SGSabina P. W. Guenther

Sabina P. W. Guenther

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sabina P. W. Guenther has a total of 88 co-authors. Here are the top co-authors by number of shared publications:

  • Christian Hagl

    Department of Cardiac Surgery, University Hospital Munich, Ludwig-Maximilian-University, Munich, Germany

    7 shared publications
  • Nawid Khaladj

    Department of Cardiac Surgery, University Hospital Munich, Ludwig-Maximilian-University, Marchioninistr. 15, 81377 Munich, Germany

    6 shared publications
  • Frank Born

    Department of Cardiac Surgery, University Hospital Munich, Ludwig-Maximilian-University, Munich, Germany

    5 shared publications
  • Erik Bagaev

    Department of Cardiac Surgery, University Hospital Munich, Ludwig-Maximilian-University, Munich, Germany

    4 shared publications
  • Steffen Massberg

    Medical Department I, University Hospital Munich, Ludwig-Maximilian-University, Munich, Germany

    4 shared publications
  • C. Hagl

    Herzchirurgische Klinik und Poliklinik, Klinikum der Universität München, Ludwig-Maximilians-Universität, München, Deutschland

    3 shared publications

Latest Publications

  • Six-Month Outcomes after Extracorporeal Membrane Oxygenation Therapy for Severe COVID-19-Related Pulmonary Failure

    by S. Guenther, R. Cheaban, L. Höpner, N. Weinrautner, T. Kirschning, R. Al-Khalil, F. Brünger, R. Serrano, I. Barndt, M. Wiemer, et al.

    Background: Little is known on the impact of COVID-19-associated intensive care medical therapy including extracorporeal life support/membrane oxygenation (ECMO) on the long-term well-being of survivors. The aim of this study is to comprehensively characterize recovery six months after ECMO treatment for COVID-19-associated pulmonary failure. Method: All patients requiring veno-venous or veno-arterial ECMO for COVID-19-associated respiratory and/or circulatory failure between April 2020 and September 2021 were included in this retrospective analysis. Parameters included age, gender, time of ECMO treatment, and survival at hospital discharge and 6 months post-ECMO initiation. Comprehensive follow-up covering cardiopulmonary, neurocognitive, psychological, and functional status, as well as the health-related quality of life was assessed in discharged survivors. Results: Sixty patients (median age: 60.5 [51.0–65.0] years, range: 20–72 years, 23.3% female) were treated with veno-venous or veno-arterial ECMO for severe COVID-19-related pulmonary failure with or without associated circulatory failure. 41.7% (n = 25) were successfully weaned off ECMO after 24.0 (17.5–32.5, range: 10–65) days, and 40.0% (n = 24) survived to hospital discharge. At 6 months post ECMO initiation, 20 patients were alive (33.3% of all patients, 83.3% survival conditioned on survival to discharge). Of these, 19 underwent comprehensive follow-up after 6.0 (5.0–9.0) months (133 months of cumulative follow-up time). 57.9% showed no relevant or only mild deficits, while 26.3% showed moderate, and 15.8% severe deficits. Cardiopulmonary status (mMRC level: 2.0 [1.0–2.0], 84.2% ≤ 2, NYHA level 2.0 [2.0–3.0], no patient in need of home oxygen) and level of independence (73.7% with no or mild disability and independent in daily life) were satisfactory. The rate of cognitive impairments was substantial (52.6%). In 21.1%, minimal or slight depression was observed, in 26.3% moderate depression, and 15.8% showed signs of post-traumatic stress disorder. Altogether, marked impacts on social and work life were observed. Conclusion: ECMO can serve as a salvage therapy for patients with severest COVID-19-related pulmonary failure, but the total burden of deficits six months after ECMO initiation is substantial with effects on social life and work status. The focus of our efforts thus needs to shift from solely acute survival to meaningful long-term recovery. Article published online: 28 January 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Extracorporeal life support in therapy-refractory cardiocirculatory failure: looking beyond 30 days

    by Sabina P W Guenther, Roman Hornung, Dominik Joskowiak, Polyxeni Vlachea, Katharina Feil, Martin Orban, Sven Peterss, Frank Born, Jörg Hausleiter, Steffen Massberg, et al.

