David J. Stockton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
David J. Stockton has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Gerard P. Slobogean
Department of Orthopaedic Surgery, University of California, Irvine, Irvine, CA
7 shared publications - Alice (Wei Ting) Wang
Department of Orthopaedics, University of British Columbia
3 shared publications Andrew N. Pollak
3 shared publications- Aresh Sepehri
Faculty of Medicine, Department of Orthopaedics, The University of British Columbia, Vancouver, BC, Canada; Division of Orthopaedic Trauma, Vancouver General Hospital, Vancouver Coastal Health, Vancouver, BC, Canada
3 shared publications - Darren M. Roffey
Department of Orthopaedics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
3 shared publications Gerard P. Slobogean
Department of Orthopaedics, University of Maryland School of Medicine, Baltimore, MD, USA
3 shared publications
Latest Publications
- Open Access
- 4 August 2026
- Published by Wolters Kluwer Health in OTA International
- Vol. 9 (3)
Application of a dynamic wound closure device in orthopaedic trauma patients following fasciotomy: A level-1 trauma center perspective and preliminary case series
The challenge of achieving delayed primary closure of fasciotomy wounds is well known, and multiple techniques of achieving either delayed primary closure or alternative forms of soft-tissue reconstruction have been described in the literature. However, a universally accepted consensus of the optimal management strategy has yet to be established. We describe our experience with a device designed to use the mechanical concept of dermatotraction—a surgical technique that uses the skin's natural elasticity to close wounds. This device (ABRA Surgical, Southmedic, Inc) promotes a delayed primary wound healing environment and facilitates dynamic approximation of wound edges in complex fasciotomy defects. During ward-based dynamic closure fasciotomy defects transition to a state where primary closure is safely achievable. This avoids the need for soft-tissue reconstruction which is associated with variable outcomes and cosmetic acceptance. Here, we present our surgical technique and case series using this dynamic closure device.
- 4 August 2026
- Published by Wolters Kluwer Health in OTA International
- Vol. 9 (3)
Open AccessApplication of a dynamic wound closure device in orthopaedic trauma patients following fasciotomy: A level-1 trauma center perspective and preliminary case series
The challenge of achieving delayed primary closure of fasciotomy wounds is well known, and multiple techniques of achieving either delayed primary closure or alternative forms of soft-tissue reconstruction have been described in the literature. However, a universally accepted consensus of the optimal management strategy has yet to be established. We describe our experience with a device designed to use the mechanical concept of dermatotraction—a surgical technique that uses the skin's natural elasticity to close wounds. This device (ABRA Surgical, Southmedic, Inc) promotes a delayed primary wound healing environment and facilitates dynamic approximation of wound edges in complex fasciotomy defects. During ward-based dynamic closure fasciotomy defects transition to a state where primary closure is safely achievable. This avoids the need for soft-tissue reconstruction which is associated with variable outcomes and cosmetic acceptance. Here, we present our surgical technique and case series using this dynamic closure device.
