Ryan J. Balla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ryan J. Balla has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Shigeru Amemiya
University of Pittsburgh 219 Parkman Avenue
10 shared publications - Kevin C. Leonard
University of Kansas
4 shared publications - Pavithra Pathirathna
Department of Chemistry and Chemical Engineering, Florida Institute of Technology, 150 W. University Blvd, Melbourne, FL 32901, USA
4 shared publications - Ran Chen
Southeast University
4 shared publications Niraja Kurapati
Department of Chemistry, University of Pittsburgh, 219 Parkman Avenue, Pittsburgh, Pennsylvania 15260, United States
3 shared publications- Amin Morteza Najarian
The Edward S. Rogers Department of Electrical and Computer Engineering, University of Toronto, Toronto, Canada
2 shared publications
Latest Publications
- Open Access
- 21 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (26) , 10765-10771
Nanoscale Quantitative Imaging of Single Nuclear Pore Complexes by Scanning Electrochemical Microscopy
The nuclear pore complex (NPC) is a proteinaceous nanopore that solely and selectively regulates the molecular transport between the cytoplasm and nucleus of a eukaryotic cell. The ∼50 nm-diameter pore of the NPC perforates the double-membrane nuclear envelope to mediate both passive and facilitated molecular transport, thereby playing paramount biological and biomedical roles. Herein, we visualize single NPCs by scanning electrochemical microscopy (SECM). The high spatial resolution is accomplished by employing ∼25 nm-diameter ion-selective nanopipets to monitor the passive transport of tetrabutylammonium at individual NPCs. SECM images are quantitatively analyzed by employing the finite element method to confirm that this work represents the highest-resolution nanoscale SECM imaging of biological samples. Significantly, we apply the powerful imaging technique to address the long-debated origin of the central plug of the NPC. Nanoscale SECM imaging demonstrates that unplugged NPCs are more permeable to the small probe ion than are plugged NPCs. This result supports the hypothesis that the central plug is not an intrinsic transporter, but is an impermeable macromolecule, e.g., a ribonucleoprotein, trapped in the nanopore. Moreover, this result also supports the transport mechanism where the NPC is divided into the central pathway for RNA export and the peripheral pathway for protein import to efficiently mediate the bidirectional traffic.
- 21 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (26) , 10765-10771
Open AccessNanoscale Quantitative Imaging of Single Nuclear Pore Complexes by Scanning Electrochemical Microscopy
The nuclear pore complex (NPC) is a proteinaceous nanopore that solely and selectively regulates the molecular transport between the cytoplasm and nucleus of a eukaryotic cell. The ∼50 nm-diameter pore of the NPC perforates the double-membrane nuclear envelope to mediate both passive and facilitated molecular transport, thereby playing paramount biological and biomedical roles. Herein, we visualize single NPCs by scanning electrochemical microscopy (SECM). The high spatial resolution is accomplished by employing ∼25 nm-diameter ion-selective nanopipets to monitor the passive transport of tetrabutylammonium at individual NPCs. SECM images are quantitatively analyzed by employing the finite element method to confirm that this work represents the highest-resolution nanoscale SECM imaging of biological samples. Significantly, we apply the powerful imaging technique to address the long-debated origin of the central plug of the NPC. Nanoscale SECM imaging demonstrates that unplugged NPCs are more permeable to the small probe ion than are plugged NPCs. This result supports the hypothesis that the central plug is not an intrinsic transporter, but is an impermeable macromolecule, e.g., a ribonucleoprotein, trapped in the nanopore. Moreover, this result also supports the transport mechanism where the NPC is divided into the central pathway for RNA export and the peripheral pathway for protein import to efficiently mediate the bidirectional traffic.
