Tianju Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tianju Ma has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Zi Ye
Department of Ophthalmology, Third Medical Center of Chinese PLA General Hospital, No.69 Yongding Road, Haidian District, Beijing, 100039, China; School of Medicine, Nankai University, Tianjin, 300071, China; Chinese PLA Medical School, Beijing, 100039, China
7 shared publications - Zhaohui Li
Senior Department of Ophthalmology, The Third Medical Center of Chinese PLA General Hospital, Beijing, China
6 shared publications - Jinglan Li
Medical School of Chinese PLA, Beijing, China
3 shared publications - Wenqian Chen
Department of Ophthalmology, Third Medical Center of Chinese PLA General Hospital, No.69 Yongding Road, Haidian District, Beijing, 100039, China; Chinese PLA Medical School, Beijing, 100039, China
3 shared publications - Guangcan Xu
School of Medicine, Nankai University, Tianjin, China
2 shared publications - Hongyu Li
Medical School of Chinese People’s Liberation Army, No. 28 Fuxing Road, Haidian District, Beijing 100853, China
2 shared publications
Latest Publications
- Open Access
- 3 May 2023
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 12 (4) , 1893-1912
Development and Validation of a Prediction Model for Nd:YAG Laser Capsulotomy: A Retrospective Cohort Study of 9768 eyes
Introduction Posterior capsular opacification (PCO) is the most common complication of cataract surgery. In this study, we develop a model to quantitatively predict the probability of Nd:YAG laser capsulotomy for vision-threatening PCO to improve the life quality of postoperative patients. Methods A registry analysis of cataract procedures performed between the years 2010 and 2021. Following the screening of 16,802 patients (25,883 eyes), 9768 patients (eyes) were enrolled. The cohort was randomly divided into two groups: training (n = 6838) and validation (n = 2930). To identify relevant risk factors, univariate, multivariate, and Least Absolute Shrinkage and Selection Operator (LASSO) algorithm Cox regression analysis were employed, and a nomogram was created to demonstrate the prediction result. Results At 5 years, the overall cumulative incidence of Nd:YAG laser capsulotomy was 12.0% (1169/9768). The following variables were included in the prediction model: sex [hazard ratio (HR) = 1.53, 95% CI 1.32–1.76], age (HR = 0.71, 95% CI 0.56–0.88), intraocular lens (IOL) material (HR = 2.65, 95% CI 2.17–3.24), high myopia (HR = 2.28, 95% CI 1.90–2.75), and fibrinogen (HR = 0.79, 95% CI 0.72–0.88). In the validation cohort, the area under the curve (AUC) of 1-, 3-, and 5-year predictions for Nd:YAG laser capsulotomy were 0.702, 0.691, and 0.688, respectively. For a subgroup of patients with high myopia, the protective effect of hydrophobic IOL disappeared (HR = 0.68, 95% CI 0.51–1.12, P = 0.127). Conclusion This model could predict the probability of Nd:YAG laser capsulotomy for vision-threatening PCO after cataract surgery by taking into account factors such as age, gender, IOL material, high myopia, and fibrinogen. Meanwhile, implantation of a hydrophobic IOL in individuals with high myopia did not demonstrate a protective impact against vision-threatening PCO.