- 22 October 2025
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 107-B (SUPP_10) , 32
MALREDUCTION IS THE MOST IMPORTANT TECHNICAL FACTOR CONTRIBUTING TO NONUNION IN SUPRACONDYLAR DISTAL FEMUR FRACTURES TREATED WITH LATERAL LOCKED PLATING
Nonunion and implant failure continue to be significant issues in the operative treatment of supracondylar distal femur fractures fixed with lateral locked plates. The biomechanical evolution of implant design, application, and augmentation has outpaced our basic understanding of how to optimally use bridge fixation with a lateral locked plate for these fractures. This study aimed to identify modifiable technical factors associated with nonunion after operative treatment with lateral locked plating. We retrospectively reviewed the records from 10 Level one trauma centers. Adult patients with AO/ OTA Type 33 A and C fracture patterns treated with lateral locking plate were eligible. Patients with infection, pathologic fracture, partial articular fractures, and fixation augmented with intramedullary nail or medial plate were excluded. Previously identified non-modifiable patient and injury factors were used to stratify nonunion risk into low-, medium-, and high-risk categories. We examined a host of potentially modifiable technical factors including the amount of medial translation of the articular block, anatomic lateral distal femoral angle (aLDFA), lateral plate length, proximal screw density, and type of metal used in the plate. The primary analyis employed multivariable logistic regression to determine the association of these technical variables on the risk of nonunion. The study group (N=615) were 39% male with an average age of 61 years. Fifty-two percent were intra-articular, 23% were open, and 28% were periprosthetic fractures. Stratification on known risk factors demonstrated nonunion rates of 1.6% in the low-risk group (N=129), 4.2% in the medium-risk group (N=333), and 14% in the high-risk group (N=153). The most important technical factor associated with nonunion was varus malreduction, with an aLDFA greater than 84° associated with double the odds of nonunion in the medium and high-risk groups (OR 2.1, 95%CI 1.1–4.2, P=0.03). Malreduction by medial translation of the articular block also increased the odds of nonunion across all strata, with 30% increased odds per 4mm of medial translation (95% CI 1.0–1.6, P=0.03). Working length increased the odds of nonunion primarily in the medium-risk group, with an 18% increase in nonunion per 10mm increase in working length (95% CI 1.0–1.4, P=0.01). Proximal screw density, defined as the number fo occupied screw holes proximal to the fracture divided by the total proximal holes available, was protective against nonunion across all strata (OR 0.71, 95% CI 0.53–0.92, P=0.02). Lateral plate length and type of plate material were not associated with nonunion. Surgeons should be aware that malreduction with medial translation of the articular block or varus malalignment are both associated with increased odds of nonunion after lateral plate fixation of supracondylar distal femur fractures. Longer working lengths were also associated with nonunion, suggesting the possibility that simple bridge plating may be less likely to succeed for longer fractures.
- 22 October 2025
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 107-B (SUPP_10) , 32
MALREDUCTION IS THE MOST IMPORTANT TECHNICAL FACTOR CONTRIBUTING TO NONUNION IN SUPRACONDYLAR DISTAL FEMUR FRACTURES TREATED WITH LATERAL LOCKED PLATING
Nonunion and implant failure continue to be significant issues in the operative treatment of supracondylar distal femur fractures fixed with lateral locked plates. The biomechanical evolution of implant design, application, and augmentation has outpaced our basic understanding of how to optimally use bridge fixation with a lateral locked plate for these fractures. This study aimed to identify modifiable technical factors associated with nonunion after operative treatment with lateral locked plating. We retrospectively reviewed the records from 10 Level one trauma centers. Adult patients with AO/ OTA Type 33 A and C fracture patterns treated with lateral locking plate were eligible. Patients with infection, pathologic fracture, partial articular fractures, and fixation augmented with intramedullary nail or medial plate were excluded. Previously identified non-modifiable patient and injury factors were used to stratify nonunion risk into low-, medium-, and high-risk categories. We examined a host of potentially modifiable technical factors including the amount of medial translation of the articular block, anatomic lateral distal femoral angle (aLDFA), lateral plate length, proximal screw density, and type of metal used in the plate. The primary analyis employed multivariable logistic regression to determine the association of these technical variables on the risk of nonunion. The study group (N=615) were 39% male with an average age of 61 years. Fifty-two percent were intra-articular, 23% were open, and 28% were periprosthetic fractures. Stratification on known risk factors demonstrated nonunion rates of 1.6% in the low-risk group (N=129), 4.2% in the medium-risk group (N=333), and 14% in the high-risk group (N=153). The most important technical factor associated with nonunion was varus malreduction, with an aLDFA greater than 84° associated with double the odds of nonunion in the medium and high-risk groups (OR 2.1, 95%CI 1.1–4.2, P=0.03). Malreduction by medial translation of the articular block also increased the odds of nonunion across all strata, with 30% increased odds per 4mm of medial translation (95% CI 1.0–1.6, P=0.03). Working length increased the odds of nonunion primarily in the medium-risk group, with an 18% increase in nonunion per 10mm increase in working length (95% CI 1.0–1.4, P=0.01). Proximal screw density, defined as the number fo occupied screw holes proximal to the fracture divided by the total proximal holes available, was protective against nonunion across all strata (OR 0.71, 95% CI 0.53–0.92, P=0.02). Lateral plate length and type of plate material were not associated with nonunion. Surgeons should be aware that malreduction with medial translation of the articular block or varus malalignment are both associated with increased odds of nonunion after lateral plate fixation of supracondylar distal femur fractures. Longer working lengths were also associated with nonunion, suggesting the possibility that simple bridge plating may be less likely to succeed for longer fractures.
