Onur Afacan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Onur Afacan has a total of 210 co-authors. Here are the top co-authors by number of shared publications:
- Simon Keith Warfield
Department of Radiology Boston Children's Hospital Boston Massachusetts USA
32 shared publications - Camilo Jaimes
Department of Radiology, Massachusetts General Hospital, Boston, United States
16 shared publications Simon K. Warfield
Harvard Medical School Boston Massachusetts USA
13 shared publicationsAli Gholipour
Harvard Medical School Boston Massachusetts USA
11 shared publications- Sila Kurugol
Computational Radiology Laboratory, Department of Radiology, Boston Children’s Hospital, Boston, Massachusetts, USA
11 shared publications - Ali Gholipour
Harvard Medical School
8 shared publications
Latest Publications
- 28 July 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (6) , 2822-2830
Combining Prospective and Retrospective Motion Correction, Using the Scout Accelerated Motion Estimation and Reduction ( SAMER ) Framework, for Rapid and Motion‐Robust 2D TSE Imaging
Purpose: Motion artifacts remain a major challenge in applying multi‐shot 2D imaging to motion prone patient populations. Through‐plane motion is especially problematic, where the lack of encoding cannot be easily recovered, even using deep‐learning (DL)‐regularized reconstruction. We demonstrate the benefits of combining prospective and retrospective motion correction, where the Scout Accelerated Motion Estimation and Reduction (SAMER) technique is utilized for on‐the‐fly motion estimation with field‐of‐view (FoV) updates along with retrospective correction of potential residual motion. Methods: Four prospective motion correction (pMoCo) strategies were implemented within a custom 2D turbo‐spin‐echo (TSE) SAMER enabled sequence. They were evaluated in vivo across representative subject motion, with associated simulations to characterize artifacts and the correction performance. In addition, motion trajectories measured during inpatient clinical exams were used to further demonstrate the robustness of the combined motion correction approach. Results: Prospectively applying FoV updates significantly improved the image quality of SAMER reconstructions. Simulated artifact patterns were shown to closely match those observed in vivo, and across 274 simulations using clinical motion trajectories, the combined approach reduced NRMSE in 90% of moderate‐to‐severe motion cases and significantly decreased the overall reconstruction error. Conclusion: Utilizing on‐the‐fly SAMER motion estimates, a combined prospective and retrospective motion correction approach was demonstrated for 2D TSE imaging. The proposed method improved image quality in several representative in vivo motion experiments and across simulations of a wide range of clinical inpatient motion conditions. In addition, simulated artifact patterns were shown to closely match those observed in vivo. This capability should enable on‐the‐fly prediction of motion artifacts for efficient/intelligent acquisition strategies for the most challenging motion scenarios.
- 28 July 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (6) , 2822-2830
Combining Prospective and Retrospective Motion Correction, Using the Scout Accelerated Motion Estimation and Reduction ( SAMER ) Framework, for Rapid and Motion‐Robust 2D TSE Imaging
Purpose: Motion artifacts remain a major challenge in applying multi‐shot 2D imaging to motion prone patient populations. Through‐plane motion is especially problematic, where the lack of encoding cannot be easily recovered, even using deep‐learning (DL)‐regularized reconstruction. We demonstrate the benefits of combining prospective and retrospective motion correction, where the Scout Accelerated Motion Estimation and Reduction (SAMER) technique is utilized for on‐the‐fly motion estimation with field‐of‐view (FoV) updates along with retrospective correction of potential residual motion. Methods: Four prospective motion correction (pMoCo) strategies were implemented within a custom 2D turbo‐spin‐echo (TSE) SAMER enabled sequence. They were evaluated in vivo across representative subject motion, with associated simulations to characterize artifacts and the correction performance. In addition, motion trajectories measured during inpatient clinical exams were used to further demonstrate the robustness of the combined motion correction approach. Results: Prospectively applying FoV updates significantly improved the image quality of SAMER reconstructions. Simulated artifact patterns were shown to closely match those observed in vivo, and across 274 simulations using clinical motion trajectories, the combined approach reduced NRMSE in 90% of moderate‐to‐severe motion cases and significantly decreased the overall reconstruction error. Conclusion: Utilizing on‐the‐fly SAMER motion estimates, a combined prospective and retrospective motion correction approach was demonstrated for 2D TSE imaging. The proposed method improved image quality in several representative in vivo motion experiments and across simulations of a wide range of clinical inpatient motion conditions. In addition, simulated artifact patterns were shown to closely match those observed in vivo. This capability should enable on‐the‐fly prediction of motion artifacts for efficient/intelligent acquisition strategies for the most challenging motion scenarios.