- 3 May 2023
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 12 (4) , 1893-1912
Open AccessDevelopment and Validation of a Prediction Model for Nd:YAG Laser Capsulotomy: A Retrospective Cohort Study of 9768 eyes
Introduction Posterior capsular opacification (PCO) is the most common complication of cataract surgery. In this study, we develop a model to quantitatively predict the probability of Nd:YAG laser capsulotomy for vision-threatening PCO to improve the life quality of postoperative patients. Methods A registry analysis of cataract procedures performed between the years 2010 and 2021. Following the screening of 16,802 patients (25,883 eyes), 9768 patients (eyes) were enrolled. The cohort was randomly divided into two groups: training (n = 6838) and validation (n = 2930). To identify relevant risk factors, univariate, multivariate, and Least Absolute Shrinkage and Selection Operator (LASSO) algorithm Cox regression analysis were employed, and a nomogram was created to demonstrate the prediction result. Results At 5 years, the overall cumulative incidence of Nd:YAG laser capsulotomy was 12.0% (1169/9768). The following variables were included in the prediction model: sex [hazard ratio (HR) = 1.53, 95% CI 1.32–1.76], age (HR = 0.71, 95% CI 0.56–0.88), intraocular lens (IOL) material (HR = 2.65, 95% CI 2.17–3.24), high myopia (HR = 2.28, 95% CI 1.90–2.75), and fibrinogen (HR = 0.79, 95% CI 0.72–0.88). In the validation cohort, the area under the curve (AUC) of 1-, 3-, and 5-year predictions for Nd:YAG laser capsulotomy were 0.702, 0.691, and 0.688, respectively. For a subgroup of patients with high myopia, the protective effect of hydrophobic IOL disappeared (HR = 0.68, 95% CI 0.51–1.12, P = 0.127). Conclusion This model could predict the probability of Nd:YAG laser capsulotomy for vision-threatening PCO after cataract surgery by taking into account factors such as age, gender, IOL material, high myopia, and fibrinogen. Meanwhile, implantation of a hydrophobic IOL in individuals with high myopia did not demonstrate a protective impact against vision-threatening PCO.
- Open Access
- 6 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1290
Research on Establishing Corneal Edema after Phacoemulsification Prediction Model Based on Variable Selection with Copula Entropy
Background: Corneal edema (CE) affects the outcome of phacoemulsification. Effective ways to predict the CE after phacoemulsification are needed. Methods: On the basis of data from patients conforming to the protocol of the AGSPC trial, 17 variables were selected to predict CE after phacoemulsification by constructing a CE nomogram through multivariate logistic regression, which was improved via variable selection with copula entropy. The prediction models were evaluated using predictive accuracy, the area under the receiver operating characteristic curve (AUC), and decision curve analysis (DCA). Results: Data from 178 patients were used to construct prediction models. After copula entropy variable selection, which shifted the variables used for prediction in the CE nomogram from diabetes, best corrected visual acuity (BCVA), lens thickness and cumulative dissipated energy (CDE) to CDE and BCVA in the Copula nomogram, there was no significant change in predictive accuracy (0.9039 vs. 0.9098). There was also no significant difference in AUCs between the CE nomogram and the Copula nomogram (0.9637, 95% CI 0.9329–0.9946 vs. 0.9512, 95% CI 0.9075–0.9949; p = 0.2221). DCA suggested that the Copula nomogram has clinical application. Conclusions: This study obtained a nomogram with good performance to predict CE after phacoemulsification, and showed the improvement of copula entropy for nomogram models.
- 6 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1290
Open AccessResearch on Establishing Corneal Edema after Phacoemulsification Prediction Model Based on Variable Selection with Copula Entropy
Background: Corneal edema (CE) affects the outcome of phacoemulsification. Effective ways to predict the CE after phacoemulsification are needed. Methods: On the basis of data from patients conforming to the protocol of the AGSPC trial, 17 variables were selected to predict CE after phacoemulsification by constructing a CE nomogram through multivariate logistic regression, which was improved via variable selection with copula entropy. The prediction models were evaluated using predictive accuracy, the area under the receiver operating characteristic curve (AUC), and decision curve analysis (DCA). Results: Data from 178 patients were used to construct prediction models. After copula entropy variable selection, which shifted the variables used for prediction in the CE nomogram from diabetes, best corrected visual acuity (BCVA), lens thickness and cumulative dissipated energy (CDE) to CDE and BCVA in the Copula nomogram, there was no significant change in predictive accuracy (0.9039 vs. 0.9098). There was also no significant difference in AUCs between the CE nomogram and the Copula nomogram (0.9637, 95% CI 0.9329–0.9946 vs. 0.9512, 95% CI 0.9075–0.9949; p = 0.2221). DCA suggested that the Copula nomogram has clinical application. Conclusions: This study obtained a nomogram with good performance to predict CE after phacoemulsification, and showed the improvement of copula entropy for nomogram models.
