Bruno Pereira Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bruno Pereira Silva has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Kyle Stanley
Adjunct Professor, Department of Restorative Sciences, Herman Ostrow School of Dentistry of USC, University of Southern California, Los Angeles, Calif
5 shared publicationsChristian Coachman
Adjunct Professor, Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, Pa
4 shared publicationsEduardo Mahn
Research Professor and Director of the Esthetic Dentistry Program, Department of Restorative Dentistry, Universidad de los Andes, Santiago, Chile
4 shared publicationsEmilio Jiménez-Castellanos
3 shared publicationsRafael Martinez-De-Fuentes
2 shared publicationsSivan Finkel
Adjunct Clinical Instructor, Department of Cariology and Comprehensive Care, New York University College of Dentistry, New York, NY
2 shared publications
Latest Publications
- 11 June 2021
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 33 (5) , 692-701
Predictable 3D guided adhesive bonding of porcelain veneers using 3D printed trays
Objective: This clinical report describes a novel digital technique to facilitate and improve the porcelain laminate veneers adhesive bonding procedure using a customized 3D printed guide.Clinical considerations: Porcelain veneers can be stabilized in their fully seated position with a digitally design 3D printed guide before the resin cement is polymerized. The excess cement can be carefully and predictably removed without the risk of dislodgement, rotation or misfit, allowing the clinician to light cure them under controlled pressure in the correct seating position without the risk of fracturing the ceramic material.Conclusions: Fabricating a custom 3D printed guide for veneer bonding provides significant assistance to an otherwise cumbersome and daunting clinical procedure.Clinical significance: Adhesive bonding of multiple ceramic veneers is a challenging and technique sensitive procedure. The use of a custom 3D printed guide presented in this article offers a practical aid to achieve a more predictable and precise outcome.
- 11 June 2021
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 33 (5) , 692-701
Predictable 3D guided adhesive bonding of porcelain veneers using 3D printed trays
Objective: This clinical report describes a novel digital technique to facilitate and improve the porcelain laminate veneers adhesive bonding procedure using a customized 3D printed guide.Clinical considerations: Porcelain veneers can be stabilized in their fully seated position with a digitally design 3D printed guide before the resin cement is polymerized. The excess cement can be carefully and predictably removed without the risk of dislodgement, rotation or misfit, allowing the clinician to light cure them under controlled pressure in the correct seating position without the risk of fracturing the ceramic material.Conclusions: Fabricating a custom 3D printed guide for veneer bonding provides significant assistance to an otherwise cumbersome and daunting clinical procedure.Clinical significance: Adhesive bonding of multiple ceramic veneers is a challenging and technique sensitive procedure. The use of a custom 3D printed guide presented in this article offers a practical aid to achieve a more predictable and precise outcome.
- 1 May 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 123 (5) , 739-746
Comparing the use of static versus dynamic images to evaluate a smile
- 1 May 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 123 (5) , 739-746
Comparing the use of static versus dynamic images to evaluate a smile
- 7 February 2020
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 32 (2) , 150-160
Laminate veneers: Preplanning and treatment using digital guided tooth preparation
Objective: The ability to control the reduction of tooth structure in a precise and measurable way during the preparation of ceramic veneers is a clinical challenge. The objective of this article is to introduce a new digital technology that can be used to address this challenge showing its advantages and limitations. First Fit is a digitally guided tooth preparation system that can be used to control the accurate and efficient preparation of teeth. In some cases, the system can be used to prepare the teeth for previously made restorations based on planned digital reduction.Clinical considerations: The First Fit system uses 3D‐printed guides and a specially designed handpiece for guided veneer preparation using either a one‐step or a two‐step approach. In the one‐step approach, final restorations are produced prior to preparation of the teeth using reduction guides, and veneers are cemented on the same day as preparation. The two‐step approach includes a preparation phase during which the teeth are prepared using a combination of the reduction guides and free hand techniques. Cementation is then completed at a second appointment.Conclusion: The First Fit system controls and guides veneer preparation with a minimally invasive approach. In some cases, it enables the production of veneers before tooth preparation, alleviating the need for provisional restorations.Clinical significance: The guided restorative dentistry technique described here utilizes digital CAD‐CAM technology to achieve predictable and accurate results in a minimally invasive and efficient manner.
