Vyacheslav V. Kuzmin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vyacheslav V. Kuzmin has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Murat S. Tagirov
Kazan Federal University, Kazan, Russia
22 shared publications - Alexander V. Klochkov
Kazan Federal University
20 shared publications - Egor M. Alakshin
Kazan Federal University, Institute of Physics, Kremlevskaya 18, Kazan 420008, Russian Federation
16 shared publications - Kajum R. Safiullin
Institute for Biological Interfaces 4, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
16 shared publications - Rasul R. Gazizulin
University of Florida
11 shared publications - Andrey Stanislavovas
quantum electronics and radiospectroscopy, Kazan Federal University, Kremlyovskaja 18, Kazan', Tatarstan, 420008, RUSSIAN FEDERATION
6 shared publications
Latest Publications
- 13 November 2026
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
Determination of Paramagnetic Layer Localization Depth in LaF3-Based Gd3+ Delta-Doped Nanoparticles Using 3He NMR
Various model systems of core LaF3 and core–shell–shell LaF3–LaF3:Gd-LaF3 (delta-doped) nanoparticles were synthesized and studied by nuclear magnetic resonance (NMR) of adsorbed 3He in the 1.5–7 K temperature range and by 19F NMR in the 1.5–70 K temperature range. The NMR technique, employing T1 measurements of 3He adsorbed on a surface covered with various amounts of solid nitrogen, was applied to the synthesized nanoparticles to determine the depth of impurity localization, validate the approach, and control the synthesis of delta-doped magnetic nanoparticles. The paramagnetic impurities were introduced into the nanoparticles via a three-step synthesis by coating pill-shaped diamagnetic LaF3 particles (26 × 40 nm2 in size) with a thin (∼0.3 nm) LaF3:Gd3+ layer and subsequently coating them with a layer of diamagnetic LaF3 with a thickness of 0.5–1.0 nm (core–shell–shell structure). All experiments were performed in the 15–18 MHz NMR frequency range for both probe nuclei. The observed systematic deviation between the outer shell thicknesses determined from 3He NMR measurements and the expected values reflects unavoidable imperfections in the synthesis steps. Notably, the sensitivity of adsorbed 3He NMR to such deviations makes it a powerful tool for monitoring and controlling the synthesis of core–shell–shell nanoparticles. In sharp contrast to 19F NMR, which shows no sensitivity to shell thicknesses or even the Gd3+ concentration, the adsorbed 3He NMR technique is highly sensitive and therefore better-suited for characterizing such structures. The applied approach was verified under different conditions and can therefore be used for characterizing various magnetic nanoparticles and controlling their synthesis.
- 13 November 2026
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
Determination of Paramagnetic Layer Localization Depth in LaF3-Based Gd3+ Delta-Doped Nanoparticles Using 3He NMR
Various model systems of core LaF3 and core–shell–shell LaF3–LaF3:Gd-LaF3 (delta-doped) nanoparticles were synthesized and studied by nuclear magnetic resonance (NMR) of adsorbed 3He in the 1.5–7 K temperature range and by 19F NMR in the 1.5–70 K temperature range. The NMR technique, employing T1 measurements of 3He adsorbed on a surface covered with various amounts of solid nitrogen, was applied to the synthesized nanoparticles to determine the depth of impurity localization, validate the approach, and control the synthesis of delta-doped magnetic nanoparticles. The paramagnetic impurities were introduced into the nanoparticles via a three-step synthesis by coating pill-shaped diamagnetic LaF3 particles (26 × 40 nm2 in size) with a thin (∼0.3 nm) LaF3:Gd3+ layer and subsequently coating them with a layer of diamagnetic LaF3 with a thickness of 0.5–1.0 nm (core–shell–shell structure). All experiments were performed in the 15–18 MHz NMR frequency range for both probe nuclei. The observed systematic deviation between the outer shell thicknesses determined from 3He NMR measurements and the expected values reflects unavoidable imperfections in the synthesis steps. Notably, the sensitivity of adsorbed 3He NMR to such deviations makes it a powerful tool for monitoring and controlling the synthesis of core–shell–shell nanoparticles. In sharp contrast to 19F NMR, which shows no sensitivity to shell thicknesses or even the Gd3+ concentration, the adsorbed 3He NMR technique is highly sensitive and therefore better-suited for characterizing such structures. The applied approach was verified under different conditions and can therefore be used for characterizing various magnetic nanoparticles and controlling their synthesis.
