Putu Wijaya Sunu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Putu Wijaya Sunu has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Daud Simon Anakottapary
Department of Mechanical Engineering, Politeknik Negeri Bali, Kampus Bukit Jimbaran, Bali, Indonesia
8 shared publications I Made Suarta
5 shared publicationsI Dewa Gede Agus Triputra
4 shared publicationsKetut Suarsana
4 shared publications- Cornelius Bambang Dwi Kuncoro
Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology
3 shared publications I Dewa Made Cipta Santosa
3 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by Atlantis Press SARL
- p. 118-128
Implementation of an Integrated Executive Dashboard on the PPMPP Portal as a Digital Instrument for Institutional Quality Assurance at Politeknik Negeri Bali
- 7 October 2026
- Published by Atlantis Press SARL
- p. 118-128
Open AccessImplementation of an Integrated Executive Dashboard on the PPMPP Portal as a Digital Instrument for Institutional Quality Assurance at Politeknik Negeri Bali
- Open Access
- 7 October 2026
- Published by Atlantis Press SARL
- p. 272-280
Experimental Investigation of Eugenol Bio-Additive on Engine Performance of RON 92 Gasoline
- 7 October 2026
- Published by Atlantis Press SARL
- p. 272-280
Open AccessExperimental Investigation of Eugenol Bio-Additive on Engine Performance of RON 92 Gasoline
- 25 June 2026
- Published by Trans Tech Publications, Ltd. in Engineering Headway
- Vol. 38, 75-80
Preliminary Study of Eugenol Bio-Additive on Combustion Characteristics of Low Octane Fuel
Fuel characteristics are the most important thing in the combustion process. Fuel characteristics are influenced by the composition of the mixture, the molecular structure of the mixture formed, the calorific value and the evaporation temperature of the fuel. The purpose of this study was to determine the characteristics of isooctane fuel after being mixed with n-heptane and eugenol additives. This study was conducted by mixing isooctane fuel with n-heptane, at a composition of 92%v Isooctane and 8%v n-Heptane. The mixture was added with eugenol additives. Analysis tests were carried out on the molecular structure, calorific value, evaporation rate, octane number. Experimental tests were carried out to test the combustion rate. The test results were analyzed on the molecular structure. The test results showed that there was no interaction between isooctane, n-heptane and eugenol molecules. Based on these results, it was concluded that eugenol was able to increase the calorific value of isooctane-based fuel at a mixture composition of 1%v eugenol.
- 25 June 2026
- Published by Trans Tech Publications, Ltd. in Engineering Headway
- Vol. 38, 75-80
Preliminary Study of Eugenol Bio-Additive on Combustion Characteristics of Low Octane Fuel
Fuel characteristics are the most important thing in the combustion process. Fuel characteristics are influenced by the composition of the mixture, the molecular structure of the mixture formed, the calorific value and the evaporation temperature of the fuel. The purpose of this study was to determine the characteristics of isooctane fuel after being mixed with n-heptane and eugenol additives. This study was conducted by mixing isooctane fuel with n-heptane, at a composition of 92%v Isooctane and 8%v n-Heptane. The mixture was added with eugenol additives. Analysis tests were carried out on the molecular structure, calorific value, evaporation rate, octane number. Experimental tests were carried out to test the combustion rate. The test results were analyzed on the molecular structure. The test results showed that there was no interaction between isooctane, n-heptane and eugenol molecules. Based on these results, it was concluded that eugenol was able to increase the calorific value of isooctane-based fuel at a mixture composition of 1%v eugenol.
