Robert Hartmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert Hartmann has a total of 329 co-authors. Here are the top co-authors by number of shared publications:
- Michael Meyer
European XFEL, Schenefeld, Germany
5 shared publications - Daniela Rupp
Laboratory for Solid State Physics ETH Zurich 8093 Zürich Switzerland
4 shared publications Heike Soltau
4 shared publicationsLothar Strüder
PNSensor GmbH, Otto Hahn Ring 6, D-81739 Munich, Germany
4 shared publications- Peter Holl
PNSensor GmbH, Otto-Hahn-Ring 6, 81739 München, Germany
4 shared publications - Yevheniy Ovcharenko
European XFEL, Schenefeld, Germany
4 shared publications
Latest Publications
- Open Access
- 3 September 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Model-free pattern separation of two-color ultrafast X-ray diffraction
Two-color X-ray imaging with Free Electron Laser pulses offers a powerful approach for probing ultrafast structural dynamics in nanoscale systems, combining (near-)atomic spatial resolution with femtosecond temporal precision. The first X-ray pulse captures the object’s initial state, while the second, time-delayed pulse records its subsequent evolution. A key challenge lies in disentangling the two patterns simultaneously recorded by the same detector. We demonstrate the realization of this approach on structurally varying nanoscale particles using two X-ray pulses of different photon energies, 1 and 1.2 keV. Sub-micrometer helium nanodroplets generated in vacuum are irradiated by the two X-ray pulses separated in time by up to 750 femtoseconds. Taking advantage of the high photon-energy resolution of the imaging detector, we separate the overlapping diffraction signals by analyzing individual pixel counts and applying pattern recognition. The helium nanodroplets’ spherical shape allows us to cross-validate this approach by fitting the radial scattering profiles with Mie solutions for abichromatic field. The excellent agreement between the two methods, particularly in the sparsely illuminated outer regions of the diffraction patterns where high-resolution structural information is encoded, highlights the quality of this approach and its potential for future advanced X-ray movie techniques.
- 3 September 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessModel-free pattern separation of two-color ultrafast X-ray diffraction
Two-color X-ray imaging with Free Electron Laser pulses offers a powerful approach for probing ultrafast structural dynamics in nanoscale systems, combining (near-)atomic spatial resolution with femtosecond temporal precision. The first X-ray pulse captures the object’s initial state, while the second, time-delayed pulse records its subsequent evolution. A key challenge lies in disentangling the two patterns simultaneously recorded by the same detector. We demonstrate the realization of this approach on structurally varying nanoscale particles using two X-ray pulses of different photon energies, 1 and 1.2 keV. Sub-micrometer helium nanodroplets generated in vacuum are irradiated by the two X-ray pulses separated in time by up to 750 femtoseconds. Taking advantage of the high photon-energy resolution of the imaging detector, we separate the overlapping diffraction signals by analyzing individual pixel counts and applying pattern recognition. The helium nanodroplets’ spherical shape allows us to cross-validate this approach by fitting the radial scattering profiles with Mie solutions for abichromatic field. The excellent agreement between the two methods, particularly in the sparsely illuminated outer regions of the diffraction patterns where high-resolution structural information is encoded, highlights the quality of this approach and its potential for future advanced X-ray movie techniques.
- 21 July 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1092
Development and evaluation of a CNN-based charged-particle event rejection algorithm for soft X-ray detection in a pnCCD-based satellite system
- 21 July 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1092
Development and evaluation of a CNN-based charged-particle event rejection algorithm for soft X-ray detection in a pnCCD-based satellite system
- Open Access
- 24 June 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Dichography: two-frame ultrafast imaging from a single diffraction pattern
We experimentally demonstrate that pairs of time-delayed ultrabright and ultrashort X-ray pulses of two different colors, delivered by modern X-ray Free Electron Lasers, can provide two time-delayed snapshots of a sample. We introduce Dichography, a method that algorithmically separates the diffraction signals overlapping on the detector and independently retrieves the two images of the specimen. We employ Dichography to reconstruct two views of individual xenon-doped helium nanodroplets with 20 nm spatial resolution. The consistency of structures observed in both images at delays up to 750 fs provides evidence that, under these illumination conditions, significant structural damage only occurs at longer timescales. We further validate the method by imaging pairs of silver nanoparticles intercepted by the same light pulse. Dichography enables a new class of experiments across physics, chemistry, and materials science, making a significant step toward the original promise of X-ray free-electron lasers to capture ultrafast movies of nanomatter.
