Richard J. Foster
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Richard J. Foster has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Ian M. Ward
4 shared publications- Ana-Maria Poenar
Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds
2 shared publications David Shelley
Leeds Teaching Hospitals NHS Trust
2 shared publications- Erica Dall’aRmellina
Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine University of Leeds Leeds UK
2 shared publications - Irvin Teh
University of Leeds
2 shared publications - Jurgen E. Schneider
Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine University of Leeds Leeds UK
2 shared publications
Latest Publications
- Open Access
Optimising Cardiac Diffusion Tensor Imaging In Vivo: More Directions or Averages?
Background: Cardiac diffusion tensor imaging (cDTI) is sensitive to imaging parameters including the number of unique diffusion encoding directions (ND) and number of repetitions (NR; analogous to number of signal averages or NSA). However, there is no clear guidance for optimising these parameters in the clinical setting. Methods: Spin echo cDTI data with 2 nd order motion compensated diffusion encoding gradients were acquired in ten healthy volunteers on a 3T MRI scanner with different diffusion encoding schemes in pseudo-randomised order. The data were subsampled to yield 96 acquisition schemes with 6 ≤ ND ≤ 30 and 33 ≤ total number of acquisitions (NA all ) ≤ 180. Stratified bootstrapping with robust fitting was performed to assess the precision and accuracy of each acquisition scheme. This was quantified across a mid-ventricular short-axis slice in terms of root mean squared difference (RMSD) with respect to the full reference dataset, and standard deviation (SD) across bootstrap samples respectively. Results: For the same acquisition time, the ND = 30 schemes had on average 48%, 40%, 34% and 34% lower RMSD and 6.2%, 7.4%, 10% and 5.6% lower SD in MD, FA, HA and E2A compared to the ND = 6 schemes. Given a fixed number of high b-value acquisitions, there was a trend towards lower RMSD and SD of MD and FA with increasing numbers of low b-value acquisitions. Higher NA all with longer acquisition times led to improved accuracy in all metrics whereby quadrupling NA all from 40 to 160 volumes led to a 21%, 40%, 13% and 4.5% reduction in RMSD of MD, FA, HA and E2A, averaged across six diffusion encoding schemes. Precision was also improved with a corresponding 53%, 50%, 52% and 36% reduction in SD. Conclusions: We observed that accuracy and precision were enhanced by (i) prioritising number of diffusion encoding directions over number of repetitions given a fixed acquisition time, (ii) acquiring sufficient low b-value data, (iii) using longer protocols where feasible. For clinically relevant protocols, our findings support the use of ND = 30 and NA b50 :NA b500 ≥ 1/3 for better accuracy and precision in cDTI parameters. These findings are intended to help guide protocol optimisation for harmonisation of cDTI.
Open AccessOptimising Cardiac Diffusion Tensor Imaging In Vivo: More Directions or Averages?
Background: Cardiac diffusion tensor imaging (cDTI) is sensitive to imaging parameters including the number of unique diffusion encoding directions (ND) and number of repetitions (NR; analogous to number of signal averages or NSA). However, there is no clear guidance for optimising these parameters in the clinical setting. Methods: Spin echo cDTI data with 2 nd order motion compensated diffusion encoding gradients were acquired in ten healthy volunteers on a 3T MRI scanner with different diffusion encoding schemes in pseudo-randomised order. The data were subsampled to yield 96 acquisition schemes with 6 ≤ ND ≤ 30 and 33 ≤ total number of acquisitions (NA all ) ≤ 180. Stratified bootstrapping with robust fitting was performed to assess the precision and accuracy of each acquisition scheme. This was quantified across a mid-ventricular short-axis slice in terms of root mean squared difference (RMSD) with respect to the full reference dataset, and standard deviation (SD) across bootstrap samples respectively. Results: For the same acquisition time, the ND = 30 schemes had on average 48%, 40%, 34% and 34% lower RMSD and 6.2%, 7.4%, 10% and 5.6% lower SD in MD, FA, HA and E2A compared to the ND = 6 schemes. Given a fixed number of high b-value acquisitions, there was a trend towards lower RMSD and SD of MD and FA with increasing numbers of low b-value acquisitions. Higher NA all with longer acquisition times led to improved accuracy in all metrics whereby quadrupling NA all from 40 to 160 volumes led to a 21%, 40%, 13% and 4.5% reduction in RMSD of MD, FA, HA and E2A, averaged across six diffusion encoding schemes. Precision was also improved with a corresponding 53%, 50%, 52% and 36% reduction in SD. Conclusions: We observed that accuracy and precision were enhanced by (i) prioritising number of diffusion encoding directions over number of repetitions given a fixed acquisition time, (ii) acquiring sufficient low b-value data, (iii) using longer protocols where feasible. For clinically relevant protocols, our findings support the use of ND = 30 and NA b50 :NA b500 ≥ 1/3 for better accuracy and precision in cDTI parameters. These findings are intended to help guide protocol optimisation for harmonisation of cDTI.