- 13 December 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (51) , 17956-17963
Nanogap-Resolved Adsorption-Coupled Electron Transfer by Scanning Electrochemical Microscopy: Implications for Electrocatalysis
Here, we demonstrate for the first time that the mechanism of adsorption-coupled electron-transfer (ACET) reactions can be identified experimentally. The electron transfer (ET) and specific adsorption of redox-active molecules are coupled in many electrode reactions with practical importance and fundamental interest. ACET reactions are often represented by a concerted mechanism. In reductive adsorption, an oxidant is simultaneously reduced and adsorbed as a reductant on the electrode surface through the ACET step. Alternatively, the non-concerted mechanism mediates outer-sphere reduction and adsorption separately when the reductant adsorption is reversible. In electrocatalysis, reversibly adsorbed reductants are ubiquitous and crucial intermediates. Moreover, electrocatalysis is complicated by the mixed mechanism based on simultaneous ACET and outer-sphere ET steps. In this work, we reveal the non-concerted mechanism for ferrocene derivatives adsorbed at highly oriented pyrolytic graphite as simple models. We enable the transient voltammetric mode of nanoscale scanning electrochemical microscopy (SECM) to kinetically control the adsorption step, which is required for the discrimination of non-concerted, concerted, and mixed mechanisms. Experimental voltammograms are compared with each mechanism by employing finite element simulation. The non-concerted mechanism is supported to indicate that the ACET step is intrinsically slower than its outer-sphere counterpart by at least four orders of magnitude. This finding implies that an ACET step is facilitated thermodynamically but may not be necessarily accelerated or catalyzed by the adsorption of the reductant. SECM-based transient voltammetry will become a powerful tool to resolve and understand electrocatalytic ACET reactions at the elementary level.
- 13 December 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (51) , 17956-17963
Nanogap-Resolved Adsorption-Coupled Electron Transfer by Scanning Electrochemical Microscopy: Implications for Electrocatalysis
Here, we demonstrate for the first time that the mechanism of adsorption-coupled electron-transfer (ACET) reactions can be identified experimentally. The electron transfer (ET) and specific adsorption of redox-active molecules are coupled in many electrode reactions with practical importance and fundamental interest. ACET reactions are often represented by a concerted mechanism. In reductive adsorption, an oxidant is simultaneously reduced and adsorbed as a reductant on the electrode surface through the ACET step. Alternatively, the non-concerted mechanism mediates outer-sphere reduction and adsorption separately when the reductant adsorption is reversible. In electrocatalysis, reversibly adsorbed reductants are ubiquitous and crucial intermediates. Moreover, electrocatalysis is complicated by the mixed mechanism based on simultaneous ACET and outer-sphere ET steps. In this work, we reveal the non-concerted mechanism for ferrocene derivatives adsorbed at highly oriented pyrolytic graphite as simple models. We enable the transient voltammetric mode of nanoscale scanning electrochemical microscopy (SECM) to kinetically control the adsorption step, which is required for the discrimination of non-concerted, concerted, and mixed mechanisms. Experimental voltammograms are compared with each mechanism by employing finite element simulation. The non-concerted mechanism is supported to indicate that the ACET step is intrinsically slower than its outer-sphere counterpart by at least four orders of magnitude. This finding implies that an ACET step is facilitated thermodynamically but may not be necessarily accelerated or catalyzed by the adsorption of the reductant. SECM-based transient voltammetry will become a powerful tool to resolve and understand electrocatalytic ACET reactions at the elementary level.
- Open Access
- 15 June 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (25) , 8906-8914
Simultaneous Intelligent Imaging of Nanoscale Reactivity and Topography by Scanning Electrochemical Microscopy
Scanning electrochemical microscopy (SECM) enables reactivity and topography imaging of single nanostructures in the electrolyte solution. The in situ reactivity and topography, however, are convoluted in the real-time image, thus requiring another imaging method for subsequent deconvolution. Herein, we develop an intelligent mode of nanoscale SECM to simultaneously obtain separate reactivity and topography images of non-flat substrates with reactive and inert regions. Specifically, an ∼0.5 μm-diameter Pt tip approaches a substrate with an ∼0.15 μm-height active Au band adjacent to an ∼0.4 μm-wide slope of the inactive glass surface followed by a flat inactive glass region. The amperometric tip current versus tip–substrate distance is measured to observe feedback effects including redox-mediated electron tunneling from the substrate. The intelligent SECM software automatically terminates the tip approach depending on the local reactivity and topography of the substrate under the tip. The resultant short tip–substrate distances allow for non-contact and high-resolution imaging in contrast to other imaging modes based on approach curves. The numerical post-analysis of each approach curve locates the substrate under the tip for quantitative topography imaging and determines the tip current at a constant distance for topography-independent reactivity imaging. The nanoscale grooves are revealed by intelligent topography SECM imaging as compared to scanning electron microscopy and atomic force microscopy without reactivity information and as unnoticed by constant-height SECM imaging owing to the convolution of topography with reactivity. Additionally, intelligent reactivity imaging traces abrupt changes in the constant-distance tip current across the Au/glass boundary, which prevents constant-current SECM imaging.