    OBJECTIVES: Venoarterial extracorporeal life support (ECLS) has emerged as a potentially life-saving treatment option in therapy-refractory cardiocirculatory failure, but longer-term outcome is poorly defined. Here, we present a comprehensive follow-up analysis covering all major organ systems. METHODS: From February 2012 to December 2016, 180 patients were treated with ECLS for therapy-refractory cardiogenic shock or cardiac arrest. The 30-day survival was 43.9%, and 30-day survivors (n = 79) underwent follow-up analysis with the assessment of medium-term survival, quality of life, neuropsychological, cardiopulmonary and end-organ status. RESULTS: After a median of 1.9 (1.1–3.6) years (182.4 patient years), 45 of the 79 patients (57.0%) were alive, 35.4% had died and 7.6% were lost to follow-up. Follow-up survival estimates were 78.0% at 1, 61.2% at 3 and 55.1% at 5 years. NYHA class at follow-up was ≤II for 83.3%. The median creatinine was 1.1 (1.0–1.4) mg/dl, and the median bilirubin was 0.8 (0.5–1.0) mg/dl. No patient required dialysis. Overall, 94.4% were free from moderate or severe disability, although 11.1% needed care. Full re-integration into social life was reported by 58.3%, and 39.4% were working. Quality of life was favourable for mental components, but a subset showed deficits in physical aspects. While age was the only peri-implantation parameter significantly predicting medium-term survival, adverse events and functional status at discharge or 30 days were strong predictors. CONCLUSIONS: This study demonstrates positive medium-term outcome with high rates of independence in daily life and self-care but a subset of 10–20% suffered from sustained impairments. Our results indicate that peri-implantation parameters lack predictive power but downstream morbidity and functional status at discharge or 30 days can help identify patients at risk for poor recovery.


  • Whole blood platelet aggregation kinetics under cardiopulmonary bypass: A pilot study

    by Tobias Petzold, Erik Bagaev, Helen Herzog, Frank Born, Dominik Hoechter, Sebastian Michel, Simon Rutkowski, Enzo Lüsebrink, Manuela Thienel, Steffen Massberg, et al.

    Assessing the platelets’ functional status during surgery on cardiopulmonary bypass is challenging. This study used multiple electrode impedance aggregometry (Multiplate®) to create a timeline of platelet aggregation changes as induced by cardiopulmonary bypass in antiplatelet-naive patients undergoing elective surgery for mitral valve regurgitation. We performed six consecutive measurements (T1: pre-operatively, T2: after heparinization, T3: 3 min after establishment of cardiopulmonary bypass, T4: immediately after administration of cardioplegia, T5: 5 min after administration of cardioplegia, and T6: 45 min after administration of cardioplegia). Platelet aggregation was determined after stimulation with 3.2-μg/mL collagen, 6.4-μM adenosine diphosphate, and 32-μM thrombin receptor activating peptide. Five patients were included (age: 64 ± 10 years, one female). We observed a decrease in hematocrit levels by −17.1% ± 3.7% (T1 vs T6) with a drop after establishment of cardiopulmonary bypass (T2 vs T3) and slightly decreasing platelet counts by −6.2% ± 7.7% (T1 vs T6). Immediately after establishment of cardiopulmonary bypass (T2 vs T3), we observed reduced platelet aggregation responses for stimulation with adenosine diphosphate (−19.7% ± 12.8%) and thrombin receptor activating peptide (−19.3% ± 6.3%). Interestingly, we found augmented platelet aggregation for all stimuli 45 min after administration of cardioplegia (T5 vs T6) with the strongest increase for collagen (+83.4% ± 42.8%; adenosine diphosphate: +39.0% ± 37.2%; thrombin receptor activating peptide: +34.5% ± 18.5%). Thus, after an initial drop due to hemodilution upon establishment of cardiopulmonary bypass, platelet reactivity increased over time which was not outweighed by decreasing platelet counts due to mechanical platelet destruction and absorption. These findings have implications for rational transfusion, peri-operative antiplatelet therapy, and for the management of patients on other extracorporeal support, such as extracorporeal life support or extracorporeal membrane oxygenation.