- 29 April 2026
- Published by Springer Nature in Pediatric Radiology
- p. 1-13
Comparison of dynamic contrast-enhanced MRI versus MAG-3 scintigraphy for differential renal function assessment in pediatric patients
Background Measuring differential renal function (DRF) is critical for managing children with congenital and acquired urological diseases. MAG-3 renal scintigraphy is the most widely used clinical technique; dynamic contrast-enhanced MRI (DCE-MRI) provides a radiation-free and high-resolution alternative method for assessing DRF. Objective To evaluate the agreement between DRF values derived from DCE-MRI and MAG-3 scintigraphy-derived DRF in pediatric patients. Materials and methods This retrospective study included 23 pediatric patients (age range, 3 months-20 years; mean±SD, 8.3±7.4 years) who underwent DCE-MRI embedded in MR urography (MRU) protocol and MAG-3 studies within 6 months. DCE-MRI was performed using a golden-angle radial dynamic stack-of-stars acquisition with golden-angle sparse parallel (GRASP) reconstruction, and analyzed the renal filtration rate with a two-compartment tracer kinetic model. DRF values from DCE-MRI were compared with those from MAG-3, using both default (n=23) and C-shaped background regions for MAG-3 analysis, where raw data were available (n=16). Agreement was evaluated using Bland–Altman analysis, Pearson and concordance correlations, and paired statistical tests. Results With default MAG-3 background analysis (n=23), mean DRF difference (MAG-3 minus DCE-MRI) was 0.4% (95% CI, -3.3% to 4.2%), with 95% limits of agreement of -16.7% to +17.5%. Concordance correlation coefficient (CCC) was 0.870 (95% CI, 0.718–0.942). Within the pre-defined clinically acceptable margin of ±10%, 78.3% (18/23) of cases fell, with a mean absolute difference of 6.1%. With C-shaped background subtraction in the subset with available raw MAG-3 data (n=16), mean difference was -2.3% (95% CI, -6.7% to 2.0%), limits of agreement -18.3% to +13.6%, and CCC 0.845 (95% CI, 0.614–0.943). Pearson correlation was strong in both analyses (n=23: r=0.872, 95% CI, 0.719–0.945; n=16: r=0.866, 95% CI, 0.648–0.953; both P<0.001). No clinically significant systematic or proportional bias was detected in either analysis. Conclusion DCE-MRI demonstrates strong linear association and concordance with MAG-3 scintigraphy for pediatric differential renal function assessment with no clinically significant systematic bias, though the observed measurement variability indicates caution is warranted when comparing values near surgical decision thresholds. C-shaped background correction is recommended for MAG-3 in hydronephrotic kidneys to optimize inter-modality agreement. Graphical Abstract The alternative text for this image may have been generated using AI.
- 29 April 2026
- Published by Springer Nature in Pediatric Radiology
- p. 1-13
Comparison of dynamic contrast-enhanced MRI versus MAG-3 scintigraphy for differential renal function assessment in pediatric patients
Background Measuring differential renal function (DRF) is critical for managing children with congenital and acquired urological diseases. MAG-3 renal scintigraphy is the most widely used clinical technique; dynamic contrast-enhanced MRI (DCE-MRI) provides a radiation-free and high-resolution alternative method for assessing DRF. Objective To evaluate the agreement between DRF values derived from DCE-MRI and MAG-3 scintigraphy-derived DRF in pediatric patients. Materials and methods This retrospective study included 23 pediatric patients (age range, 3 months-20 years; mean±SD, 8.3±7.4 years) who underwent DCE-MRI embedded in MR urography (MRU) protocol and MAG-3 studies within 6 months. DCE-MRI was performed using a golden-angle radial dynamic stack-of-stars acquisition with golden-angle sparse parallel (GRASP) reconstruction, and analyzed the renal filtration rate with a two-compartment tracer kinetic model. DRF values from DCE-MRI were compared with those from MAG-3, using both default (n=23) and C-shaped background regions for MAG-3 analysis, where raw data were available (n=16). Agreement was evaluated using Bland–Altman analysis, Pearson and concordance correlations, and paired statistical tests. Results With default MAG-3 background analysis (n=23), mean DRF difference (MAG-3 minus DCE-MRI) was 0.4% (95% CI, -3.3% to 4.2%), with 95% limits of agreement of -16.7% to +17.5%. Concordance correlation coefficient (CCC) was 0.870 (95% CI, 0.718–0.942). Within the pre-defined clinically acceptable margin of ±10%, 78.3% (18/23) of cases fell, with a mean absolute difference of 6.1%. With C-shaped background subtraction in the subset with available raw MAG-3 data (n=16), mean difference was -2.3% (95% CI, -6.7% to 2.0%), limits of agreement -18.3% to +13.6%, and CCC 0.845 (95% CI, 0.614–0.943). Pearson correlation was strong in both analyses (n=23: r=0.872, 95% CI, 0.719–0.945; n=16: r=0.866, 95% CI, 0.648–0.953; both P<0.001). No clinically significant systematic or proportional bias was detected in either analysis. Conclusion DCE-MRI demonstrates strong linear association and concordance with MAG-3 scintigraphy for pediatric differential renal function assessment with no clinically significant systematic bias, though the observed measurement variability indicates caution is warranted when comparing values near surgical decision thresholds. C-shaped background correction is recommended for MAG-3 in hydronephrotic kidneys to optimize inter-modality agreement. Graphical Abstract The alternative text for this image may have been generated using AI.