- 15 June 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (25) , 8906-8914
Open AccessSimultaneous Intelligent Imaging of Nanoscale Reactivity and Topography by Scanning Electrochemical Microscopy
Scanning electrochemical microscopy (SECM) enables reactivity and topography imaging of single nanostructures in the electrolyte solution. The in situ reactivity and topography, however, are convoluted in the real-time image, thus requiring another imaging method for subsequent deconvolution. Herein, we develop an intelligent mode of nanoscale SECM to simultaneously obtain separate reactivity and topography images of non-flat substrates with reactive and inert regions. Specifically, an ∼0.5 μm-diameter Pt tip approaches a substrate with an ∼0.15 μm-height active Au band adjacent to an ∼0.4 μm-wide slope of the inactive glass surface followed by a flat inactive glass region. The amperometric tip current versus tip–substrate distance is measured to observe feedback effects including redox-mediated electron tunneling from the substrate. The intelligent SECM software automatically terminates the tip approach depending on the local reactivity and topography of the substrate under the tip. The resultant short tip–substrate distances allow for non-contact and high-resolution imaging in contrast to other imaging modes based on approach curves. The numerical post-analysis of each approach curve locates the substrate under the tip for quantitative topography imaging and determines the tip current at a constant distance for topography-independent reactivity imaging. The nanoscale grooves are revealed by intelligent topography SECM imaging as compared to scanning electron microscopy and atomic force microscopy without reactivity information and as unnoticed by constant-height SECM imaging owing to the convolution of topography with reactivity. Additionally, intelligent reactivity imaging traces abrupt changes in the constant-distance tip current across the Au/glass boundary, which prevents constant-current SECM imaging.
- 16 July 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (15) , 10227-10235
Nanoscale Intelligent Imaging Based on Real-Time Analysis of Approach Curve by Scanning Electrochemical Microscopy
Scanning electrochemical microscopy (SECM) enables high-resolution imaging by examining the amperometric response of an ultramicroelectrode tip near a substrate. Spatial resolution, however, is compromised for nonflat substrates, where distances from a tip far exceed the tip size to avoid artifacts caused by the tip–substrate contact. Herein, we propose a new imaging mode of SECM based on real-time analysis of the approach curve to actively control nanoscale tip–substrate distances without contact. The power of this software-based method is demonstrated by imaging an insulating substrate with step edges using standard instrumentation without combination of another method for distance measurement, e.g., atomic force microscopy. An ∼500 nm diameter Pt tip approaches down to ∼50 nm from upper and lower terraces of a 500 nm height step edge, which are located by real-time theoretical fitting of an experimental approach curve to ensure the lack of electrochemical reactivity. The tip approach to the step edge can be terminated at <20 nm prior to the tip–substrate contact as soon as the theory deviates from the tip current, which is analyzed numerically afterward to locate the inert edge. The advantageous local adjustment of tip height and tip current at the final point of tip approach distinguishes the proposed imaging mode from other modes based on standard instrumentation. In addition, the glass sheath of the Pt tip is thinned to ∼150 nm to rarely contact the step edge, which is unavoidable and instantaneously detected as an abrupt change in the slope of approach curve to prevent damage of the fragile nanotip.
