Fabien Dorchies
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fabien Dorchies has a total of 946 co-authors. Here are the top co-authors by number of shared publications:
C. Fourment
Université de Bordeaux, CNRS, CEA, CELIA (Centre Lasers Intenses et Applications), UMR 5107, F-33400 Talence, France
28 shared publications- Sophie D. Baton
LULI, CNRS, Ecole Polytechnique, CEA, Sorbonne Université 3 , 91120 Palaiseau
26 shared publications O. Peyrusse
Université de Bordeaux, CNRS, CEA, Centre Lasers Intenses et Applications, UMR 5107, F-33400 Talence, France
25 shared publicationsS. Hulin
CNRS, CEA, CELIA (Centre Lasers Intenses et Applications), Univ. Bordeaux 1 , UMR 5107, F-33405 Talence, France
23 shared publications- Dimitri Batani
University of Bordeaux
20 shared publications F. Blasco
Université Bordeaux I; CNRS; CEA; CELIA UMR 5107, 351 cours de la Libération, Talence, F-33405 France
17 shared publications
Latest Publications
- Open Access
- 21 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (15)
X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
- 21 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (15)
Open AccessX-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
- Open Access
X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren. We compare the predictions of our model with femtosecond x-ray diffraction patterns obtained from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density (HED) instrument of the European X-Ray Free-Electron Laser (EuXFEL), and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show that: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
Open AccessX-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren. We compare the predictions of our model with femtosecond x-ray diffraction patterns obtained from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density (HED) instrument of the European X-Ray Free-Electron Laser (EuXFEL), and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show that: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
- Open Access
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL
In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Open AccessCalibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL
In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.
- 17 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 53 (10) , 2581-2588
Nanosecond Intense Relativistic Electron Beam Propagation in Gas and Preformed Plasma
An experimental and numerical study on the propagation of a typical flash radiography electron beam in helium gas and a preformed plasma is presented, in the context of a plasma lens applicability for such beams. The experiments consist of measuring the beam profile at the exit of an interaction chamber as a function of time, for various gas pressure and plasma densities. The plasma is produced before the beam’s arrival in the gas at $\approx 1 \times 10^{-3} \,\mathrm {mbar}$ by a seeded, pulsed inductive discharge. The plasma density reaches a peak value of $(1.2~\pm~0.4) \times 10^{12} \,\mathrm {cm}^{-3}$ then decreases exponentially over several tens of microseconds. This allows probing the propagation in different plasma densities by varying the delay between the plasma discharge and the electron beam. The influence of the preformed plasma on the beam propagation is experimentally demonstrated, as well as an evolution of the propagation at the tens of nanoseconds time scale. Simulations are carried out in the regime where the plasma density ( $2 \times 10^{10} \,\mathrm {cm}^{-3}$ or less) is lower than the beam density, using a full kinetic description with a particle-in-cell (PIC)/Monte-Carlo code. The simulations reproduce the main features of the observations, and show that after the effect of the fast plasma electron response (at the nanosecond time scale), the evolution of the propagation at the tens of nanoseconds time scale is mainly due to the plasma ion redistribution driven by the beam space charge.
- 17 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 53 (10) , 2581-2588
Nanosecond Intense Relativistic Electron Beam Propagation in Gas and Preformed Plasma
An experimental and numerical study on the propagation of a typical flash radiography electron beam in helium gas and a preformed plasma is presented, in the context of a plasma lens applicability for such beams. The experiments consist of measuring the beam profile at the exit of an interaction chamber as a function of time, for various gas pressure and plasma densities. The plasma is produced before the beam’s arrival in the gas at $\approx 1 \times 10^{-3} \,\mathrm {mbar}$ by a seeded, pulsed inductive discharge. The plasma density reaches a peak value of $(1.2~\pm~0.4) \times 10^{12} \,\mathrm {cm}^{-3}$ then decreases exponentially over several tens of microseconds. This allows probing the propagation in different plasma densities by varying the delay between the plasma discharge and the electron beam. The influence of the preformed plasma on the beam propagation is experimentally demonstrated, as well as an evolution of the propagation at the tens of nanoseconds time scale. Simulations are carried out in the regime where the plasma density ( $2 \times 10^{10} \,\mathrm {cm}^{-3}$ or less) is lower than the beam density, using a full kinetic description with a particle-in-cell (PIC)/Monte-Carlo code. The simulations reproduce the main features of the observations, and show that after the effect of the fast plasma electron response (at the nanosecond time scale), the evolution of the propagation at the tens of nanoseconds time scale is mainly due to the plasma ion redistribution driven by the beam space charge.