- 24 June 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessDichography: two-frame ultrafast imaging from a single diffraction pattern
We experimentally demonstrate that pairs of time-delayed ultrabright and ultrashort X-ray pulses of two different colors, delivered by modern X-ray Free Electron Lasers, can provide two time-delayed snapshots of a sample. We introduce Dichography, a method that algorithmically separates the diffraction signals overlapping on the detector and independently retrieves the two images of the specimen. We employ Dichography to reconstruct two views of individual xenon-doped helium nanodroplets with 20 nm spatial resolution. The consistency of structures observed in both images at delays up to 750 fs provides evidence that, under these illumination conditions, significant structural damage only occurs at longer timescales. We further validate the method by imaging pairs of silver nanoparticles intercepted by the same light pulse. Dichography enables a new class of experiments across physics, chemistry, and materials science, making a significant step toward the original promise of X-ray free-electron lasers to capture ultrafast movies of nanomatter.
- Open Access
- 1 November 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (11)
The x-ray color camera microscope—A combined x-ray diffraction and fluorescence analysis instrument suitable for lab and synchrotron use
X-ray spectroscopy has been among the most important and precise material characterization techniques for multiple decades, with a wide range of applications from material sciences to medical research or cultural heritage. With the rising capabilities of laboratory x-ray sources and novel detectors, new techniques become possible. The x-ray Color Camera Microscope combines a state-of-the-art laboratory source with a large, pixelated energy dispersive pnCCD detector, where every pixel yields an independent energy spectrum. In addition, it can be used at a synchrotron as well, in case higher flux is needed. The full beam path is in vacuum and the detector completely unshielded, guaranteeing the detection of low energy photons and effectively minimizing parasitic background scattering and absorption. Very high scattering angles up to 70° can be reached by moving the detector very close to the sample, making it useful for a variety of techniques. Two techniques will be presented, both profiting from the special setup of the instrument. Full-field fluorescence imaging can yield a spatially resolved elemental map of a sample without the need of scanning it with a microscopic beam. Energy dispersive Laue diffraction uses a polychromatic beam and allows three-dimensional crystallographic data of a sample to be obtained in a single shot. With the above options and the possibility of other techniques, the x-ray Color Camera Microscope becomes a versatile energy dispersive x-ray imaging instrument for use in the laboratory and at synchrotrons.
- 1 November 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (11)
Open AccessThe x-ray color camera microscope—A combined x-ray diffraction and fluorescence analysis instrument suitable for lab and synchrotron use
X-ray spectroscopy has been among the most important and precise material characterization techniques for multiple decades, with a wide range of applications from material sciences to medical research or cultural heritage. With the rising capabilities of laboratory x-ray sources and novel detectors, new techniques become possible. The x-ray Color Camera Microscope combines a state-of-the-art laboratory source with a large, pixelated energy dispersive pnCCD detector, where every pixel yields an independent energy spectrum. In addition, it can be used at a synchrotron as well, in case higher flux is needed. The full beam path is in vacuum and the detector completely unshielded, guaranteeing the detection of low energy photons and effectively minimizing parasitic background scattering and absorption. Very high scattering angles up to 70° can be reached by moving the detector very close to the sample, making it useful for a variety of techniques. Two techniques will be presented, both profiting from the special setup of the instrument. Full-field fluorescence imaging can yield a spatially resolved elemental map of a sample without the need of scanning it with a microscopic beam. Energy dispersive Laue diffraction uses a polychromatic beam and allows three-dimensional crystallographic data of a sample to be obtained in a single shot. With the above options and the possibility of other techniques, the x-ray Color Camera Microscope becomes a versatile energy dispersive x-ray imaging instrument for use in the laboratory and at synchrotrons.
- Open Access
- 3 May 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1064
Radiation tolerance test and performance verification of pnCCD at high temperatures for future satellite mission HiZ-GUNDAM
- 3 May 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1064
Open AccessRadiation tolerance test and performance verification of pnCCD at high temperatures for future satellite mission HiZ-GUNDAM
- Top Cited PapersOpen Access
- 12 January 2024
- Published by Springer Nature in Light: Science & Applications
- Vol. 13 (1) , 1-11
Observation of a single protein by ultrafast X-ray diffraction
The idea of using ultrashort X-ray pulses to obtain images of single proteins frozen in time has fascinated and inspired many. It was one of the arguments for building X-ray free-electron lasers. According to theory, the extremely intense pulses provide sufficient signal to dispense with using crystals as an amplifier, and the ultrashort pulse duration permits capturing the diffraction data before the sample inevitably explodes. This was first demonstrated on biological samples a decade ago on the giant mimivirus. Since then, a large collaboration has been pushing the limit of the smallest sample that can be imaged. The ability to capture snapshots on the timescale of atomic vibrations, while keeping the sample at room temperature, may allow probing the entire conformational phase space of macromolecules. Here we show the first observation of an X-ray diffraction pattern from a single protein, that of Escherichia coli GroEL which at 14 nm in diameter is the smallest biological sample ever imaged by X-rays, and demonstrate that the concept of diffraction before destruction extends to single proteins. From the pattern, it is possible to determine the approximate orientation of the protein. Our experiment demonstrates the feasibility of ultrafast imaging of single proteins, opening the way to single-molecule time-resolved studies on the femtosecond timescale.