- 16 July 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (15) , 10227-10235
Nanoscale Intelligent Imaging Based on Real-Time Analysis of Approach Curve by Scanning Electrochemical Microscopy
Scanning electrochemical microscopy (SECM) enables high-resolution imaging by examining the amperometric response of an ultramicroelectrode tip near a substrate. Spatial resolution, however, is compromised for nonflat substrates, where distances from a tip far exceed the tip size to avoid artifacts caused by the tip–substrate contact. Herein, we propose a new imaging mode of SECM based on real-time analysis of the approach curve to actively control nanoscale tip–substrate distances without contact. The power of this software-based method is demonstrated by imaging an insulating substrate with step edges using standard instrumentation without combination of another method for distance measurement, e.g., atomic force microscopy. An ∼500 nm diameter Pt tip approaches down to ∼50 nm from upper and lower terraces of a 500 nm height step edge, which are located by real-time theoretical fitting of an experimental approach curve to ensure the lack of electrochemical reactivity. The tip approach to the step edge can be terminated at <20 nm prior to the tip–substrate contact as soon as the theory deviates from the tip current, which is analyzed numerically afterward to locate the inert edge. The advantageous local adjustment of tip height and tip current at the final point of tip approach distinguishes the proposed imaging mode from other modes based on standard instrumentation. In addition, the glass sheath of the Pt tip is thinned to ∼150 nm to rarely contact the step edge, which is unavoidable and instantaneously detected as an abrupt change in the slope of approach curve to prevent damage of the fragile nanotip.
- Open Access
- 8 July 2019
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 10 (34) , 7929-7936
Nanoscale electrostatic gating of molecular transport through nuclear pore complexes as probed by scanning electrochemical microscopy
The nuclear pore complex (NPC) is a large protein nanopore that solely mediates molecular transport between the nucleus and cytoplasm of a eukaryotic cell. There is a long-standing consensus that selective transport barriers of the NPC are exclusively based on hydrophobic repeats of phenylalanine and glycine (FG) of nucleoporins. Herein, we reveal experimentally that charged residues of amino acids intermingled between FG repeats can modulate molecular transport through the NPC electrostatically and in a pathway-dependent manner. Specifically, we investigate the NPC of the Xenopus oocyte nucleus to find that excess positive charges of FG-rich nucleoporins slow down passive transport of a polycationic peptide, protamine, without affecting that of a polyanionic pentasaccharide, Arixtra, and small monovalent ions. Protamine transport is slower with a lower concentration of electrolytes in the transport media, where the Debye length becomes comparable to the size of water-filled spaces among the gel-like network of FG repeats. Slow protamine transport is not affected by the binding of a lectin, wheat germ agglutinin, to the peripheral route of the NPC, which is already blocked electrostatically by adjacent nucleoporins that have more cationic residues than anionic residues and even FG dipeptides. The permeability of NPCs to the probe ions is measured by scanning electrochemical microscopy using ion-selective tips based on liquid/liquid microinterfaces and is analysed by effective medium theory to determine the sizes of peripheral and central routes with distinct protamine permeability. Significantly, nanoscale electrostatic gating at the NPC can be relevant not only chemically and biologically, but also biomedically for efficient nuclear import of genetically therapeutic substances.
- 8 July 2019
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 10 (34) , 7929-7936
Open AccessNanoscale electrostatic gating of molecular transport through nuclear pore complexes as probed by scanning electrochemical microscopy
The nuclear pore complex (NPC) is a large protein nanopore that solely mediates molecular transport between the nucleus and cytoplasm of a eukaryotic cell. There is a long-standing consensus that selective transport barriers of the NPC are exclusively based on hydrophobic repeats of phenylalanine and glycine (FG) of nucleoporins. Herein, we reveal experimentally that charged residues of amino acids intermingled between FG repeats can modulate molecular transport through the NPC electrostatically and in a pathway-dependent manner. Specifically, we investigate the NPC of the Xenopus oocyte nucleus to find that excess positive charges of FG-rich nucleoporins slow down passive transport of a polycationic peptide, protamine, without affecting that of a polyanionic pentasaccharide, Arixtra, and small monovalent ions. Protamine transport is slower with a lower concentration of electrolytes in the transport media, where the Debye length becomes comparable to the size of water-filled spaces among the gel-like network of FG repeats. Slow protamine transport is not affected by the binding of a lectin, wheat germ agglutinin, to the peripheral route of the NPC, which is already blocked electrostatically by adjacent nucleoporins that have more cationic residues than anionic residues and even FG dipeptides. The permeability of NPCs to the probe ions is measured by scanning electrochemical microscopy using ion-selective tips based on liquid/liquid microinterfaces and is analysed by effective medium theory to determine the sizes of peripheral and central routes with distinct protamine permeability. Significantly, nanoscale electrostatic gating at the NPC can be relevant not only chemically and biologically, but also biomedically for efficient nuclear import of genetically therapeutic substances.