- Open Access
- 12 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (2) , 611
Application of the Active-Fluidics System in Phacoemulsification: A Review
The fluidics system is an indispensable and primary component of phacoemulsification. Both the gravity-fluidics system and active-fluidics system are commonly used in practice. The irrigation pressure of the gravity-fluidics system is determined by the bottle height, which is relatively constant, while the active-fluidics system is paired with a cassette that contains pressure sensors to monitor intraocular pressure changes. The active-fluidics system allows surgeons to preset a target intraocular pressure value, and it replenishes the fluids proactively; thus, the intraocular pressure is consistently maintained near the target value. Under such circumstances, stable intraocular pressure and anterior chamber volume values could be acquired. Research on surgical safety, efficiency and results have reported several strengths of the active-fluidics system. It is also advantageous in some complicated cataract surgeries. However, the system is not widely used at present, mainly due to its low penetration rate and high equipment cost. Some of its updates such as the new Active Sentry handpiece showed potential superiority in laboratory studies recently, but there is still further research to be conducted. This article gives an overview of the mechanism and performance of the active-fluidics system, and it is expected to provide clues for future research.
- 12 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (2) , 611
Open AccessApplication of the Active-Fluidics System in Phacoemulsification: A Review
The fluidics system is an indispensable and primary component of phacoemulsification. Both the gravity-fluidics system and active-fluidics system are commonly used in practice. The irrigation pressure of the gravity-fluidics system is determined by the bottle height, which is relatively constant, while the active-fluidics system is paired with a cassette that contains pressure sensors to monitor intraocular pressure changes. The active-fluidics system allows surgeons to preset a target intraocular pressure value, and it replenishes the fluids proactively; thus, the intraocular pressure is consistently maintained near the target value. Under such circumstances, stable intraocular pressure and anterior chamber volume values could be acquired. Research on surgical safety, efficiency and results have reported several strengths of the active-fluidics system. It is also advantageous in some complicated cataract surgeries. However, the system is not widely used at present, mainly due to its low penetration rate and high equipment cost. Some of its updates such as the new Active Sentry handpiece showed potential superiority in laboratory studies recently, but there is still further research to be conducted. This article gives an overview of the mechanism and performance of the active-fluidics system, and it is expected to provide clues for future research.
- 1 October 2022
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 43 (1) , 73-82
Effect of illuminance and colour temperature of LED lighting on asthenopia during reading
Purpose: A self‐controlled study to determine the influence of illuminance and correlated colour temperature (CCT) of light‐emitting diode (LED) lighting on asthenopia. Methods: Twenty‐two healthy postgraduates (nine women) were recruited to read under eight LED lighting conditions with four illuminances (300 lx, 500 lx, 750 lx and 1000 lx) and four CCTs (2700, 4000, 5000 and 6500 K) for 2 h. A subjective asthenopia questionnaire, the optical quality analysis system (OQAS) and an inflammatory cytokine assay were used to assess the levels of asthenopia. Results: Increased asthenopia was observed after reading, but the degree varied with lighting conditions. There were significant differences among the groups in terms of subjective symptoms (inattention, eye pain, dry eye and total score), optical performance parameters (modulation transfer function [MTF] cut‐off frequency, Strehl ratio [SR], objective scattering index [OSI], mean OSI and accommodative amplitude [AA]) as well as inflammatory cytokines in the tears (epidermal growth factor [EGF], transforming growth factor [TGF]‐α, interleukin [IL]‐6, IL‐8, macrophage inflammatory protein [MIP]‐1β, tumour necrosis factor [TNF]‐α, TNF‐β and vascular endothelial growth factor [VEGF]‐A). All of the subjective and objective measurements collectively suggested that asthenopia was lessened for the 500 lx–4000 K condition. However, asthenopia was significantly worse for 300 lx–2700 K and 1000 lx–6500 K in terms of subjective symptoms and objective optical performance, respectively. Conclusions: LED illuminance and CCT do have a significant effect on asthenopia during reading. 500 lx–4000 K lighting resulted in the lowest level of asthenopia. Conversely, low illuminance at low CCT (300 lx–2700 K) and high illuminance at high CCT (1000 lx–6500 K) promoted more severe asthenopia.
