Mario Montes-Usategui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mario Montes-Usategui has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Estela Martín-Badosa
Univ. de Barcelona (Spain)
20 shared publications - Ignacio Juvells
Universitat de Barcelona (UB), Facultat de Física, Departament de Física Aplicada, Martí i Franquès 1, 08028 Barcelona, Spain
12 shared publications Arnau Farré
Institut de Nanociència i Nanotecnologia (IN2UB), Martí i Franquès 1, 08028 Barcelona, Spain
11 shared publications- Artur Carnicer
Universitat de Barcelona
10 shared publications Santiago Vallmitjana
The authors are with the Departament de Física Aplicada i Òptica, Universitat de Barcelona, Avinguda Diagonal 647, Barcelona E08028, Spain
8 shared publicationsFerran Marsà
Institut de Nanociència i Nanotecnologia (IN2UB), Martí i Franquès 1, 08028 Barcelona, Spain
7 shared publications
Latest Publications
- Open Access
- 16 September 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 204
Super-pupil beam engineering for enhanced confinement of azimuthally polarized depletion beams
- 16 September 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 204
Open AccessSuper-pupil beam engineering for enhanced confinement of azimuthally polarized depletion beams
- Open Access
- 1 January 2020
- Published by Universidad Francisco de Paula Santander in Respuestas
- Vol. 25 (1) , 53-59
Analysis of the Transverse Force in the Rayleigh and Mie Approximations for a Capture Beam TEM00 and TEM*01
Optical tweezers use a highly-focused laser beam to capture and manipulate micro- and nanometric objects. These have been demonstrated to be a promising devices for state-of-the-art research in several fields, such as microbiology and biophysics. The prediction of the optical forces that are present in this phenomenon is a current problem in continuous evolution. Additionally, the recent use of vortex beams with exotic properties as the orbital angular momentum, with advantages as the rotational manipulation of the captured microparticles and reduction of the optical damage in biological samples (Opticution), makes the problem even more complex. Mathematical expressions in the Rayleigh and Mie regimes for the radiation force on a dielectric sphere captured by TEM00 and TEM*01 mode beams are presented. Theoretical results are then compared with experimental measurements obtained with a direct force measurement device based on light-momentum detection.
- 1 January 2020
- Published by Universidad Francisco de Paula Santander in Respuestas
- Vol. 25 (1) , 53-59
Open AccessAnalysis of the Transverse Force in the Rayleigh and Mie Approximations for a Capture Beam TEM00 and TEM*01
Optical tweezers use a highly-focused laser beam to capture and manipulate micro- and nanometric objects. These have been demonstrated to be a promising devices for state-of-the-art research in several fields, such as microbiology and biophysics. The prediction of the optical forces that are present in this phenomenon is a current problem in continuous evolution. Additionally, the recent use of vortex beams with exotic properties as the orbital angular momentum, with advantages as the rotational manipulation of the captured microparticles and reduction of the optical damage in biological samples (Opticution), makes the problem even more complex. Mathematical expressions in the Rayleigh and Mie regimes for the radiation force on a dielectric sphere captured by TEM00 and TEM*01 mode beams are presented. Theoretical results are then compared with experimental measurements obtained with a direct force measurement device based on light-momentum detection.
- Open Access
- 21 February 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep42960-10
Extending calibration-free force measurements to optically-trapped rod-shaped samples
Optical trapping has become an optimal choice for biological research at the microscale due to its non-invasive performance and accessibility for quantitative studies, especially on the forces involved in biological processes. However, reliable force measurements depend on the calibration of the optical traps, which is different for each experiment and hence requires high control of the local variables, especially of the trapped object geometry. Many biological samples have an elongated, rod-like shape, such as chromosomes, intracellular organelles (e.g., peroxisomes), membrane tubules, certain microalgae, and a wide variety of bacteria and parasites. This type of samples often requires several optical traps to stabilize and orient them in the correct spatial direction, making it more difficult to determine the total force applied. Here, we manipulate glass microcylinders with holographic optical tweezers and show the accurate measurement of drag forces by calibration-free direct detection of beam momentum. The agreement between our results and slender-body hydrodynamic theoretical calculations indicates potential for this force-sensing method in studying protracted, rod-shaped specimens.
