Teemu Kääriäinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Teemu Kääriäinen has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Timo Dönsberg
VTT Technical Research Centre of Finland, Tekniikantie 1, 02150, Espoo, Finland
4 shared publications - Albert Manninen
Optics Laboratory, Department of Physics, Tampere University of Technology, P.O. Box 692, FI-33101 Tampere, Finland
3 shared publications - Aigar Vaigu
VTT Technical Research Centre of Finland Ltd, Vuorimiehentie 3, 02150 Espoo, Finland
1 shared publication - Andreas Knobloch
Beak Consultants GmbH
1 shared publication - Craig A. Richmond
VTT Technical Research Centre of Finland Ltd., Vuorimiehentie 3, 02150 Espoo, Finland
1 shared publication - Francisco Senna Vieira
VTT Technical Research Centre of Finland Ltd
1 shared publication
Latest Publications
- 8 August 2025
- Published by Geological Society of London in Geological Society, London, Special Publications
- Vol. 559 (1) , 195-214
Innovative lithium prediction based on artificial neural networks and hyperspectral data: traditional v. active hyperspectral scanning systems at the Zinnwald deposit
To advance Europe's self-reliance in sustainably sourcing lithium, innovative exploration technologies that enhance the efficiency of both exploration and extraction are urgently required. Lithium's role in rechargeable batteries necessitates advanced methods to support domestic resource development and meet rising demand. This study evaluates artificial neural networks (ANN) combined with hyperspectral data for lithium prediction, comparing the HySpex Mjolnir S-620 sensor and the Technical Research Centre of Finland Oy's (VTT) novel active hyperspectral scanner (AHS). The AHS employs a broadband short-wave infrared supercontinuum light source, avoiding dependency on external illumination and overcoming limitations of traditional systems in underground settings. At Germany's Zinnwald/Cínovec greisen deposit, lithium prediction was achieved via ANN trained on portable X-ray fluorescence (pXRF)-derived rubidium data, a proxy for lithium in zinnwaldite-rich mineralization. Hyperspectral processing extracted diagnostic absorption features (e.g. band ratios, minimum wavelength mapping) and classified lithium-bearing minerals. The ANN model produced a high-resolution lithium concentration map, demonstrating the AHS's ability to enhance mine-face characterization for both detailed exploration and operational workflows, such as grade control. Integrating hyperspectral sensing and machine learning supports Europe's sustainable objectives by enabling more precise and efficient resource extraction, offering scalable solutions for modern mining. The AHS–ANN framework also holds potential for agriculture, environmental monitoring and defence, where rapid material characterization is paramount.
- 8 August 2025
- Published by Geological Society of London in Geological Society, London, Special Publications
- Vol. 559 (1) , 195-214
Innovative lithium prediction based on artificial neural networks and hyperspectral data: traditional v. active hyperspectral scanning systems at the Zinnwald deposit
To advance Europe's self-reliance in sustainably sourcing lithium, innovative exploration technologies that enhance the efficiency of both exploration and extraction are urgently required. Lithium's role in rechargeable batteries necessitates advanced methods to support domestic resource development and meet rising demand. This study evaluates artificial neural networks (ANN) combined with hyperspectral data for lithium prediction, comparing the HySpex Mjolnir S-620 sensor and the Technical Research Centre of Finland Oy's (VTT) novel active hyperspectral scanner (AHS). The AHS employs a broadband short-wave infrared supercontinuum light source, avoiding dependency on external illumination and overcoming limitations of traditional systems in underground settings. At Germany's Zinnwald/Cínovec greisen deposit, lithium prediction was achieved via ANN trained on portable X-ray fluorescence (pXRF)-derived rubidium data, a proxy for lithium in zinnwaldite-rich mineralization. Hyperspectral processing extracted diagnostic absorption features (e.g. band ratios, minimum wavelength mapping) and classified lithium-bearing minerals. The ANN model produced a high-resolution lithium concentration map, demonstrating the AHS's ability to enhance mine-face characterization for both detailed exploration and operational workflows, such as grade control. Integrating hyperspectral sensing and machine learning supports Europe's sustainable objectives by enabling more precise and efficient resource extraction, offering scalable solutions for modern mining. The AHS–ANN framework also holds potential for agriculture, environmental monitoring and defence, where rapid material characterization is paramount.
- Open Access
- 7 February 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (4) , 6342-6349
3D camera based on laser light absorption by atmospheric oxygen at 761 nm
A 3D camera based on laser light absorption of atmospheric oxygen at 761 nm is presented. The camera uses a current-tunable single frequency distributed feedback laser for active illumination and a silicon-based image sensor as a receiver. This simple combination enables capturing 3D images with a compact and mass producible set-up. The 3D camera is validated in indoor environments. Distance accuracy of better than 4 cm is demonstrated between 4 m and 10 m distances. Future potential and improvements are discussed.