- Open Access
- 1 June 2025
- Published by Taylor & Francis in Orthopedic Research and Reviews
- Vol. ume 17, 257-267
Weight-Bearing Monitoring Devices in Lower Extremity Fractures: A Scoping Review
Background: Orthopaedic surgeons commonly prescribe weight-bearing parameters for their patients for a variety of reasons. Weight-bearing may be limited in order to control the healing environment, but advancing a patient’s weight-bearing status is preferably done as quickly as possible to maximize functional recovery. However, it is entirely unclear to what extent these prescriptions are followed in practice. The purpose of this scoping review is to identify and compare non-invasive devices used for the measurement of weight-bearing following lower extremity fractures. Methods: Database searches of MEDLINE, EMBASE and the Cochrane Central Register of Controlled Trials (CENTRAL) were completed to identify relevant studies. Titles were screened for relevance, and abstracts were screened against the eligibility criteria. We identified studies that investigated the use of external force, pedal pressure, or activity monitoring devices used in adults after lower extremity fractures and excluded studies involving compartment pressure measurement. Findings: Sixty-two studies met the inclusion criteria. About 39% of studies used an insole-type device, which could be worn in a shoe or integrated into a removable boot. Other device types included step count or activity monitors (52%), force plates (18%), pressure film (2%) and external pedobarography systems (27%). Interpretation: We found that different monitors offered varying types of measurements and are suitable for a variety of applications. Therefore, selecting the ideal device depends on the metric of interest. Further high-quality prospective studies utilizing device monitoring are needed to validate the theory that early weight-bearing is beneficial and safe for patients with lower extremity fractures.
- 1 June 2025
- Published by Taylor & Francis in Orthopedic Research and Reviews
- Vol. ume 17, 257-267
Open AccessWeight-Bearing Monitoring Devices in Lower Extremity Fractures: A Scoping Review
Background: Orthopaedic surgeons commonly prescribe weight-bearing parameters for their patients for a variety of reasons. Weight-bearing may be limited in order to control the healing environment, but advancing a patient’s weight-bearing status is preferably done as quickly as possible to maximize functional recovery. However, it is entirely unclear to what extent these prescriptions are followed in practice. The purpose of this scoping review is to identify and compare non-invasive devices used for the measurement of weight-bearing following lower extremity fractures. Methods: Database searches of MEDLINE, EMBASE and the Cochrane Central Register of Controlled Trials (CENTRAL) were completed to identify relevant studies. Titles were screened for relevance, and abstracts were screened against the eligibility criteria. We identified studies that investigated the use of external force, pedal pressure, or activity monitoring devices used in adults after lower extremity fractures and excluded studies involving compartment pressure measurement. Findings: Sixty-two studies met the inclusion criteria. About 39% of studies used an insole-type device, which could be worn in a shoe or integrated into a removable boot. Other device types included step count or activity monitors (52%), force plates (18%), pressure film (2%) and external pedobarography systems (27%). Interpretation: We found that different monitors offered varying types of measurements and are suitable for a variety of applications. Therefore, selecting the ideal device depends on the metric of interest. Further high-quality prospective studies utilizing device monitoring are needed to validate the theory that early weight-bearing is beneficial and safe for patients with lower extremity fractures.