- 25 March 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (8) , 5446-5454
Probing High Permeability of Nuclear Pore Complexes by Scanning Electrochemical Microscopy: Ca2+ Effects on Transport Barriers
The nuclear pore complex (NPC) solely mediates molecular transport between the nucleus and cytoplasm of a eukaryotic cell to play important biological and biomedical roles. However, it is not well-understood chemically how this biological nanopore selectively and efficiently transports various substances, including small molecules, proteins, and RNAs by using transport barriers that are rich in highly disordered repeats of hydrophobic phenylalanine and glycine intermingled with charged amino acids. Herein, we employ scanning electrochemical microscopy to image and measure the high permeability of NPCs to small redox molecules. The effective medium theory demonstrates that the measured permeability is controlled by diffusional translocation of probe molecules through water-filled nanopores without steric or electrostatic hindrance from hydrophobic or charged regions of transport barriers, respectively. However, the permeability of NPCs is reduced by a low millimolar concentration of Ca2+, which can interact with anionic regions of transport barriers to alter their spatial distributions within the nanopore. We employ atomic force microscopy to confirm that transport barriers of NPCs are dominantly recessed (∼80%) or entangled (∼20%) at the high Ca2+ level in contrast to authentic populations of entangled (∼50%), recessed (∼25%), and “plugged” (∼25%) conformations at a physiological Ca2+ level of submicromolar. We propose a model for synchronized Ca2+ effects on the conformation and permeability of NPCs, where transport barriers are viscosified to lower permeability. Significantly, this result supports a hypothesis that the functional structure of transport barriers is maintained not only by their hydrophobic regions, but also by charged regions.
- 25 March 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (8) , 5446-5454
Probing High Permeability of Nuclear Pore Complexes by Scanning Electrochemical Microscopy: Ca2+ Effects on Transport Barriers
The nuclear pore complex (NPC) solely mediates molecular transport between the nucleus and cytoplasm of a eukaryotic cell to play important biological and biomedical roles. However, it is not well-understood chemically how this biological nanopore selectively and efficiently transports various substances, including small molecules, proteins, and RNAs by using transport barriers that are rich in highly disordered repeats of hydrophobic phenylalanine and glycine intermingled with charged amino acids. Herein, we employ scanning electrochemical microscopy to image and measure the high permeability of NPCs to small redox molecules. The effective medium theory demonstrates that the measured permeability is controlled by diffusional translocation of probe molecules through water-filled nanopores without steric or electrostatic hindrance from hydrophobic or charged regions of transport barriers, respectively. However, the permeability of NPCs is reduced by a low millimolar concentration of Ca2+, which can interact with anionic regions of transport barriers to alter their spatial distributions within the nanopore. We employ atomic force microscopy to confirm that transport barriers of NPCs are dominantly recessed (∼80%) or entangled (∼20%) at the high Ca2+ level in contrast to authentic populations of entangled (∼50%), recessed (∼25%), and “plugged” (∼25%) conformations at a physiological Ca2+ level of submicromolar. We propose a model for synchronized Ca2+ effects on the conformation and permeability of NPCs, where transport barriers are viscosified to lower permeability. Significantly, this result supports a hypothesis that the functional structure of transport barriers is maintained not only by their hydrophobic regions, but also by charged regions.
- 25 September 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (20) , 11746-11750
Nanogap-Based Electrochemical Measurements at Double-Carbon-Fiber Ultramicroelectrodes
Electrochemical measurements with unprecedentedly high sensitivity, selectivity, and kinetic resolution have been enabled by a pair of electrodes separated by a nanometer-wide gap. The fabrication of nanogap electrodes, however, requires extensive nanolithography or nanoscale electrode positioning, thereby preventing the full exploration of this powerful method in electrode design and application. Herein, we report the simple fabrication of double-carbon-fiber ultramicroelectrodes (UMEs) with nanometer-wide gaps not only to facilitate nanogap-based electrochemical measurements but also to gain high time resolution, signal-to-background ratio, and kinetic selectivity for dopamine against ascorbic acid. Specifically, ∼7 μm-diameter carbon fibers are inserted into a double-bore glass capillary, heat-pulled, and milled by focused ion-beam technology to yield ∼50 μm-long double-cylinder UMEs. The redox cycling of the Ru(NH3)63+/2+ couple across a nanogap between voltammetric generator and amperometric collector electrodes reaches quasi-steady states at fast scan rates of 100 V/s as demonstrated experimentally and even 1000 V/s as predicted theoretically. The transient background of the amperometric collector response is suppressed ∼100 times in comparison with that of the voltammetric generator response. Nanogap voltammograms based on the collector response against the cycled generator potential are quantitatively analyzed without background subtraction to reproducibly yield nanogap widths of ∼0.18 μm and a standard electron-transfer rate constant of 0.9 cm/s. Moreover, nanogap-mediated redox cycling can be initiated by dopamine oxidation at the generator electrode to largely improve the dopamine selectivity of the collector response against ascorbic acid, which is also oxidized at the generator electrode to immediately and irreversibly produce a redox-inactive species.