- 12 January 2024
- Published by Springer Nature in Light: Science & Applications
- Vol. 13 (1) , 1-11
Top Cited PapersOpen AccessObservation of a single protein by ultrafast X-ray diffraction
The idea of using ultrashort X-ray pulses to obtain images of single proteins frozen in time has fascinated and inspired many. It was one of the arguments for building X-ray free-electron lasers. According to theory, the extremely intense pulses provide sufficient signal to dispense with using crystals as an amplifier, and the ultrashort pulse duration permits capturing the diffraction data before the sample inevitably explodes. This was first demonstrated on biological samples a decade ago on the giant mimivirus. Since then, a large collaboration has been pushing the limit of the smallest sample that can be imaged. The ability to capture snapshots on the timescale of atomic vibrations, while keeping the sample at room temperature, may allow probing the entire conformational phase space of macromolecules. Here we show the first observation of an X-ray diffraction pattern from a single protein, that of Escherichia coli GroEL which at 14 nm in diameter is the smallest biological sample ever imaged by X-rays, and demonstrate that the concept of diffraction before destruction extends to single proteins. From the pattern, it is possible to determine the approximate orientation of the protein. Our experiment demonstrates the feasibility of ultrafast imaging of single proteins, opening the way to single-molecule time-resolved studies on the femtosecond timescale.
- Open Access
- 16 August 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (7) , 076002
Generation of Large Vortex-Free Superfluid Helium Nanodroplets
Superfluid helium nanodroplets are an ideal environment for the formation of metastable, self-organized dopant nanostructures. However, the presence of vortices often hinders their formation. Here, we demonstrate the generation of vortex-free helium nanodroplets and explore the size range in which they can be produced. From x-ray diffraction images of xenon-doped droplets, we identify that single compact structures, assigned to vortex-free aggregation, prevail up to atoms per droplet. This finding builds the basis for exploring the assembly of far-from-equilibrium nanostructures at low temperatures.- 16 August 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (7) , 076002
Open AccessGeneration of Large Vortex-Free Superfluid Helium Nanodroplets
Superfluid helium nanodroplets are an ideal environment for the formation of metastable, self-organized dopant nanostructures. However, the presence of vortices often hinders their formation. Here, we demonstrate the generation of vortex-free helium nanodroplets and explore the size range in which they can be produced. From x-ray diffraction images of xenon-doped droplets, we identify that single compact structures, assigned to vortex-free aggregation, prevail up to atoms per droplet. This finding builds the basis for exploring the assembly of far-from-equilibrium nanostructures at low temperatures. - 28 January 2022
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 156 (4) , 041102
Sizes of pure and doped helium droplets from single shot x-ray imaging
Advancements in x-ray free-electron lasers on producing ultrashort, ultrabright, and coherent x-ray pulses enable single-shot imaging of fragile nanostructures, such as superfluid helium droplets. This imaging technique gives unique access to the sizes and shapes of individual droplets. In the past, such droplet characteristics have only been indirectly inferred by ensemble averaging techniques. Here, we report on the size distributions of both pure and doped droplets collected from single-shot x-ray imaging and produced from the free-jet expansion of helium through a 5 μm diameter nozzle at 20 bars and nozzle temperatures ranging from 4.2 to 9 K. This work extends the measurement of large helium nanodroplets containing 109–1011 atoms, which are shown to follow an exponential size distribution. Additionally, we demonstrate that the size distributions of the doped droplets follow those of the pure droplets at the same stagnation condition but with smaller average sizes.
- 28 January 2022
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 156 (4) , 041102
Sizes of pure and doped helium droplets from single shot x-ray imaging
Advancements in x-ray free-electron lasers on producing ultrashort, ultrabright, and coherent x-ray pulses enable single-shot imaging of fragile nanostructures, such as superfluid helium droplets. This imaging technique gives unique access to the sizes and shapes of individual droplets. In the past, such droplet characteristics have only been indirectly inferred by ensemble averaging techniques. Here, we report on the size distributions of both pure and doped droplets collected from single-shot x-ray imaging and produced from the free-jet expansion of helium through a 5 μm diameter nozzle at 20 bars and nozzle temperatures ranging from 4.2 to 9 K. This work extends the measurement of large helium nanodroplets containing 109–1011 atoms, which are shown to follow an exponential size distribution. Additionally, we demonstrate that the size distributions of the doped droplets follow those of the pure droplets at the same stagnation condition but with smaller average sizes.