- 30 March 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (1) , 201-208
Comparison of Myeloarchitectonic Feature Recognition of the Primary Visual Cortex at 7 T Relative to 3 T MRI
Background: The stria of Gennari (SoG) is a densely myelinated band within layer IVb of the primary visual cortex (V1) and represents the only cortical laminar structure visible macroscopically in vivo. Ultrahigh‐field MRI may improve its detection and conspicuity. Purpose: To quantitatively and qualitatively compare the in vivo appearance of the SoG at 3 versus 7 T using matched high‐resolution T 2 ‐weighted fast spin‐echo MRI. Study Type: Prospective. Population: A total of 12 subjects (6 female, 6 male; median age, 17 years; range, 15–24 years) with pediatric‐onset epilepsy. Field Strength/Sequence: 3 and 7 T MRI, T 2 ‐weighted fast spin‐echo, acquired within 1 month of each other. Assessment: Cortical line profiles per subject were extracted orthogonally to the calcarine sulcus in V1. Quantitative metrics included peak‐valley distance, Δ‐signal (peak‐valley difference), and contrast ratio (CR). Two blinded neuroradiologists and a radiologist independently rated SoG conspicuity using a 5‐point Likert scale. Statistical Tests: McNemar's test compared detection rates; paired t ‐tests or Wilcoxon signed‐rank tests compared quantitative metrics; reader preferences were analyzed using Wilcoxon tests; inter‐reader agreement was assessed using weighted Cohen's κ . No multiple‐comparison correction was applied ( α = 0.05). Results: SoG‐consistent valleys were detected in 31% of profiles at 3 T and 65% at 7 T, significantly. Peak‐valley distance remained stable across field strengths (0.45 ± 0.06 depth units; p = 0.37). Mean Δ‐signal (33.5 vs. 36.1; p = 0.81) and contrast ratio (0.013 vs. 0.000; p = 0.54) did not differ significantly. Both readers demonstrated a strong preference for 7 T images (pseudo‐median +1 to +1.5; significant), with fair inter‐reader agreement ( κ = 0.36). Data Conclusion: The SoG can be visualized in vivo at both 3 and 7 T, with higher detection frequency and greater subjective conspicuity at 7 T. Quantitative laminar metrics remained stable across field strengths, suggesting that improved detectability at 7 T likely reflects enhanced spatial definition rather than measurable changes in signal contrast. Level of Evidence: 2. Technical Efficacy: Stage 2.
- 30 March 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (1) , 201-208
Comparison of Myeloarchitectonic Feature Recognition of the Primary Visual Cortex at 7 T Relative to 3 T MRI
Background: The stria of Gennari (SoG) is a densely myelinated band within layer IVb of the primary visual cortex (V1) and represents the only cortical laminar structure visible macroscopically in vivo. Ultrahigh‐field MRI may improve its detection and conspicuity. Purpose: To quantitatively and qualitatively compare the in vivo appearance of the SoG at 3 versus 7 T using matched high‐resolution T 2 ‐weighted fast spin‐echo MRI. Study Type: Prospective. Population: A total of 12 subjects (6 female, 6 male; median age, 17 years; range, 15–24 years) with pediatric‐onset epilepsy. Field Strength/Sequence: 3 and 7 T MRI, T 2 ‐weighted fast spin‐echo, acquired within 1 month of each other. Assessment: Cortical line profiles per subject were extracted orthogonally to the calcarine sulcus in V1. Quantitative metrics included peak‐valley distance, Δ‐signal (peak‐valley difference), and contrast ratio (CR). Two blinded neuroradiologists and a radiologist independently rated SoG conspicuity using a 5‐point Likert scale. Statistical Tests: McNemar's test compared detection rates; paired t ‐tests or Wilcoxon signed‐rank tests compared quantitative metrics; reader preferences were analyzed using Wilcoxon tests; inter‐reader agreement was assessed using weighted Cohen's κ . No multiple‐comparison correction was applied ( α = 0.05). Results: SoG‐consistent valleys were detected in 31% of profiles at 3 T and 65% at 7 T, significantly. Peak‐valley distance remained stable across field strengths (0.45 ± 0.06 depth units; p = 0.37). Mean Δ‐signal (33.5 vs. 36.1; p = 0.81) and contrast ratio (0.013 vs. 0.000; p = 0.54) did not differ significantly. Both readers demonstrated a strong preference for 7 T images (pseudo‐median +1 to +1.5; significant), with fair inter‐reader agreement ( κ = 0.36). Data Conclusion: The SoG can be visualized in vivo at both 3 and 7 T, with higher detection frequency and greater subjective conspicuity at 7 T. Quantitative laminar metrics remained stable across field strengths, suggesting that improved detectability at 7 T likely reflects enhanced spatial definition rather than measurable changes in signal contrast. Level of Evidence: 2. Technical Efficacy: Stage 2.