- Open Access
- 20 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 150-165
Cardiac q‐space trajectory imaging by motion‐compensated tensor‐valued diffusion encoding in human heart in vivo
Purpose: Tensor‐valued diffusion encoding can probe more specific features of tissue microstructure than what is available by conventional diffusion weighting. In this work, we investigate the technical feasibility of tensor‐valued diffusion encoding at high b‐values with q‐space trajectory imaging (QTI) analysis, in the human heart in vivo.Methods: Ten healthy volunteers were scanned on a 3T scanner. We designed time‐optimal gradient waveforms for tensor‐valued diffusion encoding (linear and planar) with second‐order motion compensation. Data were analyzed with QTI. Normal values and repeatability were investigated for the mean diffusivity (MD), fractional anisotropy (FA), microscopic FA (μFA), isotropic, anisotropic and total mean kurtosis (MKi, MKa, and MKt), and orientation coherence (Cc). A phantom, consisting of two fiber blocks at adjustable angles, was used to evaluate sensitivity of parameters to orientation dispersion and diffusion time.Results: QTI data in the left ventricular myocardium were MD = 1.62 ± 0.07 μm2/ms, FA = 0.31 ± 0.03, μFA = 0.43 ± 0.07, MKa = 0.20 ± 0.07, MKi = 0.13 ± 0.03, MKt = 0.33 ± 0.09, and Cc = 0.56 ± 0.22 (mean ± SD across subjects). Phantom experiments showed that FA depends on orientation dispersion, whereas μFA was insensitive to this effect.Conclusion: We demonstrated the first tensor‐valued diffusion encoding and QTI analysis in the heart in vivo, along with first measurements of myocardial μFA, MKi, MKa, and Cc. The methodology is technically feasible and provides promising novel biomarkers for myocardial tissue characterization.
- 20 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 150-165
Open AccessCardiac q‐space trajectory imaging by motion‐compensated tensor‐valued diffusion encoding in human heart in vivo
Purpose: Tensor‐valued diffusion encoding can probe more specific features of tissue microstructure than what is available by conventional diffusion weighting. In this work, we investigate the technical feasibility of tensor‐valued diffusion encoding at high b‐values with q‐space trajectory imaging (QTI) analysis, in the human heart in vivo.Methods: Ten healthy volunteers were scanned on a 3T scanner. We designed time‐optimal gradient waveforms for tensor‐valued diffusion encoding (linear and planar) with second‐order motion compensation. Data were analyzed with QTI. Normal values and repeatability were investigated for the mean diffusivity (MD), fractional anisotropy (FA), microscopic FA (μFA), isotropic, anisotropic and total mean kurtosis (MKi, MKa, and MKt), and orientation coherence (Cc). A phantom, consisting of two fiber blocks at adjustable angles, was used to evaluate sensitivity of parameters to orientation dispersion and diffusion time.Results: QTI data in the left ventricular myocardium were MD = 1.62 ± 0.07 μm2/ms, FA = 0.31 ± 0.03, μFA = 0.43 ± 0.07, MKa = 0.20 ± 0.07, MKi = 0.13 ± 0.03, MKt = 0.33 ± 0.09, and Cc = 0.56 ± 0.22 (mean ± SD across subjects). Phantom experiments showed that FA depends on orientation dispersion, whereas μFA was insensitive to this effect.Conclusion: We demonstrated the first tensor‐valued diffusion encoding and QTI analysis in the heart in vivo, along with first measurements of myocardial μFA, MKi, MKa, and Cc. The methodology is technically feasible and provides promising novel biomarkers for myocardial tissue characterization.