- 25 June 2026
- Published by Trans Tech Publications, Ltd. in Engineering Headway
- Vol. 38, 191-199
Effectiveness of Natural Dehumidifier Placement in Multi-Rack Turmeric Drying Cabinet: Energy Performance
The strategic integration of natural dehumidifiers in agricultural drying systems offers significant potential for enhancing energy efficiency while maintaining product quality. This study comprehensively evaluated the energy performance of natural dehumidifier placement in a multi-rack turmeric drying cabinet by comparing three configurations: without dehumidifier (baseline), dehumidifier positioned at the top, and dehumidifier positioned at the bottom of the drying chamber. The experimental setup utilized a multi-rack cabinet dryer with six trays, processing 350 grams of fresh turmeric per tray (2.1 kg total batch) over 300 minutes operation time. Energy performance parameters were calculated based on actual initial and final weights of turmeric samples, providing accurate moisture removal quantification for each configuration. Energy performance was assessed through multiple metrics including Specific Moisture Extraction Rate (SMER), Specific Energy Consumption (SEC), weight reduction percentage, final moisture content, and actual energy consumption measurements. Results demonstrated that the top-positioned dehumidifier configuration achieved superior energy performance with SMER of 0.519 kg/kWh, representing a 22.7% improvement over baseline (0.423 kg/kWh), while energy consumption decreased by 15.9% (from 3.78 to 3.18 kWh). The SEC showed remarkable improvement, reducing from 2.37 to 1.93 kWh/kg H 2 O (18.5% reduction). Total moisture removal increased by 3.3% (from 1.598 to 1.650 kg), achieving 78.6% weight reduction compared to 76.1% baseline. Most significantly, the top configuration achieved a final moisture content of 6.6% wet basis, meeting commercial standards (2 O (10.8% improvement) and 77.0% weight reduction. These findings demonstrate that natural dehumidifier placement significantly influences both energy performance and final product quality, with top positioning being the only configuration capable of achieving commercial moisture standards while delivering optimal energy efficiency in small to medium-scale turmeric drying operations.
- 25 June 2026
- Published by Trans Tech Publications, Ltd. in Engineering Headway
- Vol. 38, 191-199
Effectiveness of Natural Dehumidifier Placement in Multi-Rack Turmeric Drying Cabinet: Energy Performance
The strategic integration of natural dehumidifiers in agricultural drying systems offers significant potential for enhancing energy efficiency while maintaining product quality. This study comprehensively evaluated the energy performance of natural dehumidifier placement in a multi-rack turmeric drying cabinet by comparing three configurations: without dehumidifier (baseline), dehumidifier positioned at the top, and dehumidifier positioned at the bottom of the drying chamber. The experimental setup utilized a multi-rack cabinet dryer with six trays, processing 350 grams of fresh turmeric per tray (2.1 kg total batch) over 300 minutes operation time. Energy performance parameters were calculated based on actual initial and final weights of turmeric samples, providing accurate moisture removal quantification for each configuration. Energy performance was assessed through multiple metrics including Specific Moisture Extraction Rate (SMER), Specific Energy Consumption (SEC), weight reduction percentage, final moisture content, and actual energy consumption measurements. Results demonstrated that the top-positioned dehumidifier configuration achieved superior energy performance with SMER of 0.519 kg/kWh, representing a 22.7% improvement over baseline (0.423 kg/kWh), while energy consumption decreased by 15.9% (from 3.78 to 3.18 kWh). The SEC showed remarkable improvement, reducing from 2.37 to 1.93 kWh/kg H 2 O (18.5% reduction). Total moisture removal increased by 3.3% (from 1.598 to 1.650 kg), achieving 78.6% weight reduction compared to 76.1% baseline. Most significantly, the top configuration achieved a final moisture content of 6.6% wet basis, meeting commercial standards (2 O (10.8% improvement) and 77.0% weight reduction. These findings demonstrate that natural dehumidifier placement significantly influences both energy performance and final product quality, with top positioning being the only configuration capable of achieving commercial moisture standards while delivering optimal energy efficiency in small to medium-scale turmeric drying operations.