- 1 January 2022
- Published by Carl Hanser Verlag in Zeitschrift Kunststofftechnik
- Vol. 1, 202-233
Entwicklung eines Herstellungsprozesses für umweltfreundliche und ressourceneffiziente Formteile aus lastgerecht verstärkten Holz-Kunststoff-Verbunden
Mit Hilfe von CFD-Simulationen wird im Rahmen dieses Beitrages ein Düsensystem (Aufsatz-Düse) für das Heißgasschweißen entwickelt, welches die Schweißnaht während der Erwärmung umschließt. Durch das wesentlich kontrolliertere Strömungsverhalten des H …
- 1 January 2022
- Published by Carl Hanser Verlag in Zeitschrift Kunststofftechnik
- Vol. 1, 202-233
Entwicklung eines Herstellungsprozesses für umweltfreundliche und ressourceneffiziente Formteile aus lastgerecht verstärkten Holz-Kunststoff-Verbunden
Mit Hilfe von CFD-Simulationen wird im Rahmen dieses Beitrages ein Düsensystem (Aufsatz-Düse) für das Heißgasschweißen entwickelt, welches die Schweißnaht während der Erwärmung umschließt. Durch das wesentlich kontrolliertere Strömungsverhalten des H …
- Open Access
- 1 February 2021
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 54 (1) , 80-86
Energy-dispersive X-ray micro Laue diffraction on a bent gold nanowire
This article reports on energy-dispersive micro Laue (µLaue) diffraction of an individual gold nanowire that was mechanically deformed in three-point bending geometry using an atomic force microscope. The nanowire deformation was investigated by scanning the focused polychromatic X-ray beam along the nanowire and recording µLaue diffraction patterns using an energy-sensitive pnCCD detector that permits measurement of the angular positions of the Laue spots and the energies of the diffracted X-rays simultaneously. The plastic deformation of the nanowire was shown by a bending of up to 3.0 ± 0.1°, a torsion of up to 0.3 ± 0.1° and a maximum deformation depth of 80 ± 5 nm close to the position where the mechanical load was applied. In addition, extended Laue spots in the vicinity of one of the clamping points indicated the storage of geometrically necessary dislocations with a density of 7.5 × 1013 m−2. While µLaue diffraction with a non-energy-sensitive detector only gives access to the deviatoric strain, the energy sensitivity of the employed pnCCD offers absolute strain measurements with a resolution of 1%. Here, the residual strain after complete unloading of the nanowire amounted to maximum tensile and compressive strains of the order of +1.2 and −3%, which is comparable to the actual resolution limit. The combination of white-beam µLaue diffraction using an energy-sensitive pixel detector with nano-mechanical testing opens up new possibilities for the study of mechanical behavior at the nanoscale.
- 1 February 2021
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 54 (1) , 80-86
Open AccessEnergy-dispersive X-ray micro Laue diffraction on a bent gold nanowire
This article reports on energy-dispersive micro Laue (µLaue) diffraction of an individual gold nanowire that was mechanically deformed in three-point bending geometry using an atomic force microscope. The nanowire deformation was investigated by scanning the focused polychromatic X-ray beam along the nanowire and recording µLaue diffraction patterns using an energy-sensitive pnCCD detector that permits measurement of the angular positions of the Laue spots and the energies of the diffracted X-rays simultaneously. The plastic deformation of the nanowire was shown by a bending of up to 3.0 ± 0.1°, a torsion of up to 0.3 ± 0.1° and a maximum deformation depth of 80 ± 5 nm close to the position where the mechanical load was applied. In addition, extended Laue spots in the vicinity of one of the clamping points indicated the storage of geometrically necessary dislocations with a density of 7.5 × 1013 m−2. While µLaue diffraction with a non-energy-sensitive detector only gives access to the deviatoric strain, the energy sensitivity of the employed pnCCD offers absolute strain measurements with a resolution of 1%. Here, the residual strain after complete unloading of the nanowire amounted to maximum tensile and compressive strains of the order of +1.2 and −3%, which is comparable to the actual resolution limit. The combination of white-beam µLaue diffraction using an energy-sensitive pixel detector with nano-mechanical testing opens up new possibilities for the study of mechanical behavior at the nanoscale.