NLNathaniel C. Lawson

Nathaniel C. Lawson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nathaniel C. Lawson has a total of 156 co-authors. Here are the top co-authors by number of shared publications:

  • John O. Burgess

    Department of Clinical and Community Sciences, School of Dentistry University of Alabama at Birmingham Birmingham AL

    16 shared publications
  • Amir H. Nejat

    Associate Professor, Division of Prosthodontics, Louisiana State University School of Dentistry, New Orleans, LA

    6 shared publications
  • Amir Hossein Nejat

    Division of Prosthodontics Louisiana State University School of Dentistry New Orleans Louisiana USA

    5 shared publications
  • Chee Paul Lin

    Center for Clinical and Translational Science Birmingham AL

    5 shared publications
  • John O Burgess

    University of Alabama at Birmingham School of Dentistry, Clinical and Community Sciences, Department of Biomaterials, 1919 7th Avenue South, Birmingham, AL 35205

    5 shared publications
  • Edwin Kee

    Assistant Professor, Division of Prosthodontics Louisiana State University School of Dentistry New Orleans Louisiana USA

    4 shared publications

Latest Publications

  • Comparison of mechanical and optical properties of 3D printed denture bases

    by Ting-Chia Liu, Pouya Sabanik, Nitish Surathu, Neeraj Surathu, Nathaniel C. Lawson

  • Effect of post‐print cleaning protocol on mechanical, optical, and conversion characteristics of two 3D‐printed resin composites for definitive crowns

    by Ting‐Chia Liu, Princy Thakkar, Zachary G. Cuny, Nathaniel C. Lawson, Neeraj Surathu, Amir H. Nejat

    Purpose: To evaluate the influence of post‐print cleaning protocols on the biaxial flexural strength, degree of conversion, and translucency of two 3D‐printed definitive crown materials with differing filler content. Materials and methods: Lower‐filled (Detax Crown; 24.4 wt% filler) and higher‐filled (Rodin Sculpture 2.0; 60.2 wt% filler) 3D‐printed crown materials were subjected to five cleaning conditions: isopropyl alcohol for 5 s (IPA‐5s) or 60 s (IPA‐60s), Rodin Universal Resin Cleaner, Harvest InovaPrint Wash, or Saremco Print Cleaning Concentrate. Biaxial flexural strength (ISO 4049:2019), degree of conversion, and translucency were measured, and surface morphology was assessed by scanning electron microscopy (SEM). Two‐way ANOVA with Bonferroni adjustment and Spearman correlations were applied ( α = 0.05). Results: IPA‐5s produced the numerically highest flexural strength in both materials, significantly so only for Sculpture 2.0, whereas Harvest and Saremco produced the lowest, and Rodin intermediate. IPA‐60s reduced the strength for Sculpture 2.0 ( p < 0.001) but not for Detax Crown ( p = 0.539). Sculpture 2.0 showed significant translucency reductions with all conditions except IPA‐5s, whereas Detax Crown translucency remained stable. IPA‐5s also produced the highest degree of conversion for both materials, with an exploratory correlation between mean flexural strength and mean degree of conversion across protocols ( n = 5 group means per material), reaching significance only for Detax Crown ( r s = 0.900, p = 0.037). SEM showed well‐embedded filler in Detax Crown across conditions, whereas Sculpture 2.0 showed greater filler exposure variability. Conclusion: All alternative cleaning protocols reduced flexural strength and degree of conversion in both materials, but the optical response was material‐specific. Translucency varied only slightly in the lower filled material, whereas the higher filled material showed marked translucency loss with every protocol other than a 5‐s IPA wash. Extending IPA exposure from 5 to 60 s reduced strength, degree of conversion, and translucency in the higher filled material but not the lower filled material. Strength loss was accompanied by reduced degree of conversion in the lower filled material and, in the higher filled material, additionally by opacification and greater filler exposure on SEM.

  • Fatigue Survival of Lithium Disilicate, 3D ‐Printed Composite, and Injection‐Molded Direct Composite Veneers

    by Silvia Rojas‐Rueda, Augusto A. Robles, Emerson Martins, Mohamed Hammamy, Nathaniel C. Lawson

    Objectives: To evaluate and compare the fatigue performance of veneers fabricated from lithium disilicate, 3D‐printed resin composite, and injection‐molded direct resin composite under standardized cyclic loading. Materials and Methods: Thirty extracted human maxillary central incisors ( n = 10 per group) received standardized veneer preparations. Veneers were fabricated using CAD/CAM milling (lithium disilicate), additive manufacturing (3D‐printed resin composite), or injection molding (direct composite). Specimens were adhesively bonded following manufacturer protocols, thermocycled (10,000 cycles) and subjected to cyclic fatigue loading (200 N, 1.6 Hz) for up to 1,000,000 cycles. Fatigue survival was analyzed using Kaplan–Meier and log‐rank tests. Results: Significant differences in survival distributions were observed ( p < 0.001). Lithium disilicate showed the highest fatigue performance, with 80% survival at 1,000,000 cycles and a mean survival of 954,060 cycles. 3D‐printed resin composite showed the lowest survival (mean: 134,878 cycles), while direct resin composite exhibited intermediate performance (mean: 460,453 cycles). Failure modes varied by material, with lithium disilicate demonstrating debonding, 3D‐printed resin presenting multiple failure types, and direct composite limited to incisal fractures. Conclusions: Lithium disilicate demonstrated superior fatigue performance compared with resin‐based materials. Injection molded direct composite performed better than 3D‐printed resin composite with more repairable fractures. Clinical Significance: Although lithium disilicate restorations remain the most durable material choice for anterior veneers, injection molded direct composites offer an economical option with possibly repairable fractures.