- 25 September 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (20) , 11746-11750
Nanogap-Based Electrochemical Measurements at Double-Carbon-Fiber Ultramicroelectrodes
Electrochemical measurements with unprecedentedly high sensitivity, selectivity, and kinetic resolution have been enabled by a pair of electrodes separated by a nanometer-wide gap. The fabrication of nanogap electrodes, however, requires extensive nanolithography or nanoscale electrode positioning, thereby preventing the full exploration of this powerful method in electrode design and application. Herein, we report the simple fabrication of double-carbon-fiber ultramicroelectrodes (UMEs) with nanometer-wide gaps not only to facilitate nanogap-based electrochemical measurements but also to gain high time resolution, signal-to-background ratio, and kinetic selectivity for dopamine against ascorbic acid. Specifically, ∼7 μm-diameter carbon fibers are inserted into a double-bore glass capillary, heat-pulled, and milled by focused ion-beam technology to yield ∼50 μm-long double-cylinder UMEs. The redox cycling of the Ru(NH3)63+/2+ couple across a nanogap between voltammetric generator and amperometric collector electrodes reaches quasi-steady states at fast scan rates of 100 V/s as demonstrated experimentally and even 1000 V/s as predicted theoretically. The transient background of the amperometric collector response is suppressed ∼100 times in comparison with that of the voltammetric generator response. Nanogap voltammograms based on the collector response against the cycled generator potential are quantitatively analyzed without background subtraction to reproducibly yield nanogap widths of ∼0.18 μm and a standard electron-transfer rate constant of 0.9 cm/s. Moreover, nanogap-mediated redox cycling can be initiated by dopamine oxidation at the generator electrode to largely improve the dopamine selectivity of the collector response against ascorbic acid, which is also oxidized at the generator electrode to immediately and irreversibly produce a redox-inactive species.
- 17 August 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (18) , 11115-11123
Self-Inhibitory Electron Transfer of the Co(III)/Co(II)-Complex Redox Couple at Pristine Carbon Electrode
Applications of conducting carbon materials for highly efficient electrochemical energy devices require a greater fundamental understanding of heterogeneous electron-transfer (ET) mechanisms. This task, however, is highly challenging experimentally, because an adsorbing carbon surface may easily conceal its intrinsic reactivity through adventitious contamination. Herein, we employ nanoscale scanning electrochemical microscopy (SECM) and cyclic voltammetry to gain new insights into the interplay between heterogeneous ET and adsorption of a Co(III)/Co(II)-complex redox couple at the contamination-free surface of electron-beam-deposited carbon (eC). Specifically, we investigate the redox couple of tris(1,10-phenanthroline)cobalt(II), Co(phen)32+, as a promising mediator for dye-sensitized solar cells and redox flow batteries. A pristine eC surface overlaid with KCl is prepared in vacuum, protected from contamination in air, and exposed to an ultrapure aqueous solution of Co(phen)32+ by the dissolution of the protective KCl layer. We employ SECM-based nanogap voltammetry to quantitatively demonstrate that Co(phen)32+ is adsorbed on the pristine eC surface to electrostatically self-inhibit outer-sphere ET of nonadsorbed Co(phen)33+ and Co(phen)32+. Strong electrostatic repulsion among Co(phen)32+ adsorbates is also demonstrated by SECM-based nanogap voltammetry and cyclic voltammetry. Quantitatively, self-inhibitory ET is characterized by a linear decrease in the standard rate constant of Co(phen)32+ oxidation with a higher surface concentration of Co(phen)32+ at the formal potential. This unique relationship is consistent not with the Frumkin model of double layer effects, but with the Amatore model of partially blocked electrodes as extended for self-inhibitory ET. Significantly, the complicated coupling of electron transfer and surface adsorption is resolved by combining nanoscale and macroscale voltammetric methods.