- 17 March 2026
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (5) , 1120-1129
Super-resolution MRI–derived brainstem and cerebellar volumes in fetuses between 22 weeks and 32 weeks of gestation
Background The posterior fossa undergoes rapid development in utero, yet normative volumetric data are limited, especially during mid-gestation when most fetal MRIs are performed. Objective This study aimed to develop a segmentation method tailored to the fetal posterior fossa and establish normative growth trajectories for key infratentorial structures between 22 weeks and 32 weeks of gestation. Materials and methods Eighty-five pregnant women were prospectively recruited at a single institution. Inclusion criteria were normal singleton pregnancies between 19-40 weeks’ gestation and maternal age 18-45 years. Exclusion criteria included fetal abnormalities, MRI contraindications, or significant maternal comorbidities. Eighteen fetuses were excluded, resulting in 67 normal fetuses (43 male, 24 female). Imaging was performed at 3 T using multiplanar T2-weighted sequences, reconstructed into isotropic volumes after motion correction and brain extraction. Segmentation labels were created using age-specific atlases from the Developing Human Connectome Project. Expert annotations defined the midbrain, pons, medulla, vermis, and cerebellar hemispheres. Images were registered to the atlases using the Symmetric Normalization (SyN) algorithm, with labels manually verified by a pediatric neuroradiologist. Volumes were normalized to total brain volume and analyzed using linear regression with gestational age and sex as predictors. Results Absolute volumes of all posterior fossa structures significantly increased with gestational age (PR2=0.80-0.87). The cerebellum exhibited the steepest growth (β=1,056.01, R2=0.87, Pβ=0.007, Pβ=-0.43, P=0.04), despite larger absolute posterior fossa volumes overall. Conclusions This study provides normative volumetric references for fetal posterior fossa structures between 22-32 weeks’ gestation using a novel segmentation method. Absolute growth followed linear patterns, while relative measures revealed sex-specific variations in the vermis and cerebellum. These benchmarks may enhance diagnostic accuracy for detecting posterior fossa anomalies in clinical fetal MRI. Graphical abstract
- 17 March 2026
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (5) , 1120-1129
Super-resolution MRI–derived brainstem and cerebellar volumes in fetuses between 22 weeks and 32 weeks of gestation
Background The posterior fossa undergoes rapid development in utero, yet normative volumetric data are limited, especially during mid-gestation when most fetal MRIs are performed. Objective This study aimed to develop a segmentation method tailored to the fetal posterior fossa and establish normative growth trajectories for key infratentorial structures between 22 weeks and 32 weeks of gestation. Materials and methods Eighty-five pregnant women were prospectively recruited at a single institution. Inclusion criteria were normal singleton pregnancies between 19-40 weeks’ gestation and maternal age 18-45 years. Exclusion criteria included fetal abnormalities, MRI contraindications, or significant maternal comorbidities. Eighteen fetuses were excluded, resulting in 67 normal fetuses (43 male, 24 female). Imaging was performed at 3 T using multiplanar T2-weighted sequences, reconstructed into isotropic volumes after motion correction and brain extraction. Segmentation labels were created using age-specific atlases from the Developing Human Connectome Project. Expert annotations defined the midbrain, pons, medulla, vermis, and cerebellar hemispheres. Images were registered to the atlases using the Symmetric Normalization (SyN) algorithm, with labels manually verified by a pediatric neuroradiologist. Volumes were normalized to total brain volume and analyzed using linear regression with gestational age and sex as predictors. Results Absolute volumes of all posterior fossa structures significantly increased with gestational age (PR2=0.80-0.87). The cerebellum exhibited the steepest growth (β=1,056.01, R2=0.87, Pβ=0.007, Pβ=-0.43, P=0.04), despite larger absolute posterior fossa volumes overall. Conclusions This study provides normative volumetric references for fetal posterior fossa structures between 22-32 weeks’ gestation using a novel segmentation method. Absolute growth followed linear patterns, while relative measures revealed sex-specific variations in the vermis and cerebellum. These benchmarks may enhance diagnostic accuracy for detecting posterior fossa anomalies in clinical fetal MRI. Graphical abstract
- 23 January 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2527-2537
Fast, Robust T2 ‐ IVIM Quantitative MRI With Distortion and Motion‐Corrected Multi‐Echo EPI