- 7 February 2020
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 32 (2) , 150-160
Laminate veneers: Preplanning and treatment using digital guided tooth preparation
Objective: The ability to control the reduction of tooth structure in a precise and measurable way during the preparation of ceramic veneers is a clinical challenge. The objective of this article is to introduce a new digital technology that can be used to address this challenge showing its advantages and limitations. First Fit is a digitally guided tooth preparation system that can be used to control the accurate and efficient preparation of teeth. In some cases, the system can be used to prepare the teeth for previously made restorations based on planned digital reduction.Clinical considerations: The First Fit system uses 3D‐printed guides and a specially designed handpiece for guided veneer preparation using either a one‐step or a two‐step approach. In the one‐step approach, final restorations are produced prior to preparation of the teeth using reduction guides, and veneers are cemented on the same day as preparation. The two‐step approach includes a preparation phase during which the teeth are prepared using a combination of the reduction guides and free hand techniques. Cementation is then completed at a second appointment.Conclusion: The First Fit system controls and guides veneer preparation with a minimally invasive approach. In some cases, it enables the production of veneers before tooth preparation, alleviating the need for provisional restorations.Clinical significance: The guided restorative dentistry technique described here utilizes digital CAD‐CAM technology to achieve predictable and accurate results in a minimally invasive and efficient manner.
- 13 September 2019
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 31 (6) , 620-626
Layperson's preference of the transverse occlusal plane in asymmetric facial model
Objective Facial asymmetries are common, especially deviated nose and chin. The clinician must consider these variables when establishing the smile, placement and angulation of the occlusal plane. The purpose of this article is to determine if nose and chin deviations affect the perception of laypeople towards different angulations of the occlusal plane cant. Materials and Method An asymmetric facial model was created from a symmetric facial model used in a previous study. Nose and chin were deviated 3 mm to the left and eight different pictures were created, each with different degrees of occlusal plane cant in both direction. Using a visual Likert scale delivered via Websurvey within the private practice setting, 120 randomly selected laypersons evaluated each image according to their own beauty preferences. Results In an asymmetric face, nose and chin deviated 3 mm to the left, a minor occlusal plane angulation of 2° can be perceptible regardless of the direction of the cant. Conclusions The occlusal plane should be as parallel to the interpupillary line as possible. If occlusal cant is present, less than 2° of angulation it is preferable, regardless of the direction of the nose and chin. Clinical Significance In the presence of an asymmetric face, the occlusal plane should be as parallel as possible to the interpupillary line. The direction of the deviation of the nose and the chin are irrelevant factors to determine the occlusal plane. An inclination of the occlusal plane can cause vertical discrepancy, which could subsequently create malocclusion. A complete dentofacial analysis can aim at assessing the angulation of the occlusal plane not only for esthetic outcomes, but for also allowing correct occlusal function.
- 13 September 2019
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 31 (6) , 620-626
Layperson's preference of the transverse occlusal plane in asymmetric facial model
Objective Facial asymmetries are common, especially deviated nose and chin. The clinician must consider these variables when establishing the smile, placement and angulation of the occlusal plane. The purpose of this article is to determine if nose and chin deviations affect the perception of laypeople towards different angulations of the occlusal plane cant. Materials and Method An asymmetric facial model was created from a symmetric facial model used in a previous study. Nose and chin were deviated 3 mm to the left and eight different pictures were created, each with different degrees of occlusal plane cant in both direction. Using a visual Likert scale delivered via Websurvey within the private practice setting, 120 randomly selected laypersons evaluated each image according to their own beauty preferences. Results In an asymmetric face, nose and chin deviated 3 mm to the left, a minor occlusal plane angulation of 2° can be perceptible regardless of the direction of the cant. Conclusions The occlusal plane should be as parallel to the interpupillary line as possible. If occlusal cant is present, less than 2° of angulation it is preferable, regardless of the direction of the nose and chin. Clinical Significance In the presence of an asymmetric face, the occlusal plane should be as parallel as possible to the interpupillary line. The direction of the deviation of the nose and the chin are irrelevant factors to determine the occlusal plane. An inclination of the occlusal plane can cause vertical discrepancy, which could subsequently create malocclusion. A complete dentofacial analysis can aim at assessing the angulation of the occlusal plane not only for esthetic outcomes, but for also allowing correct occlusal function.