- 21 February 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep42960-10
Open AccessExtending calibration-free force measurements to optically-trapped rod-shaped samples
Optical trapping has become an optimal choice for biological research at the microscale due to its non-invasive performance and accessibility for quantitative studies, especially on the forces involved in biological processes. However, reliable force measurements depend on the calibration of the optical traps, which is different for each experiment and hence requires high control of the local variables, especially of the trapped object geometry. Many biological samples have an elongated, rod-like shape, such as chromosomes, intracellular organelles (e.g., peroxisomes), membrane tubules, certain microalgae, and a wide variety of bacteria and parasites. This type of samples often requires several optical traps to stabilize and orient them in the correct spatial direction, making it more difficult to determine the total force applied. Here, we manipulate glass microcylinders with holographic optical tweezers and show the accurate measurement of drag forces by calibration-free direct detection of beam momentum. The agreement between our results and slender-body hydrodynamic theoretical calculations indicates potential for this force-sensing method in studying protracted, rod-shaped specimens.
- 17 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Optical tweezers for force measurements and rheological studies on biological samples
Light allows the observation of the microscopic world but also, by means of optical tweezers, the non-invasive manipulation of micro-objects and the measurement of the forces exerted on them. However, measuring forces inside living cells is still a challenge due the characteristics of the trapped organelles (non-spherical, unknown size and index of refraction) and the cell cytoplasm surrounding them (heterogeneous and dynamic, non-purely viscous). Here, we show how two very recent methods overcome these limitations: on the one hand, forces can be measured in such environment by the direct detection of changes in the light momentum; on the other hand, an active-passive calibration technique provides both the stiffness of the optical trap as well as the local viscoelastic properties of the cell cytoplasm.
- 17 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Optical tweezers for force measurements and rheological studies on biological samples
Light allows the observation of the microscopic world but also, by means of optical tweezers, the non-invasive manipulation of micro-objects and the measurement of the forces exerted on them. However, measuring forces inside living cells is still a challenge due the characteristics of the trapped organelles (non-spherical, unknown size and index of refraction) and the cell cytoplasm surrounding them (heterogeneous and dynamic, non-purely viscous). Here, we show how two very recent methods overcome these limitations: on the one hand, forces can be measured in such environment by the direct detection of changes in the light momentum; on the other hand, an active-passive calibration technique provides both the stiffness of the optical trap as well as the local viscoelastic properties of the cell cytoplasm.
- 15 November 2016
- Published by Springer Nature
- Vol. 1486, 41-76
Beyond the Hookean Spring Model: Direct Measurement of Optical Forces Through Light Momentum Changes
The ability to measure forces in the range of 0.1–100 pN is a key feature of optical tweezers used for biophysical and cell biological studies. Analysis of the interactions between biomolecules and the forces that biomolecular motors generate at the single-molecule level has provided valuable insights in the molecular mechanisms that govern key cellular functions such as gene expression and the long-distance transport of organelles. Methods for determining the minute forces that biomolecular motors generate exhibit notable constraints that limit their application for studies other than the well-controlled in vitro experiments (although recent advances have been made that permit more quantitative optical tweezers studies insight living cells). One constraint comes from the linear approximation of the distance vs. force relationship used to extract the force from the position of the bead in the trap. This commonly employed “indirect” approach, although usually sufficiently precise, restricts the use of optical tweezers to a limited range of displacements (typically up to ±150 nm for small beads). Measurements based on the detection of the light-momentum changes, on the other hand, offer a “direct” and precise way to determine forces even when the generated displacements reach the escape point, thus covering the complete force range developed by the trap. In this chapter, we detail the requirements for the design of a force-sensor instrument based on light-momentum changes using a high-numerical-aperture objective lens and provide insights into its construction. We further discuss the calibration of the system and the main steps for its routine operation.