Purpose: To enable robust, motion‐ and distortion‐corrected T2‐IVIM parameter estimation within clinically feasible scan times. Methods: A single‐shot, multi‐echo spin‐echo EPI sequence was used to acquire abdominal diffusion‐weighted MRI with time‐efficient sampling of b‐value and TE pairs. The multi‐echo acquisition enabled distortion correction using reverse phase‐encoding between echoes. Motion and distortion correction were applied before fitting a joint T2‐IVIM model across the b‐value and TE dimensions to obtain TE‐independent IVIM parameters and compartment‐specific T2 estimates. For comparison, a previously established single‐echo T2‐IVIM protocol with longer scan times and a single‐echo protocol matched to the multi‐echo parameters were acquired. Uncertainty was evaluated with wild bootstrap error analysis. Results: The multi‐echo approach enabled motion‐ and distortion‐corrected T2‐IVIM mapping in under 5 min, compared with 11–13 min for the prior minimal single‐echo protocol or nearly 19 min when acquired as separate shots. The liver was selected as the target organ due to its marked sensitivity to effects in standard IVIM. Error analysis showed comparable per‐voxel uncertainty between the multi‐echo method and the minimal single‐echo protocol. Conclusion: The combination of multi‐echo sequence design and artifact correction enabled stable fitting of the extended T2‐IVIM model with improved liver coverage and less than half the scan time of prior protocols. These advances support broader clinical applicability of T2‐IVIM imaging by reducing acquisition burden while enhancing artifact correction and parameter robustness.
- 23 January 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2527-2537
Fast, Robust T2 ‐ IVIM Quantitative MRI With Distortion and Motion‐Corrected Multi‐Echo EPI
Purpose: To enable robust, motion‐ and distortion‐corrected T2‐IVIM parameter estimation within clinically feasible scan times. Methods: A single‐shot, multi‐echo spin‐echo EPI sequence was used to acquire abdominal diffusion‐weighted MRI with time‐efficient sampling of b‐value and TE pairs. The multi‐echo acquisition enabled distortion correction using reverse phase‐encoding between echoes. Motion and distortion correction were applied before fitting a joint T2‐IVIM model across the b‐value and TE dimensions to obtain TE‐independent IVIM parameters and compartment‐specific T2 estimates. For comparison, a previously established single‐echo T2‐IVIM protocol with longer scan times and a single‐echo protocol matched to the multi‐echo parameters were acquired. Uncertainty was evaluated with wild bootstrap error analysis. Results: The multi‐echo approach enabled motion‐ and distortion‐corrected T2‐IVIM mapping in under 5 min, compared with 11–13 min for the prior minimal single‐echo protocol or nearly 19 min when acquired as separate shots. The liver was selected as the target organ due to its marked sensitivity to effects in standard IVIM. Error analysis showed comparable per‐voxel uncertainty between the multi‐echo method and the minimal single‐echo protocol. Conclusion: The combination of multi‐echo sequence design and artifact correction enabled stable fitting of the extended T2‐IVIM model with improved liver coverage and less than half the scan time of prior protocols. These advances support broader clinical applicability of T2‐IVIM imaging by reducing acquisition burden while enhancing artifact correction and parameter robustness.
- 13 September 2025
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 125, 102643
A self-attention model for robust rigid slice-to-volume registration of functional MRI
- 13 September 2025
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 125, 102643
A self-attention model for robust rigid slice-to-volume registration of functional MRI
- 12 August 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (9) , e70117
Improved IVIM Imaging in Adolescent Crohn's Disease Using Dual‐Echo EPI Distortion and Motion Correction
Diffusion‐weighted imaging (DWI) during MR enterography helps identify bowel inflammation in Crohn's disease (CD). However, image quality is compromised by geometric distortions from B0 field variations and physiological motion, making it challenging for radiologists to correlate findings between DWI and structural images. Traditional correction methods using reversed polarity scans are ineffective due to motion between acquisitions, which limits accurate estimation of intravoxel incoherent motion (IVIM) parameters. We propose a dual‐echo echo‐planar imaging (EPI) method that retrospectively corrects both geometric distortions and motion in 3T bowel DWI by accounting for field changes during peristalsis and breathing. We added a 5‐ to 7‐min dual‐echo EPI DW sequence (eight b‐values, six directions) to the clinical MR enterography protocol of 21 patients with suspected CD at 3T MRI. Distortion correction was applied based on dynamically estimated fields from dual‐echo DWI, followed by intra‐volume registration between odd–even slices and inter‐volume registration for motion correction. Two experienced board‐certified radiologists evaluated the severity of the disease using simplified magnetic resonance index of activity (MaRIA) scores. Based on their consensus scores, patients were categorized into three groups: no active disease (MaRIA score = 0), active disease (MaRIA score = 1–2), and severe disease (MaRIA score = 3–5). The proposed DWI correction pipeline improved DWI/T2‐weighted image Dice similarity from 0.73 to 0.89, enabling better correlation of findings between structural and DW‐MR images and enhancing DWI's clinical value. Corrected IVIM parameters showed stronger correlations with MaRIA scores (D: ρ = −0.93; f: ρ = −0.94, p < 0.001) compared to uncorrected parameters (D: ρ = −0.68, p = 0.001; f: ρ = −0.35, p = 0.118). Diagnostic sensitivity increased from 0.44 to 0.89, while parameter uncertainty decreased from 35.58% to 19.31% for D and 63.48% to 40.40% for f (p < 0.001). These improvements strengthen quantitative IVIM imaging for CD assessment, potentially reducing reliance on contrast imaging while offering enhanced tissue perfusion and diffusion insights.
