Georgios P. Kondylis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Georgios P. Kondylis has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Anestis G. Anastasiadis
7 shared publicationsGeorgios A. Vokas
5 shared publicationsStavros A. Konstantinopoulos
5 shared publicationsApostolos Polyzakis
3 shared publications- Panagiotis Papageorgas
Department of Electrical and Electronics Engineering, University of West Attica, 12244 Athens, Greece
3 shared publications Konstantinos Tsatsakis
2 shared publications
Latest Publications
- 21 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 2829-2836
Simplified Formulae Method for Estimating Wind Turbine Generators Ground Resistance
This paper aims to extract simple formulae for estimating the ground resistance values of wind turbines (WT) installed at terrains which can be modeled by two-layer soil structure. Several grounding system configurations, applied in construction practice, were used as case studies. Various combinations of soil resistivity values for the upper and the lower layer of a two-layer soil model, as well as for the depth of the upper layer, are carefully selected in order to cover a wide range of nonuniformities in the ground. Thereafter, ground resistance value is estimated from software simulations, for each combination among the examined two-layer models and the predefined grounding electrodes geometry. Furthermore, regression analysis techniques are applied to create a model describing the behavior of the ground resistance and to fit the equations using data from the aforementioned simulations. The whole procedure has been algorithmized so that the process is easily replicable. Finally, the model is verified and its accuracy is tested through applicable validation data sets.
- 21 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 2829-2836
Simplified Formulae Method for Estimating Wind Turbine Generators Ground Resistance
This paper aims to extract simple formulae for estimating the ground resistance values of wind turbines (WT) installed at terrains which can be modeled by two-layer soil structure. Several grounding system configurations, applied in construction practice, were used as case studies. Various combinations of soil resistivity values for the upper and the lower layer of a two-layer soil model, as well as for the depth of the upper layer, are carefully selected in order to cover a wide range of nonuniformities in the ground. Thereafter, ground resistance value is estimated from software simulations, for each combination among the examined two-layer models and the predefined grounding electrodes geometry. Furthermore, regression analysis techniques are applied to create a model describing the behavior of the ground resistance and to fit the equations using data from the aforementioned simulations. The whole procedure has been algorithmized so that the process is easily replicable. Finally, the model is verified and its accuracy is tested through applicable validation data sets.
- 8 January 2018
- Published by Emerald Publishing in Management of Environmental Quality: An International Journal
- Vol. 29 (1) , 76-88
Carbon tax, system marginal price and environmental policies on Smart Microgrid operation
Purpose: The purpose of this paper is to optimally operate a Smart Microgrid which is interconnected to the main grid so as to minimize expenditures associated with CO2 emissions. Microgrids could come into play to aid the network through CO2 emission reduction while increasing their efficiency through local generation. For this purpose, a Smart Microgrid incorporating Distributed Energy Resources (DER), especially Renewable Energy Sources (RES), is operated optimally while keeping the CO2 emissions in check in order to minimize the financial burden from emissions stemming from the carbon tax. Since the network is assumed to be interconnected with the main grid, there is a consideration of the expected emissions associated with the imported energy. Design/methodology/approach: An economic/environmental dispatch problem is mathematically formulated using an objective function and the constraints that it is subject to. The methodology is applied on a typical 17-bus test distribution network, representing a Hellenic LV network. Various carbon tax rates and their impact on the system marginal price are examined, in terms of their effect on distributed generation (DG) and as a second step, the effect of imposing lower carbon tax rates for micro-sources with the goal of benefitting from their more eco-friendly generation capabilities. In order to assess that benefit, hourly grid emissions coefficients are derived based on actual grid data. Findings: The CO2 tax refund policy towards the DG owners can lead to optimal coverage of consumers, optimal financial result both for the DG owners and the operator and greater DG integration within the smart grid. Originality/value: Greater DG integration within the smart grid by using a CO2 tax refund policy.