- 14 August 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (34) , 16050-16061
Nanoscale mechanics of microgel particles
Microgel particles are highly tuneable materials that are useful for a wide range of industrial applications, such as drug delivery, sensing, nanoactuation, emulsion stabilisation and use as cell substrates. Microgels have also been used as model systems investigating physical phenomena such as crystallization, glass-formation, jamming, ageing and complex flow behaviour. The responsiveness of microgel systems such as poly(N-isopropylacrylamide) (PNIPAm) to external stimuli has been established in fundamental investigations and in applications and recent work has begun to quantify the mechanics of individual particles. However little focus has been placed on determining their internal mechanical properties, which is likely to relate to their nonuniform internal structure. In this work we combine atomic force microscopy, force spectroscopy and dynamic light scattering to mechanically profile the internal structure of microgel particles in the size range of ∼100 nm, which is commonly used both in practical applications and in fundamental studies. Nanoindentation using thermally stable cantilevers allows us to determine the particle moduli and the deformation profiles during particle compression with increasing force, while peak force nanomechanical mapping (PF-QNM) AFM is used to capture high resolution images of the particles’ mechanical response. Combining these approaches with dynamic light scattering allows a quantitative profile of the particles’ internal elastic response to be determined. Our results provide clear evidence for a radial distribution in particle mechanical response with a softer outer “corona” and a stiffer particle core. We determine the particle moduli in the core and corona, using different force microscopy approaches, and find them to vary systematically both in the core (∼17–50 kPa) and at the outer periphery of the particles (∼3–40 kPa). Importantly, we find that highly crosslinked particles have equivalent moduli across their radial profile, reflecting their significantly lower radial heterogeneity. This ability to accurately and precisely probe microgel radial profiles has clear implications both for fundamental science and for industrial applications.
- 14 August 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (34) , 16050-16061
Nanoscale mechanics of microgel particles
Microgel particles are highly tuneable materials that are useful for a wide range of industrial applications, such as drug delivery, sensing, nanoactuation, emulsion stabilisation and use as cell substrates. Microgels have also been used as model systems investigating physical phenomena such as crystallization, glass-formation, jamming, ageing and complex flow behaviour. The responsiveness of microgel systems such as poly(N-isopropylacrylamide) (PNIPAm) to external stimuli has been established in fundamental investigations and in applications and recent work has begun to quantify the mechanics of individual particles. However little focus has been placed on determining their internal mechanical properties, which is likely to relate to their nonuniform internal structure. In this work we combine atomic force microscopy, force spectroscopy and dynamic light scattering to mechanically profile the internal structure of microgel particles in the size range of ∼100 nm, which is commonly used both in practical applications and in fundamental studies. Nanoindentation using thermally stable cantilevers allows us to determine the particle moduli and the deformation profiles during particle compression with increasing force, while peak force nanomechanical mapping (PF-QNM) AFM is used to capture high resolution images of the particles’ mechanical response. Combining these approaches with dynamic light scattering allows a quantitative profile of the particles’ internal elastic response to be determined. Our results provide clear evidence for a radial distribution in particle mechanical response with a softer outer “corona” and a stiffer particle core. We determine the particle moduli in the core and corona, using different force microscopy approaches, and find them to vary systematically both in the core (∼17–50 kPa) and at the outer periphery of the particles (∼3–40 kPa). Importantly, we find that highly crosslinked particles have equivalent moduli across their radial profile, reflecting their significantly lower radial heterogeneity. This ability to accurately and precisely probe microgel radial profiles has clear implications both for fundamental science and for industrial applications.