- 12 August 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (9) , e70117
Improved IVIM Imaging in Adolescent Crohn's Disease Using Dual‐Echo EPI Distortion and Motion Correction
Diffusion‐weighted imaging (DWI) during MR enterography helps identify bowel inflammation in Crohn's disease (CD). However, image quality is compromised by geometric distortions from B0 field variations and physiological motion, making it challenging for radiologists to correlate findings between DWI and structural images. Traditional correction methods using reversed polarity scans are ineffective due to motion between acquisitions, which limits accurate estimation of intravoxel incoherent motion (IVIM) parameters. We propose a dual‐echo echo‐planar imaging (EPI) method that retrospectively corrects both geometric distortions and motion in 3T bowel DWI by accounting for field changes during peristalsis and breathing. We added a 5‐ to 7‐min dual‐echo EPI DW sequence (eight b‐values, six directions) to the clinical MR enterography protocol of 21 patients with suspected CD at 3T MRI. Distortion correction was applied based on dynamically estimated fields from dual‐echo DWI, followed by intra‐volume registration between odd–even slices and inter‐volume registration for motion correction. Two experienced board‐certified radiologists evaluated the severity of the disease using simplified magnetic resonance index of activity (MaRIA) scores. Based on their consensus scores, patients were categorized into three groups: no active disease (MaRIA score = 0), active disease (MaRIA score = 1–2), and severe disease (MaRIA score = 3–5). The proposed DWI correction pipeline improved DWI/T2‐weighted image Dice similarity from 0.73 to 0.89, enabling better correlation of findings between structural and DW‐MR images and enhancing DWI's clinical value. Corrected IVIM parameters showed stronger correlations with MaRIA scores (D: ρ = −0.93; f: ρ = −0.94, p < 0.001) compared to uncorrected parameters (D: ρ = −0.68, p = 0.001; f: ρ = −0.35, p = 0.118). Diagnostic sensitivity increased from 0.44 to 0.89, while parameter uncertainty decreased from 35.58% to 19.31% for D and 63.48% to 40.40% for f (p < 0.001). These improvements strengthen quantitative IVIM imaging for CD assessment, potentially reducing reliance on contrast imaging while offering enhanced tissue perfusion and diffusion insights.
- 1 July 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (1) , 262-268
7T TOF-MRA in Adolescents
The increased signal-to-noise ratio (SNR) at 7 Tesla (7T) enables higher spatial resolution for neurovascular imaging, yet its application in pediatric magnetic resonance angiography (MRA) remains underexplored. This study systematically evaluates the advantages of 7T time-of-flight (TOF) MRA compared to 3T in pediatric patients, hypothesizing that 7T would provide superior vessel contrast and increased vascular volume, given the use of smaller voxels, as well as higher SNR, despite these smaller voxels. This HIPAA-compliant, IRB-approved retrospective study included pediatric patients (<19 years) who underwent 7T TOF MRA. Controls consisted of either same-subject 3T MRAs within 6 months (when available) or age-and sex-matched 3T MRA subjects. Imaging parameters were optimized for spatial resolution at 7T to achieve 0.3-0.4 mm isotropic voxels. Quantitative analysis included contrast ratio (CR) and SNR measurements for the ICA, M1 to M4 arterial segments, and lenticulostriate perforating arteries. Vascular volume was assessed using 3D segmentation. Semiquantitative vessel conspicuity ratings and motion artifact scoring were performed by blinded neuroradiologists. Fifteen patients (10 with 7T MRA, 5 with matched 3T controls) and 20 MRAs were analyzed. CR was significantly higher at 7T for perforators, M3, and M4 branches (P < 0.05), with the greatest improvement in M4 branches. Vascular volume was 147% greater at 7T (P = 0.018), reflecting improved small vessel depiction and segmentation. Semiquantitative analysis showed significantly better vessel conspicuity at 7T for M4 branches and lenticulostriate perforators (P < 0.01). Motion artifact scores were similar between field strengths (P = 0.118). 7T TOF MRA significantly enhances vascular contrast and improves visualization of small arteries compared to 3T, making it a valuable tool for pediatric cerebrovascular imaging. CR= Contrast Ratio; LSA= Lenticulostriate Perforating Arteries.