- 8 January 2018
- Published by Emerald Publishing in Management of Environmental Quality: An International Journal
- Vol. 29 (1) , 76-88
Carbon tax, system marginal price and environmental policies on Smart Microgrid operation
Purpose: The purpose of this paper is to optimally operate a Smart Microgrid which is interconnected to the main grid so as to minimize expenditures associated with CO2 emissions. Microgrids could come into play to aid the network through CO2 emission reduction while increasing their efficiency through local generation. For this purpose, a Smart Microgrid incorporating Distributed Energy Resources (DER), especially Renewable Energy Sources (RES), is operated optimally while keeping the CO2 emissions in check in order to minimize the financial burden from emissions stemming from the carbon tax. Since the network is assumed to be interconnected with the main grid, there is a consideration of the expected emissions associated with the imported energy. Design/methodology/approach: An economic/environmental dispatch problem is mathematically formulated using an objective function and the constraints that it is subject to. The methodology is applied on a typical 17-bus test distribution network, representing a Hellenic LV network. Various carbon tax rates and their impact on the system marginal price are examined, in terms of their effect on distributed generation (DG) and as a second step, the effect of imposing lower carbon tax rates for micro-sources with the goal of benefitting from their more eco-friendly generation capabilities. In order to assess that benefit, hourly grid emissions coefficients are derived based on actual grid data. Findings: The CO2 tax refund policy towards the DG owners can lead to optimal coverage of consumers, optimal financial result both for the DG owners and the operator and greater DG integration within the smart grid. Originality/value: Greater DG integration within the smart grid by using a CO2 tax refund policy.
- 1 January 2018
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 43 (1) , 490-499
Optimal management of hydrogen storage in stochastic smart microgrid operation
- 1 January 2018
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 43 (1) , 490-499
Optimal management of hydrogen storage in stochastic smart microgrid operation
- Open Access
- 1 July 2017
- Published by Elsevier in Energy Procedia
- Vol. 119, 417-425
Economic benefits from the coordinated control of Distributed Energy Resources and different Charging Technologies of Electric Vehicles in a Smart Microgrid
- 1 July 2017
- Published by Elsevier in Energy Procedia
- Vol. 119, 417-425
Open AccessEconomic benefits from the coordinated control of Distributed Energy Resources and different Charging Technologies of Electric Vehicles in a Smart Microgrid
- Open Access
- 1 July 2017
- Published by Elsevier in Energy Procedia
- Vol. 119, 407-416
Wind Generation and Electric Vehicles coordination in Microgrids for Peak Shaving purposes
- 1 July 2017
- Published by Elsevier in Energy Procedia
- Vol. 119, 407-416
Open AccessWind Generation and Electric Vehicles coordination in Microgrids for Peak Shaving purposes
- 1 March 2017
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 42 (12) , 8242-8254
Electric vehicle charging in stochastic smart microgrid operation with fuel cell and RES units
- 1 March 2017
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 42 (12) , 8242-8254
Electric vehicle charging in stochastic smart microgrid operation with fuel cell and RES units
- 1 February 2017
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 42 (5) , 3479-3486
Effect of fuel cell units in economic and environmental dispatch of a Microgrid with penetration of photovoltaic and micro turbine units
- 1 February 2017
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 42 (5) , 3479-3486
Effect of fuel cell units in economic and environmental dispatch of a Microgrid with penetration of photovoltaic and micro turbine units
- 1 January 2017
- Published by AIP Publishing
Application of voltage oriented control technique in a fully renewable, wind powered, autonomous system with storage capabilities
The main purpose of this paper is to examine the technological feasibility of a small autonomous network, with electricity storage capability, which is completely electrified by wind energy. The excess energy produced, with respect to the load requirements, is sent to the batteries for storage. When the energy produced by the wind generator is not sufficient, load’s energy requirement is covered by the battery system, ensuring, however, that voltage, frequency and other system characteristics are within the proper boundaries. For the purpose of this study, a Voltage Oriented Control system has been developed in order to monitor the autonomous operation and perform the energy management of the network. This system manages the power flows between the load and the storage system by properly controlling the Pulse Width Modulation pulses in the converter, thus ensuring power flows are adequate and frequency remains under control. The experimental results clearly indicate that a stand-alone wind energy system based on battery energy storage system is feasible and reliable. This paves the way for fully renewable and zero emission energy schemes.