  • Open Access

    Generation of microbubbles in extracorporeal life support and assessment of new elimination strategies

    by Frank Born, Fabian König, Jinchi Chen, Sabina Günther, Christian Hagl, Nikolaus Thierfelder

    Occurrence of microbubbles (MB) is a major problem during venoarterial extracorporeal life support (ECLS) with partially severe clinical complications. The aim of this study was to establish an in vitro ECLS setup for the generation and detection of MB. Furthermore, we assessed different MB elimination strategies. Patient and ECLS circuit were simulated using reservoirs, a centrifugal pump, a membrane oxygenator, and an occluder (modified roller pump). The system was primed with a glycerin solution of 44%. Three different revolution speeds (2500, 3000, and 3400 rpm) were applied. For MB generation, the inflow line of the pump was either statically or dynamically (15 rpm) occluded. A bubble counter was used for MB detection. The effectiveness of the oxygenator and dynamic bubble traps (DBTs) was evaluated in regard to MB elimination capacities. MB generation was highly dependent on negative pressure at the inflow line. Increasing revolution speeds and restriction of the inflow led to increased MB activity. The significant difference between inflow and outflow MB volume identified the centrifugal pump as a main source. We could show that the oxygenator’s ability to withhold larger MB is limited. The application of one or multiple DBTs leads to a significant reduction in MB count and overall gas volume. The application of DBT can significantly reduce the overall gas volume, especially at high flow rates. Moreover, large MB can effectively be broken down for faster absorption. In general, the incidence of MBs is significantly dependent on pump speed and restriction of the inflow. The centrifugal pump was identified as a major source of MB generation.


  • Prolonged veno-arterial extracorporeal life support for cardiac failure

    by Sabina Pw Guenther, Yasuhiro Shudo, William Hiesinger, Dipanjan Banerjee

    Objectives: In intractable cardiogenic shock, extracorporeal life support frequently is the last treatment option. Outcomes of prolonged veno-arterial extracorporeal life support for cardiac failure are poorly defined. Methods: We retrospectively analyzed 10 patients (4 females, age = 36 ± 16 years) who underwent prolonged extracorporeal life support (≥7 days) from December 2015 to March 2017 for cardiogenic shock. The primary endpoint was survival to hospital discharge. Results: Etiologies included ischemic cardiomyopathy with non ST-segment elevation myocardial infarction (n = 1), dilated (n = 3), hypertrophic (n = 1), postpartum cardiomyopathy (n = 1), and others (n = 4). Heart failure was left or biventricular in 80.0% (left ventricular ejection fraction = 15.6 ± 5.5%). Among the 10 patients, 80.0% underwent femoral and 20.0% central cannulation, 40.0% required changes in the cannulation strategy, and 80.0% underwent left ventricular venting. No technical malfunctions occurred, but 50.0% required circuit exchanges for thrombus formation. 80.0% suffered from infections. 60.0% could be decannulated after 717 ± 830 (168–2301) h of support, and survival to hospital discharge was 40.0%. Longest follow-up available is 160 ± 175 (12–409) days after discharge, with 30.0% alive and in satisfying functional condition. Conclusion: Prolonged veno-arterial extracorporeal life support for cardiac failure is feasible with low technical complication rates. Survival rates are acceptable, yet inferior to short-term support. We observed a shift from initial shock-related complications to infections during prolonged support. Since recovery and thus weaning is rather unlikely after a prolonged need for extracorporeal life support, this form of support should be limited to centers offering the full spectrum of interdisciplinary cardiac care including ventricular assist device implantation and transplantation.


  • Patienten unter Reanimation: Kandidaten für „Extracorporeal Life Support“?

    by S. P. W. Günther, F. Born, S. Buchholz, V. von Dossow, R. Schramm, S. Brunner, S. Massberg, A. M. Pichlmaier, C. Hagl


  • Effects of the Cardio First AngelTM on chest compression performance

    by S.P.W. Guenther, M. Schirren, A.L. Boulesteix, H. Busen, T. Poettinger, A.M. Pichlmaier, N. Khaladj, C. Hagl

    BACKGROUND: Survival rates of out-of-hospital cardiac arrest remain poor. Bystander cardiopulmonary resuscitation (CPR) is crucial for survival and feedback devices could improve its quality. OBJECTIVE: We investigated the quality of chest compression when using the Cardio First Angel[ ] (CFA) feedback device compared to standard basic life support (BLS). The analysis focused on laymen. METHODS: Laymen without ([ ] 43) and with ([ ] 96) explanation of the device, medical students ([ ] 128) and medical staff ([ ] 27) performed 60 seconds of standard versus assisted chest compression using the CFA on a resuscitation manikin. Compression frequency, depth and position were analyzed according to current guidelines. RESULTS: Laymen showed significantly better success rates regarding correct compression depth when using the CFA (23.3% vs. 55.8%, [ ] 0.004 and 25.0% vs. 52.1%, [ ] 0.001, laymen without and with explanation of the device, respectively). Medical students likewise improved (22.7% vs. 42.2%, [ ] 0.004). Hand positioning was 100% correct in all groups with the device. Improvement in frequency yielded by the CFA was more pronounced for probands with fears of contact ([ ] 0.02). The benefit of using the device did not differ significantly in laymen with or without explanation. CONCLUSIONS: Chest compression as performed by laymen was significantly improved with regard to compression depth when using the CFA for guidance and feedback. With the device, no cases of incorrect hand positioning occurred in any group.


