MMMiguel J. Maldonado

Miguel J. Maldonado

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Miguel J. Maldonado has a total of 234 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Senile Cataract Formation Does Not Affect Crystalline Lens Thickness

    by Alberto López-De la Rosa, Cecilia Díez-Montero, Elena Martínez-Plaza, Alberto López-Miguel, Miguel J. Maldonado

    Introduction Characterizing lens thickness (LT) in patients with cataracts is important for better understanding the lens aging process and for designing new intraocular lens power formulas. This study aimed to analyze the influence of common senile cataract formation on the LT, anterior (ACS) and posterior (PCS) cortex space, and nuclear thickness (NT), controlling for sex, age, and axial length. Methods A cross-sectional study was performed. A consecutive sample of 603 volunteers (403 women, 200 men) aged 59.1 ± 18.8 years was recruited. The standardized Lens Opacification Classification System (LOCS)-III was used to classify eyes (randomly selected) into cataractous and non-cataractous groups. Also, they were classified according to the cataract location (presence or absence of cortical, nuclear, or posterior subcapsular cataract). Optical biometry was performed to measure LT, ACS, NT, and PCS. Propensity score was used to match participants one-to-one for sex, age, and axial length. Groups were compared using the Student’s t test or Yuen’s test. Results The four classifications divided unmatched eyes into: 361 cataractous lenses and 242 non-cataractous, 226 cortical and 377 non-cortical cataractous, 313 nuclear and 290 non-nuclear cataractous and 242 subcapsular and 361 non-subcapsular cataractous. Before matching, cataractous eyes showed significantly higher LT (4.52 ± 0.39 vs. 3.94 ± 0.46 mm, p < 0.001), ACS (0.75 ± 0.20 vs. 0.58 ± 0.23 mm, p < 0.001), NT (3.34 ± 0.23 vs. 3.18 ± 0.25 mm, p < 0.001) and PCS (0.42 ± 0.19 vs. 0.37 ± 0.19 mm, p = 0.003). Matched lens, cortical, nuclear, and subcapsular cataract samples comprised 146, 258, 182, and 226 eyes, respectively. After matching, no significant differences were observed in LT (4.34 ± 0.37 vs. 4.33 ± 0.36 mm, p = 0.94), ACS (0.72 ± 0.20 vs. 0.76 ± 0.19 mm, p = 0.08), NT (3.31 ± 0.22 vs. 3.30 ± 0.23 mm, p = 0.24) and PCS (0.42 ± 0.19 vs. 0.43 ± 0.16 mm, p = 0.79). Conclusions The presence of senile cortical, nuclear, and posterior subcapsular cataract have no effect on LT, ACS, NT, and PCS. Confounding factors should be controlled for when measuring LT and its main components.


  • Assessment of the iridocorneal angle pigmentation and structures after the implantation of EVO+ Visian Implantable Collamer Lens

    by Elena Martínez-Plaza, Alberto López-De la Rosa, Carolina Ossa-Calderon, Francisco Blázquez-Arauzo, Alberto López-Miguel, Miguel J. Maldonado

    Purpose To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures. Methods Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy. A masked observer, blinded to study visits and patients’ information, evaluated the angle width, apparent iris root insertion, iris configuration, and trabecular meshwork pigmentation according to the Spaeth scale in two different occasions. The intra-rater reliability was estimated using the weighted Gwet's Agreement Coefficient (AC2). Differences between visits were analyzed using the Cochran Q test or the Friedman test. Results Twenty-one patients (13 females and 8 males) aging 31.3 ± 6.3 years old were recruited. The intra-rater reliability of gonioscopy assessment was excellent for every parameter assessed (AC2 ≥ 0.97). No significant differences were found among the study visits for any quadrant in the angle width (p ≥ 0.74), apparent iris root insertion (p ≥ 0.22), iris configuration (p ≥ 0.21) and trabecular meshwork pigmentation (p ≥ 0.24). Mean pigmentation of trabecular meshwork for the four quadrants did not vary either among visits (p = 0.25). Conclusions The EVO+ ICL implantation after uneventful procedures appears not to clinically affect the iridocorneal angle pigmentation and/or structures during a short-medium follow-up using gonioscopy assessment. The intra-rater reliability of glaucoma specialists assessing iridocorneal angle structures using gonioscopy images is very high.


