Yusuke Watanabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yusuke Watanabe has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Osamu Abe
Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
5 shared publications - Shohei Inui
Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
3 shared publications Hidemasa Takao
Department of Radiology, The University of Tokyo, Graduate School of Medicine, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan
2 shared publications- Koichiro Yasaka
The University of Tokyo, Tokyo, Japan
2 shared publications - Ryo Kurokawa
Department of Radiology, Graduate School of Medicine, The University of Tokyo
2 shared publications - Takuya Kawahara
Clinical Research Promotion Center, The University of Tokyo Hospital, Tokyo, Japan
2 shared publications
Latest Publications
- Open Access
- 18 May 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (8) , 3263-3267
N-Butyl-cyanoacrylate-assisted retrograde transvenous obliteration (NARTO) for gastric varices
- 18 May 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (8) , 3263-3267
Open AccessN-Butyl-cyanoacrylate-assisted retrograde transvenous obliteration (NARTO) for gastric varices
- 31 January 2024
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 75 (3) , 542-548
Deep-Learning Reconstruction of High-Resolution CT Improves Interobserver Agreement for the Evaluation of Pulmonary Fibrosis
Objective: This study aimed to investigate whether deep-learning reconstruction (DLR) improves interobserver agreement in the evaluation of honeycombing for patients with interstitial lung disease (ILD) who underwent high-resolution computed tomography (CT) compared with hybrid iterative reconstruction (HIR). Methods: In this retrospective study, 35 consecutive patients suspected of ILD who underwent CT including the chest region were included. High-resolution CT images of the unilateral lung with DLR and HIR were reconstructed for the right and left lungs. A radiologist placed regions of interest on the lung and measured standard deviation of CT attenuation (i.e., quantitative image noise). In the qualitative image analyses, 5 blinded readers assessed the presence of honeycombing and reticulation, qualitative image noise, artifacts, and overall image quality using a 5-point scale (except for artifacts which was evaluated using a 3-point scale). Results: The quantitative and qualitative image noise in DLR was remarkably reduced compared to that in HIR ( P < .001). Artifacts and overall DLR quality were significantly improved compared to those of HIR ( P < .001 for 4 out of 5 readers). Interobserver agreement in the evaluations of honeycombing and reticulation for DLR (0.557 [0.450-0.693] and 0.525 [0.470-0.541], respectively) were higher than those for HIR (0.321 [0.211-0.520] and 0.470 [0.354-0.533], respectively). A statistically significant difference was found for honeycombing ( P = .014). Conclusions: DLR improved interobserver agreement in the evaluation of honeycombing in patients with ILD on CT compared to HIR.
- 31 January 2024
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 75 (3) , 542-548
Deep-Learning Reconstruction of High-Resolution CT Improves Interobserver Agreement for the Evaluation of Pulmonary Fibrosis
Objective: This study aimed to investigate whether deep-learning reconstruction (DLR) improves interobserver agreement in the evaluation of honeycombing for patients with interstitial lung disease (ILD) who underwent high-resolution computed tomography (CT) compared with hybrid iterative reconstruction (HIR). Methods: In this retrospective study, 35 consecutive patients suspected of ILD who underwent CT including the chest region were included. High-resolution CT images of the unilateral lung with DLR and HIR were reconstructed for the right and left lungs. A radiologist placed regions of interest on the lung and measured standard deviation of CT attenuation (i.e., quantitative image noise). In the qualitative image analyses, 5 blinded readers assessed the presence of honeycombing and reticulation, qualitative image noise, artifacts, and overall image quality using a 5-point scale (except for artifacts which was evaluated using a 3-point scale). Results: The quantitative and qualitative image noise in DLR was remarkably reduced compared to that in HIR ( P < .001). Artifacts and overall DLR quality were significantly improved compared to those of HIR ( P < .001 for 4 out of 5 readers). Interobserver agreement in the evaluations of honeycombing and reticulation for DLR (0.557 [0.450-0.693] and 0.525 [0.470-0.541], respectively) were higher than those for HIR (0.321 [0.211-0.520] and 0.470 [0.354-0.533], respectively). A statistically significant difference was found for honeycombing ( P = .014). Conclusions: DLR improved interobserver agreement in the evaluation of honeycombing in patients with ILD on CT compared to HIR.
