Nirmal Kumar Gali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nirmal Kumar Gali has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Zhi Ning
Division of Environment and Sustainability, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong Special Administrative Region, China; Atmospheric Research Center, Guangzhou HKUST Fok Ying Tung Research Institute, Guangzhou, China
13 shared publications - Kotteazeth Srikumar
Pondicherry University
8 shared publications Zhi Ning
5 shared publicationsFenhuan Yang
4 shared publicationsSabrina Yanan Jiang
Division of Environment and Sustainability, The Hong Kong University of Science and Technology, Hong Kong; Division of Science and Technology, Beijing Normal University-Hong Kong Baptist University United International College, China
4 shared publicationsYa Wang
4 shared publications
Latest Publications
- 16 July 2026
- Published by Elsevier in Atmospheric Environment
- Vol. 383
Enhancing sensor calibration and source apportionment with size-resolved optical PM measurements in urban environments
- 16 July 2026
- Published by Elsevier in Atmospheric Environment
- Vol. 383
Enhancing sensor calibration and source apportionment with size-resolved optical PM measurements in urban environments
- Open Access
- 1 November 2025
- Published by Elsevier in Environment International
- Vol. 205, 109898
Ultra compact multi-channel particle sampler for personal exposure of particle chemical composition at hourly resolution
- 1 November 2025
- Published by Elsevier in Environment International
- Vol. 205, 109898
Open AccessUltra compact multi-channel particle sampler for personal exposure of particle chemical composition at hourly resolution
- Open Access
- 24 April 2025
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 18 (8) , 1771-1785
Performance validation and calibration conditions for novel dynamic baseline tracking air sensors in long-term field monitoring
The rapid expansion of low-cost sensor networks for air quality monitoring necessitates rigorous calibration to ensure data accuracy. Despite numerous published field calibration studies, a universal and comprehensive assessment of factors affecting sensor calibration remains elusive, leading to potential discrepancies in data quality across different networks. This study deployed eight sensor-based monitors in strategically chosen locations continuously for 2 years in Hong Kong, Macau and Shanghai. These locations covered a wide range of climatic conditions: Hong Kong's subtropical climate, Macau's similar yet distinct urban environment and Shanghai's more variable climate. Each monitor employed a dynamic baseline tracking method for the gas sensors, which isolates the concentration signals from temperature and humidity effects, enhancing the sensors' accuracy and reliability. This strategic deployment ensured that the sensors' performance and calibration processes were tested across diverse atmospheric conditions. The tests, which involved evaluating the validation performance by analysing randomly selected calibration sample subsets ranging from 1–15 d, indicated that the length of the calibration period, pollutant concentration range and time-averaging period are pivotal for sensor calibration quality. We determined that a 5–7 d calibration period minimizes calibration coefficient errors, and a wider concentration range improves the validation R2 values for all sensors, suggesting the necessity of setting specific concentration range thresholds. A time-averaging period of at least 5 min for data with 1 min resolution was recommended to enable optimal calibration in field operation. This study emphasizes the need for a comprehensive calibration assessment and the importance of considering environmental variability in the sensor calibration condition. These findings offer methodological guidance for the calibration of other sensor types, providing a reference for future research in the field of sensor calibration.
- 24 April 2025
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 18 (8) , 1771-1785
Open AccessPerformance validation and calibration conditions for novel dynamic baseline tracking air sensors in long-term field monitoring
The rapid expansion of low-cost sensor networks for air quality monitoring necessitates rigorous calibration to ensure data accuracy. Despite numerous published field calibration studies, a universal and comprehensive assessment of factors affecting sensor calibration remains elusive, leading to potential discrepancies in data quality across different networks. This study deployed eight sensor-based monitors in strategically chosen locations continuously for 2 years in Hong Kong, Macau and Shanghai. These locations covered a wide range of climatic conditions: Hong Kong's subtropical climate, Macau's similar yet distinct urban environment and Shanghai's more variable climate. Each monitor employed a dynamic baseline tracking method for the gas sensors, which isolates the concentration signals from temperature and humidity effects, enhancing the sensors' accuracy and reliability. This strategic deployment ensured that the sensors' performance and calibration processes were tested across diverse atmospheric conditions. The tests, which involved evaluating the validation performance by analysing randomly selected calibration sample subsets ranging from 1–15 d, indicated that the length of the calibration period, pollutant concentration range and time-averaging period are pivotal for sensor calibration quality. We determined that a 5–7 d calibration period minimizes calibration coefficient errors, and a wider concentration range improves the validation R2 values for all sensors, suggesting the necessity of setting specific concentration range thresholds. A time-averaging period of at least 5 min for data with 1 min resolution was recommended to enable optimal calibration in field operation. This study emphasizes the need for a comprehensive calibration assessment and the importance of considering environmental variability in the sensor calibration condition. These findings offer methodological guidance for the calibration of other sensor types, providing a reference for future research in the field of sensor calibration.
