Martin Janda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Martin Janda has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Christel Larsson
Associate Professor, Faculty of Odontology, Malmö University, Malmö, Sweden; and Associate Visiting Professor, Faculty of Dentistry, Department of Prosthetic Dentistry, Riga Stradins University, Riga, Latvia
2 shared publications- Ingrida Mischitz
Dental Research Assistant, Department of Dental Medicine and Oral Health, Medical University of Graz, Graz, Austria
2 shared publications Nikos Mattheos
Full Professor, Oral and Maxillofacial Surgery and Digital Implant Surgery Research Unit, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand; and Full Professor, Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
2 shared publications- Basel Mahardawi
Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
1 shared publication Daniel Kules
Undergraduate student, Faculty of Medicine, Institute of Odontology, Vilnius University, Vilnius, Lithuania
1 shared publication- Daniel Kules
Department of Periodontology, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
1 shared publication
Latest Publications
- 19 December 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (6) , e54-e63
Intraoral scan versus cone beam computed tomography to assess implant position: A systematic review and meta-analysis
- 19 December 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (6) , e54-e63
Intraoral scan versus cone beam computed tomography to assess implant position: A systematic review and meta-analysis
- 24 May 2024
- Published by Springer Nature in British Dental Journal
- Vol. 236 (10) , 765-771
Prosthetic design and choice of components for maintenance of optimal peri-implant health: a comprehensive review
Current research has identified features of the prosthetic design with potential to significantly impact the long-term health of peri-implant tissues, while the choice of prosthetic components is also shown to be critical in an effort to reduce long-term complications of implant therapy. Overcontouring of the prosthesis emergence profile has been associated with marginal bone loss, recession and peri-implantitis, while the mucosal emergence angle is shown to have a strong association with peri-implant tissue inflammation. Further elements of interest include convexity/concavity of the restoration, the prosthetic connection and the different geometric configurations of junctions, as well as the peri-implant tissue dimensions. With regards to implant components, the choice between original and third-party-manufactured components might come with implications, as differences in material and microgeometry might impact precision of fit and overall performance, potentially leading to complications. Scrutiny of the specifications and manufacturing is essential when third-party-manufactured components are considered.The aim of this narrative review was to summarise the current evidence with regards to the restorative features of the implant prosthesis and also the selection of prosthetic components which can have implications for the long-term success of the implant therapy. Furthermore, the review aimed at interpretating current scientific evidence into meaningful strategies and recommendations to implement in clinical practice of implant dentistry.
- 24 May 2024
- Published by Springer Nature in British Dental Journal
- Vol. 236 (10) , 765-771
Prosthetic design and choice of components for maintenance of optimal peri-implant health: a comprehensive review
Current research has identified features of the prosthetic design with potential to significantly impact the long-term health of peri-implant tissues, while the choice of prosthetic components is also shown to be critical in an effort to reduce long-term complications of implant therapy. Overcontouring of the prosthesis emergence profile has been associated with marginal bone loss, recession and peri-implantitis, while the mucosal emergence angle is shown to have a strong association with peri-implant tissue inflammation. Further elements of interest include convexity/concavity of the restoration, the prosthetic connection and the different geometric configurations of junctions, as well as the peri-implant tissue dimensions. With regards to implant components, the choice between original and third-party-manufactured components might come with implications, as differences in material and microgeometry might impact precision of fit and overall performance, potentially leading to complications. Scrutiny of the specifications and manufacturing is essential when third-party-manufactured components are considered.The aim of this narrative review was to summarise the current evidence with regards to the restorative features of the implant prosthesis and also the selection of prosthetic components which can have implications for the long-term success of the implant therapy. Furthermore, the review aimed at interpretating current scientific evidence into meaningful strategies and recommendations to implement in clinical practice of implant dentistry.
- Open Access
- 27 February 2024
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 133 (1) , 222-228
Misfit simulation on implant-supported prostheses with different combinations of engaging and nonengaging titanium bases: Part 3: A radiographic evaluation
- 27 February 2024
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 133 (1) , 222-228
Open AccessMisfit simulation on implant-supported prostheses with different combinations of engaging and nonengaging titanium bases: Part 3: A radiographic evaluation
- Open Access
- 15 August 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 131 (2) , 262-271
Misfit simulation on implant prostheses with different combinations of engaging and nonengaging titanium bases. Part 2: Screw resistance test
- 15 August 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 131 (2) , 262-271
Open AccessMisfit simulation on implant prostheses with different combinations of engaging and nonengaging titanium bases. Part 2: Screw resistance test
- 1 January 2019
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 121 (1) , 143-150
Differences in micromorphology of the implant–abutment junction for original and third-party abutments on a representative dental implant
- 1 January 2019
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 121 (1) , 143-150
Differences in micromorphology of the implant–abutment junction for original and third-party abutments on a representative dental implant