ELEnrico Lucon

Enrico Lucon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Enrico Lucon has a total of 197 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Influence of Ligament Length and Corresponding Tolerances on the Results of Charpy Impact Tests

    by Enrico Lucon

    The most popular international test standards for Charpy testing, namely ASTM E23-25, Standard Test Methods for Notched Bar Impact Testing of Metallic Materials, ASTM A370-24a, Standard Test Methods and Definitions for Mechanical Testing of Steel Products, and ISO 148-1:2016, Metallic Materials—Charpy Pendulum Impact Test—Part 1: Test Method, prescribe significantly different tolerances for the specimen ligament length, ranging from ±0.025 mm (ASTM E23) to ±0.01 mm (ASTM A370). The study detailed in this article investigated the influence of ligament length on the absorbed energy obtained from testing reference Charpy specimens at three energy levels (low, high, and super-high). The results obtained and the outcomes of multiple statistical analyses conducted on them support the proposal to revise the ASTM standards to make them consistent with each other and with ISO 148-1 (ligament length: 8 mm ± 0.075 mm).

  • On the possibility of extracting reference Charpy Specimens from 4340 steel round bars with D ≥ 1 in.

    by Enrico Lucon, Allen C Eckhardt, Raymond L Santoyo

    We have investigated the possibility of extracting low- and high-energy reference Charpy specimens, to be certified for the indirect verification of impact machines in accordance with ASTM E23, from round bars of 4340 steel with larger diameters than the ones currently used, i.e., D ≥ 1” (25.4 mm). Larger round bars would allow extracting specimens from adjacent locations within the bar cross-section, rather than only in the center. The influence of sampling location on Charpy absorbed energy was found to be statistically significant in most investigated scenarios. However, the Charpy results obtained in every possible scenario all satisfy the NIST acceptability criterion based on sample size, and therefore indicate that the use of larger bars and side-by-side sampling is a viable option, when the currently preferred diameter (5/8”) is unavailable. Between 1” and 1 ¼” diameter bars, the former show slightly lower data scatter than the latter, but also correspond to higher estimated cost and material waste per specimen.

  • On the Possibility of Adding a Repeatability Requirement for the Indirect Verification of Charpy Machines in ASTM E23

    by Enrico Lucon

    Since 1989, the National Institute of Standards and Technology (NIST) Charpy Machine Verification Program in Boulder, Colorado, has been indirectly verifying Charpy machines around the world according to ASTM E23, Standard Test Methods for Notched Bar Impact Testing of Metallic Materials, and ISO 148-2, Metallic Materials—Charpy Pendulum Impact Test—Part 2: Verification of Testing Machines. Most of the indirect verifications results have been logged in a database, which at the end of May 2024 included 77,105 records, each one corresponding to 4–5 absorbed energy values at one of three energy levels (low, high, and super-high). Based on the analysis of this database, the acceptability criteria of ASTM E23, exclusively based on bias, have been compared with those of ISO 148-2, which also include repeatability. The objective of this study is to support the proposal of revising ASTM E23 by introducing repeatability requirements in addition to the existing bias criteria. Four proposals have been considered and assessed, leading to the selection of a set of repeatability limits (larger of 4 J and 15 % of certified absorbed energy) that only moderately increases the severity of the standard but, most importantly, prevents deeming machines acceptable that satisfy ASTM E23 bias but fail ISO 148-2 repeatability (approximately one sixth of all the machines verified by the NIST since 1990).


  • Using “off-the-shelf” AISI 4340 steel for the production of NIST reference Charpy specimens

    by Enrico Lucon, Allen Eckhardt, Raymond Santoyo

    We investigated the suitability of using readily available (“off-the-shelf”), as opposite to made-to-order, AISI 4340 steel for the production of NIST reference Charpy specimens of low- and high-energy level. This study was preceded by technical discussions inside and outside NIST, which lead to the streamlining and simplification of the technical specifications for the procurement of 4340 steel, as well as 9310 steel (used for the production of super-high-energy reference specimens). Charpy tests were performed on the three reference machines in Boulder, on trial lots of 75 specimens, heat treated and machined according to the same procedures used by our current Vendors for reference specimens. Four of the six “off-the-shelf” 4340 steel heats were found immediately acceptable according to the NIST criterion (sample size ≤ 5.0). The remaining two heats yielded sample sizes between 5 and 6, and after re-tempering and machining the few remaining blanks, the corresponding Charpy tests provided relatively low sample sizes. The outcome of this investigation supports the validity of our revised steel specifications and the acceptability of “off-the-shelf” 4340 steel batches for the Charpy Machine Verification Program.

  • Mechanical metallurgy on Columbia gas X100 experimental pipe

    by Ryan White, Jake Benzing, Enrico Lucon, Nicholas Derimow, Ashley Kroon, Robert Smith

    This study evaluates the material properties of an X100 pipeline steel extracted from an experimental transmission pipeline section placed into service in the 1960s. The purpose is to compare these properties with current X100 steel standards. Comprehensive chemical characterization, microstructure analysis, and a series of mechanical tests—including tensile, Charpy impact, and indentation tests—were conducted to assess the long-term stability and reliability of these early high-strength steels. The analysis involved seven different welded sections of the pipeline to account for potential variations within the material and welding procedures. The findings indicate significant differences in chemical composition across the various pipe sections, suggesting that these sections may represent different experimental materials. The base metal predominantly exhibited a bainite-ferrite microstructure, with noticeable variations near the pipe surfaces. Unannealed girth welds demonstrated higher toughness and increased hardness in their heat-affected zones compared to seam welds. While most sections of the vintage X100 steel met the modern tensile property requirements, several sections did not meet the impact toughness criteria. In conclusion, the experimental X100 steel aligns with current tensile property requirements, however the steel fails to meet current toughness related requirements. The observed differences in testing methods between current standards and those published in the 1960s were minor, and therefore not a convincing source for observed property differences considering all sources of uncertainty. The absence of original pre-service mechanical testing data prevents conclusions about time-dependent property changes.

  • Review and Consideration of Apparent Negative Crack Growth in Fracture Toughness Tests

    by Enrico Lucon

    Apparent negative crack growth is often encountered when performing elastic-plastic fracture toughness tests with the Elastic Compliance single-specimen technique. It consists of a decrease of specimen compliance (reduction of crack size) during the early portion of the test, before the attainment of maximum force and the onset of ductile crack extension. This phenomenon was recognized and discussed inside the fracture mechanics community since the mid-1980s, but widespread consensus was never achieved on its root causes and on the best approach to account for it in the analysis of an elastic-plastic fracture toughness test. It has been shown that both experimental (test setup) and material behavior aspects can be invoked to explain the decrease of elastic compliance that translates into decreasing crack size in the early loading stage. The current edition of ASTM E1820, Standard Test Method for Measurement of Fracture Toughness, does not offer provisions to handle this phenomenon, and users are left free to treat the issue as they see fit. In this study, several articles published in the last 40 years were reviewed, and different proposed methods were applied on 15 selected tests performed on specimens of different geometries and thicknesses. Comparisons between original crack sizes, ductile crack extensions, and critical toughness values are presented, and recommendations are provided for revising ASTM E1820 with due consideration of the occurrence of apparent negative crack growth.