  • Open Access

    Impact of Printing Orientation and Printer Type on the Accuracy of 3D-Printed Dental Splints

    by Mohammed Hammamy, Neeraj Surathu, Nitish Surathu, Nathaniel C. Lawson, Andrea C. Dardashtian

    Additive manufacturing has expanded the fabrication of occlusal splints; however, the influence of printing technology and build orientation on accuracy remains unclear. This study evaluated the effect of printing technology (Liquid Crystal Display [LCD] and Digital Light Processing [DLP]) and build orientation (0°, 45°, and 90°) on the trueness of additively manufactured occlusal splints under standardized conditions. A maxillary occlusal splint was digitally designed from a scanned typodont and used as the reference model. Specimens (n = 10/group) were fabricated using two LCD printers (Ackuretta SOL, Phrozen Mini 8K S) and one DLP printer (SprintRay Pro 95S) with a single photopolymer resin (KeySplint Soft). All samples were printed at 100 µm layer thickness and subjected to standardized post-processing. Trueness was assessed by comparing scanned splints to the reference STL using Geomagic Control X and expressed as root mean square (RMS) values. Data were analyzed using two-way ANOVA and Tukey post hoc tests (α = 0.05). Printing technology and build orientation significantly affected trueness (p < 0.001), with RMS values increasing as build orientation increased, and no significant interaction between factors (p > 0.05). LCD systems demonstrated lower RMS values than the DLP system across all orientations. Within the limitations of this study, both factors influenced trueness; however, all systems produced clinically comparable results, supporting the use of LCD technology as a cost-effective option for occlusal splint fabrication.

  • Open Access

    Toothbrush Resistance of Resin-Based Stain and Glaze Materials Applied to 3D-Printed Denture Resins

    by Panisa Homyai, Ting-Chia Liu, Princy Thakkar, Chin-Chuan Fu, Nathaniel C. Lawson, Rama Kiran Chavali

    Three-dimensional (3D)-printed dentures are often fabricated from a single tooth-colored resin and externally characterized using stains and glaze coatings to enhance gingival esthetics and surface properties. However, routine toothbrushing may degrade these coatings, potentially affecting surface gloss and roughness. This study evaluated the effects of stain timing and glaze application on the gloss and surface roughness of a 3D-printed denture resin following simulated toothbrushing. Eighty disc-shaped specimens (12 mm × 3 mm) were fabricated and assigned to two staining systems (OPTIGLAZE Color and Palette 2.0), with subgroups based on stain timing (before or after post-curing) and glaze application (with or without glaze) (n = 10). Specimens underwent 20,000 cycles of simulated toothbrushing, and gloss and surface roughness were measured before and after brushing. Data were analyzed using two-way ANOVA (α = 0.05). Glaze application significantly improved gloss retention for both staining systems (p < 0.001), while stain timing had no independent effect. Glaze application with Palette 2.0 demonstrated improved gloss retention when post-cured in a post-curing unit. Toothbrushing increased surface roughness in all groups, with no significant effects of stain timing or glaze. Within the limitations of this study, glaze improves gloss stability, whereas stain timing has minimal influence and does not affect surface roughness.

  • Top Cited Papers
    Open Access

    A Review of Current Systems, Materials, and Protocols for 3D ‐Printed Splints, Crowns, and Dentures

    by Pouya Sabanik, Ting‐Chia Liu, Mahmoudreza Tabatabaeian, Mateus G. Rocha, Neeraj Surathu, Nathaniel C. Lawson

    Objectives: To summarize and synthesize evidence‐based conclusions on optimal three‐dimensional (3D) printing technologies, materials, and clinical protocols for splints, crowns, and dentures. Overview: In resin vat printing, stereolithography (SLA) offers superior surface finish, while liquid crystal display (LCD) and digital light processing (DLP) excel in speed for larger prints, with LCD providing a cost advantage. Ceramic vat printing yields clinically acceptable strength but is equipment‐ and time‐intensive. Optimal angulation varies by application: splints (0°), crowns (150°–210°), dentures (45°–90°). A 50 μm layer height is preferred for most restorations, with dentures tolerating 100 μm. Commonly used resins employ low‐viscosity monomers (e.g., ethoxylated bisphenol A dimethacrylate [Bis‐EMA]) that limit stiffness and fast photoinitiators (e.g., ethyl (2,4,6‐trimethylbenzoyl) phenylphosphinate [TPO]), requiring 385–405 nm curing. Conclusions: Flexible splints excel in fracture toughness and impact strength; firm splints match milled wear performance. Printed crowns, while weaker than milled options, offer toughness; wear rates remain a concern. Printed denture bases vary in strength but can match or exceed conventional options; printed teeth show favorable wear resistance. Postprocessing, polishing, and bonding protocols critically influence outcomes. Clinical Significance: Employing validated printing parameters, selecting the appropriate resin, and following evidence‐based protocols allows clinicians to maximize restoration accuracy and mechanical performance while leveraging 3D printing's efficiency and cost benefits.