  • Open Access

    Relationship between the main components of the crystalline lens and the anterior chamber depth after cataract formation

    by Cecilia Díez-Montero, Alberto López-De la Rosa, Alberto López-Miguel, Miguel J. Maldonado

    Purpose: To assess the relationship between anterior chamber depth (ACD) and lens thickness (LT), as well as its three main components (anterior and posterior cortex and nucleus thickness), in cataractous and non-cataractous eyes, depending on the axial length (AxL). Methods: Anterior and posterior cortex and nucleus thickness of the crystalline lens, ACD, and AxL were measured using optical low-coherence reflectometry in cataractous and non-cataractous eyes. They were also classified into hyperopia, emmetropia, myopia, and high myopia, depending on AxL; thus, eight subgroups were created. A minimum sample size of 44 eyes (of 44 patients) for each group was recruited. Linear models were fitted for the whole sample and each AxL subgroup to assess if there were differences in the relationships between the crystalline lens variables and ACD, including age as a covariate. Results: Three hundred seventy cataract patients (237 females, 133 males) and 250 non-cataract controls (180 females, 70 males), aged 70.5 ± 9.4 and 41.9 ± 15.5 years, respectively, were recruited. The mean AxL, ACD, and LT for the cataractous and non-cataractous eyes were 23.90 ± 2.05, 24.11 ± 2.11, 2.64 ± 0.45, and 2.91 ± 0.49, 4.51 ± 0.38, 3.93 ± 0.44 mm, respectively. The inverse relationship of LT, anterior and posterior cortex, and nucleus thickness with ACD was not significantly (p ≥ 0.26) different between cataractous and non-cataractous eyes. Further subclassification of the sample depending on AxL showed that the inverse relationship between the posterior cortex and ACD was no longer significant (p > 0.05) for any non-cataractous AxL group. LT, anterior and posterior cortex, and nucleus thickness was not significantly (p ≥ 0.43) different between cataractous and non-cataractous eyes for the whole sample, and all AxL groups after adjusting for age. Conclusions: The presence of cataracts does not modify the inverse relationship of the LT, anterior and posterior cortex, and nucleus with ACD. And this relationship does not seem to depend importantly on AxL. Besides, the possible differences in LT, anterior and posterior cortex, and nucleus between cataractous and non-cataractous eyes may not be caused by lens opacification, but possibly by the progressive lens growth due to aging.


  • EVO/EVO+ Visian Implantable Collamer Lenses for the correction of myopia and myopia with astigmatism

    by Elena Martínez-Plaza, Alberto López-De la Rosa, Alberto López-Miguel, Alfredo Holgueras, Miguel J. Maldonado

    Intraocular lens implantation in phakic eyes for the correction of refractive error is currently a widespread procedure. The EVO and EVO+ Visian Implantable Collamer Lenses (ICL) are two of the mos...


  • Inter-eye and postoperative prediction of vault after implantation of EVO + Visian phakic implantable collamer lens

    by Elena Martínez-Plaza, Alberto López-Miguel, Alberto López-De la Rosa, Miguel J. Maldonado

    Purpose To assess whether the postoperative outcomes of the implantation of an EVO + implantable collamer lens (ICL) in one eye can be used as a predictor of the vault of the fellow eye, and to evaluate the vault changes of the implantation in both eyes during the postoperative period. Methods A prospective study including 40 eyes of 20 patients with a bilateral EVO + ICL implantation was performed. Subjects were evaluated before the surgery and 1 day, 1 week and 1, 3 and 6 months postoperatively. Central vault was assessed using spectral-domain optical coherence tomography. The inter-eye and follow-up analyses were performed using lineal models and the Bland–Altman method. Results The vault of the first implanted eye at the 1-day visit highly predicts the vault of the second eye (R2 = .87; P < .001); the mean inter-eye difference was − 0.95 μm, and the superior and inferior limits of agreement were −50.27 μm and 148.37 μm, respectively. This relationship was maintained during the medium-term follow-up, not finding differences in the slopes among visits (P ≥ .09). A progressive decrease of vault was found during the follow-up (P < .001). Larger vault change 6 months after the surgery was associated with higher vault 1 day after the ICL implantation (R2 = .19;P = .005). Conclusion One-day postoperative vault in the first eye can help to predict the optimal ICL sizing in the second eye. Vault tends to decrease during the first 6 months after EVO + ICL implantation. Eyes with higher initial vaults will also show larger reductions during the medium-term follow-up.


  • Open Access

    New Method for the Automated Assessment of Corneal Nerve Tortuosity Using Confocal Microscopy Imaging

    by Itziar Fernández, Amanda Vázquez, Margarita Calonge, Miguel J. Maldonado, Ana de la Mata, Alberto López-Miguel

    An automated tool for corneal nerve fiber tortuosity quantification from in vivo confocal microscopy (IVCM) is described and evaluated. The method is a multi-stage process based on the splitting of the corneal nerve fibers into individual segments, whose endpoints are an extreme or intersection of white pixels on a binarized image. Individual segment tortuosity is quantified in terms of the arc-chord ratio. Forty-three IVCM images from 43 laser-assisted in situ keratomileusis (LASIK) surgery patients were used for evaluation. Images from symptomatic dry eye disease (DED) post-LASIK patients, with (n=16) and without (n=7) ocular pain, and non-DED post-LASIK controls (n=20) were assessed. The automated tortuosity measure was compared to a manual grading one, obtaining a moderate correlation (Spearman’s rank correlation coefficient = 0.49, p=0.0008). The new tortuosity index was significantly higher in post-LASIK patients with ocular pain than in control patients (p=0.001), while no significant differences were detected with manual measurement (p>0.28). The tortuosity quantification was positively correlated with the ocular surface disease index (OSDI) and a numeric rating scale (NRS) assessing pain (p=0.0012 and p=0.0051, respectively). The results show good performance of the proposed automated methodology for the evaluation of corneal nerve tortuosity.