- 1 October 2022
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 43 (1) , 73-82
Effect of illuminance and colour temperature of LED lighting on asthenopia during reading
Purpose: A self‐controlled study to determine the influence of illuminance and correlated colour temperature (CCT) of light‐emitting diode (LED) lighting on asthenopia. Methods: Twenty‐two healthy postgraduates (nine women) were recruited to read under eight LED lighting conditions with four illuminances (300 lx, 500 lx, 750 lx and 1000 lx) and four CCTs (2700, 4000, 5000 and 6500 K) for 2 h. A subjective asthenopia questionnaire, the optical quality analysis system (OQAS) and an inflammatory cytokine assay were used to assess the levels of asthenopia. Results: Increased asthenopia was observed after reading, but the degree varied with lighting conditions. There were significant differences among the groups in terms of subjective symptoms (inattention, eye pain, dry eye and total score), optical performance parameters (modulation transfer function [MTF] cut‐off frequency, Strehl ratio [SR], objective scattering index [OSI], mean OSI and accommodative amplitude [AA]) as well as inflammatory cytokines in the tears (epidermal growth factor [EGF], transforming growth factor [TGF]‐α, interleukin [IL]‐6, IL‐8, macrophage inflammatory protein [MIP]‐1β, tumour necrosis factor [TNF]‐α, TNF‐β and vascular endothelial growth factor [VEGF]‐A). All of the subjective and objective measurements collectively suggested that asthenopia was lessened for the 500 lx–4000 K condition. However, asthenopia was significantly worse for 300 lx–2700 K and 1000 lx–6500 K in terms of subjective symptoms and objective optical performance, respectively. Conclusions: LED illuminance and CCT do have a significant effect on asthenopia during reading. 500 lx–4000 K lighting resulted in the lowest level of asthenopia. Conversely, low illuminance at low CCT (300 lx–2700 K) and high illuminance at high CCT (1000 lx–6500 K) promoted more severe asthenopia.
- Open Access
- 26 August 2022
- Published by Springer Nature in Diabetology & Metabolic Syndrome
- Vol. 14 (1) , 1-12
A prediction model for worsening diabetic retinopathy after panretinal photocoagulation
Background: As one of the severe complications of diabetes mellitus, diabetic retinopathy (DR) is the leading cause of blindness in the working age worldwide. Although panretinal photocoagulation (PRP) was standard treatment, PRP-treated DR still has a high risk of progression. Hence, this study aimed to assess the risk factors and establish a model for predicting worsening diabetic retinopathy (DR-worsening) within five years after PRP. Methods: Patients who were diagnosed with severe non-proliferative diabetic retinopathy or proliferative diabetic retinopathy and treated with PRP were included, and those patients were randomly assigned to either a training or validation cohort. The multivariate logistic regression analysis was used to screen potential risk factors for DR-worsening in the training cohort. Then the model was established after including significant independent risk factors and further validated using discrimination and calibration. Results: A total of 271 patients were included, and 56.46% of patients had an outcome of DR-worsening. In the training cohort (n = 135), age (odds ratio [OR] = 0.94, 95% confidence interval [CI] 0.90–0.98), baseline best corrected visual acuity (logMAR) (OR = 10.74, 95% CI 1.84–62.52), diabetic nephropathy (OR = 9.32, 95% CI 1.49–58.46), and hyperlipidemia (OR = 3.34, 95% CI 1.05–10.66) were screened out as the independent risk factors, which were incorporated into the predictive model. The area under the receiver operating characteristic curve and calibration slope in the training and validation cohort were 0.79, 0.96 (95% CI 0.60–1.31), and 0.79, 1.00 (95% CI 0.66–1.34), respectively. Two risk groups were developed depending on the best cut-off value of the predicted probability, and the actual probability was 34.90% and 82.79% in the low-risk and high-risk groups, respectively (P < 0.001). Conclusions: This study developed and internally validated a new model to predict the probability of DR-worsening after PRP treatment within five years. The model can be used as a rapid risk assessment system for clinical prediction of DR-worsening and identify individuals at a high risk of DR-worsening at an early stage and prescribe additional treatment.