- 5 October 2023
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 75 (2) , 351-358
Detection of Vertebral Mass and Diagnosis of Spinal Cord Compression in Computed Tomography With Deep Learning Reconstruction: Comparison With Hybrid Iterative Reconstruction
Purpose: To compare the impact of deep learning reconstruction (DLR) and hybrid-iterative reconstruction (hybrid-IR) on vertebral mass depiction, detection, and diagnosis of spinal cord compression on computed tomography (CT). Methods: This retrospective study included 29 and 20 patients with and without vertebral masses. CT images were reconstructed using DLR and hybrid-IR. Three readers performed vertebral mass detection tests and evaluated the presence of spinal cord compression, the depiction of vertebral masses, and image noise. Quantitative image noise was measured by placing regions of interest on the aorta and spinal cord. Results: Deep learning reconstruction tended to improve the performance of readers with less diagnostic imaging experience in detecting vertebral masses (area under the receiver operating characteristic curve [AUC] = 0.892-0.966) compared with hybrid-IR (AUC = 0.839-0.917). Diagnostic performance in evaluating spinal cord compression in DLR (AUC = 0.887-0.995) also improved compared with that in hybrid-IR (AUC = 0.866-0.942) for some readers. The depiction of vertebral masses and subjective image noise in DLR were significantly improved compared with those in hybrid-IR ( P < .041). Quantitative image noise in DLR was also significantly reduced compared with that in hybrid-IR ( P < .001). Conclusion: Deep learning reconstruction improved the depiction of vertebral masses, which resulted in a tendency to improve the performance of CT compared to hybrid-IR in detecting vertebral masses and diagnosing spinal cord compression for some readers.
- 5 October 2023
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 75 (2) , 351-358
Detection of Vertebral Mass and Diagnosis of Spinal Cord Compression in Computed Tomography With Deep Learning Reconstruction: Comparison With Hybrid Iterative Reconstruction
Purpose: To compare the impact of deep learning reconstruction (DLR) and hybrid-iterative reconstruction (hybrid-IR) on vertebral mass depiction, detection, and diagnosis of spinal cord compression on computed tomography (CT). Methods: This retrospective study included 29 and 20 patients with and without vertebral masses. CT images were reconstructed using DLR and hybrid-IR. Three readers performed vertebral mass detection tests and evaluated the presence of spinal cord compression, the depiction of vertebral masses, and image noise. Quantitative image noise was measured by placing regions of interest on the aorta and spinal cord. Results: Deep learning reconstruction tended to improve the performance of readers with less diagnostic imaging experience in detecting vertebral masses (area under the receiver operating characteristic curve [AUC] = 0.892-0.966) compared with hybrid-IR (AUC = 0.839-0.917). Diagnostic performance in evaluating spinal cord compression in DLR (AUC = 0.887-0.995) also improved compared with that in hybrid-IR (AUC = 0.866-0.942) for some readers. The depiction of vertebral masses and subjective image noise in DLR were significantly improved compared with those in hybrid-IR ( P < .041). Quantitative image noise in DLR was also significantly reduced compared with that in hybrid-IR ( P < .001). Conclusion: Deep learning reconstruction improved the depiction of vertebral masses, which resulted in a tendency to improve the performance of CT compared to hybrid-IR in detecting vertebral masses and diagnosing spinal cord compression for some readers.
- 25 November 2022
- Published by SAGE Publications in Acta Radiologica
- Vol. 64 (5) , 1958-1965
Computer-aided detection improves brain metastasis identification on non-enhanced CT in less experienced radiologists
Background: Brain metastases (BMs) are the most common intracranial tumors causing neurological complications associated with significant morbidity and mortality. Purpose: To evaluate the effect of computer-aided detection (CAD) on the performance of observers in detecting BMs on non-enhanced computed tomography (NECT). Material and Methods: Three less experienced and three experienced radiologists interpreted 30 NECT scans with 89 BMs in 25 cases to detect BMs with and without the assistance of CAD. The observers’ sensitivity, number of false positives (FPs), positive predictive value (PPV), and reading time with and without CAD were compared using paired t-tests. The sensitivity of CAD and the observers were compared using a one-sample t-test Results: With CAD, less experienced radiologists’ sensitivity significantly increased from 27.7% ± 4.6% to 32.6% ± 4.8% ( P = 0.007), while the experienced radiologists’ sensitivity did not show a significant difference (from 33.3% ± 3.5% to 31.9% ± 3.7%; P = 0.54). There was no significant difference between conditions with CAD and without CAD for FPs (less experienced radiologists: 23.0 ± 10.4 and 25.0 ± 9.3; P = 0.32; experienced radiologists: 18.3 ± 7.4 and 17.3 ± 6.7; P = 0.76) and PPVs (less experienced radiologists: 57.9% ± 8.3% and 50.9% ± 7.0%; P = 0.14; experienced radiologists: 61.8% ± 12.7% and 64.0% ± 12.1%; P = 0.69). There were no significant differences in reading time with and without CAD (85.0 ± 45.6 s and 73.7 ± 36.7 s; P = 0.09). The sensitivity of CAD was 47.2% (with a PPV of 8.9%), which was significantly higher than that of any radiologist ( P < 0.001). Conclusion: CAD improved BM detection sensitivity on NECT without increasing FPs or reading time among less experienced radiologists, but this was not the case among experienced radiologists.