- Top Cited PapersOpen Access
- 21 May 2025
- Published by Springer Nature in Nature
- Vol. 642 (8067) , 351-355
The structure of liquid carbon elucidated by in situ X-ray diffraction
Carbon has a central role in biology and organic chemistry, and its solid allotropes provide the basis of much of our modern technology1. However, the liquid form of carbon remains nearly uncharted2, and the structure of liquid carbon and most of its physical properties are essentially unknown3. But liquid carbon is relevant for modelling planetary interiors4,5 and the atmospheres of white dwarfs6, as an intermediate state for the synthesis of advanced carbon materials7,8, inertial confinement fusion implosions9, hypervelocity impact events on carbon materials10 and our general understanding of structured fluids at extreme conditions11. Here we present a precise structure measurement of liquid carbon at pressures of around 1 million atmospheres obtained by in situ X-ray diffraction at an X-ray free-electron laser. Our results show a complex fluid with transient bonding and approximately four nearest neighbours on average, in agreement with quantum molecular dynamics simulations. The obtained data substantiate the understanding of the liquid state of one of the most abundant elements in the universe and can test models of the melting line. The demonstrated experimental abilities open the path to performing similar studies of the structure of liquids composed of light elements at extreme conditions.
- 21 May 2025
- Published by Springer Nature in Nature
- Vol. 642 (8067) , 351-355
Top Cited PapersOpen AccessThe structure of liquid carbon elucidated by in situ X-ray diffraction
Carbon has a central role in biology and organic chemistry, and its solid allotropes provide the basis of much of our modern technology1. However, the liquid form of carbon remains nearly uncharted2, and the structure of liquid carbon and most of its physical properties are essentially unknown3. But liquid carbon is relevant for modelling planetary interiors4,5 and the atmospheres of white dwarfs6, as an intermediate state for the synthesis of advanced carbon materials7,8, inertial confinement fusion implosions9, hypervelocity impact events on carbon materials10 and our general understanding of structured fluids at extreme conditions11. Here we present a precise structure measurement of liquid carbon at pressures of around 1 million atmospheres obtained by in situ X-ray diffraction at an X-ray free-electron laser. Our results show a complex fluid with transient bonding and approximately four nearest neighbours on average, in agreement with quantum molecular dynamics simulations. The obtained data substantiate the understanding of the liquid state of one of the most abundant elements in the universe and can test models of the melting line. The demonstrated experimental abilities open the path to performing similar studies of the structure of liquids composed of light elements at extreme conditions.
- Open Access
- 21 April 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (15)
Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering
We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of T/ΘD2, where ΘD is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.
- 21 April 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (15)
Open AccessFemtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering
We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of T/ΘD2, where ΘD is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.
- 27 September 2024
- Published by American Physical Society (APS) in Physical Review B
- Vol. 110 (10)
Interplay of thermal and nonthermal effects in x-ray-induced ultrafast melting
- 27 September 2024
- Published by American Physical Society (APS) in Physical Review B
- Vol. 110 (10)
Interplay of thermal and nonthermal effects in x-ray-induced ultrafast melting
- 29 May 2024
- Published by American Physical Society (APS) in Physical Review B
- Vol. 109 (17) , 174311
Mitigating space charge in time-resolved photoelectron spectroscopy to study laser-heated copper dynamics in the high fluence regime
The performance of time-resolved photoelectron spectroscopy for the study of subpicosecond dynamics of laser-heated solids is often limited by space charge effects. The consequent shift and distortion of the photoelectron spectrum induced by electrons emitted by the ultrashort pump pulse is studied here using a fully coherent approach based on experimental measurements and space charge calculations. The temporal dynamics of the valence band of a copper sample is recorded before and after an 800 nm laser pump excitation at a fluence of . The probe pulse is produced using a laboratory-based high-harmonics source delivering 25 fs pulses up to 100 eV photon energy. We extract the laser-heating contribution by comparing these measurements with space charge calculations based on particle-in-cell simulations of the pump and probe electron clouds mutual interaction on their way to the detector. The deduced picosecond dynamics associated to the electronic density of states shift is attributed to lattice changes with the help of hydrodynamic simulations including the two-temperature model.- 29 May 2024
- Published by American Physical Society (APS) in Physical Review B
- Vol. 109 (17) , 174311
Mitigating space charge in time-resolved photoelectron spectroscopy to study laser-heated copper dynamics in the high fluence regime