- 1 January 2017
- Published by AIP Publishing
Application of voltage oriented control technique in a fully renewable, wind powered, autonomous system with storage capabilities
The main purpose of this paper is to examine the technological feasibility of a small autonomous network, with electricity storage capability, which is completely electrified by wind energy. The excess energy produced, with respect to the load requirements, is sent to the batteries for storage. When the energy produced by the wind generator is not sufficient, load’s energy requirement is covered by the battery system, ensuring, however, that voltage, frequency and other system characteristics are within the proper boundaries. For the purpose of this study, a Voltage Oriented Control system has been developed in order to monitor the autonomous operation and perform the energy management of the network. This system manages the power flows between the load and the storage system by properly controlling the Pulse Width Modulation pulses in the converter, thus ensuring power flows are adequate and frequency remains under control. The experimental results clearly indicate that a stand-alone wind energy system based on battery energy storage system is feasible and reliable. This paves the way for fully renewable and zero emission energy schemes.
- 11 April 2016
- Published by Emerald Publishing in Management of Environmental Quality: An International Journal
- Vol. 27 (3) , 246-258
Hydrothermal coordination in power systems with large-scale integration of renewable energy sources
Purpose: – The purpose of this paper is to examine the feasibility of an ideal power network that combines many different renewable energy technologies such as wind power, concentrated solar power (CSP) and hydroelectric power. This paper emphasizes in finding the benefits arising from hydrothermal coordination compared to the non-regulated integration of the hydroelectric units, as well as the benefits from the integration of wind power and CSP. Design/methodology/approach: – Artificial Neural Networks were used to estimate wind power output. As for the CSP system, a three-tier architecture which includes a solar field, a transmission-storage system and a production unit was used. Each one of those separate sections is analyzed and the process is modeled. As for the hydroelectric plant, the knowledge of the water’s flow rated has helped estimating the power output, taking into account the technical restrictions and losses during transmission. Also, the economic dispatch problem was solved by using artificial intelligence methods. Findings: – Hydrothermal coordination leads to greater thermal participation reduction and cost reduction than a non-regulated integration of the hydrothermal unit. The latter is independent from the degree of integration of the other renewable sources (wind power, CSP). Originality/value: – Hydrothermal coordination in a power system which includes thermal units and CSP for cost and emissions reduction.
- 11 April 2016
- Published by Emerald Publishing in Management of Environmental Quality: An International Journal
- Vol. 27 (3) , 246-258
Hydrothermal coordination in power systems with large-scale integration of renewable energy sources
Purpose: – The purpose of this paper is to examine the feasibility of an ideal power network that combines many different renewable energy technologies such as wind power, concentrated solar power (CSP) and hydroelectric power. This paper emphasizes in finding the benefits arising from hydrothermal coordination compared to the non-regulated integration of the hydroelectric units, as well as the benefits from the integration of wind power and CSP. Design/methodology/approach: – Artificial Neural Networks were used to estimate wind power output. As for the CSP system, a three-tier architecture which includes a solar field, a transmission-storage system and a production unit was used. Each one of those separate sections is analyzed and the process is modeled. As for the hydroelectric plant, the knowledge of the water’s flow rated has helped estimating the power output, taking into account the technical restrictions and losses during transmission. Also, the economic dispatch problem was solved by using artificial intelligence methods. Findings: – Hydrothermal coordination leads to greater thermal participation reduction and cost reduction than a non-regulated integration of the hydrothermal unit. The latter is independent from the degree of integration of the other renewable sources (wind power, CSP). Originality/value: – Hydrothermal coordination in a power system which includes thermal units and CSP for cost and emissions reduction.
- Open Access
- 1 January 2014
- Published by Elsevier in Energy Procedia
- Vol. 50, 824-831
Effects of Carbon Taxation, Distributed Generation and Electricity Storage Technologies on a Microgrid
- 1 January 2014
- Published by Elsevier in Energy Procedia
- Vol. 50, 824-831
Open AccessEffects of Carbon Taxation, Distributed Generation and Electricity Storage Technologies on a Microgrid