AGAshok Sunil Gavaskar

Ashok Sunil Gavaskar

*This is an algorithmically generated author record based on publicly available information.

Ashok Sunil Gavaskar has a total of 82 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Subchondral Shelf Support Plating for Impacted Radial Head Fractures: Surgical Technique and Case Series

    by Ashok S. Gavaskar, Parthasarathy Srinivasan, Prakash Ayyadurai

    Subchondral bone impaction at the level of the radial neck, usually present at the anterior or lateral quadrant, can be an associated feature in radial head fractures. Buttress plating principles suggest that subchondral zones of impaction are best supported by an implant positioned directly on the site of impaction to resist secondary collapse. The anatomical considerations limit the standard radial head plating technique to a narrow safe zone. Therefore, irrespective of the zone of impaction, the standard plating zone remains the same, which may not provide the best possible mechanical construct for radial head fractures where the zone of impaction lies outside the safe zone for plating. In this study, the authors present an alternate subchondral shelf plating technique performed through the zone of impaction. The technique involves supporting the disimpacted radial head using a bent mini-fragment plate that acts as a shelf along with supplemental fixation. The shelf plate remains extra-articular, recessed below the radial head and the proximal radioulnar joint, with scope for impingement-free fixation along the entire circumference of the radial head. The technique was used in 13 adult patients and yielded excellent outcomes. Radiological healing was achieved in all patients with maintenance of reduction. The mean Mayo Elbow Performance Score and the quick DASH score were 96.5 ± 6.5 and 4.9 ± 3.3, respectively, at a mean follow-up of 20 ± 8 months.

  • Volar marginal fragment escape in distal radius fractures. Results of salvage with a volar open wedge articular reorientation osteotomy

    by Ashok S. Gavaskar, Parthasarathy Srinivasan, Prakash Ayyadurai, Naveen C. Tummala


  • Complications After Internal Fixation of Acetabular Fractures in the Elderly: A Retrospective Review of Incidence and Risk Factors

    by Ashok S. Gavaskar, Rodrigo Pesantez Hoyos, Ramesh Kumar Sen

    Objective To investigate the incidence and risk factors for complications after open reduction and internal fixation (ORIF) of acetabular fractures in the elderly. Methods Patients over 60 years undergoing ORIF from 2015 to 2023 were reviewed. The primary outcome measure was incidence of medical and surgical complications, including the 1-year mortality rate. Age, gender, fracture pattern, surgical approach and medical comorbidities (using the American Society of Anesthesiologists, ASA grade) were examined for association with fracture reduction, arthritis, hospital stay and patient-reported outcome measures (Hip Disability and Osteoarthritis Outcome Score, HOOS—12). Results The study cohort included 28 males and 24 females (52 patients). 12 patients (23%) experienced a medical complication that needed active treatment and 6 patients (12%) died within the first year. 31 patients (60%) experienced one or more surgery-related complication of which 17 patients (33%) needed revision procedures. Higher age and associated fracture patterns were strongly associated with non-anatomical reduction and post-traumatic arthritis. Surgery needing more than one approach, higher age and ASA grades were associated with prolonged hospital stay. Higher age was the only factor which influenced the HOOS-12 scores negatively. Conclusions A high incidence of medical and surgical complications was observed in elderly patients undergoing ORIF for acetabular fractures. Higher age was consistently associated with complications and poor hip function. More complex fracture patterns, associated medical comorbidities and need for a more extensive surgery were also associated with higher incidence of complications. Level of Evidence IV.

  • Open Access

    Anterior chondral buttress plating for complex coronal shear fractures of the distal humerus. A retrospective case series

    by Ashok S. Gavaskar, Parthasarathy Srinivasan, Prakash Ayyadurai, Bejoy P. George, Abraham M. Antony, K.N. Jotheesvar

  • Plate-Nail Construct Using a Realign, Compress and Nail Strategy Without Supplemental Bone Grafting for Subtrochanteric Nonunions

    by Ashok S. Gavaskar, Parthasarathy Srinivasan, Prakash Ayyadurai, Naveen C. Tummala

    OBJECTIVES: To assess the healing rate and improvements in hip and lower limb function using a tensioned plate-nail construct without bone grafting in the treatment of subtrochanteric nonunions. METHODS: Setting: Two urban trauma centers in India. Design: Retrospective cohort study. Patient Selection Criteria: Patients from 2015 to 2023 operated for subtrochanteric fracture nonunions (AO/OTA 31 A3.1, 2, and 3) using a tensioned plate-nail construct without bone grafting. Outcome Measures and Comparisons: The primary outcome measure was healing of the nonunion after repair using the plate-nail construct without bone grafting. Secondary outcome measures were improvements in neck-shaft angle, limb length discrepancy, Harris hip score, lower extremity functional scale postsurgery, and the need for further surgical procedures. RESULTS: The study cohort included 26 men and 20 women (46 patients) with a mean age of 60 years (range 29–82 years). The nonunion healed in 44 patients (96%) after fixation with the plate-nail construct. One patient needed another revision surgery to achieve healing. Significant improvements were seen in neck-shaft angle (127 ± 4.5 vs. 111 ± 7 degrees, P < 0.001) and limb length discrepancy (0.5 ± 0.4 vs. 1.5 ± 0.8 cm, P = 0.02) postsurgery. Functional assessment in 39 patients at a mean follow-up of 40 ± 20 months showed significant improvements in Harris hip score (85 ± 8 vs. 36 ± 8 points, P < 0.001) and lower extremity functional scale (66 ± 7 vs. 22 ± 6 points, P < 0.001). CONCLUSIONS: Consistent healing with significant improvements in limb length, hip, and lower limb function were achieved using the plate-nail-assisted technique of realignment and nonunion compression without supplemental bone grafting in the treatment of subtrochanteric nonunions. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  • Breakage of 2.7-mm Variable Angle Locking Screws at Implant Removal. Study of Incidence and Risk Factors During Removal of Distal Humerus and Distal Tibia Implants

    by Ashok S. Gavaskar, Parthasarathy Srinivasan, Prakash Ayyadurai, Naveen Chowdary Tummala