- Open Access
- 8 April 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (12) , e1263-e1271
The methodology and interpretation of radiographic measures for malunion in proximal humerus fractures: a systematic review
- 8 April 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (12) , e1263-e1271
Open AccessThe methodology and interpretation of radiographic measures for malunion in proximal humerus fractures: a systematic review
- Open Access
- 21 November 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (11) , e0314307
Complex regional pain syndrome after distal radius fracture: A survey of current practices
Introduction: Complex regional pain syndrome (CRPS) is a common complication following distal radius fractures that is difficult to diagnose and can lead to permanent disability. While various proposed prophylaxis and treatment modalities exist, high-quality evidence guiding practice is limited. This survey of Orthopaedic Trauma Association (OTA) and Canadian Orthopaedic Association (COA) members was conducted with the primary aim of assessing practice patterns in distal radius fractures complicated with CRPS. Methods: An electronic survey was distributed to practicing orthopaedic surgeons in the COA and OTA. Questions assessed practice setting, preference in management of distal radius fractures and CRPS, comfort level in managing CRPS, and identification of gaps in management. Responses were anonymized and collected over 8 months. Response data was analyzed using descriptive statistics; thematic analysis was used on free text response. Results: 134 survey responses were completed. 84% of respondents felt the incidence of CRPS in distal radius fractures was 1–10%, while 15% felt it was closer to 11–20%. 24% of respondents utilized the “Budapest Criteria” to diagnose CRPS. 40% offered prophylaxis in patients felt to be at high risk of developing CRPS. 66% of surgeons felt neutral, uncomfortable, or very uncomfortable managing CRPS in distal radius fractures. When asked to consider adopting a prophylactic therapy, 38% of surgeons indicated that a therapy that reduced the absolute risk of CRPS by 6–10% would change their practice. Gaps in current practice included lack of evidence-based treatment and prevention strategies and diagnostic uncertainty. Conclusion: This study identified that amongst orthopaedic surgeons in the COA and OTA, diagnosis, treatment, and prophylaxis strategies for CRPS in distal radius fractures are heterogeneous. Surgeons are not confident in their treatment of CRPS. Future studies using rigorous research methods are warranted to improve management.
- 21 November 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (11) , e0314307
Open AccessComplex regional pain syndrome after distal radius fracture: A survey of current practices
Introduction: Complex regional pain syndrome (CRPS) is a common complication following distal radius fractures that is difficult to diagnose and can lead to permanent disability. While various proposed prophylaxis and treatment modalities exist, high-quality evidence guiding practice is limited. This survey of Orthopaedic Trauma Association (OTA) and Canadian Orthopaedic Association (COA) members was conducted with the primary aim of assessing practice patterns in distal radius fractures complicated with CRPS. Methods: An electronic survey was distributed to practicing orthopaedic surgeons in the COA and OTA. Questions assessed practice setting, preference in management of distal radius fractures and CRPS, comfort level in managing CRPS, and identification of gaps in management. Responses were anonymized and collected over 8 months. Response data was analyzed using descriptive statistics; thematic analysis was used on free text response. Results: 134 survey responses were completed. 84% of respondents felt the incidence of CRPS in distal radius fractures was 1–10%, while 15% felt it was closer to 11–20%. 24% of respondents utilized the “Budapest Criteria” to diagnose CRPS. 40% offered prophylaxis in patients felt to be at high risk of developing CRPS. 66% of surgeons felt neutral, uncomfortable, or very uncomfortable managing CRPS in distal radius fractures. When asked to consider adopting a prophylactic therapy, 38% of surgeons indicated that a therapy that reduced the absolute risk of CRPS by 6–10% would change their practice. Gaps in current practice included lack of evidence-based treatment and prevention strategies and diagnostic uncertainty. Conclusion: This study identified that amongst orthopaedic surgeons in the COA and OTA, diagnosis, treatment, and prophylaxis strategies for CRPS in distal radius fractures are heterogeneous. Surgeons are not confident in their treatment of CRPS. Future studies using rigorous research methods are warranted to improve management.
