Diane E. Gregory
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Diane E. Gregory has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Sabrina I. Sinopoli
Department of Kinesiology and Physical Education, Wilfrid Laurier University , Waterloo, ON N2L 3C5, Canada
5 shared publications Noah Chow
Department of Kinesiology and Physical Education, Canada
4 shared publicationsSabrina I. Sinopoli
Department of Kinesiology and Physical Education, Wilfrid Laurier University, 75 University Ave West, Waterloo, Ontario, Canada
4 shared publicationsDerek P. Zwambag
Kinesiology and Physical Education, Wilfrid Laurier University, Waterloo, ON, Canada
3 shared publications- Derek P. Zwambag
Department of Kinesiology & Physical Education, Wilfrid Laurier University, Waterloo, ON, Canada
3 shared publications John G. McMorran
Department of Kinesiology and Physical Education, Wilfrid Laurier University, Waterloo, ON, Canada
3 shared publications
Latest Publications
- Open Access
- 13 March 2026
- Published by Elsevier in Clinical Biomechanics
- Vol. 136, 106823
Postpartum biomechanical adaptations of the anterior abdominal wall in a rat model: Implications for diastasis rectus abdominis
- 13 March 2026
- Published by Elsevier in Clinical Biomechanics
- Vol. 136, 106823
Open AccessPostpartum biomechanical adaptations of the anterior abdominal wall in a rat model: Implications for diastasis rectus abdominis
- Open Access
- 23 October 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 173, 107241
The biomechanical properties of porcine intervertebral disc tissue treated with different fixation solutions
- 23 October 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 173, 107241
Open AccessThe biomechanical properties of porcine intervertebral disc tissue treated with different fixation solutions
- 7 July 2025
- Published by Springer Nature in European Spine Journal
- p. 1-10
The influence of decorin, a potential pro-inflammatory stimulant, on the mechanical properties of the annulus fibrosus
Purpose Structural disruption of the intervertebral disc can result in fragmentation of extracellular matrix components such as decorin, which has the capacity to mount an inflammatory response. However, it is unknown if decorin also alters the biomechanical properties of the intervertebral disc, and specifically the annulus fibrosus. Therefore, the purpose of this study was to investigate the potential of decorin to stimulate a pro-inflammatory environment and alter the mechanical integrity and tensile properties of a rat tail annulus. Methods Sixty annulus fibrosus rings were dissected from 15 rat tails and randomized into three culture conditions: (i) control; (ii) 0.5 µg/mL bovine decorin (low dose); (iii) 5 µg/mL bovine decorin (high dose). Samples were cultured for 6 days then tested via a tensile mechanical testing system. IL-6 and MIP-2 concentration in the culture media were quantified via enzyme-linked immunosorbent assays at day 6. Results IL-6 and MIP-2 were present in the media after six days of culture but did not differ between conditions. Decorin did, however, impact a number of tensile properties of the annulus. Specifically, the high dose of decorin resulted in greater toe region strain (p < 0.001) and greater failure strain (p < 0.001) as well as greater initial failure stress (p = 0.024) and maximum stress (p = 0.001). Discussion The observed increase in annulus strength may be a result of reorganization of the load-bearing collagen fibres while the increased strain may be due to degradation of other matrix proteins. Future work is necessary to further elucidate the complex relationship between decorin exposure and altered tissue mechanics.