The performance of time-resolved photoelectron spectroscopy for the study of subpicosecond dynamics of laser-heated solids is often limited by space charge effects. The consequent shift and distortion of the photoelectron spectrum induced by electrons emitted by the ultrashort pump pulse is studied here using a fully coherent approach based on experimental measurements and space charge calculations. The temporal dynamics of the valence band of a copper sample is recorded before and after an 800 nm laser pump excitation at a fluence of . The probe pulse is produced using a laboratory-based high-harmonics source delivering 25 fs pulses up to 100 eV photon energy. We extract the laser-heating contribution by comparing these measurements with space charge calculations based on particle-in-cell simulations of the pump and probe electron clouds mutual interaction on their way to the detector. The deduced picosecond dynamics associated to the electronic density of states shift is attributed to lattice changes with the help of hydrodynamic simulations including the two-temperature model.- Open Access
- 23 April 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (16)
Shock compression experiments using the DiPOLE 100-X laser on the high energy density instrument at the European x-ray free electron laser: Quantitative structural analysis of liquid Sn
X-ray free electron laser (XFEL) sources coupled to high-power laser systems offer an avenue to study the structural dynamics of materials at extreme pressures and temperatures. The recent commissioning of the DiPOLE 100-X laser on the high energy density (HED) instrument at the European XFEL represents the state-of-the-art in combining x-ray diffraction with laser compression, allowing for compressed materials to be probed in unprecedented detail. Here, we report quantitative structural measurements of molten Sn compressed to 85(5) GPa and ∼3500 K. The capabilities of the HED instrument enable liquid density measurements with an uncertainty of ∼1% at conditions which are extremely challenging to reach via static compression methods. We discuss best practices for conducting liquid diffraction dynamic compression experiments and the necessary intensity corrections which allow for accurate quantitative analysis. We also provide a polyimide ablation pressure vs input laser energy for the DiPOLE 100-X drive laser which will serve future users of the HED instrument.
- 23 April 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (16)
Open AccessShock compression experiments using the DiPOLE 100-X laser on the high energy density instrument at the European x-ray free electron laser: Quantitative structural analysis of liquid Sn
X-ray free electron laser (XFEL) sources coupled to high-power laser systems offer an avenue to study the structural dynamics of materials at extreme pressures and temperatures. The recent commissioning of the DiPOLE 100-X laser on the high energy density (HED) instrument at the European XFEL represents the state-of-the-art in combining x-ray diffraction with laser compression, allowing for compressed materials to be probed in unprecedented detail. Here, we report quantitative structural measurements of molten Sn compressed to 85(5) GPa and ∼3500 K. The capabilities of the HED instrument enable liquid density measurements with an uncertainty of ∼1% at conditions which are extremely challenging to reach via static compression methods. We discuss best practices for conducting liquid diffraction dynamic compression experiments and the necessary intensity corrections which allow for accurate quantitative analysis. We also provide a polyimide ablation pressure vs input laser energy for the DiPOLE 100-X drive laser which will serve future users of the HED instrument.
- Open Access
- 1 September 2023
- Published by AIP Publishing in Structural Dynamics
- Vol. 10 (5) , 054502
Non-thermal structural transformation of diamond driven by x-rays
Intense x-ray pulses can cause the non-thermal structural transformation of diamond. At the SACLA XFEL facility, pump x-ray pulses triggered this phase transition, and probe x-ray pulses produced diffraction patterns. Time delays were observed from 0 to 250 fs, and the x-ray dose varied from 0.9 to 8.0 eV/atom. The intensity of the (111), (220), and (311) diffraction peaks decreased with time, indicating a disordering of the crystal lattice. From a Debye–Waller analysis, the rms atomic displacements perpendicular to the (111) planes were observed to be significantly larger than those perpendicular to the (220) or (311) planes. At a long time delay of 33 ms, graphite (002) diffraction indicates that graphitization did occur above a threshold dose of 1.2 eV/atom. These experimental results are in qualitative agreement with XTANT+ simulations using a hybrid model based on density-functional tight-binding molecular dynamics.
- 1 September 2023
- Published by AIP Publishing in Structural Dynamics
- Vol. 10 (5) , 054502
Open AccessNon-thermal structural transformation of diamond driven by x-rays
Intense x-ray pulses can cause the non-thermal structural transformation of diamond. At the SACLA XFEL facility, pump x-ray pulses triggered this phase transition, and probe x-ray pulses produced diffraction patterns. Time delays were observed from 0 to 250 fs, and the x-ray dose varied from 0.9 to 8.0 eV/atom. The intensity of the (111), (220), and (311) diffraction peaks decreased with time, indicating a disordering of the crystal lattice. From a Debye–Waller analysis, the rms atomic displacements perpendicular to the (111) planes were observed to be significantly larger than those perpendicular to the (220) or (311) planes. At a long time delay of 33 ms, graphite (002) diffraction indicates that graphitization did occur above a threshold dose of 1.2 eV/atom. These experimental results are in qualitative agreement with XTANT+ simulations using a hybrid model based on density-functional tight-binding molecular dynamics.