  • Remote ECLS-Implantation and Transport for Retrieval of Cardiogenic Shock Patients

    by Sabina P.W. Guenther, Stefan Buchholz, Frank Born, Stefan Brunner, René Schramm, Dominik J. Hoechter, Vera von Dossow, Maximilian Pichlmaier, Christian Hagl, Nawid Khaladj


  • Potential impact of oxygenators with venous air trap on air embolism in veno-arterial Extracorporeal Life Support

    by Frank Born, Nawid Khaladj, Maximilian Pichlmaier, René Schramm, Christian Hagl, Sabina P.W. Guenther

    BACKGROUND: Air embolism is a potentially fatal but underrecognized complication in Extracorporeal Life Support (ECLS). Oxygenators containing venous air traps have been developed to minimize the risk of air embolism in daily care. OBJECTIVE: We repr


    • 1 September 2016
      • Vol. 25  (5) , 557-567

    Immediate, Early and Late Failure after Transcatheter Aortic Valve Implantation: How to Deal with the Inoperable?

    by Sabina Pw Guenther, Maximilian A Pichlmaier, Erik Bagaev, Florian Herrmann, René Schramm, Steffen Massberg, Christian Hagl, Nawid Khaladj

    Currently, the use of transcatheter aortic valve implantation (TAVI) is constantly increasing, whilst cardiosurgical back-up varies substantially. Besides immediate conversion to surgical aortic valve replacement (SAVR) for periprocedural complications, SAVR for TAV failure may be necessary within the early or late post-implant course. The etiology, incidence, risk-stratification, management and outcome for both scenarios are largely unclear. The study aim was to provide details of the authors' experience of SAVR after the failure of TAVI at a single institution. Nineteen patients (14 males, five females) underwent SAVR after TAVI at the authors' institution between June 2008 and December 2015. The patients' initial EuroSCORE II was 8.54 ± 9.81. In eight cases (42%; 50% transfemoral) an immediate conversion was necessary due to paravalvular leakage and insufficiency (n = 1), valve-malpositioning (n = 1), valve dislocation (n = 3), valve-trapping in mitral chordae (n = 1), and annular rupture (n = 2). The 50% transfemoral EuroSCORE II was 19.06 ± 8.61. In 11 patients transcatheter valve failure occurred at a mean of 18 ± 17 months after TAVI (two patients with structural valve failure and one with severe paravalvular leakage, seven with prosthetic valve endocarditis, and one patient with aortic aneurysm); the mean EuroSCORE II was 13.42 ± 13.06. For immediate conversion, the cardiopulmonary bypass (CPB) time and aortic cross-clamp time were 104 ± 40 min and 60 ± 16 min, respectively. Concomitant procedures were necessary in two patients, one patient required hypothermic circulatory arrest (HCA) and one died intraoperatively. For early and late failure, the CPB and cross-clamp times were 115 ± 32 min and 82 ± 20 min, respectively. HCA was necessary in one patient, and concomitant procedures in seven patients. The 30-day survival was 63% for immediate SAVR and 100% for early and late SAVR, even though one more patient died on postoperative day 31 after immediate SAVR. Besides, the longest follow up periods were 29 ± 15 months and 19 ± 14 months for immediate and early/late failure, respectively. In both groups, one patient died from cardiovascular-related causes, and one from non-valve-related causes. SAVR after previous TAVI will become increasingly relevant. Due to the increasing use of TAVI in medium- or lower-risk patients, adequate strategies must be established since, in comparison to multimorbid patients, not taking action in these patients is not an option. Due to potentially high-risk patients and unique technical implications, SAVR after TAVI differs from conventional (redo) AVR. Under optimal conditions, acceptable survival rates can be achieved, but effective interdisciplinary approaches are essential.