- Open Access
- 11 July 2018
- Published by The Royal Society in Royal Society Open Science
- Vol. 5 (7) , 180221
Imaging of nuclear magnetic resonance spin–lattice relaxation activation energy in cartilage
Samples of human and bovine cartilage have been examined using magnetic resonance imaging to determine the proton nuclear magnetic resonance spin–lattice relaxation time, T 1 , as a function of depth within through the cartilage tissue. T 1 was measured at five to seven temperatures between 8 and 38°C. From this, it is shown that the T 1 relaxation time is well described by Arrhenius-type behaviour and the activation energy of the relaxation process is quantified. The activation energy within the cartilage is approximately 11 ± 2 kJ mol −1 with this notably being less than that for both pure water (16.6 ± 0.4 kJ mol −1 ) and the phosphate-buffered solution in which the cartilage was immersed (14.7 ± 1.0 kJ mol −1 ). It is shown that this activation energy increases as a function of depth in the cartilage. It is known that cartilage composition varies with depth, and hence, these results have been interpreted in terms of the structure within the cartilage tissue and the association of the water with the macromolecular constituents of the cartilage.
- 11 July 2018
- Published by The Royal Society in Royal Society Open Science
- Vol. 5 (7) , 180221
Open AccessImaging of nuclear magnetic resonance spin–lattice relaxation activation energy in cartilage
Samples of human and bovine cartilage have been examined using magnetic resonance imaging to determine the proton nuclear magnetic resonance spin–lattice relaxation time, T 1 , as a function of depth within through the cartilage tissue. T 1 was measured at five to seven temperatures between 8 and 38°C. From this, it is shown that the T 1 relaxation time is well described by Arrhenius-type behaviour and the activation energy of the relaxation process is quantified. The activation energy within the cartilage is approximately 11 ± 2 kJ mol −1 with this notably being less than that for both pure water (16.6 ± 0.4 kJ mol −1 ) and the phosphate-buffered solution in which the cartilage was immersed (14.7 ± 1.0 kJ mol −1 ). It is shown that this activation energy increases as a function of depth in the cartilage. It is known that cartilage composition varies with depth, and hence, these results have been interpreted in terms of the structure within the cartilage tissue and the association of the water with the macromolecular constituents of the cartilage.
- Open Access
- 1 March 2016
- Published by The Royal Society in Royal Society Open Science
- Vol. 3 (3) , 150705
A nuclear magnetic resonance study of water in aggrecan solutions
Aggrecan, a highly charged macromolecule found in articular cartilage, was investigated in aqueous salt solutions with proton nuclear magnetic resonance. The longitudinal and transverse relaxation rates were determined at two different field strengths, 9.4 T and 0.5 T, for a range of temperatures and aggrecan concentrations. The diffusion coefficients of the water molecules were also measured as a function of temperature and aggrecan concentration, using a pulsed field gradient technique at 9.4 T. Assuming an Arrhenius relationship, the activation energies for the various relaxation processes and the translational motion of the water molecules were determined from temperature dependencies as a function of aggrecan concentration in the range 0–5.3% w/w. The longitudinal relaxation rate and inverse diffusion coefficient were approximately equally dependent on concentration and only increased by upto 20% from that of the salt solution. The transverse relaxation rate at high field demonstrated greatest concentration dependence, changing by an order of magnitude across the concentration range examined. We attribute this primarily to chemical exchange. Activation energies appeared to be approximately independent of aggrecan concentration, except for that of the low-field transverse relaxation rate, which decreased with concentration.