- 17 August 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (18) , 11115-11123
Self-Inhibitory Electron Transfer of the Co(III)/Co(II)-Complex Redox Couple at Pristine Carbon Electrode
Applications of conducting carbon materials for highly efficient electrochemical energy devices require a greater fundamental understanding of heterogeneous electron-transfer (ET) mechanisms. This task, however, is highly challenging experimentally, because an adsorbing carbon surface may easily conceal its intrinsic reactivity through adventitious contamination. Herein, we employ nanoscale scanning electrochemical microscopy (SECM) and cyclic voltammetry to gain new insights into the interplay between heterogeneous ET and adsorption of a Co(III)/Co(II)-complex redox couple at the contamination-free surface of electron-beam-deposited carbon (eC). Specifically, we investigate the redox couple of tris(1,10-phenanthroline)cobalt(II), Co(phen)32+, as a promising mediator for dye-sensitized solar cells and redox flow batteries. A pristine eC surface overlaid with KCl is prepared in vacuum, protected from contamination in air, and exposed to an ultrapure aqueous solution of Co(phen)32+ by the dissolution of the protective KCl layer. We employ SECM-based nanogap voltammetry to quantitatively demonstrate that Co(phen)32+ is adsorbed on the pristine eC surface to electrostatically self-inhibit outer-sphere ET of nonadsorbed Co(phen)33+ and Co(phen)32+. Strong electrostatic repulsion among Co(phen)32+ adsorbates is also demonstrated by SECM-based nanogap voltammetry and cyclic voltammetry. Quantitatively, self-inhibitory ET is characterized by a linear decrease in the standard rate constant of Co(phen)32+ oxidation with a higher surface concentration of Co(phen)32+ at the formal potential. This unique relationship is consistent not with the Frumkin model of double layer effects, but with the Amatore model of partially blocked electrodes as extended for self-inhibitory ET. Significantly, the complicated coupling of electron transfer and surface adsorption is resolved by combining nanoscale and macroscale voltammetric methods.
- 29 November 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (24) , 13532-13540
Ultraflat, Pristine, and Robust Carbon Electrode for Fast Electron-Transfer Kinetics
Electron-beam (e-beam) deposition of carbon on a gold substrate yields a very flat (0.43 nm of root-mean-square roughness), amorphous carbon film consisting of a mixture of sp2- and sp3-hybridized carbon with sufficient conductivity to avoid ohmic potential error. E-beam carbon (eC) has attractive properties for conventional electrochemistry, including low background current and sufficient transparency for optical spectroscopy. A layer of KCl deposited by e-beam to the eC surface without breaking vacuum protects the surface from the environment after fabrication until dissolved by an ultrapure electrolyte solution. Nanogap voltammetry using scanning electrochemical microscopy (SECM) permits measurement of heterogeneous standard electron-transfer rate constants (k°) in a clean environment without exposure of the electrode surface to ambient air. The ultraflat eC surface permitted nanogap voltammetry with very thin electrode-to-substrate gaps, thus increasing the diffusion limit for k° measurement to >14 cm/s for a gap of 44 nm. Ferrocene trimethylammonium as the redox mediator exhibited a diffusion-limited k° for the previously KCl-protected eC surface, while k° was 1.45 cm/s for unprotected eC. The k° for Ru(NH3)63+/2+ increased from 1.7 cm/s for unprotected eC to above the measurable limit of 6.9 cm/s for a KCl-protected eC electrode.