- 1 March 2019
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 31 (2) , 113-117
Layperson's Esthetic Preference to the Presence or Absence of the Interdental Papillae in the Low Smile Line: A Web‐based Study
Purpose: To determine the layperson's esthetic preference to the visual display (presence) or lack thereof (absence) of the interdental papillae during minimum smiling or the low smile line patient type.Materials and Methods: Two hundred lay‐people were shown three‐paired smile images indicative of a low gingival smile line patient type in which the vermillion border of the maxillary lip covered the mid‐facial gingiva of the anterior teeth. The three images differed only with respect to [1] presence of interdental papillae, [2] absence of the interdental papilla (“black triangle”), or [3] absence of the interdental papillae (replaced with a long restorative contact area). The three images were paired in multiple groupings; group‐1 consisted of a comparison of the presence of interdental papillae vs the lack of the interdental papillae “black triangle,” group‐2 compared the long restorative contact compared to the presence of the interdental papillae and Group‐3 compared the long restorative contact replacing a missing papilla to the absence of the interdental papillae “black triangle.” The comparisons were designed to determine the subjective preference of lay individuals between these groupings.Results: Ninety‐eight percent of lay‐people demonstrated a preference to the presence of the interdental papillae in the smile (image 1) when compared to its absence (“black triangle”; image 2) with a low smile line. Seventy percent preferred the visual display of the interdental papillae, that is, pink tissues (image 1), compared to the absence of the interdental papillae replaced with a long contact area (image 3), that is, white restorative materials, when viewing a low gingival smile line. And when comparing the absence of the interdental papillae “black triangle” to a long contact area, 92% of lay‐people preferred a long contact area vs the absence of the interdental papillae with a “black triangle” with a low smile line.Conclusions: The visual display [presence] of the interdental papillae, that is, pink tissues, is notably preferred to the absence of the interdental papillae when replaced by either a “black triangle” or long contact area in the commonly known low smile line. This emphasizes the need to assess the Interdental Smile Line (ie, visual display of interdental papillae during smiling) in all patients and the importance to preserve and/or re‐establishment of the interdental papillae, that is, pink tissues, even in patients with a low smile line.
- 1 March 2019
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 31 (2) , 113-117
Layperson's Esthetic Preference to the Presence or Absence of the Interdental Papillae in the Low Smile Line: A Web‐based Study
Purpose: To determine the layperson's esthetic preference to the visual display (presence) or lack thereof (absence) of the interdental papillae during minimum smiling or the low smile line patient type.Materials and Methods: Two hundred lay‐people were shown three‐paired smile images indicative of a low gingival smile line patient type in which the vermillion border of the maxillary lip covered the mid‐facial gingiva of the anterior teeth. The three images differed only with respect to [1] presence of interdental papillae, [2] absence of the interdental papilla (“black triangle”), or [3] absence of the interdental papillae (replaced with a long restorative contact area). The three images were paired in multiple groupings; group‐1 consisted of a comparison of the presence of interdental papillae vs the lack of the interdental papillae “black triangle,” group‐2 compared the long restorative contact compared to the presence of the interdental papillae and Group‐3 compared the long restorative contact replacing a missing papilla to the absence of the interdental papillae “black triangle.” The comparisons were designed to determine the subjective preference of lay individuals between these groupings.Results: Ninety‐eight percent of lay‐people demonstrated a preference to the presence of the interdental papillae in the smile (image 1) when compared to its absence (“black triangle”; image 2) with a low smile line. Seventy percent preferred the visual display of the interdental papillae, that is, pink tissues (image 1), compared to the absence of the interdental papillae replaced with a long contact area (image 3), that is, white restorative materials, when viewing a low gingival smile line. And when comparing the absence of the interdental papillae “black triangle” to a long contact area, 92% of lay‐people preferred a long contact area vs the absence of the interdental papillae with a “black triangle” with a low smile line.Conclusions: The visual display [presence] of the interdental papillae, that is, pink tissues, is notably preferred to the absence of the interdental papillae when replaced by either a “black triangle” or long contact area in the commonly known low smile line. This emphasizes the need to assess the Interdental Smile Line (ie, visual display of interdental papillae during smiling) in all patients and the importance to preserve and/or re‐establishment of the interdental papillae, that is, pink tissues, even in patients with a low smile line.
- 1 February 2019
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 121 (2) , 189-194
The facial flow concept: An organic orofacial analysis—the vertical component
- 1 February 2019
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 121 (2) , 189-194
The facial flow concept: An organic orofacial analysis—the vertical component
- 24 November 2017
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 30 (2) , 119-125
Layperson's perception of axial midline angulation in asymmetric faces
Objective: Asymmetric facial features such as a deviated nose and chin are common and known to affect smile esthetics. When presented with these asymmetries, the clinician must consider the impact they will have on the smile design parameters—especially the placement and angulation of the dental midline, which is a common starting point for a case involving smile design. The purpose of this article is to determine if the nose and chin deviations affect the perception of dental midline angulation.Materials and Methods: An asymmetric facial model (AFM) was created from a digital symmetric facial model, used in a previous study by digitally deviating the nose and chin to the same side. Eight different pictures of this AFM were created, each with different degrees of maxillary midline angulation (both in and against the direction of the deviated nose and chin). Using a visual Likert scaled delivered via Websurvey in the private practice setting, one hundred and ninety‐six randomly selected laypersons were asked to evaluate each image according to their own notions of beauty.Results: A minor axial dental midline angulation of 3.5° can be perceived independently of the direction of the cant. All pictures where the midline was canted pointing in the opposite direction of nose and chin deviations presented lower rating mean values.Conclusions: Off‐center noses and chins can influence the perceived attractiveness of a smile with a canted dental midline. The degree and direction of a canted midline can influence the harmony between the smile and overall face, with canting in the same direction of the asymmetric features being rated as more attractive.Clinical Significance: The dental midline should be as vertically straight as possible. If a midline cant is present, however, it is more favorable to have a dental midline angulation which points in the same direction as nose and chin deviations, rather than in the opposite direction.