- 1 March 2016
- Published by The Royal Society in Royal Society Open Science
- Vol. 3 (3) , 150705
Open AccessA nuclear magnetic resonance study of water in aggrecan solutions
Aggrecan, a highly charged macromolecule found in articular cartilage, was investigated in aqueous salt solutions with proton nuclear magnetic resonance. The longitudinal and transverse relaxation rates were determined at two different field strengths, 9.4 T and 0.5 T, for a range of temperatures and aggrecan concentrations. The diffusion coefficients of the water molecules were also measured as a function of temperature and aggrecan concentration, using a pulsed field gradient technique at 9.4 T. Assuming an Arrhenius relationship, the activation energies for the various relaxation processes and the translational motion of the water molecules were determined from temperature dependencies as a function of aggrecan concentration in the range 0–5.3% w/w. The longitudinal relaxation rate and inverse diffusion coefficient were approximately equally dependent on concentration and only increased by upto 20% from that of the salt solution. The transverse relaxation rate at high field demonstrated greatest concentration dependence, changing by an order of magnitude across the concentration range examined. We attribute this primarily to chemical exchange. Activation energies appeared to be approximately independent of aggrecan concentration, except for that of the low-field transverse relaxation rate, which decreased with concentration.
- 1 March 2013
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 86 (1023) , 20120163
Quantitative parametric MRI of articular cartilage: a review of progress and open challenges
With increasing life expectancies and the desire to maintain active lifestyles well into old age, the impact of the debilitating disease osteoarthritis (OA) and its burden on healthcare services is mounting. Emerging regenerative therapies could deliver significant advances in the effective treatment of OA but rely upon the ability to identify the initial signs of tissue damage and will also benefit from quantitative assessment of tissue repair in vivo. Continued development in the field of quantitative MRI in recent years has seen the emergence of techniques able to probe the earliest biochemical changes linked with the onset of OA. Quantitative MRI measurements including T 1, T 2 and T 1ρ relaxometry, diffusion weighted imaging and magnetisation transfer have been studied and linked to the macromolecular structure of cartilage. Delayed gadolinium-enhanced MRI of cartilage, sodium MRI and glycosaminoglycan chemical exchange saturation transfer techniques are sensitive to depletion of cartilage glycosaminoglycans and may allow detection of the earliest stages of OA. We review these current and emerging techniques for the diagnosis of early OA, evaluate the progress that has been made towards their implementation in the clinic and identify future challenges in the field.
- 1 March 2013
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 86 (1023) , 20120163
Quantitative parametric MRI of articular cartilage: a review of progress and open challenges
With increasing life expectancies and the desire to maintain active lifestyles well into old age, the impact of the debilitating disease osteoarthritis (OA) and its burden on healthcare services is mounting. Emerging regenerative therapies could deliver significant advances in the effective treatment of OA but rely upon the ability to identify the initial signs of tissue damage and will also benefit from quantitative assessment of tissue repair in vivo. Continued development in the field of quantitative MRI in recent years has seen the emergence of techniques able to probe the earliest biochemical changes linked with the onset of OA. Quantitative MRI measurements including T 1, T 2 and T 1ρ relaxometry, diffusion weighted imaging and magnetisation transfer have been studied and linked to the macromolecular structure of cartilage. Delayed gadolinium-enhanced MRI of cartilage, sodium MRI and glycosaminoglycan chemical exchange saturation transfer techniques are sensitive to depletion of cartilage glycosaminoglycans and may allow detection of the earliest stages of OA. We review these current and emerging techniques for the diagnosis of early OA, evaluate the progress that has been made towards their implementation in the clinic and identify future challenges in the field.
- 28 February 2011
- Published by Elsevier in Composites Science and Technology
- Vol. 71 (4) , 461-465
The use of nano and micron-sized particles to enhance the interlayer adhesion in self-reinforced, single-polymer composites
- 28 February 2011
- Published by Elsevier in Composites Science and Technology
- Vol. 71 (4) , 461-465
The use of nano and micron-sized particles to enhance the interlayer adhesion in self-reinforced, single-polymer composites