- 1 March 2024
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 12 (3)
Radiographic Union Assessment in Surgically Treated Distal Femur Fractures
Background: Distal femur fractures are known to have challenging nonunion rates. Despite various available treatment methods aimed to improve union, optimal interventions are yet to be determined. Importantly, there remains no standard agreement on what defines radiographic union. Although various proposed criteria of defining radiographic union exist in the literature, there is no clear consensus on which criteria provide the most precise measurement. The use of inconsistent measures of fracture healing between studies can be problematic and limits their generalizability. Therefore, this systematic review aims to identify how fracture union is defined based on radiographic parameters for surgically treated distal femur fractures in current literature. Methods: In accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, Medline, EMBASE, Cochrane Central Register of Controlled Trials, and Web of Science Core Collection databases were searched from inception to October 2022. Studies that addressed surgically treated distal femur fractures with reported radiographic union assessment were included. Outcomes extracted included radiographic definition of union; any testing of validity, reliability, or responsiveness; reported union rate; reported time to fracture union; and any functional outcomes correlated with radiographic union. Results: Sixty articles with 3,050 operatively treated distal femur fractures were included. Operative interventions included lateral locked plate (42 studies), intramedullary nail (15 studies), dynamic condylar screw or blade plate (7 studies), dual plate or plate and nail construct (5 studies), distal anterior-posterior/posterior-anterior screws (1 study), and external fixation with a circular frame (1 study). The range of mean follow-up time reported was 4.3 to 44 months. The most common definitions of fracture union included “bridging or callus formation across 3 of 4 cortices” in 26 (43%) studies, “bony bridging of cortices” in 21 (35%) studies, and “complete bridging of cortices” in 9 (15%) studies. Two studies included additional assessment of radiographic union using the Radiographic Union Scale in Tibial fracture (RUST) or modified Radiographic Union Scale in Tibial fracture (mRUST) scores. One study included description of validity, and the other study included reliability testing. The reported mean union rate of distal femur fractures was 89% (range 58%-100%). The mean time to fracture union was documented in 49 studies and found to be 18 weeks (range 12-36 weeks) in 2,441 cases. No studies reported correlations between functional outcomes and radiographic parameters. Conclusion: The current literature evaluating surgically treated distal femur fractures lacks consistent definition of radiographic fracture union, and the appropriate time point to make this judgement is unclear. To advance surgical optimization, it is necessary that future research uses validated, reliable, and continuous measures of radiographic bone healing and correlation with functional outcomes. Level of Evidence: Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 March 2024
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 12 (3)
Radiographic Union Assessment in Surgically Treated Distal Femur Fractures
Background: Distal femur fractures are known to have challenging nonunion rates. Despite various available treatment methods aimed to improve union, optimal interventions are yet to be determined. Importantly, there remains no standard agreement on what defines radiographic union. Although various proposed criteria of defining radiographic union exist in the literature, there is no clear consensus on which criteria provide the most precise measurement. The use of inconsistent measures of fracture healing between studies can be problematic and limits their generalizability. Therefore, this systematic review aims to identify how fracture union is defined based on radiographic parameters for surgically treated distal femur fractures in current literature. Methods: In accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, Medline, EMBASE, Cochrane Central Register of Controlled Trials, and Web of Science Core Collection databases were searched from inception to October 2022. Studies that addressed surgically treated distal femur fractures with reported radiographic union assessment were included. Outcomes extracted included radiographic definition of union; any testing of validity, reliability, or responsiveness; reported union rate; reported time to fracture union; and any functional outcomes correlated with radiographic union. Results: Sixty articles with 3,050 operatively treated distal femur fractures were included. Operative interventions included lateral locked plate (42 studies), intramedullary nail (15 studies), dynamic condylar screw or blade plate (7 studies), dual plate or plate and nail construct (5 studies), distal anterior-posterior/posterior-anterior screws (1 study), and external fixation with a circular frame (1 study). The range of mean follow-up time reported was 4.3 to 44 months. The most common definitions of fracture union included “bridging or callus formation across 3 of 4 cortices” in 26 (43%) studies, “bony bridging of cortices” in 21 (35%) studies, and “complete bridging of cortices” in 9 (15%) studies. Two studies included additional assessment of radiographic union using the Radiographic Union Scale in Tibial fracture (RUST) or modified Radiographic Union Scale in Tibial fracture (mRUST) scores. One study included description of validity, and the other study included reliability testing. The reported mean union rate of distal femur fractures was 89% (range 58%-100%). The mean time to fracture union was documented in 49 studies and found to be 18 weeks (range 12-36 weeks) in 2,441 cases. No studies reported correlations between functional outcomes and radiographic parameters. Conclusion: The current literature evaluating surgically treated distal femur fractures lacks consistent definition of radiographic fracture union, and the appropriate time point to make this judgement is unclear. To advance surgical optimization, it is necessary that future research uses validated, reliable, and continuous measures of radiographic bone healing and correlation with functional outcomes. Level of Evidence: Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 30 June 2023