- 26 August 2022
- Published by Springer Nature in Diabetology & Metabolic Syndrome
- Vol. 14 (1) , 1-12
Open AccessA prediction model for worsening diabetic retinopathy after panretinal photocoagulation
Background: As one of the severe complications of diabetes mellitus, diabetic retinopathy (DR) is the leading cause of blindness in the working age worldwide. Although panretinal photocoagulation (PRP) was standard treatment, PRP-treated DR still has a high risk of progression. Hence, this study aimed to assess the risk factors and establish a model for predicting worsening diabetic retinopathy (DR-worsening) within five years after PRP. Methods: Patients who were diagnosed with severe non-proliferative diabetic retinopathy or proliferative diabetic retinopathy and treated with PRP were included, and those patients were randomly assigned to either a training or validation cohort. The multivariate logistic regression analysis was used to screen potential risk factors for DR-worsening in the training cohort. Then the model was established after including significant independent risk factors and further validated using discrimination and calibration. Results: A total of 271 patients were included, and 56.46% of patients had an outcome of DR-worsening. In the training cohort (n = 135), age (odds ratio [OR] = 0.94, 95% confidence interval [CI] 0.90–0.98), baseline best corrected visual acuity (logMAR) (OR = 10.74, 95% CI 1.84–62.52), diabetic nephropathy (OR = 9.32, 95% CI 1.49–58.46), and hyperlipidemia (OR = 3.34, 95% CI 1.05–10.66) were screened out as the independent risk factors, which were incorporated into the predictive model. The area under the receiver operating characteristic curve and calibration slope in the training and validation cohort were 0.79, 0.96 (95% CI 0.60–1.31), and 0.79, 1.00 (95% CI 0.66–1.34), respectively. Two risk groups were developed depending on the best cut-off value of the predicted probability, and the actual probability was 34.90% and 82.79% in the low-risk and high-risk groups, respectively (P < 0.001). Conclusions: This study developed and internally validated a new model to predict the probability of DR-worsening after PRP treatment within five years. The model can be used as a rapid risk assessment system for clinical prediction of DR-worsening and identify individuals at a high risk of DR-worsening at an early stage and prescribe additional treatment.
- Open Access
- 14 April 2020
- Published by Springer Nature in BMC Ophthalmology
- Vol. 20 (1) , 1-9
Identification of potential molecular targets associated with proliferative diabetic retinopathy
Background: This study aimed to identify and evaluate potential molecular targets associated with the development of proliferative diabetic retinopathy (DR).Methods: The microarray dataset “GSE60436” generated from fibrovascular membranes (FVMs) associated with proliferative DR was downloaded from the Gene Expression Omnibus database. Differentially expressed genes (DEGs) from the active FVMs and control or inactive FVMs and control were evaluated and co-DEGs were identified using VEEN analysis. Functional enrichment analysis, and protein-protein interactions (PPI) network and module analyses were performed on the upregulated and downregulated coDEGs. Finally, several predictions regarding microRNAs (miRNAs) and transcription factors (TFs) were made to construct a putative TF-miRNA-target network.Results: A total of 1475 co-DEGs were screened in active/inactive FVM samples, including 461 upregulated and 1014 downregulated genes, which were enriched for angiogenesis [Hypoxia Inducible Factor 1 Subunit Alpha (HIF1A) and Placental Growth Factor (PGF)] and visual perception, respectively. In the case of the upregulated co-DEGs, Kinesin Family Member 11 (KIF11), and BUB1 Mitotic Checkpoint Serine/Threonine Kinase (BUB1) exhibited the highest values in both the PPI network and module analyses, as well as the genes related to mitosis. In the case of downregulated co-DEGs, several G protein subunits, including G Protein Subunit Beta 3 (GNB3), exhibited the highest values in both the PPI network and module analyses. The genes identified in the module analysis were found to be from the signal transduction-related pathways. In addition, we were able to identify four miRNAs and five TFs, including miR-136 and miR-374.Conclusions: In brief, HIF1A, PGF, KIF11, G protein subunits, and miR-136, miR-374 may all be involved in angiogenesis, retinal endothelial cell proliferation, and visual signal transduction in proliferative DR. This study provides a number of novel insights that may aid the development of future studies dedicated to discovering novel therapeutic targets in proliferative DR.