- 7 July 2025
- Published by Springer Nature in European Spine Journal
- p. 1-10
The influence of decorin, a potential pro-inflammatory stimulant, on the mechanical properties of the annulus fibrosus
Purpose Structural disruption of the intervertebral disc can result in fragmentation of extracellular matrix components such as decorin, which has the capacity to mount an inflammatory response. However, it is unknown if decorin also alters the biomechanical properties of the intervertebral disc, and specifically the annulus fibrosus. Therefore, the purpose of this study was to investigate the potential of decorin to stimulate a pro-inflammatory environment and alter the mechanical integrity and tensile properties of a rat tail annulus. Methods Sixty annulus fibrosus rings were dissected from 15 rat tails and randomized into three culture conditions: (i) control; (ii) 0.5 µg/mL bovine decorin (low dose); (iii) 5 µg/mL bovine decorin (high dose). Samples were cultured for 6 days then tested via a tensile mechanical testing system. IL-6 and MIP-2 concentration in the culture media were quantified via enzyme-linked immunosorbent assays at day 6. Results IL-6 and MIP-2 were present in the media after six days of culture but did not differ between conditions. Decorin did, however, impact a number of tensile properties of the annulus. Specifically, the high dose of decorin resulted in greater toe region strain (p < 0.001) and greater failure strain (p < 0.001) as well as greater initial failure stress (p = 0.024) and maximum stress (p = 0.001). Discussion The observed increase in annulus strength may be a result of reorganization of the load-bearing collagen fibres while the increased strain may be due to degradation of other matrix proteins. Future work is necessary to further elucidate the complex relationship between decorin exposure and altered tissue mechanics.
- 4 July 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (9) , 1-17
A New Slant on Shear Loading: Uncovering Its Effect on the Intervertebral Disc
Prolonged anterior shear loading may contribute to disc degeneration by damaging the annulus fibrosus. To address this, annular mechanical properties were quantified following static shear loading using a porcine model. Twelve porcine cervical motion segments were dissected, with posterior bony elements removed to isolate shear to the intervertebral disc. Specimens were randomized into two conditions: (1) shear-loaded (100 N static anterior shear applied to C3/C4, n = 6) or (2) control (0 N, n = 6). Shear force was applied via a pin through C4, secured to a testing system to prevent rotation, while C3 was clamped such that anterior shear of C3 with respect to C4 resulted. Following 1 h of loading, two anterior annulus samples were extracted per specimen. The first sample underwent circumferential tensile testing, while the other was prepared for a peel test to assess interlamellar adhesion. Tensile properties in the circumferential direction remained unchanged after shear loading. However, interlamellar adhesive stiffness decreased by 52% (p = 0.02), and adhesive strength dropped by 46% (p = 0.02) in shear-loaded specimens compared to controls. Shear loading weakened the interlamellar matrix, reducing resistance to delamination and compromising disc integrity. These findings suggest that prolonged shear loading may contribute to early-stage disc damage.
- 4 July 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (9) , 1-17
A New Slant on Shear Loading: Uncovering Its Effect on the Intervertebral Disc
Prolonged anterior shear loading may contribute to disc degeneration by damaging the annulus fibrosus. To address this, annular mechanical properties were quantified following static shear loading using a porcine model. Twelve porcine cervical motion segments were dissected, with posterior bony elements removed to isolate shear to the intervertebral disc. Specimens were randomized into two conditions: (1) shear-loaded (100 N static anterior shear applied to C3/C4, n = 6) or (2) control (0 N, n = 6). Shear force was applied via a pin through C4, secured to a testing system to prevent rotation, while C3 was clamped such that anterior shear of C3 with respect to C4 resulted. Following 1 h of loading, two anterior annulus samples were extracted per specimen. The first sample underwent circumferential tensile testing, while the other was prepared for a peel test to assess interlamellar adhesion. Tensile properties in the circumferential direction remained unchanged after shear loading. However, interlamellar adhesive stiffness decreased by 52% (p = 0.02), and adhesive strength dropped by 46% (p = 0.02) in shear-loaded specimens compared to controls. Shear loading weakened the interlamellar matrix, reducing resistance to delamination and compromising disc integrity. These findings suggest that prolonged shear loading may contribute to early-stage disc damage.
- Open Access
- 8 May 2025
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 13, 1468926
Skeletal growth and development dictate the processes of vertebral fracture in the pediatric spine; a review emphasizing fracture biomechanics of the vertebral body during the period of skeletal immaturity
Infancy, childhood, and adolescence involve changing body proportions, muscular strength, and the complex processes of skeletal growth, contributing to a unique subset of biomechanical considerations when vertebral fractures result from falls from height, motor vehicle accidents, nonaccidental injuries, and sport and manual labour. In this review, the biomechanics of compression fractures, burst fractures, seatbelt syndrome, nonaccidental trauma, defects of the vertebral endplate, and ring apophysis fractures are all detailed regarding their manifestation in the pediatric spine. Interactions between pediatric diseases, the intervertebral disc, and the spine's facet joints are also briefly discussed, lending additional context toward the unique etiologies of pediatric vertebral fracture. The present narrative review seeks to provide a detailed overview of the key relationships responsible for the unique biomechanical considerations governing vertebral and endplate fracture, in the pediatric population.