- Open Access
- 15 August 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-22
Impact and Optimization of Calibration Conditions for Air Quality Sensors in the Long-term Field Monitoring
The rapid expansion of low-cost sensor networks for air quality monitoring necessitates rigorous calibration to ensure data accuracy. Despite numerous published field calibration studies, a universal and comprehensive assessment of factors affecting sensor calibration remains elusive, leading to potential discrepancies in data quality across different networks. To address these challenges, this study deployed eight sensor-based monitors equipped with electrochemical sensors for NO2, NO, CO, and O3 measurement in strategically chosen locations within Hong Kong, Macau, and Shanghai, covering a wide range of climatic conditions: Hong Kong's subtropical climate, Macau's similar yet distinct urban environment, and Shanghai's more variable climate. This strategic deployment ensured that the sensors' performance and calibration processes were tested across diverse atmospheric conditions. Each monitor employed a patented dynamic baseline tracking method for the gas sensors, which isolates the concentration signals from temperature and humidity effects, enhancing the sensors' accuracy and reliability. The tests, which involved evaluating the validation performance by analyzing randomly selected calibration sample subsets ranging from 1 to 15 days, indicated that the length of the calibration period, pollutant concentration range, and time averaging period are pivotal for sensor calibration quality. We determined that a 5–7 days calibration period minimizes calibration coefficient errors, and a wider concentration range improves the validation R2 values for all sensors, suggesting the necessity of setting specific concentration range thresholds. Moreover, a time averaging period of at least 5 minutes for data with 1-minute resolution was recommended to enable optimal calibration in field operation. This study emphasizes the need for a comprehensive calibration assessment and the importance of considering environmental variability in sensor calibration condition. These findings offer methodological guidance for the calibration of other sensor types, providing a reference for future research in the field of sensor calibration.
- 15 August 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-22
Open AccessImpact and Optimization of Calibration Conditions for Air Quality Sensors in the Long-term Field Monitoring
The rapid expansion of low-cost sensor networks for air quality monitoring necessitates rigorous calibration to ensure data accuracy. Despite numerous published field calibration studies, a universal and comprehensive assessment of factors affecting sensor calibration remains elusive, leading to potential discrepancies in data quality across different networks. To address these challenges, this study deployed eight sensor-based monitors equipped with electrochemical sensors for NO2, NO, CO, and O3 measurement in strategically chosen locations within Hong Kong, Macau, and Shanghai, covering a wide range of climatic conditions: Hong Kong's subtropical climate, Macau's similar yet distinct urban environment, and Shanghai's more variable climate. This strategic deployment ensured that the sensors' performance and calibration processes were tested across diverse atmospheric conditions. Each monitor employed a patented dynamic baseline tracking method for the gas sensors, which isolates the concentration signals from temperature and humidity effects, enhancing the sensors' accuracy and reliability. The tests, which involved evaluating the validation performance by analyzing randomly selected calibration sample subsets ranging from 1 to 15 days, indicated that the length of the calibration period, pollutant concentration range, and time averaging period are pivotal for sensor calibration quality. We determined that a 5–7 days calibration period minimizes calibration coefficient errors, and a wider concentration range improves the validation R2 values for all sensors, suggesting the necessity of setting specific concentration range thresholds. Moreover, a time averaging period of at least 5 minutes for data with 1-minute resolution was recommended to enable optimal calibration in field operation. This study emphasizes the need for a comprehensive calibration assessment and the importance of considering environmental variability in sensor calibration condition. These findings offer methodological guidance for the calibration of other sensor types, providing a reference for future research in the field of sensor calibration.