- 14 April 2020
- Published by Springer Nature in BMC Ophthalmology
- Vol. 20 (1) , 1-9
Open AccessIdentification of potential molecular targets associated with proliferative diabetic retinopathy
Background: This study aimed to identify and evaluate potential molecular targets associated with the development of proliferative diabetic retinopathy (DR).Methods: The microarray dataset “GSE60436” generated from fibrovascular membranes (FVMs) associated with proliferative DR was downloaded from the Gene Expression Omnibus database. Differentially expressed genes (DEGs) from the active FVMs and control or inactive FVMs and control were evaluated and co-DEGs were identified using VEEN analysis. Functional enrichment analysis, and protein-protein interactions (PPI) network and module analyses were performed on the upregulated and downregulated coDEGs. Finally, several predictions regarding microRNAs (miRNAs) and transcription factors (TFs) were made to construct a putative TF-miRNA-target network.Results: A total of 1475 co-DEGs were screened in active/inactive FVM samples, including 461 upregulated and 1014 downregulated genes, which were enriched for angiogenesis [Hypoxia Inducible Factor 1 Subunit Alpha (HIF1A) and Placental Growth Factor (PGF)] and visual perception, respectively. In the case of the upregulated co-DEGs, Kinesin Family Member 11 (KIF11), and BUB1 Mitotic Checkpoint Serine/Threonine Kinase (BUB1) exhibited the highest values in both the PPI network and module analyses, as well as the genes related to mitosis. In the case of downregulated co-DEGs, several G protein subunits, including G Protein Subunit Beta 3 (GNB3), exhibited the highest values in both the PPI network and module analyses. The genes identified in the module analysis were found to be from the signal transduction-related pathways. In addition, we were able to identify four miRNAs and five TFs, including miR-136 and miR-374.Conclusions: In brief, HIF1A, PGF, KIF11, G protein subunits, and miR-136, miR-374 may all be involved in angiogenesis, retinal endothelial cell proliferation, and visual signal transduction in proliferative DR. This study provides a number of novel insights that may aid the development of future studies dedicated to discovering novel therapeutic targets in proliferative DR.
- 1 April 2018
- Published by Elsevier in Experimental Eye Research
- Vol. 169, 28-37
Nrf2 protects human lens epithelial cells against H 2 O 2 -induced oxidative and ER stress: The ATF4 may be involved
- 1 April 2018
- Published by Elsevier in Experimental Eye Research
- Vol. 169, 28-37
Nrf2 protects human lens epithelial cells against H 2 O 2 -induced oxidative and ER stress: The ATF4 may be involved
- 1 May 2016
- Published by Elsevier in Experimental Eye Research
- Vol. 146, 318-329
Heme oxygenase-1 (HO-1) protects human lens epithelial cells (SRA01/04) against hydrogen peroxide (H2O2)-induced oxidative stress and apoptosis
- 1 May 2016
- Published by Elsevier in Experimental Eye Research
- Vol. 146, 318-329
Heme oxygenase-1 (HO-1) protects human lens epithelial cells (SRA01/04) against hydrogen peroxide (H2O2)-induced oxidative stress and apoptosis