- 8 May 2025
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 13, 1468926
Open AccessSkeletal growth and development dictate the processes of vertebral fracture in the pediatric spine; a review emphasizing fracture biomechanics of the vertebral body during the period of skeletal immaturity
Infancy, childhood, and adolescence involve changing body proportions, muscular strength, and the complex processes of skeletal growth, contributing to a unique subset of biomechanical considerations when vertebral fractures result from falls from height, motor vehicle accidents, nonaccidental injuries, and sport and manual labour. In this review, the biomechanics of compression fractures, burst fractures, seatbelt syndrome, nonaccidental trauma, defects of the vertebral endplate, and ring apophysis fractures are all detailed regarding their manifestation in the pediatric spine. Interactions between pediatric diseases, the intervertebral disc, and the spine's facet joints are also briefly discussed, lending additional context toward the unique etiologies of pediatric vertebral fracture. The present narrative review seeks to provide a detailed overview of the key relationships responsible for the unique biomechanical considerations governing vertebral and endplate fracture, in the pediatric population.
- Open Access
- 15 April 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107015
Mechanical age-related differences in the human cadaveric annulus fibrosus
- 15 April 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107015
Open AccessMechanical age-related differences in the human cadaveric annulus fibrosus
- Open Access
- 22 January 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 122, 106441
An investigation of the mechanism of adjacent segment disease in a porcine spine model
- 22 January 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 122, 106441
Open AccessAn investigation of the mechanism of adjacent segment disease in a porcine spine model
- Open Access
- 3 January 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (2) , 1-11
Does Annulus Fibrosus Lamellar Adhesion Testing Require Preconditioning?
The interlamellar matrix (ILM), located between the annular layers of the intervertebral disc (IVD), is an adhesive component which acts to resist delamination. Investigating the mechanical properties of the ILM can provide us with valuable information regarding risk of disc injury; however given its viscoelastic nature, it may be necessary to conduct preconditioning on tissue samples before measuring these ILM properties. Therefore, the aim of this study was to optimize mechanical testing protocols of the ILM by examining the effect of preconditioning on stiffness and strength of this adhesive matrix. Eighty-eight annular samples were dissected from 22 porcine cervical discs and randomized into one of four testing conditions consisting of ten cycles of 15% strain followed by a 180 deg adhesive peel test. The four testing groups employed a different strain rate for the ten cycles of preconditioning: 0.01 mm/s (n = 23); 0.1 mm/s (n = 26); 1 mm/s (n = 23); and no preconditioning employed (n = 16). Samples preconditioned at 0.01 mm/s were significantly less stiff than those that had not received preconditioning (p = 0.014). No other results were found to be statistically significant. Given the lack of differences observed in this study, preconditioning is likely not necessary prior to conducting a 180 deg peel test. However, if preconditioning is employed, the findings from this study suggest avoiding preconditioning conducted at very slow rates (i.e., 0.01 mm/s) as the long testing time may negatively affect the tissue.
- 3 January 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (2) , 1-11
Open AccessDoes Annulus Fibrosus Lamellar Adhesion Testing Require Preconditioning?