- 29 November 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (24) , 13532-13540
Ultraflat, Pristine, and Robust Carbon Electrode for Fast Electron-Transfer Kinetics
Electron-beam (e-beam) deposition of carbon on a gold substrate yields a very flat (0.43 nm of root-mean-square roughness), amorphous carbon film consisting of a mixture of sp2- and sp3-hybridized carbon with sufficient conductivity to avoid ohmic potential error. E-beam carbon (eC) has attractive properties for conventional electrochemistry, including low background current and sufficient transparency for optical spectroscopy. A layer of KCl deposited by e-beam to the eC surface without breaking vacuum protects the surface from the environment after fabrication until dissolved by an ultrapure electrolyte solution. Nanogap voltammetry using scanning electrochemical microscopy (SECM) permits measurement of heterogeneous standard electron-transfer rate constants (k°) in a clean environment without exposure of the electrode surface to ambient air. The ultraflat eC surface permitted nanogap voltammetry with very thin electrode-to-substrate gaps, thus increasing the diffusion limit for k° measurement to >14 cm/s for a gap of 44 nm. Ferrocene trimethylammonium as the redox mediator exhibited a diffusion-limited k° for the previously KCl-protected eC surface, while k° was 1.45 cm/s for unprotected eC. The k° for Ru(NH3)63+/2+ increased from 1.7 cm/s for unprotected eC to above the measurable limit of 6.9 cm/s for a KCl-protected eC electrode.
- 18 August 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (18) , 9946-9952
Characterization of Nanopipet-Supported ITIES Tips for Scanning Electrochemical Microscopy of Single Solid-State Nanopores
Nanoscale scanning electrochemical microscopy (SECM) is a powerful scanning probe technique that enables high-resolution imaging of chemical processes at single nanometer-sized objects. However, it has been a challenging task to quantitatively understand nanoscale SECM images, which requires accurate characterization of the size and geometry of nanoelectrode tips. Herein, we address this challenge through transmission electron microscopy (TEM) of quartz nanopipets for SECM imaging of single solid-state nanopores by using nanopipet-supported interfaces between two immiscible electrolyte solutions (ITIES) as tips. We take advantage of the high resolution of TEM to demonstrate that laser-pulled quartz nanopipets reproducibly yield not only an extremely small tip diameter of ∼30 nm, but also a substantial tip roughness of ∼5 nm. The size and roughness of a nanopipet can be reliably determined by optimizing the intensity of the electron beam not to melt or deform the quartz nanotip without a metal coating. Electrochemically, the nanoscale ITIES supported by a rough nanotip gives higher amperometric responses to tetrabutylammonium than expected for a 30 nm diameter disc tip. The finite element simulation of sphere-cap ITIES tips accounts for the high current responses and also reveals that the SECM images of 100 nm diameter Si3N4 nanopores are enlarged along the direction of the tip scan. Nevertheless, spatial resolution is not significantly compromised by a sphere-cap tip, which can be scanned in closer proximity to the substrate. This finding augments the utility of a protruded tip, which can be fabricated and miniaturized more readily to facilitate nanoscale SECM imaging.
- 18 August 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (18) , 9946-9952
Characterization of Nanopipet-Supported ITIES Tips for Scanning Electrochemical Microscopy of Single Solid-State Nanopores
Nanoscale scanning electrochemical microscopy (SECM) is a powerful scanning probe technique that enables high-resolution imaging of chemical processes at single nanometer-sized objects. However, it has been a challenging task to quantitatively understand nanoscale SECM images, which requires accurate characterization of the size and geometry of nanoelectrode tips. Herein, we address this challenge through transmission electron microscopy (TEM) of quartz nanopipets for SECM imaging of single solid-state nanopores by using nanopipet-supported interfaces between two immiscible electrolyte solutions (ITIES) as tips. We take advantage of the high resolution of TEM to demonstrate that laser-pulled quartz nanopipets reproducibly yield not only an extremely small tip diameter of ∼30 nm, but also a substantial tip roughness of ∼5 nm. The size and roughness of a nanopipet can be reliably determined by optimizing the intensity of the electron beam not to melt or deform the quartz nanotip without a metal coating. Electrochemically, the nanoscale ITIES supported by a rough nanotip gives higher amperometric responses to tetrabutylammonium than expected for a 30 nm diameter disc tip. The finite element simulation of sphere-cap ITIES tips accounts for the high current responses and also reveals that the SECM images of 100 nm diameter Si3N4 nanopores are enlarged along the direction of the tip scan. Nevertheless, spatial resolution is not significantly compromised by a sphere-cap tip, which can be scanned in closer proximity to the substrate. This finding augments the utility of a protruded tip, which can be fabricated and miniaturized more readily to facilitate nanoscale SECM imaging.