- 9 September 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (3)
Influence of different radio-frequency discharge conditions and impurities on the process of He 3 nuclear polarization in magnetized plasma
- 9 September 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (3)
Influence of different radio-frequency discharge conditions and impurities on the process of He 3 nuclear polarization in magnetized plasma
- 2 July 2025
- Published by Elsevier in Journal of Applied Geophysics
- Vol. 241
Helium-3 NMR as a valid probe to study pore distribution of clay-based rocks
- 2 July 2025
- Published by Elsevier in Journal of Applied Geophysics
- Vol. 241
Helium-3 NMR as a valid probe to study pore distribution of clay-based rocks
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Design of the experimental setup for Overhauser dynamic nuclear polarization in stray field of a superconducting magnet
We designed and constructed a low-field setup for the study of nuclear magnetic resonance (NMR) and Overhauser dynamic nuclear polarization (DNP) in the shimmed stray magnetic field of a superconducting magnet with a variable magnetic field (0–8.5 T). The experimental configuration is capable of exploring magnetic fields in the range of 0.5–30 mT by displacing the NMR/DNP probe from the superconducting magnet. Thanks to a constructed 3D gradient system comprising three coils wound on 3D-printed plastic holders, sufficient field homogeneity can be achieved (325 ppm in 0.7 ml volume, 98-fold homogeneity improvement) for strongly DNP-enhanced NMR signals or for measurements in concentrated solutions and porous media with broad NMR spectra. This setup allows us to study the magnetic field dependence of the Overhauser effect and underlying physical processes in aqueous solutions of radicals with an easy-to-built, low-cost, and low-power consumption magnet system. The design parameters of the gradient coils generating linear magnetic field gradients were optimized using the downhill simplex method in conjunction with magnetic field computations using Magpylib (a Python package). The NMR/DNP excitation chain allows for the use of a single broadband power amplifier to excite both nuclear and electronic spins and incorporates a custom-built NMR spectrometer for the generation and control of NMR and electron saturation pulses. In addition, we present a two-stage design for an NMR preamplifier, achieving a total gain of 68 dB, which combines a low-noise bipolar MMIC amplifier INA-02186 with an AD797 operational amplifier, enabling the detection of NMR signals over a frequency range of 30–1200 kHz. DNP tests performed using a TEMPOL solution in water at a field strength of 4 mT demonstrate the efficacy of the assembled system for studying the DNP effect at low magnetic fields with high sensitivity.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Design of the experimental setup for Overhauser dynamic nuclear polarization in stray field of a superconducting magnet
We designed and constructed a low-field setup for the study of nuclear magnetic resonance (NMR) and Overhauser dynamic nuclear polarization (DNP) in the shimmed stray magnetic field of a superconducting magnet with a variable magnetic field (0–8.5 T). The experimental configuration is capable of exploring magnetic fields in the range of 0.5–30 mT by displacing the NMR/DNP probe from the superconducting magnet. Thanks to a constructed 3D gradient system comprising three coils wound on 3D-printed plastic holders, sufficient field homogeneity can be achieved (325 ppm in 0.7 ml volume, 98-fold homogeneity improvement) for strongly DNP-enhanced NMR signals or for measurements in concentrated solutions and porous media with broad NMR spectra. This setup allows us to study the magnetic field dependence of the Overhauser effect and underlying physical processes in aqueous solutions of radicals with an easy-to-built, low-cost, and low-power consumption magnet system. The design parameters of the gradient coils generating linear magnetic field gradients were optimized using the downhill simplex method in conjunction with magnetic field computations using Magpylib (a Python package). The NMR/DNP excitation chain allows for the use of a single broadband power amplifier to excite both nuclear and electronic spins and incorporates a custom-built NMR spectrometer for the generation and control of NMR and electron saturation pulses. In addition, we present a two-stage design for an NMR preamplifier, achieving a total gain of 68 dB, which combines a low-noise bipolar MMIC amplifier INA-02186 with an AD797 operational amplifier, enabling the detection of NMR signals over a frequency range of 30–1200 kHz. DNP tests performed using a TEMPOL solution in water at a field strength of 4 mT demonstrate the efficacy of the assembled system for studying the DNP effect at low magnetic fields with high sensitivity.