The interlamellar matrix (ILM), located between the annular layers of the intervertebral disc (IVD), is an adhesive component which acts to resist delamination. Investigating the mechanical properties of the ILM can provide us with valuable information regarding risk of disc injury; however given its viscoelastic nature, it may be necessary to conduct preconditioning on tissue samples before measuring these ILM properties. Therefore, the aim of this study was to optimize mechanical testing protocols of the ILM by examining the effect of preconditioning on stiffness and strength of this adhesive matrix. Eighty-eight annular samples were dissected from 22 porcine cervical discs and randomized into one of four testing conditions consisting of ten cycles of 15% strain followed by a 180 deg adhesive peel test. The four testing groups employed a different strain rate for the ten cycles of preconditioning: 0.01 mm/s (n = 23); 0.1 mm/s (n = 26); 1 mm/s (n = 23); and no preconditioning employed (n = 16). Samples preconditioned at 0.01 mm/s were significantly less stiff than those that had not received preconditioning (p = 0.014). No other results were found to be statistically significant. Given the lack of differences observed in this study, preconditioning is likely not necessary prior to conducting a 180 deg peel test. However, if preconditioning is employed, the findings from this study suggest avoiding preconditioning conducted at very slow rates (i.e., 0.01 mm/s) as the long testing time may negatively affect the tissue.
- Open Access
- 19 December 2024
- Published by Elsevier in Clinical Biomechanics
- Vol. 122, 106425
Mechanical function of the annulus fibrosus is preserved following quasi-static compression resulting in endplate fracture
- 19 December 2024
- Published by Elsevier in Clinical Biomechanics
- Vol. 122, 106425
Open AccessMechanical function of the annulus fibrosus is preserved following quasi-static compression resulting in endplate fracture
- Open Access
- 13 June 2024
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 130 (1) , 104194
Mechanical consequences to the annulus fibrosus following rapid internal pressurization and endplate fracture under restrained-expansion conditions
Intervertebral disc herniation is not a common injury in the adolescent population, but the correlation between trauma and herniation warrants concern. Previous research demonstrated the capacity for rapid internal pressurization to reduce the mechanical integrity of the intervertebral disc's annulus fibrosus, even in the absence of fracture. The purpose of this study was to modify previous internal pressurization procedures towards a more transferable injury model, then investigate the capacity for these procedures to damage the mechanical integrity of the annulus fibrosus. Porcine cervical motion segments with intact facet joints were confined between a vice and force plate under 300 N of static compression, then a single, manual, rapid internal pressurization was delivered. Posterolateral annulus samples were extracted and situated in a 180° peel test configuration, exposing the interlamellar matrix of samples to separations of 0.5 mm/s, until complete separation of the sample occurred. Multilayer tensile testing was performed on superficial and mid-span samples of annulus by applying uniaxial tension of 1 %/s to 50 % strain. Compared to unpressurized controls, rapid pressurization causing fracture resulted in reduced lamellar adhesion and increased toe-region stress and strain properties in the annulus. Morphological assessment reported similar fracture patterns between endplate fractures achieved in the present experiment and endplate fractures documented in human patients. Mechanical plus morphological results suggest that rapid internal pressurization resulting in endplate fracture may represent a potent mechanism for subsequent damage to the intervertebral disc.
- 13 June 2024
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 130 (1) , 104194
Open AccessMechanical consequences to the annulus fibrosus following rapid internal pressurization and endplate fracture under restrained-expansion conditions
Intervertebral disc herniation is not a common injury in the adolescent population, but the correlation between trauma and herniation warrants concern. Previous research demonstrated the capacity for rapid internal pressurization to reduce the mechanical integrity of the intervertebral disc's annulus fibrosus, even in the absence of fracture. The purpose of this study was to modify previous internal pressurization procedures towards a more transferable injury model, then investigate the capacity for these procedures to damage the mechanical integrity of the annulus fibrosus. Porcine cervical motion segments with intact facet joints were confined between a vice and force plate under 300 N of static compression, then a single, manual, rapid internal pressurization was delivered. Posterolateral annulus samples were extracted and situated in a 180° peel test configuration, exposing the interlamellar matrix of samples to separations of 0.5 mm/s, until complete separation of the sample occurred. Multilayer tensile testing was performed on superficial and mid-span samples of annulus by applying uniaxial tension of 1 %/s to 50 % strain. Compared to unpressurized controls, rapid pressurization causing fracture resulted in reduced lamellar adhesion and increased toe-region stress and strain properties in the annulus. Morphological assessment reported similar fracture patterns between endplate fractures achieved in the present experiment and endplate fractures documented in human patients. Mechanical plus morphological results suggest that rapid internal pressurization resulting in endplate fracture may represent a potent mechanism for subsequent damage to the intervertebral disc.