- 24 November 2017
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 30 (2) , 119-125
Layperson's perception of axial midline angulation in asymmetric faces
Objective: Asymmetric facial features such as a deviated nose and chin are common and known to affect smile esthetics. When presented with these asymmetries, the clinician must consider the impact they will have on the smile design parameters—especially the placement and angulation of the dental midline, which is a common starting point for a case involving smile design. The purpose of this article is to determine if the nose and chin deviations affect the perception of dental midline angulation.Materials and Methods: An asymmetric facial model (AFM) was created from a digital symmetric facial model, used in a previous study by digitally deviating the nose and chin to the same side. Eight different pictures of this AFM were created, each with different degrees of maxillary midline angulation (both in and against the direction of the deviated nose and chin). Using a visual Likert scaled delivered via Websurvey in the private practice setting, one hundred and ninety‐six randomly selected laypersons were asked to evaluate each image according to their own notions of beauty.Results: A minor axial dental midline angulation of 3.5° can be perceived independently of the direction of the cant. All pictures where the midline was canted pointing in the opposite direction of nose and chin deviations presented lower rating mean values.Conclusions: Off‐center noses and chins can influence the perceived attractiveness of a smile with a canted dental midline. The degree and direction of a canted midline can influence the harmony between the smile and overall face, with canting in the same direction of the asymmetric features being rated as more attractive.Clinical Significance: The dental midline should be as vertically straight as possible. If a midline cant is present, however, it is more favorable to have a dental midline angulation which points in the same direction as nose and chin deviations, rather than in the opposite direction.
- 11 April 2017
- Published by Editora Napoleao Ltda ME in THE INTERNATIONAL JOURNAL OF PERIODONTICS AND RESTORATIVE DENTISTRY
- Vol. 2 (2) , 378
Percepção de Assimetrias Faciais e Dentárias por Leigos
- 11 April 2017
- Published by Editora Napoleao Ltda ME in THE INTERNATIONAL JOURNAL OF PERIODONTICS AND RESTORATIVE DENTISTRY
- Vol. 2 (2) , 378
Percepção de Assimetrias Faciais e Dentárias por Leigos
- 1 April 2017
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 117 (4) , 513-516
Layperson’s preference regarding orientation of the transverse occlusal plane and commissure line from the frontal perspective
- 1 April 2017
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 117 (4) , 513-516
Layperson’s preference regarding orientation of the transverse occlusal plane and commissure line from the frontal perspective
- 1 January 2015
- Vol. 10 (4) , 588-96
Perception of maxillary dental midline shift in asymmetric faces.
The purpose of this article is to determine whether certain facial asymmetries (nose and chin) have an impact on the perception of the maxillary dental midline shift. From a digitally created symmetric facial model (SFM) constructed in a previous study, a new asymmetric facial model (AFM) was created, with nose and chin deviated to the same side. Modifications were made on the AFM for shifts in the maxillary dental midline in both directions, resulting in a total of eight different images. Through a web survey, 112 randomly selected laypersons were asked to evaluate each image according to their own personal beauty and esthetic criteria using a visual Likert scale. 1 mm of dental midline shift to the left of the AFM was not noticed; 1 mm of dental midline shift to the right of the AFM had a negative impact on perception of facial attractiveness; 2 and 3 mm of dental midline shift to left or right of the AFM had a negative impact on perception of facial attractiveness. Facial asymmetries such as nose and chin inclinations have an impact on the perception of maxillary dental midline shift. Direction of dental midline shift can be a major factor in this perception.
- 1 January 2015
- Vol. 10 (4) , 588-96
Perception of maxillary dental midline shift in asymmetric faces.
The purpose of this article is to determine whether certain facial asymmetries (nose and chin) have an impact on the perception of the maxillary dental midline shift. From a digitally created symmetric facial model (SFM) constructed in a previous study, a new asymmetric facial model (AFM) was created, with nose and chin deviated to the same side. Modifications were made on the AFM for shifts in the maxillary dental midline in both directions, resulting in a total of eight different images. Through a web survey, 112 randomly selected laypersons were asked to evaluate each image according to their own personal beauty and esthetic criteria using a visual Likert scale. 1 mm of dental midline shift to the left of the AFM was not noticed; 1 mm of dental midline shift to the right of the AFM had a negative impact on perception of facial attractiveness; 2 and 3 mm of dental midline shift to left or right of the AFM had a negative impact on perception of facial attractiveness. Facial asymmetries such as nose and chin inclinations have an impact on the perception of maxillary dental midline shift. Direction of dental midline shift can be a major factor in this perception.