression method. It was found that cycling reduces the degradation rate by allowing the intrinsic characteristics of OLEDs to recover. Finally, the Joule losses presented in the quadratic term of the current were proved to accelerate the degradation rate of OLEDs.
- 13 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 676-683
Modeling OLED Luminance Decay Under Thermal, Constant and Cyclic Electrical Stress
Organic Light Emitting diodes (OLED) are lighting devices which are sensitive to a number of intrinsic and extrinsic stresses due to their organic nature. This paper proposes a study of the degradation of warm white, large area OLED panels under accelerated thermal and electrical stress as a tool to estimate their lifespan. The laboratory-induced stress reflects the usual on/off use of lighting in different conditions by applying not only constant, but also cyclic electrical current. The luminance decay path was modeled using linear and stretched exponential decay models, showing that luminance degradation has a linear path in more than $77\%$ of cases. The relationship between the decay rate parameter of the selected model and the stress factors, as well as the quadratic term of current was then constructed using a multi-linear regression method. It was found that cycling reduces the degradation rate by allowing the intrinsic characteristics of OLEDs to recover. Finally, the Joule losses presented in the quadratic term of the current were proved to accelerate the degradation rate of OLEDs.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (1) , 996-1004
Prediction of OLED Luminance Using Impedance Measurements
Luminance is the main feature indicating organic light-emitting diode (OLED) degradation; however, this requires delicate photometric measurements that are difficult and costly to realize in situ . In this article, an original luminance decay prediction method not requiring optical measurements will be presented. Analysis of the impedance revealed a strong correlation between the luminance and the time constant of the equivalent circuit. As a result, the time constant is chosen as the main feature to track OLED degradation, the evolution of which is linearly modeled over time at different stress levels using the design of experiments methodology. Simultaneously, a linear relationship between luminance degradation and the evolution of time constants, in terms of the thermal stress applied, enables prediction of the luminance degradation over time. This method is an accurate novel solution for luminance tracking in particular for data taken inside the experimental plan limits.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (1) , 996-1004
Prediction of OLED Luminance Using Impedance Measurements
Luminance is the main feature indicating organic light-emitting diode (OLED) degradation; however, this requires delicate photometric measurements that are difficult and costly to realize in situ . In this article, an original luminance decay prediction method not requiring optical measurements will be presented. Analysis of the impedance revealed a strong correlation between the luminance and the time constant of the equivalent circuit. As a result, the time constant is chosen as the main feature to track OLED degradation, the evolution of which is linearly modeled over time at different stress levels using the design of experiments methodology. Simultaneously, a linear relationship between luminance degradation and the evolution of time constants, in terms of the thermal stress applied, enables prediction of the luminance degradation over time. This method is an accurate novel solution for luminance tracking in particular for data taken inside the experimental plan limits.
- Top Cited Papers
- 18 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industrial Electronics Magazine
- Vol. 14 (4) , 158-167
Condition Monitoring of Industrial Electric Machines: State of the Art and Future Challenges
The limitations of the thermal, vibration, or electrical monitoring of electric machines such as false indications, low sensitivity, and difficulty of fault interpretation have recently been exposed. This has led to a shift in the direction in research toward applying new techniques for improving the reliability of condition monitoring. With the changing environment, the purpose of this article is to provide an overview of the recent trends in the industrial demand and research activity in condition monitoring technology. The new developments in insulation testing, electrical testing, flux analysis, transient analysis, and fault prognostics are summarized. The challenges and recommendations for future work for the new technologies are also explored to help support target research and development efforts according to industrial needs.
- 18 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industrial Electronics Magazine
- Vol. 14 (4) , 158-167
Top Cited PapersCondition Monitoring of Industrial Electric Machines: State of the Art and Future Challenges
The limitations of the thermal, vibration, or electrical monitoring of electric machines such as false indications, low sensitivity, and difficulty of fault interpretation have recently been exposed. This has led to a shift in the direction in research toward applying new techniques for improving the reliability of condition monitoring. With the changing environment, the purpose of this article is to provide an overview of the recent trends in the industrial demand and research activity in condition monitoring technology. The new developments in insulation testing, electrical testing, flux analysis, transient analysis, and fault prognostics are summarized. The challenges and recommendations for future work for the new technologies are also explored to help support target research and development efforts according to industrial needs.
- Open Access
- 3 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (3) , 3100-3113
Design of Experiments Predictive Models as a Tool for Lifespan Prediction and Comparison for Enameled Wires Used in Low-Voltage Inverter-Fed Motors
Since the development of power electronic components, which allowed the manufacturing of reliable and efficient inverters, variable speed drives using inductive motors have become more and more popular. The PWM technique has proven to be a very effective method of rotational speed control. However, the fast changing voltage pulses, with very steep slopes (in the order of a few kV/μs), has brought new hazards for the electrical insulation system of such motors. Very high frequency harmonic components of PWM voltage will result in significant overvoltage due to an impedance mismatch between the cable and the motor. As an effect, the voltage seen by some parts of the insulation system may exceed the Partial Discharge Inception Voltage (PDIV) stating localized partial discharges activity. The aim of this paper is to investigate and analyze the aging process of the enameled wire exposed to different factors and to propose a method allowing to predict their lifespans in given conditions. This study introduces a prediction based on the Design of Experiments method and the statistical Weibull distribution. Thanks to the model obtained with short multi-stress aging tests, it is possible to predict the results of significantly longer ones. Moreover, the adapted methodology is proposed that allows to predict the scatter of the long tests basing on the short-time results dispersion. The same approach is used to compare different products between each other and rank them. All model predictions are compared with the experimental data in order to prove the model accuracy.