- 1 July 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (1) , 262-268
7T TOF-MRA in Adolescents
The increased signal-to-noise ratio (SNR) at 7 Tesla (7T) enables higher spatial resolution for neurovascular imaging, yet its application in pediatric magnetic resonance angiography (MRA) remains underexplored. This study systematically evaluates the advantages of 7T time-of-flight (TOF) MRA compared to 3T in pediatric patients, hypothesizing that 7T would provide superior vessel contrast and increased vascular volume, given the use of smaller voxels, as well as higher SNR, despite these smaller voxels. This HIPAA-compliant, IRB-approved retrospective study included pediatric patients (<19 years) who underwent 7T TOF MRA. Controls consisted of either same-subject 3T MRAs within 6 months (when available) or age-and sex-matched 3T MRA subjects. Imaging parameters were optimized for spatial resolution at 7T to achieve 0.3-0.4 mm isotropic voxels. Quantitative analysis included contrast ratio (CR) and SNR measurements for the ICA, M1 to M4 arterial segments, and lenticulostriate perforating arteries. Vascular volume was assessed using 3D segmentation. Semiquantitative vessel conspicuity ratings and motion artifact scoring were performed by blinded neuroradiologists. Fifteen patients (10 with 7T MRA, 5 with matched 3T controls) and 20 MRAs were analyzed. CR was significantly higher at 7T for perforators, M3, and M4 branches (P < 0.05), with the greatest improvement in M4 branches. Vascular volume was 147% greater at 7T (P = 0.018), reflecting improved small vessel depiction and segmentation. Semiquantitative analysis showed significantly better vessel conspicuity at 7T for M4 branches and lenticulostriate perforators (P < 0.01). Motion artifact scores were similar between field strengths (P = 0.118). 7T TOF MRA significantly enhances vascular contrast and improves visualization of small arteries compared to 3T, making it a valuable tool for pediatric cerebrovascular imaging. CR= Contrast Ratio; LSA= Lenticulostriate Perforating Arteries.
- 18 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1913-1929
Rapid, high‐resolution and distortion‐free R2∗ mapping of fetal brain using multi‐echo radial FLASH and model‐based reconstruction
Purpose: To develop a rapid, high‐resolution, and distortion‐free technique for simultaneous water‐fat separation, and mapping of the fetal brain at 3 T.Methods: A 2D multi‐echo radial FLASH sequence with blip gradients is adapted for data acquisition during maternal free breathing. A calibrationless model‐based reconstruction with sparsity constraints is developed to jointly estimate water, fat, and field maps directly from k‐space. This approach was validated and compared to reference methods using numerical and NIST phantoms and data from nine fetuses between 26 and 36 weeks of gestation age.Results: Both numerical and experimental phantom studies confirm good accuracy and precision. In fetal studies, model‐based reconstruction yields quantitative values in close agreement with those from a parallel imaging compressed sensing (PICS) technique using Graph Cut (intra‐class correlation coefficient [ICC] = 0.9601), while providing enhanced image detail. Repeated scans confirm good reproducibility (ICC = 0.9213). Compared to multi‐echo EPI, the proposed radial technique produces higher‐resolution (1.1 1.1 3 mm vs. 2–3 2–3 3 mm) maps with reduced distortion. Despite differences in motion, resolution, and distortion, values are comparable between the two acquisition strategies (ICC = 0.8049). Additionally, the proposed approach enables the synthesis of high‐resolution and distortion‐free ‐weighted images.Conclusion: This study demonstrates the feasibility of using multi‐echo radial FLASH combined with calibrationless model‐based reconstruction for motion‐robust, distortion‐free mapping of the fetal brain at 3T, achieving a nominal resolution of mm within 2 s per slice.
- 18 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1913-1929
Rapid, high‐resolution and distortion‐free R2∗ mapping of fetal brain using multi‐echo radial FLASH and model‐based reconstruction
Purpose: To develop a rapid, high‐resolution, and distortion‐free technique for simultaneous water‐fat separation, and mapping of the fetal brain at 3 T.Methods: A 2D multi‐echo radial FLASH sequence with blip gradients is adapted for data acquisition during maternal free breathing. A calibrationless model‐based reconstruction with sparsity constraints is developed to jointly estimate water, fat, and field maps directly from k‐space. This approach was validated and compared to reference methods using numerical and NIST phantoms and data from nine fetuses between 26 and 36 weeks of gestation age.Results: Both numerical and experimental phantom studies confirm good accuracy and precision. In fetal studies, model‐based reconstruction yields quantitative values in close agreement with those from a parallel imaging compressed sensing (PICS) technique using Graph Cut (intra‐class correlation coefficient [ICC] = 0.9601), while providing enhanced image detail. Repeated scans confirm good reproducibility (ICC = 0.9213). Compared to multi‐echo EPI, the proposed radial technique produces higher‐resolution (1.1 1.1 3 mm vs. 2–3 2–3 3 mm) maps with reduced distortion. Despite differences in motion, resolution, and distortion, values are comparable between the two acquisition strategies (ICC = 0.8049). Additionally, the proposed approach enables the synthesis of high‐resolution and distortion‐free ‐weighted images.Conclusion: This study demonstrates the feasibility of using multi‐echo radial FLASH combined with calibrationless model‐based reconstruction for motion‐robust, distortion‐free mapping of the fetal brain at 3T, achieving a nominal resolution of mm within 2 s per slice.