- 7 February 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (4) , 6342-6349
Open Access3D camera based on laser light absorption by atmospheric oxygen at 761 nm
A 3D camera based on laser light absorption of atmospheric oxygen at 761 nm is presented. The camera uses a current-tunable single frequency distributed feedback laser for active illumination and a silicon-based image sensor as a receiver. This simple combination enables capturing 3D images with a compact and mass producible set-up. The 3D camera is validated in indoor environments. Distance accuracy of better than 4 cm is demonstrated between 4 m and 10 m distances. Future potential and improvements are discussed.
- 1 January 2023
- Published by Optica Publishing Group
- Vol. 67, JTh1A.4
Active 3D camera based on laser absorption of molecular oxygen
We present a novel method for 3D imaging, based on laser light absorption by atmospheric oxygen. The camera uses a current tunable distributed feedback laser for illumination and a silicon-based CMOS camera for imaging.
- 1 January 2023
- Published by Optica Publishing Group
- Vol. 67, JTh1A.4
Active 3D camera based on laser absorption of molecular oxygen
We present a novel method for 3D imaging, based on laser light absorption by atmospheric oxygen. The camera uses a current tunable distributed feedback laser for illumination and a silicon-based CMOS camera for imaging.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 46, JTu2A.2
Compact active hyperspectral imager based on tuneable short wave infrared supercontinuum laser
Compact active hyperspectral imager is presented. The imager is based on tuneable broadband near-infrared supercontinuum laser and monochromatic camera. The compact imager is capable of rapid hyperspectral imaging for ranges over 30 m.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 46, JTu2A.2
Compact active hyperspectral imager based on tuneable short wave infrared supercontinuum laser
Compact active hyperspectral imager is presented. The imager is based on tuneable broadband near-infrared supercontinuum laser and monochromatic camera. The compact imager is capable of rapid hyperspectral imaging for ranges over 30 m.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 46, SF3F.5
Active hyperspectral imager based on a supercontinuum laser and a MEMS Fabry–Pérot interferometer
We present the design and characterization of tunable SWIR supercontinuum laser based active hyperspectral imager. A MEMS Fabry–Perot interferometer is used for non-dispersive wavelength selection, enabling the use of monochromatic camera for hyperspectral imaging.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 46, SF3F.5
Active hyperspectral imager based on a supercontinuum laser and a MEMS Fabry–Pérot interferometer
We present the design and characterization of tunable SWIR supercontinuum laser based active hyperspectral imager. A MEMS Fabry–Perot interferometer is used for non-dispersive wavelength selection, enabling the use of monochromatic camera for hyperspectral imaging.
- 3 November 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (22) , 5533-5536
Active hyperspectral imager using a tunable supercontinuum light source based on a MEMS Fabry–Perot interferometer
We have developed an active hyperspectral imager based on a tunable near-infrared supercontinuum light source. Non-dispersive wavelength selection of the supercontinuum laser source is achieved with a microelectromechanical Fabry–Perot interferometer. The tunable light source enables the use of any monochromatic imaging sensor with a suitable spectral sensitivity for hyperspectral imaging. The imager is characterized and demonstrated in the laboratory for remote detection of ice.
- 3 November 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (22) , 5533-5536
Active hyperspectral imager using a tunable supercontinuum light source based on a MEMS Fabry–Perot interferometer
We have developed an active hyperspectral imager based on a tunable near-infrared supercontinuum light source. Non-dispersive wavelength selection of the supercontinuum laser source is achieved with a microelectromechanical Fabry–Perot interferometer. The tunable light source enables the use of any monochromatic imaging sensor with a suitable spectral sensitivity for hyperspectral imaging. The imager is characterized and demonstrated in the laboratory for remote detection of ice.
- 28 October 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (21) , 5294-5297
Optical interruption of a quantum cascade laser for cavity ring-down spectroscopy
We demonstrate optical unlocking of a cavity resonance in a mid-infrared (MIR) quantum cascade laser (QCL) cavity ring-down spectrometer using a low-power multimode near-infrared (NIR) laser diode. A NIR laser with a center wavelength of 1310 nm is injected into a QCL whose amplitude and frequency are modulated as a result. The shift in frequency leads to a rapid interruption of the cavity resonance. The optical method is compared to cavity interruption with a current step by measuring ring-down times in a high-finesse optical cavity, coupled with a QCL with a center wavelength of 4.5 μm. The results indicate the comparable performance of the all-optical method with the more conventional current modulation, but with significantly reduced bandwidth requirements for the QCL driver, opening the way to other potential applications in MIR laser spectroscopy.