  • Open Access

    Roughness and Gloss of 3D-Printed Crowns Following Polishing or Varnish Application

    by Silvia Rojas-Rueda, Tariq Aziz Alsahafi, Mohammed Hammamy, Neeraj Surathu, Nitish Surathu, Nathaniel C. Lawson, Taiseer A. Sulaiman

    The aim of this study was to evaluate and compare the surface roughness and gloss—both initially and after simulated toothbrushing—of three 3D-printed crown materials subjected to different surface treatments: varnishing, polishing with diamond-impregnated rubber polishers, and polishing with a bristle brush and paste. Disc-shaped specimens (n = 90) were 3D-printed using three commercially available crown resins (Rodin Sculpture, VarseoSmile TriniQ, and OnX Tough 2) and post-processed per manufacturers’ instructions. Specimens were divided into three surface treatment groups: application of a light-cured varnish, polishing with a two-step diamond-impregnated rubber polisher, or polishing with a bristle brush and abrasive paste. Surface roughness and gloss were measured after treatment and again following 20,000 cycles of simulated toothbrushing. Additional specimens were prepared for Vickers microhardness testing and determination of filler weight percentage (wt%). Statistical comparisons were performed using two-way ANOVA with significance set at p < 0.05. Results: The varnish provided the statistically lowest roughness of all surface treatments for all materials. The bristle brush and abrasive paste polishing protocol produced the greatest gloss for the softest material (VarseoSmile TriniQ) and lowest gloss for the hardest material (Rodin Sculpture), whereas the two-step diamond-impregnated rubber polisher produced an equivalent gloss on all materials. Following toothbrushing, roughness was minimally affected; however, gloss was considerably reduced. Conclusions: All tested polishing and varnishing methods achieved clinically acceptable surface roughness (Ra < 0.2 µm) that persisted after simulated toothbrushing. Notably, the two-step diamond-impregnated rubber polisher produced consistent gloss across all materials, while the bristle brush and abrasive paste polishing protocol performed better on softer materials, and varnish application resulted in equal or superior gloss and roughness retention compared to polishing.


  • Open Access

    Compatibility of Dual-Cure Core Materials with Self-Etching Adhesives

    by Zachary K. Greene, Augusto A. Robles, Nathaniel C. Lawson

    Background/Objectives: A material incompatibility has been established between self-etching adhesives and amine-containing dual-cure resin composite materials used for core buildups. This study aims to compare the dentin bond strength of several amine-containing and amine-free core materials using self-etching adhesives with different pHs. Methods: Extracted human molars were mounted in acrylic and ground flat with 320-grit silicon carbide paper. Next, 520 specimens (n = 10/group) were assigned to a dual-cure core buildup material group (10 amine-containing, 2 amine-free, and 1 reference light-cure only bulk fill flowable composite) and assigned to a self-etching adhesive subgroup (pH levels of approximately 1.0, 3.0, and 4.0). Within 4 h of surface preparation, the adhesive corresponding to the specimen’s subgroup was applied and light-cured. Composite buttons for the assigned dual-cure core material of each group were placed using a bonding clamp apparatus, allowed to self-cure for 2 h at 37 °C, and then unclamped. An additional group with one adhesive (pH = 3.0) was prepared in which the dual-cure core materials were light-cured. The bonded specimens were stored in water at 37 °C for 24 h. The specimens were mounted on a testing clamp and de-bonded in a universal testing machine with a load applied to a circular notched-edge blade at a crosshead speed of 1 mm/min until bond failure. The maximum load divided by the area of the button was recorded as the shear bond strength. The data was analyzed via 2-way ANOVA. Results: The analysis of bond strength via 2-way ANOVA determined statistically significant differences between the adhesives, the core materials, and their interaction (p < 0.01). There was a general trend in shear bond strength for the adhesives, where pH 4.0 > 3.0 > 1.0. The amine-free core materials consistently demonstrated higher shear bond strengths as compared to the other core materials when chemically cured only. Light-curing improved bond strength for some materials with perceived incompatibility. Conclusions: The results of this study suggest that an incompatibility can exist between self-etching adhesives and dual-cure resin composite core materials. A decrease in the pH of the utilized adhesive corresponded to a decrease in the bond strength of dual-cure core materials when self-curing. This incompatibility may be minimized with the use of core materials formulated with amine-free chemistry. Alternatively, the dual-cure core materials may be light-cured.


  • Methods of evaluating mechanical properties of 3D printed occlusal device materials: Flexural strength, fracture toughness, and impact strength

    by Mohammed Hammamy, Silvia Rojas-Rueda, Amir H. Nejat, Suleiman Hamdan, Haibin Ning, Nathaniel C. Lawson