- Open Access
- 15 August 2024
- Published by Copernicus GmbH
Supplementary material to "Impact and Optimization of Calibration Conditions for Air Quality Sensors in the Long-term Field Monitoring"
- 15 August 2024
- Published by Copernicus GmbH
Open AccessSupplementary material to "Impact and Optimization of Calibration Conditions for Air Quality Sensors in the Long-term Field Monitoring"
- 13 January 2023
- Published by Elsevier in Building and Environment
- Vol. 230
The application of a multi-channel sensor network to decompose the local and background sources and quantify their contributions
- 13 January 2023
- Published by Elsevier in Building and Environment
- Vol. 230
The application of a multi-channel sensor network to decompose the local and background sources and quantify their contributions
- 1 November 2020
- Published by Elsevier in Atmospheric Research
- Vol. 244
The diurnal characteristics of PM-bound ROS and its influencing factors at urban ambient and roadside environments
- 1 November 2020
- Published by Elsevier in Atmospheric Research
- Vol. 244
The diurnal characteristics of PM-bound ROS and its influencing factors at urban ambient and roadside environments
- 1 June 2020
- Published by Elsevier in Science of The Total Environment
- Vol. 723, 137994
Photo-oxidation of particle phase iron species dominates the generation of reactive oxygen species in secondary aerosol
- 1 June 2020
- Published by Elsevier in Science of The Total Environment
- Vol. 723, 137994
Photo-oxidation of particle phase iron species dominates the generation of reactive oxygen species in secondary aerosol
- Top Cited Papers
- 27 April 2020
- Published by Springer Nature in Nature
- Vol. 582 (7813) , 557-560
Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals
The ongoing COVID-19 outbreak has spread rapidly on a global scale. While the transmission of SARS-CoV-2 via human respiratory droplets and direct contact is clear, the potential for aerosol transmission is poorly understood1–3. This study investigated the aerodynamic nature of SARS-CoV-2 by measuring viral RNA in aerosols in different areas of two Wuhan hospitals during the COVID-19 outbreak in February and March 2020. The concentration of SARS-CoV-2 RNA in aerosols detected in isolation wards and ventilated patient rooms was very low, but it was elevated in the patients’ toilet areas. Levels of airborne SARS-CoV-2 RNA in the majority of public areas was undetectable except in two areas prone to crowding, possibly due to infected carriers in the crowd. We found that some medical staff areas initially had high concentrations of viral RNA with aerosol size distributions showing peaks in submicrometre and/or supermicrometre regions, but these levels were reduced to undetectable levels after implementation of rigorous sanitization procedures. Although we have not established the infectivity of the virus detected in these hospital areas, we propose that SARS-CoV-2 may have the potential to be transmitted via aerosols. Our results indicate that room ventilation, open space, sanitization of protective apparel, and proper use and disinfection of toilet areas can effectively limit the concentration of SARS-CoV-2 RNA in aerosols. Future work should explore the infectivity of aerosolized virus.
- 27 April 2020
- Published by Springer Nature in Nature
- Vol. 582 (7813) , 557-560
Top Cited PapersAerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals
The ongoing COVID-19 outbreak has spread rapidly on a global scale. While the transmission of SARS-CoV-2 via human respiratory droplets and direct contact is clear, the potential for aerosol transmission is poorly understood1–3. This study investigated the aerodynamic nature of SARS-CoV-2 by measuring viral RNA in aerosols in different areas of two Wuhan hospitals during the COVID-19 outbreak in February and March 2020. The concentration of SARS-CoV-2 RNA in aerosols detected in isolation wards and ventilated patient rooms was very low, but it was elevated in the patients’ toilet areas. Levels of airborne SARS-CoV-2 RNA in the majority of public areas was undetectable except in two areas prone to crowding, possibly due to infected carriers in the crowd. We found that some medical staff areas initially had high concentrations of viral RNA with aerosol size distributions showing peaks in submicrometre and/or supermicrometre regions, but these levels were reduced to undetectable levels after implementation of rigorous sanitization procedures. Although we have not established the infectivity of the virus detected in these hospital areas, we propose that SARS-CoV-2 may have the potential to be transmitted via aerosols. Our results indicate that room ventilation, open space, sanitization of protective apparel, and proper use and disinfection of toilet areas can effectively limit the concentration of SARS-CoV-2 RNA in aerosols. Future work should explore the infectivity of aerosolized virus.