- 26 May 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (3) , 937-948
Vendor‐agnostic 3D multiparametric relaxometry improves cross‐platform reproducibility
Purpose: To address the unmet need for a cross‐platform, multiparametric relaxometry technique to facilitate data harmonization across different sites.Methods: A simultaneous T1 and T2 mapping technique, 3D quantification using an interleaved Look–Locker acquisition sequence with a T2 preparation pulse (3D‐QALAS), was implemented using the open‐source vendor‐agnostic Pulseq platform. The technique was tested on four 3 T scanners from two vendors across two sites, evaluating cross‐scanner, cross‐software version, cross‐site, and cross‐vendor variability. The cross‐vendor reproducibility was assessed using both the vendor‐native and Pulseq‐based implementations. A National Institute of Standards and Technology/International Society for Magnetic Resonance in Medicine system phantom and three human subjects were evaluated. The acquired T1 and T2 maps from the different 3D‐QALAS runs were compared using linear regression, Bland–Altman plots, coefficient of variation (CV), and intraclass correlation coefficient (ICC).Results: Pulseq‐QALAS demonstrated high linearity (R2 = 0.994 for T1, R2 = 0.999 for T2) and correlation (ICC = 0.99 [0.98–0.99]) against temperature‐corrected NMR reference values in the system phantom. Compared to vendor‐native sequences, the Pulseq implementation showed significantly higher reproducibility in phantom T2 values (CV, 2.3% vs. 17%; p < 0.001), and improved T1 reproducibility (CV, 3.4% vs. 4.9%; p = 0.71, not significant). The Pulseq implementation reduced cross‐vendor variability to a level comparable to cross‐scanner (within‐vendor) variability. In vivo, Pulseq‐QALAS exhibited reduced cross‐vendor variability, particularly for T2 values in gray matter with a twofold reduction in variability (CV, 2.3 vs. 5.9%; p < 0.001).Conclusion: An identical implementation across different scanners and vendors, combined with consistent reconstruction and fitting pipelines, can improve relaxometry measurement reproducibility across platforms.
- 26 May 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (3) , 937-948
Vendor‐agnostic 3D multiparametric relaxometry improves cross‐platform reproducibility
Purpose: To address the unmet need for a cross‐platform, multiparametric relaxometry technique to facilitate data harmonization across different sites.Methods: A simultaneous T1 and T2 mapping technique, 3D quantification using an interleaved Look–Locker acquisition sequence with a T2 preparation pulse (3D‐QALAS), was implemented using the open‐source vendor‐agnostic Pulseq platform. The technique was tested on four 3 T scanners from two vendors across two sites, evaluating cross‐scanner, cross‐software version, cross‐site, and cross‐vendor variability. The cross‐vendor reproducibility was assessed using both the vendor‐native and Pulseq‐based implementations. A National Institute of Standards and Technology/International Society for Magnetic Resonance in Medicine system phantom and three human subjects were evaluated. The acquired T1 and T2 maps from the different 3D‐QALAS runs were compared using linear regression, Bland–Altman plots, coefficient of variation (CV), and intraclass correlation coefficient (ICC).Results: Pulseq‐QALAS demonstrated high linearity (R2 = 0.994 for T1, R2 = 0.999 for T2) and correlation (ICC = 0.99 [0.98–0.99]) against temperature‐corrected NMR reference values in the system phantom. Compared to vendor‐native sequences, the Pulseq implementation showed significantly higher reproducibility in phantom T2 values (CV, 2.3% vs. 17%; p < 0.001), and improved T1 reproducibility (CV, 3.4% vs. 4.9%; p = 0.71, not significant). The Pulseq implementation reduced cross‐vendor variability to a level comparable to cross‐scanner (within‐vendor) variability. In vivo, Pulseq‐QALAS exhibited reduced cross‐vendor variability, particularly for T2 values in gray matter with a twofold reduction in variability (CV, 2.3 vs. 5.9%; p < 0.001).Conclusion: An identical implementation across different scanners and vendors, combined with consistent reconstruction and fitting pipelines, can improve relaxometry measurement reproducibility across platforms.