- 28 October 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (21) , 5294-5297
Optical interruption of a quantum cascade laser for cavity ring-down spectroscopy
We demonstrate optical unlocking of a cavity resonance in a mid-infrared (MIR) quantum cascade laser (QCL) cavity ring-down spectrometer using a low-power multimode near-infrared (NIR) laser diode. A NIR laser with a center wavelength of 1310 nm is injected into a QCL whose amplitude and frequency are modulated as a result. The shift in frequency leads to a rapid interruption of the cavity resonance. The optical method is compared to cavity interruption with a current step by measuring ring-down times in a high-finesse optical cavity, coupled with a QCL with a center wavelength of 4.5 μm. The results indicate the comparable performance of the all-optical method with the more conventional current modulation, but with significantly reduced bandwidth requirements for the QCL driver, opening the way to other potential applications in MIR laser spectroscopy.
- Open Access
Active Hyperspectral Sensor Based on MEMS Fabry-Pérot Interferometer
An active hyperspectral sensor (AHS) was developed for target detection and classification applications. AHS measures light scattered from a target, illuminated by a broadband near-infrared supercontinuum (SC) light source. Spectral discrimination is based on a voltage-tunable MEMS Fabry-Pérot Interferometer (FPI). The broadband light is filtered by the FPI prior to transmitting, allowing for a high spectral-power density within the eye-safety limits. The approach also allows for a cost-efficient correction of the SC instability, employing a non-dispersive reference detector. A precision of 0.1% and long-term stability better than 0.5% were demonstrated in laboratory tests. The prototype was mounted on a car for field measurements. Several road types and objects were distinguished based on the spectral response of the sensor targeted in front of the car.
Open AccessActive Hyperspectral Sensor Based on MEMS Fabry-Pérot Interferometer
An active hyperspectral sensor (AHS) was developed for target detection and classification applications. AHS measures light scattered from a target, illuminated by a broadband near-infrared supercontinuum (SC) light source. Spectral discrimination is based on a voltage-tunable MEMS Fabry-Pérot Interferometer (FPI). The broadband light is filtered by the FPI prior to transmitting, allowing for a high spectral-power density within the eye-safety limits. The approach also allows for a cost-efficient correction of the SC instability, employing a non-dispersive reference detector. A precision of 0.1% and long-term stability better than 0.5% were demonstrated in laboratory tests. The prototype was mounted on a car for field measurements. Several road types and objects were distinguished based on the spectral response of the sensor targeted in front of the car.
- Open Access
Determining Biogenic Content of Biogas by Measuring Stable Isotopologues 12CH4, 13CH4, and CH3D with a Mid-Infrared Direct Absorption Laser Spectrometer
A tunable laser absorption spectrometer (TLAS) was developed for the simultaneous measurement of δ13C and δD values of methane (CH4). A mid-infrared interband cascade laser (ICL) emitting around 3.27 µm was used to measure the absorption of the three most abundant isotopologues in CH4 with a single, mode-hop free current sweep. The instrument was validated against methane samples of fossil and biogenic origin with known isotopic composition. Three blended mixtures with varied biogenic content were prepared volumetrically, and their δ13C and δD values were determined. Analysis demonstrated that, provided the isotopic composition of the source materials was known, the δ13C and δD values alone were sufficient to determine the biogenic content of the blended samples to within 1.5%.
Open AccessDetermining Biogenic Content of Biogas by Measuring Stable Isotopologues 12CH4, 13CH4, and CH3D with a Mid-Infrared Direct Absorption Laser Spectrometer
A tunable laser absorption spectrometer (TLAS) was developed for the simultaneous measurement of δ13C and δD values of methane (CH4). A mid-infrared interband cascade laser (ICL) emitting around 3.27 µm was used to measure the absorption of the three most abundant isotopologues in CH4 with a single, mode-hop free current sweep. The instrument was validated against methane samples of fossil and biogenic origin with known isotopic composition. Three blended mixtures with varied biogenic content were prepared volumetrically, and their δ13C and δD values were determined. Analysis demonstrated that, provided the isotopic composition of the source materials was known, the δ13C and δD values alone were sufficient to determine the biogenic content of the blended samples to within 1.5%.
- 1 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Long range active hyperspectral target identification using near-IR supercontinuum light source
The aim of this work was to develop a cost effective hyperspectral instrument and to demonstrate the acquisition of IR reflection spectra over long distances.
- 1 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Long range active hyperspectral target identification using near-IR supercontinuum light source
The aim of this work was to develop a cost effective hyperspectral instrument and to demonstrate the acquisition of IR reflection spectra over long distances.