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 29 (4) , 1078-1084
Effect of humeral rotation on the reliability of radiographic measurements for proximal humerus fractures
- 30 June 2023
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 29 (4) , 1078-1084
Effect of humeral rotation on the reliability of radiographic measurements for proximal humerus fractures
- 1 September 2021
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (9) , 1505-1513
Tibiofemoral contact and alignment in patients with anterior cruciate ligament rupture treated nonoperatively versus reconstruction
Aims: Anterior cruciate ligament (ACL) rupture commonly leads to post-traumatic osteoarthritis, regardless of surgical reconstruction. This study uses standing MRI to investigate changes in contact area, contact centroid location, and tibiofemoral alignment between ACL-injured knees and healthy controls, to examine the effect of ACL reconstruction on these parameters. Methods: An upright, open MRI was used to directly measure tibiofemoral contact area, centroid location, and alignment in 18 individuals with unilateral ACL rupture within the last five years. Eight participants had been treated nonoperatively and ten had ACL reconstruction performed within one year of injury. All participants were high-functioning and had returned to sport or recreational activities. Healthy contralateral knees served as controls. Participants were imaged in a standing posture with knees fully extended. Results: Participants’ mean age was 28.4 years (SD 7.3), the mean time since injury was 2.7 years (SD 1.6), and the mean International Knee Documentation Subjective Knee Form score was 84.4 (SD 13.5). ACL injury was associated with a 10% increase (p = 0.001) in contact area, controlling for compartment, sex, posture, age, body mass, and time since injury. ACL injury was associated with a 5.2% more posteriorly translated medial centroid (p = 0.001), equivalent to a 2.6 mm posterior translation on a representative tibia with mean posteroanterior width of 49.4 mm. Relative to the femur, the tibiae of ACL ruptured knees were 2.3 mm more anteriorly translated (p = 0.003) and 2.6° less externally rotated (p = 0.010) than healthy controls. ACL reconstruction was not associated with an improvement in any measure. Conclusion: ACL rupture was associated with an increased contact area, posteriorly translated medial centroid, anterior tibial translation, and reduced tibial external rotation in full extension. These changes were present 2.7 years post-injury regardless of ACL reconstruction status. Cite this article: Bone Joint J 2021;103-B(9):1505–1513.
- 1 September 2021
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (9) , 1505-1513
Tibiofemoral contact and alignment in patients with anterior cruciate ligament rupture treated nonoperatively versus reconstruction
Aims: Anterior cruciate ligament (ACL) rupture commonly leads to post-traumatic osteoarthritis, regardless of surgical reconstruction. This study uses standing MRI to investigate changes in contact area, contact centroid location, and tibiofemoral alignment between ACL-injured knees and healthy controls, to examine the effect of ACL reconstruction on these parameters. Methods: An upright, open MRI was used to directly measure tibiofemoral contact area, centroid location, and alignment in 18 individuals with unilateral ACL rupture within the last five years. Eight participants had been treated nonoperatively and ten had ACL reconstruction performed within one year of injury. All participants were high-functioning and had returned to sport or recreational activities. Healthy contralateral knees served as controls. Participants were imaged in a standing posture with knees fully extended. Results: Participants’ mean age was 28.4 years (SD 7.3), the mean time since injury was 2.7 years (SD 1.6), and the mean International Knee Documentation Subjective Knee Form score was 84.4 (SD 13.5). ACL injury was associated with a 10% increase (p = 0.001) in contact area, controlling for compartment, sex, posture, age, body mass, and time since injury. ACL injury was associated with a 5.2% more posteriorly translated medial centroid (p = 0.001), equivalent to a 2.6 mm posterior translation on a representative tibia with mean posteroanterior width of 49.4 mm. Relative to the femur, the tibiae of ACL ruptured knees were 2.3 mm more anteriorly translated (p = 0.003) and 2.6° less externally rotated (p = 0.010) than healthy controls. ACL reconstruction was not associated with an improvement in any measure. Conclusion: ACL rupture was associated with an increased contact area, posteriorly translated medial centroid, anterior tibial translation, and reduced tibial external rotation in full extension. These changes were present 2.7 years post-injury regardless of ACL reconstruction status. Cite this article: Bone Joint J 2021;103-B(9):1505–1513.