- 25 November 2022
- Published by SAGE Publications in Acta Radiologica
- Vol. 64 (5) , 1958-1965
Computer-aided detection improves brain metastasis identification on non-enhanced CT in less experienced radiologists
Background: Brain metastases (BMs) are the most common intracranial tumors causing neurological complications associated with significant morbidity and mortality. Purpose: To evaluate the effect of computer-aided detection (CAD) on the performance of observers in detecting BMs on non-enhanced computed tomography (NECT). Material and Methods: Three less experienced and three experienced radiologists interpreted 30 NECT scans with 89 BMs in 25 cases to detect BMs with and without the assistance of CAD. The observers’ sensitivity, number of false positives (FPs), positive predictive value (PPV), and reading time with and without CAD were compared using paired t-tests. The sensitivity of CAD and the observers were compared using a one-sample t-test Results: With CAD, less experienced radiologists’ sensitivity significantly increased from 27.7% ± 4.6% to 32.6% ± 4.8% ( P = 0.007), while the experienced radiologists’ sensitivity did not show a significant difference (from 33.3% ± 3.5% to 31.9% ± 3.7%; P = 0.54). There was no significant difference between conditions with CAD and without CAD for FPs (less experienced radiologists: 23.0 ± 10.4 and 25.0 ± 9.3; P = 0.32; experienced radiologists: 18.3 ± 7.4 and 17.3 ± 6.7; P = 0.76) and PPVs (less experienced radiologists: 57.9% ± 8.3% and 50.9% ± 7.0%; P = 0.14; experienced radiologists: 61.8% ± 12.7% and 64.0% ± 12.1%; P = 0.69). There were no significant differences in reading time with and without CAD (85.0 ± 45.6 s and 73.7 ± 36.7 s; P = 0.09). The sensitivity of CAD was 47.2% (with a PPV of 8.9%), which was significantly higher than that of any radiologist ( P < 0.001). Conclusion: CAD improved BM detection sensitivity on NECT without increasing FPs or reading time among less experienced radiologists, but this was not the case among experienced radiologists.
- Open Access
- 1 December 2020
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 2 (6) , e200492
Comparison of Chest CT Grading Systems in COVID-19 Pneumonia
Purpose To compare the performance and interobserver agreement of the COVID-19 Reporting and Data System (CO-RADS), the COVID-19 imaging reporting and data system (COVID-RADS), the RSNA expert cons...
- 1 December 2020
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 2 (6) , e200492
Open AccessComparison of Chest CT Grading Systems in COVID-19 Pneumonia
Purpose To compare the performance and interobserver agreement of the COVID-19 Reporting and Data System (CO-RADS), the COVID-19 imaging reporting and data system (COVID-RADS), the RSNA expert cons...
- 28 July 2015
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 10 (1) , 61-68
Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques in quantifying coronary calcium
- 28 July 2015
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 10 (1) , 61-68
Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques in quantifying coronary calcium
- 1 August 2009
- Published by Springer Nature in Clinical and Experimental Nephrology
- Vol. 13 (4) , 385-388
A case report suggesting the occurrence of epithelial–mesenchymal transition in obstructive nephropathy
Epithelial–mesenchymal transition (EMT) has been well investigated using cultured kidney epithelial cell lines and the mouse obstructive nephropathy model. The role of EMT in the genesis or progression of human renal fibrosis remains controversial. We report a case of obstructive nephropathy that occurred in a pregnant woman. Renal tissue obtained by percutaneous renal biopsy after the delivery showed marked interstitial fibrosis and obstructive tubuli. Immunofluorescence images clearly demonstrated S100A4-positive tubular epithelial cells in these specimens. With regard to human obstructive nephropathy, this is the first report which proves that tubular epithelial cells become positive for the fibroblast-specific marker. EMT is probably a common event not only in mouse but also in human.
- 1 August 2009
- Published by Springer Nature in Clinical and Experimental Nephrology
- Vol. 13 (4) , 385-388
A case report suggesting the occurrence of epithelial–mesenchymal transition in obstructive nephropathy
Epithelial–mesenchymal transition (EMT) has been well investigated using cultured kidney epithelial cell lines and the mouse obstructive nephropathy model. The role of EMT in the genesis or progression of human renal fibrosis remains controversial. We report a case of obstructive nephropathy that occurred in a pregnant woman. Renal tissue obtained by percutaneous renal biopsy after the delivery showed marked interstitial fibrosis and obstructive tubuli. Immunofluorescence images clearly demonstrated S100A4-positive tubular epithelial cells in these specimens. With regard to human obstructive nephropathy, this is the first report which proves that tubular epithelial cells become positive for the fibroblast-specific marker. EMT is probably a common event not only in mouse but also in human.