- 3 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (3) , 3100-3113
Open AccessDesign of Experiments Predictive Models as a Tool for Lifespan Prediction and Comparison for Enameled Wires Used in Low-Voltage Inverter-Fed Motors
Since the development of power electronic components, which allowed the manufacturing of reliable and efficient inverters, variable speed drives using inductive motors have become more and more popular. The PWM technique has proven to be a very effective method of rotational speed control. However, the fast changing voltage pulses, with very steep slopes (in the order of a few kV/μs), has brought new hazards for the electrical insulation system of such motors. Very high frequency harmonic components of PWM voltage will result in significant overvoltage due to an impedance mismatch between the cable and the motor. As an effect, the voltage seen by some parts of the insulation system may exceed the Partial Discharge Inception Voltage (PDIV) stating localized partial discharges activity. The aim of this paper is to investigate and analyze the aging process of the enameled wire exposed to different factors and to propose a method allowing to predict their lifespans in given conditions. This study introduces a prediction based on the Design of Experiments method and the statistical Weibull distribution. Thanks to the model obtained with short multi-stress aging tests, it is possible to predict the results of significantly longer ones. Moreover, the adapted methodology is proposed that allows to predict the scatter of the long tests basing on the short-time results dispersion. The same approach is used to compare different products between each other and rank them. All model predictions are compared with the experimental data in order to prove the model accuracy.
- Open Access
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 5807-5813
Novel Configuration of a Three-phase Induction Generator for Single-phase Load: Simulations and Experimentations
This paper presents the study of an original configuration of an off-grid single-phase generator using a three-phase Squirrel Cage Induction Machine (SCIM). In this proposed structure, two of the generator stator windings are excited by two independent sources and the remaining winding is connected to the load. This configuration requires two voltage inverters for excitation. This allows better control flexibility in the inverter-assisted topology. Simulation model of the generator has been created to study its dynamic and steady-state characteristics. These behaviors of the generator have been verified using comprehensive laboratory tests. The use of this generator configuration is proposed according to the concept of frugal innovation to propose cheap solutions for rural electrification in remote areas in developing countries.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 5807-5813
Open AccessNovel Configuration of a Three-phase Induction Generator for Single-phase Load: Simulations and Experimentations
This paper presents the study of an original configuration of an off-grid single-phase generator using a three-phase Squirrel Cage Induction Machine (SCIM). In this proposed structure, two of the generator stator windings are excited by two independent sources and the remaining winding is connected to the load. This configuration requires two voltage inverters for excitation. This allows better control flexibility in the inverter-assisted topology. Simulation model of the generator has been created to study its dynamic and steady-state characteristics. These behaviors of the generator have been verified using comprehensive laboratory tests. The use of this generator configuration is proposed according to the concept of frugal innovation to propose cheap solutions for rural electrification in remote areas in developing countries.
- 17 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (6) , 6548-6558
Modeling the Luminance Degradation of OLEDs Using Design of Experiments
Modeling the lifespan of OLED (Organic Light-Emitting Diode) is a complex task as it depends on different - potentially interacting factors. As the literature on this subject is still scant, new parametric models for calculating the lifespan of OLED are proposed in this work. The Design of Experiment (DoE) methodology is used for cost and accuracy reasons. Different lifespan models based on thermal and electrical experimental aging tests are proposed. As stress factors, current density, temperature and their interactions, which are rarely taken into account in aging studies are simultaneously involved. The analysis of the model parameters highlights the prevalence of temperature compared to current density on the luminance performance of OLEDs. Non-linear models appear as the most accurate.
- 17 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (6) , 6548-6558
Modeling the Luminance Degradation of OLEDs Using Design of Experiments
Modeling the lifespan of OLED (Organic Light-Emitting Diode) is a complex task as it depends on different - potentially interacting factors. As the literature on this subject is still scant, new parametric models for calculating the lifespan of OLED are proposed in this work. The Design of Experiment (DoE) methodology is used for cost and accuracy reasons. Different lifespan models based on thermal and electrical experimental aging tests are proposed. As stress factors, current density, temperature and their interactions, which are rarely taken into account in aging studies are simultaneously involved. The analysis of the model parameters highlights the prevalence of temperature compared to current density on the luminance performance of OLEDs. Non-linear models appear as the most accurate.
- 1 April 2019
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 158, 281-295
Power alternator simulation models for diagnostic purposes
- 1 April 2019
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 158, 281-295
Power alternator simulation models for diagnostic purposes