    OBJECTIVES: To investigate the occurrence and risk factors for breakage of 2.7-mm variable angle (VA) locking screws from DePuy—Synthes during removal. METHODS: Design: Retrospective cohort study. Setting: Two urban tertiary care hospitals in India. Patient Selection Criteria: Patients from 2018 to 2024, undergoing removal of VA locked implants after healing of distal humerus (AO/OTA 13—A2,3 and 13—C1,2,3) and distal tibia fractures (AO/OTA 43—A1,2,3 and C2,3). Outcome measures and comparisons: The primary outcome measure was breakage of 2.7-mm VA locked screws. Difference in breakage between titanium and stainless-steel screws were examined. Age, sex, bone quality (measured in Hounsfield units using preoperative computerized tomography), body mass index, screw length, and time between surgery and implant removal were analyzed for association with screw breakage. RESULTS: Of 28 patients included, 16 patients underwent removal of titanium implants from the distal humerus and 12 patients underwent removal of stainless-steel implants from the distal tibia. There were 16 men and 12 women with a mean age of 41 years range (20 - 70, SD 15) 95 of 254 VA locking screws were reported broken during removal. 46 of 105 (43.8%) stainless-steel screws broke compared with 49 of 149 (32.8%) titanium screws. This difference was not statistically significant ( P = 0.234). Younger age (β = −0.48, SE = 0.2, P = 0.022), longer screw length (β = 0.21, SE = 0.23, P = 0.038), and longer interval between surgery and removal (β = 0.43, SE = 0.42, P = 0.002) were associated with a higher incidence of screw breakage. CONCLUSIONS: A high incidence of breakage was observed during removal of 2.7-mm VA titanium and stainless-steel locking screws. Younger patients, longer screws, and late removal were associated with more risk for breakage. It is important for patients undergoing removal of these implants to be adequately informed and surgeons should be prepared to address this challenge intraoperatively. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  • The double floating extremity phenomenon: case studies and evidence-based perspectives

    by Abhay Elhence, Sandeep Kumar Yadav, Aakarsh Aggarwal, Manveer Singh, Ashok Sunil Gavaskar

    Background The “double floating extremity” phenomenon, characterized by simultaneous ipsilateral floating hip and floating knee injuries, is an extremely rare and complex orthopaedic condition. It often results from high-velocity trauma and is associated with significant systemic injuries, posing unique challenges in management due to a lack of standardized treatment protocols. Methods This study reviews thirteen cases of double floating extremities, analysing clinical outcomes, management strategies, and functional recovery. We assessed functional outcome using KFS (knee function score), KSS (knee society score), and Majeed score, Merle d’Aubigné score, LEFS (lower extremity function score) scores at follow-up of 3 months, 6 months and at/more than 1 year. Results Of thirteen patients, eleven demonstrated good-to-excellent functional outcomes at long-term follow-up (≥ 12 months), with mean Merle d’Aubigné score 15.36 (range 14–17 with SD-0.96) and mean LEFS score 65.27(range 50–74 with SD: 7.01). The mean injury severity score (ISS) for this study was 22.5 (range 10–50 with SD: 12.4). Both patients with Common Peroneal Nerve CPN palsy achieved full dorsiflexion recovery. Two patients succumbed to systemic complications, highlighting the severity of associated injuries. Early femur and tibia fixation followed by delayed pelvic fixation emerged as a practical approach to minimize systemic complications and optimize outcomes. Conclusion Double floating extremity injuries are rare but severe, requiring a systematic phased approach with staged fixation and multidisciplinary care. Incorporating injury severity score provides objective quantification of systemic injury burden. Staged fixation strategies tailored to the patient’s systemic condition can improve functional outcomes. However, the scarcity of the literature and variability in treatment methodologies underscore the need for further studies to establish standardized protocols.


  • Hoffa Fractures: Current Understanding and Surgical Treatment Strategies

    by Ashok S. Gavaskar, Vaibhav Bagaria, Abhay Elhence, Vivek Trikha

    Coronal fractures of the distal femur, although uncommon in isolation, represent a distinct fracture pattern different from other distal femur fracture subtypes. Popularly known as the Hoffa fractures, these injuries are characterized by obliquely oriented fracture lines in the coronal plane with or without articular comminution. These partial articular fractures are commonly seen on the lateral condyle as a result of translational shearing forces on the posterior femoral condyle with the knee in flexion. These fractures were often missed before the advent of routine use of CT scans because they appear subtle on plain radiographs. The frequent presence of major and more proximal associated skeletal injuries is another reason that these fractures may be missed in the initial evaluation. Hoffa fractures, being articular injuries, need anatomical reduction and a stable fixation to facilitate early knee motion and prevent arthrofibrosis. Surgical treatment of these fractures needs a careful understanding of various fracture patterns, presence of comminution, articular impaction, fragment size, and location to choose the optimal surgical approach, reduction, and fixation techniques. This review will outline strategies for surgical management of Hoffa fractures and discuss outcomes and complications based on published evidence.