  • Cirugía de catarata bilateral secuencia e inmediata

    by J.L. Alio, M. Gessa-Sorroche, A. Nowrouzi, M.J. Maldonado


  • Open Access

    Preliminary Evaluation of the Clinical Benefit of a Novel Visual Rehabilitation Program in Patients Implanted with Trifocal Diffractive Intraocular Lenses: A Blinded Randomized Placebo-Controlled Clinical Trial

    by David P. Piñero, Ainhoa Molina-Martin, María L. Ramón, José L. Rincón, Cristian Fernández, Dolores de Fez, Juan F. Arenillas, Luis Leal-Vega, María Begoña Coco-Martín, Miguel J. Maldonado

    The authors of this study evaluated the potential benefit on visual performance of a novel 3 week visual rehabilitation program based on the use of Gabor patches in patients undergoing bilateral cataract surgery with the implantation of two models of trifocal diffractive intraocular lens (IOL). A total of 30 patients were randomly assigned to two groups: a study group (15 patients) that used a videogame based on Gabor patches and a placebo group (15 patients) that used a videogame without specific stimuli for improving visual performance. No statistically significant differences between groups were found in distance, intermediate, and near post-training visual acuity (p ≥ 0.15). Significantly better distance contrast sensitivity (CS) was found for the spatial frequencies of 6 (p = 0.02) and 12 cpd (p = 0.01) in the study group. Likewise, significantly better values of near CS were found in the study group compared to the placebo group for the spatial frequency of 1.5 cpd (p = 0.02). In conclusion, a 3 week visual rehabilitation program based on the use of Gabor patches in the immediate postoperative period after the bilateral implantation of trifocal diffractive IOLs seems to be beneficial for improving both distance and near visual performance achieved with the implant.


  • Open Access

    Monochromatic higher order aberrations in highly myopic eyes with Staphyloma

    by Santiago Delgado-Tirado, Alberto López-Miguel, Yazmin Báez-Peralta, Lucía González-Buendía, Itziar Fernández, Jorge L. Alió, Miguel J. Maldonado, Rosa M. Coco-Martín

    Prevalence of high myopia is continuously increasing, thus, patients affected with staphyloma are abundant worldwide. Assessment of the quality of vision in these patients is mandatory for a proper clinical counselling, specially when undergoing surgical procedures that require intraocular lenses implantation. Thus, the purpose of the study was to assess monochromatic higher order aberrations (HOAs) in highly myopic eyes with staphyloma with or without a dome-shaped macula. Participants underwent spectral-domain optical coherence tomography, ocular axial biometry, dual Scheimpflug photography and integrated Placido disk topography, and Hartmann-Shack wavefront analysis. Five groups were evaluated: a low-moderate myopia control group (< 6.00 diopters, n = 31) and four high myopia (≥6.00 diopters) groups: eyes without staphyloma (n = 18), eyes with inferior staphyloma (n = 14), eyes with posterior staphyloma without dome-shaped macula (n = 15) and eyes with posterior staphyloma with dome-shaped macula (n = 17). Subsequently, two new groups (including all participants) were created to assess differences between myopia with and without staphyloma. One-way analysis of covariance was performed using age and lens densitometry as covariates. Statistically significant (p ≤ 0.05) differences in anterior corneal fourth-order HOAs were observed between the low-moderate myopia and no-dome-shaped macula (Mean: 0.16 μm) and dome-shaped macula posterior staphyloma groups (Mean: 0.12 μm) in younger patients (≤45 years old). The same groups also showed (p ≤ 0.05) significant differences for anterior corneal primary spherical aberration (Mean: 0.19 and 0.13 μm, respectively). In addition, anterior corneal tetrafoil was significantly higher (p = 0.04) in dome-shaped macula compared to no-dome-shaped macula (Mean: 0.18 vs 0.06 μm, respectively). When all participants were grouped together, significantly lower mean anterior corneal primary spherical aberration (0.15 μm vs. 0.27 μm, p = 0.004) and higher internal primary spherical aberration (0.04 μm vs. -0.06 μm, p = 0.04) was observed in staphyloma compared to no-staphyloma myopic patients. Eyes with high myopia and staphyloma have less positive anterior corneal primary spherical aberration and less negative internal primary spherical aberration, suggesting that the anterior corneal surface tends to mimic in a specular fashion the posterior pole profile. This corneal behaviour appears to change in patients older than 45 years.


  • Anterior Segment OCT: How to Choose for Your Practice

    by Miguel J. Maldonado, Melissa G. Paragua Macuri, Alfredo Holgueras