- Open Access
- 31 December 2025
- Published by Atlantis Press SARL
- p. 14-21
Improvement Through Optimized Natural Dehumidifier Placement in Turmeric Cabinet Dryer: Relative Humidity and Energy Analysis
- 31 December 2025
- Published by Atlantis Press SARL
- p. 14-21
Open AccessImprovement Through Optimized Natural Dehumidifier Placement in Turmeric Cabinet Dryer: Relative Humidity and Energy Analysis
- Open Access
- 10 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 128 (1) , 181-192
Experimental Study of Thermal Analysis and Friction Properties of Double Pipe Heat Exchangers for Different Spaces Between Spiral Grooves
The aims of the experiment investigate the thermal performance and the friction properties of double-pipe heat exchangers scratched by spiral grooves with various different spaces between grooves. These experiments involved the use of an aluminum pipe with outer diameter of 19.8 mm and an acrylic shell pipe with inner diameter of 27.5 mm. The depth and width of these grooves remained constant at about 0.5 mm, and 1 mm respectively. The distance between spiral groove was determined of 6, 8, 10, and 12 mm. With water as working fluid and the cold fluid Reynolds number ranging from approximately 32600 up to 44600, it was observed that grooved pipes had higher friction factors than smooth pipes. The friction factor decreases with the space between grooves increases and vice versa. Heat transfer rates in grooved pipes were 1.2–1.8 times higher than in smooth pipes. The performance of heat transfer increase with decreasing the space between grooves. The Number of Transfer Units (NTU) and effectiveness also have a good correlation with increase the Reynold number, on the other hand, a decrease of spiral groove spacing. Nusselt numbers for spiral grooved pipes were higher than for smooth pipes. These are corresponding improvements over the smooth pipe strength by 3.3% for the 6 mm groove spacing. The enhancement in Nusselt number decreased with increasing distance between grooves. This study provides insights into optimizing the spiral groove spacing in double pipe heat exchangers to enhance the performance of heat transfer with pressure drop penalty.
- 10 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 128 (1) , 181-192
Open AccessExperimental Study of Thermal Analysis and Friction Properties of Double Pipe Heat Exchangers for Different Spaces Between Spiral Grooves
The aims of the experiment investigate the thermal performance and the friction properties of double-pipe heat exchangers scratched by spiral grooves with various different spaces between grooves. These experiments involved the use of an aluminum pipe with outer diameter of 19.8 mm and an acrylic shell pipe with inner diameter of 27.5 mm. The depth and width of these grooves remained constant at about 0.5 mm, and 1 mm respectively. The distance between spiral groove was determined of 6, 8, 10, and 12 mm. With water as working fluid and the cold fluid Reynolds number ranging from approximately 32600 up to 44600, it was observed that grooved pipes had higher friction factors than smooth pipes. The friction factor decreases with the space between grooves increases and vice versa. Heat transfer rates in grooved pipes were 1.2–1.8 times higher than in smooth pipes. The performance of heat transfer increase with decreasing the space between grooves. The Number of Transfer Units (NTU) and effectiveness also have a good correlation with increase the Reynold number, on the other hand, a decrease of spiral groove spacing. Nusselt numbers for spiral grooved pipes were higher than for smooth pipes. These are corresponding improvements over the smooth pipe strength by 3.3% for the 6 mm groove spacing. The enhancement in Nusselt number decreased with increasing distance between grooves. This study provides insights into optimizing the spiral groove spacing in double pipe heat exchangers to enhance the performance of heat transfer with pressure drop penalty.
- Open Access
- 31 December 2024
- Published by Atlantis Press SARL
- p. 829-837
Development of A Tracer Study System Using Agile Approach for Meeting Key Performance Indicators
- 31 December 2024
- Published by Atlantis Press SARL
- p. 829-837
Open AccessDevelopment of A Tracer Study System Using Agile Approach for Meeting Key Performance Indicators
- Open Access
- 30 November 2024
- Published by Atlantis Press SARL
- p. 580-587
Performance of Heat Pump Drying Equipped with Natural Dehumidifier: A Review from the Perspective of Relative Humidity of the Drying Cabin
- 30 November 2024
- Published by Atlantis Press SARL
- p. 580-587
Open AccessPerformance of Heat Pump Drying Equipped with Natural Dehumidifier: A Review from the Perspective of Relative Humidity of the Drying Cabin
- Open Access
- 30 November 2024
- Published by Atlantis Press SARL
- p. 562-569
Preliminary Study on the Application of Water Spray Cooling on Solar Panel Surfaces: An Electrical Properties Perspective
- 30 November 2024
- Published by Atlantis Press SARL
- p. 562-569
Open AccessPreliminary Study on the Application of Water Spray Cooling on Solar Panel Surfaces: An Electrical Properties Perspective