- 15 November 2016
- Published by Springer Nature
- Vol. 1486, 41-76
Beyond the Hookean Spring Model: Direct Measurement of Optical Forces Through Light Momentum Changes
The ability to measure forces in the range of 0.1–100 pN is a key feature of optical tweezers used for biophysical and cell biological studies. Analysis of the interactions between biomolecules and the forces that biomolecular motors generate at the single-molecule level has provided valuable insights in the molecular mechanisms that govern key cellular functions such as gene expression and the long-distance transport of organelles. Methods for determining the minute forces that biomolecular motors generate exhibit notable constraints that limit their application for studies other than the well-controlled in vitro experiments (although recent advances have been made that permit more quantitative optical tweezers studies insight living cells). One constraint comes from the linear approximation of the distance vs. force relationship used to extract the force from the position of the bead in the trap. This commonly employed “indirect” approach, although usually sufficiently precise, restricts the use of optical tweezers to a limited range of displacements (typically up to ±150 nm for small beads). Measurements based on the detection of the light-momentum changes, on the other hand, offer a “direct” and precise way to determine forces even when the generated displacements reach the escape point, thus covering the complete force range developed by the trap. In this chapter, we detail the requirements for the design of a force-sensor instrument based on light-momentum changes using a high-numerical-aperture objective lens and provide insights into its construction. We further discuss the calibration of the system and the main steps for its routine operation.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 44, 1-3
Force measurement in the manipulation of complex samples with holographic optical tweezers
Holographic optical tweezers are a powerful tool for the dynamic manipulation of micron-sized objects with light. The measurement of the forces exerted by the traps by direct detection of beam momentum is not restricted to spherical samples, viscous environments or the assumption of a harmonic trapping potential. Here, we demonstrate that forces on complex beams, such as a multiple trap system or a cogwheel beam, or samples such as cylinders, can be measured with this method. It also allows quantitative studies inside the cell, where molecular motors exert characteristic forces within a heterogeneous and viscoelastic medium such as the cytoplasm.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 44, 1-3
Force measurement in the manipulation of complex samples with holographic optical tweezers
Holographic optical tweezers are a powerful tool for the dynamic manipulation of micron-sized objects with light. The measurement of the forces exerted by the traps by direct detection of beam momentum is not restricted to spherical samples, viscous environments or the assumption of a harmonic trapping potential. Here, we demonstrate that forces on complex beams, such as a multiple trap system or a cogwheel beam, or samples such as cylinders, can be measured with this method. It also allows quantitative studies inside the cell, where molecular motors exert characteristic forces within a heterogeneous and viscoelastic medium such as the cytoplasm.
- 1 January 2015
- Published by Optica Publishing Group
- p. OtT1D.1
Force measurements in complex samples with optical tweezers
Here, we show the potential of the detection of changes in the light momentum as a precise method to determine forces in complex samples: in non-homogeneous media, with non-Gaussian beams and on non-spherical particles.
- 1 January 2015
- Published by Optica Publishing Group
- p. OtT1D.1
Force measurements in complex samples with optical tweezers
Here, we show the potential of the detection of changes in the light momentum as a precise method to determine forces in complex samples: in non-homogeneous media, with non-Gaussian beams and on non-spherical particles.
- 22 September 2014
- Published by Sociedad Espanola de Optica in Optica Pura y Aplicada
- Vol. 47 (3) , 239-248
The measurement of light momentum shines the path towards the cell
- 22 September 2014
- Published by Sociedad Espanola de Optica in Optica Pura y Aplicada
- Vol. 47 (3) , 239-248
The measurement of light momentum shines the path towards the cell
- 16 September 2014
- Published by SPIE-Intl Soc Optical Eng
- p. 91640U-91640U-9
Force measurements with optical tweezers inside living cells
- 16 September 2014
- Published by SPIE-Intl Soc Optical Eng
- p. 91640U-91640U-9
Force measurements with optical tweezers inside living cells
- 16 September 2014
- Published by SPIE-Intl Soc Optical Eng
- p. 91640A-91640A-6
Momentum measurements with holographic optical tweezers for exploring force detection capabilities on irregular samples
- 16 September 2014
- Published by SPIE-Intl Soc Optical Eng
- p. 91640A-91640A-6
Momentum measurements with holographic optical tweezers for exploring force detection capabilities on irregular samples