- 3 August 2024
- Published by Elsevier in Surfaces and Interfaces
- Vol. 52
Study of magnetic phase transitions by helium-3 in DyF3 nanoparticles
- 3 August 2024
- Published by Elsevier in Surfaces and Interfaces
- Vol. 52
Study of magnetic phase transitions by helium-3 in DyF3 nanoparticles
- 6 February 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 127 (6) , 1459-1470
Diffusion Anisotropy of Gaseous Helium-3 in Ordered Aerogels at Low Temperatures
We report on the first observation of diffusion anisotropy of gaseous helium-3 entrapped in ordered aerogels at 4.2 K. The origins of 3He diffusion anisotropy in aerogels of different porosity are discussed. The correlations between gas diffusion coefficient and basic parameters of aerogels, such as porosity, fiber diameter, and fiber's degree of alignment, are inspected using simple diffusion simulations within the framework of classical diffusion model in both oriented and chaotic aerogels under conditions of diffuse (Knudsen diffusion) and specular reflections of atoms from the walls. The failure of the two-phase and Knudsen diffusion models at low temperature in isotropic and anisotropic aerogels is observed. The effect of a wall attractive potential on the gas dynamics is suspected to play a crucial role in the gas diffusion and its anisotropy. The rough theoretical estimates of that effect at low temperatures in aerogel space confirm this assumption. The observed peculiar diffusion is universal and is expected to occur with other probe gases at higher temperatures.
- 6 February 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 127 (6) , 1459-1470
Diffusion Anisotropy of Gaseous Helium-3 in Ordered Aerogels at Low Temperatures
We report on the first observation of diffusion anisotropy of gaseous helium-3 entrapped in ordered aerogels at 4.2 K. The origins of 3He diffusion anisotropy in aerogels of different porosity are discussed. The correlations between gas diffusion coefficient and basic parameters of aerogels, such as porosity, fiber diameter, and fiber's degree of alignment, are inspected using simple diffusion simulations within the framework of classical diffusion model in both oriented and chaotic aerogels under conditions of diffuse (Knudsen diffusion) and specular reflections of atoms from the walls. The failure of the two-phase and Knudsen diffusion models at low temperature in isotropic and anisotropic aerogels is observed. The effect of a wall attractive potential on the gas dynamics is suspected to play a crucial role in the gas diffusion and its anisotropy. The rough theoretical estimates of that effect at low temperatures in aerogel space confirm this assumption. The observed peculiar diffusion is universal and is expected to occur with other probe gases at higher temperatures.
- Open Access
Temperature-related effects in the polarization of atoms in a magnetized plasma as a promising feature towards high $^3$He nuclear polarization
We report on further investigation of nuclear hyperpolarization of helium-3 in magnetized plasma at a magnetic field of 3.66 T and at different experimental conditions in a dual cell of relatively large volume, compared to those reported in the original polarization of atoms in a magnetized plasma (PAMP) paper by Maul $\textit{et al.}$ [Phys. Rev. A. $\textbf{98}$, 063405 (2018)]. It was found that steady-state nuclear polarizations obtained by this method strongly increase with temperature and rf gas discharge power. We managed to reach almost 8% at the highest possible temperature in our setup which is to date the highest polarization obtained by this method at 10 mbar. It was also shown that atomic oxygen in plasma, considered as an impurity, could be a good probe of plasma parameters relevant for the PAMP process, either the temperature or the metastable $^3$He density. The polarization build-up rates with the cell temperature stabilized near room temperature are found to be of the order of 1 s$^{-1}$ which is by two orders of magnitude faster than was reported in the original PAMP paper for the same filling pressure. These observations promise a further optimization of experimental conditions towards strong and fast hyperpolarization by this method.Open AccessTemperature-related effects in the polarization of atoms in a magnetized plasma as a promising feature towards high $^3$He nuclear polarization
We report on further investigation of nuclear hyperpolarization of helium-3 in magnetized plasma at a magnetic field of 3.66 T and at different experimental conditions in a dual cell of relatively large volume, compared to those reported in the original polarization of atoms in a magnetized plasma (PAMP) paper by Maul $\textit{et al.}$ [Phys. Rev. A. $\textbf{98}$, 063405 (2018)]. It was found that steady-state nuclear polarizations obtained by this method strongly increase with temperature and rf gas discharge power. We managed to reach almost 8% at the highest possible temperature in our setup which is to date the highest polarization obtained by this method at 10 mbar. It was also shown that atomic oxygen in plasma, considered as an impurity, could be a good probe of plasma parameters relevant for the PAMP process, either the temperature or the metastable $^3$He density. The polarization build-up rates with the cell temperature stabilized near room temperature are found to be of the order of 1 s$^{-1}$ which is by two orders of magnitude faster than was reported in the original PAMP paper for the same filling pressure. These observations promise a further optimization of experimental conditions towards strong and fast hyperpolarization by this method. - 1 August 2022