- 1 November 2020
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 34 (11) , 600-605
Measuring Lateral Screw Protuberance Is a Clinically Accurate Method for Quantifying Femoral Neck Shortening
Objectives: The purpose of this study is to compare the reliability and accuracy of the screw protuberance method (SPM) and overlay method (OM) for measuring femoral neck shortening on anterior–posterior (AP) radiographs. The secondary aim is to investigate the changes in reliability and accuracy with varying femoral rotation. Methods: Radio-opaque femur sawbone models were fitted with either 3 cancellous screws or a sliding hip screw implant. Anterior–posterior radiographs were obtained using C-arm fluoroscopy with femoral neck shortening up to 15 mm and with the femoral shaft in 30 degrees of internal rotation to 30 degrees of external rotation (ER). Four observers measured femoral neck shortening at 2 time points. Intraobserver and interobserver reliability were calculated using the intraclass coefficient. Accuracy was analyzed through a Bland–Altman agreement statistic stratified by femoral rotation. Results: Both measurement techniques displayed excellent reliability, regardless of femoral rotation or implant. There was a significant difference in femoral neck shortening measurements with rotation for both the OM (P < 0.001) and SPM (P < 0.001). Both methods are accurate within 1 mm of the actual magnitude of shortening from 30-degree internal rotation to 15-degree ER. At 30-degree ER, shortening was underestimated by −2.10 mm using the OM (95% confidence interval, −2.43 to −1.76; P < 0.01) and by −1.64 mm using the SPM (95% confidence interval, −1.83 to −1.45; P < 0.01). Conclusion: This study demonstrates that both the OM and SPM are accurate and reliable assessments for femoral neck shortening; however, both methods are sensitive to extreme ER. Given the simplicity of the SPM technique, it may have increased utility for pragmatic research studies.
- 1 November 2020
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 34 (11) , 600-605
Measuring Lateral Screw Protuberance Is a Clinically Accurate Method for Quantifying Femoral Neck Shortening
Objectives: The purpose of this study is to compare the reliability and accuracy of the screw protuberance method (SPM) and overlay method (OM) for measuring femoral neck shortening on anterior–posterior (AP) radiographs. The secondary aim is to investigate the changes in reliability and accuracy with varying femoral rotation. Methods: Radio-opaque femur sawbone models were fitted with either 3 cancellous screws or a sliding hip screw implant. Anterior–posterior radiographs were obtained using C-arm fluoroscopy with femoral neck shortening up to 15 mm and with the femoral shaft in 30 degrees of internal rotation to 30 degrees of external rotation (ER). Four observers measured femoral neck shortening at 2 time points. Intraobserver and interobserver reliability were calculated using the intraclass coefficient. Accuracy was analyzed through a Bland–Altman agreement statistic stratified by femoral rotation. Results: Both measurement techniques displayed excellent reliability, regardless of femoral rotation or implant. There was a significant difference in femoral neck shortening measurements with rotation for both the OM (P < 0.001) and SPM (P < 0.001). Both methods are accurate within 1 mm of the actual magnitude of shortening from 30-degree internal rotation to 15-degree ER. At 30-degree ER, shortening was underestimated by −2.10 mm using the OM (95% confidence interval, −2.43 to −1.76; P < 0.01) and by −1.64 mm using the SPM (95% confidence interval, −1.83 to −1.45; P < 0.01). Conclusion: This study demonstrates that both the OM and SPM are accurate and reliable assessments for femoral neck shortening; however, both methods are sensitive to extreme ER. Given the simplicity of the SPM technique, it may have increased utility for pragmatic research studies.