MDMaxwell Dias

Maxwell Dias

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maxwell Dias has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of Uptake Period on 18F-DCFPyL-PSMA PET/CT Maximum Standardised Uptake Value

    by Anthony-Joe Nassour, Anika Jain, Hadia Khanani, Nicholas Hui, Nadine J. Thompson, Brian Sorensen, Sris Baskaranathan, Philip Bergersen, Venu Chalasani, Thomas Dean, et al.

    Background: The maximum standardised uptake value (SUVmax) can potentially be affected by the uptake period during PSMA PET imaging. The optimal image acquisition period for 2-(3-{1-carboxy-5-[(6-18F-fluoro-pyridine-3-carbonyl)-amino]-pentyl}-ureido)-pentanedioic acid (18F-DCFPyL)PSMA PET/CT is yet to be established. This study aims to evaluate the effect of the uptake period on the SUVmax in diagnosing localised, clinically significant prostate cancer using 18F-DCFPyL-PSMA PET/CT. Methods: Sixty biopsy-naive men with one or more PI-RADS 4 or 5 lesions of at least 10 mm on multiparametric MRI (mpMRI) were enrolled to undergo 18F-DCFPyL-PSMA PET/CT. SUVmax was prospectively measured following an uptake period of 60, 90 and 120 min post injection of 18F-DCFPyL-PSMA radiotracer. Concordance with biopsy results or final histopathology was recorded. Results: Mean absolute differences in SUVmax at 60 vs. 90, 60 vs. 120, and 90 vs. 120 min uptake periods were 3.23 (SD 4.76), 4.53 (SD 7.33), and 3.24 (SD 4.56), respectively. This represents a statistically significant systematic increase in SUVmax (p-value < 0.001) with increasing uptake period. The interval between the uptake period of 60 vs. 120 min represented the largest SUVmax change of 29.98%. Conclusions: The SUVmax is a dynamic variable significantly affected by uptake period. Our study supports image acquisition at 120 min following injection of 18F-DCFPyL radiotracer. Further studies are needed to determine if this acquisition period can be applied to other Fluorine-18 based PSMA radiotracers.

  • Box, cable and smartphone: a simple laparoscopic trainer

    by Migie Lee, Jason Savage, Maxwell Dias, Philip Bergersen, Matthew Winter

    Summary: Background: Laparoscopic surgery requires different abilities to open surgery, and is challenging to learn within the confines of the operating theatre. With the development of laparoscopic surgery in modern surgery, the importance in improving these skills is becoming an increasing focus of surgical training programmes. Context: The assembly of the laparoscopic trainer and exercises was performed at the University of Sydney Clinical School located at Hornsby Hospital in Sydney, Australia. The objective was to design and construct a new concept smartphone box laparoscopic trainer that is affordable and replicable, and to demonstrate its usefulness in practising laparoscopic techniques to improve skills outside of the operating theatre. Innovation: The trainer was constructed using a personal smartphone, cardboard box, video graphics array ( VGA ) adaptor, VGA cable and a computer screen. Laparoscopic instruments and materials used for simulated task exercises were obtained from the operating theatre. Simulated demonstrations of simple laparoscopic tasks included suture handling, instrument knot‐tying and anastomotic suture techniques. Implications: The smartphone box trainer is inexpensive (approximately $60) and took less than 20 minutes to build. The cost was almost entirely for the VGA adaptor. The box trainer was light, portable and easily transported to any setting that provided a computer screen. It is an inexpensive, easy‐to‐assemble, replicable model that benefits from the advanced technology of personal smartphones, and can be easily accessed as a useful tool in learning and improving laparoscopic techniques. Laparoscopic surgery requires different abilities to open surgery


  • Bladder scanner pitfalls: beware ovarian cysts

    by Daman Bhatia, Matthew Winter, Maxwell Dias, Venu Chalasani


  • Open Access

    Fibrous Pseudotumor of the Penis – An Unusual Finding During Repair of Fractured Penis

    by Sunny Nalavenkata, Matthew Winter, Justine Pickett, Maxwell Dias, Venu Chalasani

  • Benign Retroperitoneal Cyst of Mullerian Type

    by Jay Yohendran, Maxwell M. Dias, Robert Eckstein, Tim Wilson


  • Pattern of management of common bile duct stones in the laparoscopic era: A NSW survey

    by Maxwell M. Dias, Christopher J. Martin, Michael R. Cox

    Background: The management of common bile duct (CBD) stones in the laparoscopic era remains controversial with various management strategies employed by surgeons. The aim of this study was to ascertain the common practice across a single Australian state, and to see if a ‘best practice’ for CBD stone management could be established. Methods: A questionnaire was sent to 390 general surgeons in New South Wales in April 1999. Data collected included the type of practice, number of cholecystectomies performed, preoperative markers of CBD stones, indications for preoperative endoscopic retrograde cholangiopancreatography (ERCP), use of operative cholangiography (OC) and the management of CBD stones found on OC. Results: The questionnaire was returned by 223 (57%) surgeons. Fifty‐four (14%) of these respondents were excluded as they did not perform laparoscopic cholecystectomy, leaving 169 (43%) respondents for analysis. The preoperative indicators for CBD stones were ranked as: jaundice > dilated CBD on ultrasound > serum bilirubin > serum alkaline phosphatase/alanine aminotransferase > previous biliary pancreatitis. Preoperative ERCP would be performed by 88% for persistent jaundice or cholangitis, 33% for elevated liver function test, 25% for dilated CBD and 24% for biliary pancreatitis. Operative cholangiography is routinely performed by 67%, selectively by 29% and never by 4%. If CBD stones are encountered 47% would attempt laparoscopic clearance via the cystic duct or choledochotomy; however, 72% replied that they would use postoperative ERCP as part of their usual strategy for the management of CBD stones. Conclusions: There was no clear common pattern for the management of suspected or proven CBD stones. There were three management issues in which there was a ‘common practice’. These were: (i) the use of preoperative ERCP for patients with persistent jaundice or cholangitis; and the routine use of (ii) OC and (iii) postoperative ERCP to clear the CBD, assuming other methods had failed.


  • SENTINEL NODE BIOPSY IN BREAST CANCER: RESULTS OF 103 CASES

    by J. Gail Molland, Maxwell M. Dias, David J. Gillett

    Background: In early breast cancer the status of the axillary nodes has been shown to be one of the primary prognostic indicators. Biopsy of the sentinel node, or first draining lymph node, of a tumour has been investigated as an alternative to axillary dissection in early breast cancer. A series of sentinel node biopsies in 103 patients is reported here. Methods: Both pre‐operative lymphoscintigraphy and intra‐operative blue dye were used to map the sentinel nodes. Results: Mapping was successful in 87 (84.4%) cases and sentinel nodes were retrieved in 94.2% of these patients. Where lymphoscintigraphic mapping was unsuccessful, sentinel nodes were found in 37.5%. When sentinel nodes were retrieved, correlation of the sentinel node status with the axillary nodes was accurate in 97.5%. There were two false negatives, both in large tumours. The sentinel node status was an accurate predictor of axillary status in 95.7% of the node positive patients. Conclusions: If only the 86 patients with invasive carcinoma and four or more axillary nodes removed at surgery are considered, the sentinel node was accurate in assessing the axillary status in 97.7% of the total patient group (2.3% false negative rate), 97.2% of those in whom sentinel nodes were successfully retrieved (2.8% false negative rate) and 94.9% of the patients with positive axillary nodes (5.1% false negative rate). Sentinel node biopsy is a valid technique providing an accurate reflection of the axillary node status and having a low false negative rate.