- Published by American Physical Society (APS) in Physical Review A
- Vol. 106 (2) , 023101
Temperature-related effects in the polarization of atoms in a magnetized plasma as a promising feature towards high nuclear polarizationWe report on further investigation of nuclear hyperpolarization of in magnetized plasma at a magnetic field of 3.66 T and at different experimental conditions in a dual cell of relatively large volume, compared to those reported in the original polarization of atoms in a magnetized plasma (PAMP) paper by Maul et al. [ Phys. Rev. A 98, 063405 (2018)]. It was found that steady-state nuclear polarizations obtained by this method strongly increase with temperature and rf gas discharge power. We managed to reach almost 8% at the highest possible temperature in our setup which is to date the highest polarization obtained by this method at 10 mbar. It was also shown that atomic oxygen in plasma, considered as an impurity, could be a good probe of plasma parameters relevant for the PAMP process, either in the temperature or the metastable density. The polarization buildup rates with the cell temperature stabilized near room temperature are found to be of the order of 1 , which is by two orders of magnitude faster than was reported in the original PAMP paper for the same filling pressure. These observations promise a further optimization of experimental conditions towards strong and fast hyperpolarization by this method.- 1 August 2022
- Published by American Physical Society (APS) in Physical Review A
- Vol. 106 (2) , 023101
Temperature-related effects in the polarization of atoms in a magnetized plasma as a promising feature towards high nuclear polarizationWe report on further investigation of nuclear hyperpolarization of in magnetized plasma at a magnetic field of 3.66 T and at different experimental conditions in a dual cell of relatively large volume, compared to those reported in the original polarization of atoms in a magnetized plasma (PAMP) paper by Maul et al. [ Phys. Rev. A 98, 063405 (2018)]. It was found that steady-state nuclear polarizations obtained by this method strongly increase with temperature and rf gas discharge power. We managed to reach almost 8% at the highest possible temperature in our setup which is to date the highest polarization obtained by this method at 10 mbar. It was also shown that atomic oxygen in plasma, considered as an impurity, could be a good probe of plasma parameters relevant for the PAMP process, either in the temperature or the metastable density. The polarization buildup rates with the cell temperature stabilized near room temperature are found to be of the order of 1 , which is by two orders of magnitude faster than was reported in the original PAMP paper for the same filling pressure. These observations promise a further optimization of experimental conditions towards strong and fast hyperpolarization by this method.- 23 November 2021
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 64 (6) , 911-916
Cryogenic Purification of Helium and its Use for Preparing Polarization Cells and Carrying Out Non-Optical Polarization of 3He Nuclei
The application of the cryogenic technique for purifying helium isotopes and their mixtures from concomitant admixtures is described. This technique is suitable for the purpose of 3He polarization using the PAMP (polarization of atoms in a magnetized plasma) method. It is based on a long gas deposit in a tube at liquid helium temperature when the tube is immersed into a standard storage dewar. The observed optical emission spectra of helium plasma and the estimate of the 3He polarization (approximately 1%) at room temperature evidence the effectiveness of the described procedures for helium purification and cell cleaning.
- 23 November 2021
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 64 (6) , 911-916
Cryogenic Purification of Helium and its Use for Preparing Polarization Cells and Carrying Out Non-Optical Polarization of 3He Nuclei
The application of the cryogenic technique for purifying helium isotopes and their mixtures from concomitant admixtures is described. This technique is suitable for the purpose of 3He polarization using the PAMP (polarization of atoms in a magnetized plasma) method. It is based on a long gas deposit in a tube at liquid helium temperature when the tube is immersed into a standard storage dewar. The observed optical emission spectra of helium plasma and the estimate of the 3He polarization (approximately 1%) at room temperature evidence the effectiveness of the described procedures for helium purification and cell cleaning.