Zhanru Zhou has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Shenghong Huang
CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, University of Science and Technology of China, Hefei 230027, China
10 shared publications - Xiande Fang
Key Laboratory of Aircraft Environment Control and Life Support, MIIT, Nanjing University of Aeronautics and Astronautics, 29 Yudao St., Nanjing 210016, China
7 shared publications Bowen Zhao
4 shared publicationsMenglai Jiang
4 shared publicationsWeihua Wang
3 shared publicationsHang Li
2 shared publications
Latest Publications
- Open Access
- 2 October 2026
- Published by Elsevier in SSRN Electronic Journal
Thermomechanical Response and Fatigue Performance of Serrated W/Cu Interfaces with Different Geometries Under Cyclic High Heat Flux Loading
The geometric characteristics of W/Cu interfaces strongly influence thermomechanical deformation and fatigue damage under cyclic high heat flux (HHF) loading. This study investigates the effects of serration height and number on the thermomechanical response and fatigue performance of serrated W/Cu interfaces using benchmark HHF tests and parametric finite element analysis. Two serrated W/Cu divertor mockups were tested under cyclic HHF loading of 15 MW/m², and the measured temperature, strain, and displacement responses were used to characterize the geometry-dependent behavior. Parametric simulations were then performed for serration heights of 0.5–2.0 mm and serration numbers of 3–18 under 15 and 20 MW/m² heat fluxes. Increasing the serration height or number generally reduced the tungsten temperature rise and improved thermal uniformity, but also strengthened geometric constraint and increased local bending and multiaxial stress near the serration roots. Consequently, the predicted fatigue life exhibited a non-monotonic dependence on serration geometry, reflecting the competition between thermal benefits and mechanical constraints. The finer experimental configuration exhibited a smoother cross-interface displacement transition and an approximately 19.8% higher predicted fatigue life than the coarser configuration. Within the investigated parameter range, serration heights of 1.0–1.5 mm exhibited relatively favorable thermomechanical performance, suggesting a suitable range for balancing thermal response and mechanical constraint in serrated W/Cu interfaces.
- 2 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThermomechanical Response and Fatigue Performance of Serrated W/Cu Interfaces with Different Geometries Under Cyclic High Heat Flux Loading
The geometric characteristics of W/Cu interfaces strongly influence thermomechanical deformation and fatigue damage under cyclic high heat flux (HHF) loading. This study investigates the effects of serration height and number on the thermomechanical response and fatigue performance of serrated W/Cu interfaces using benchmark HHF tests and parametric finite element analysis. Two serrated W/Cu divertor mockups were tested under cyclic HHF loading of 15 MW/m², and the measured temperature, strain, and displacement responses were used to characterize the geometry-dependent behavior. Parametric simulations were then performed for serration heights of 0.5–2.0 mm and serration numbers of 3–18 under 15 and 20 MW/m² heat fluxes. Increasing the serration height or number generally reduced the tungsten temperature rise and improved thermal uniformity, but also strengthened geometric constraint and increased local bending and multiaxial stress near the serration roots. Consequently, the predicted fatigue life exhibited a non-monotonic dependence on serration geometry, reflecting the competition between thermal benefits and mechanical constraints. The finer experimental configuration exhibited a smoother cross-interface displacement transition and an approximately 19.8% higher predicted fatigue life than the coarser configuration. Within the investigated parameter range, serration heights of 1.0–1.5 mm exhibited relatively favorable thermomechanical performance, suggesting a suitable range for balancing thermal response and mechanical constraint in serrated W/Cu interfaces.
- Open Access
- 2 October 2026
- Published by Elsevier in SSRN Electronic Journal
Riemann-TLSPH Simulation of Turbulent-Noise-Induced Vibration Response of an Inlet Compression Panel under High-Mach-Number Flow Conditions
During the operation of high-Mach-number vehicles, the inlet compression panel is subjected to broadband turbulent-noise excitation, which may induce complex structural vibration responses and increase the risk of fatigue damage. To investigate the noise-induced vibration of inlet compression panels under external flow excitation, this study establishes a one-way aerodynamic-load/structural-response analysis framework by integrating the Universal Discretizing and Synthesizing Random Flow Generation (UDSRFG) method with the Total Lagrangian-Riemann Smoothed Particle Hydrodynamics (Riemann-TLSPH) method. In this framework, broadband turbulent pressure loads are reconstructed under the corresponding flow conditions and then mapped onto the SPH structural model as external excitation. The results show that the inlet compression panel undergoes random vibration under turbulent-noise excitation, with a broadband spectrum and clear energy concentration within the 1-4 kHz frequency band. Compared with the pressure-load input reconstructed from the nine experimental measurement points, for which the maximum RMS acceleration-level deviation reaches 11.14 dB, the UDSRFG-derived 4×4 virtual sampling-point load representation reduces the maximum absolute deviation to 5.89 dB, with the deviations at all nine acceleration measurement points remaining below 6 dB. This indicates that the predicted vibration response is sensitive to the spatial representation of the pressure excitation and that the UDSRFG-based load representation improves agreement with the experimental data. Further frequency-domain decomposition identifies distinct structural response characteristics near 2 and 3.4 kHz. The response near 2 kHz exhibits stronger spatial localization and modal coherence, whereas that near 3.4 kHz shows a substantially larger transverse velocity amplitude and more complex spatial organization. These frequency-dependent patterns provide a basis for identifying response bands and panel regions requiring priority attention in vibration monitoring and fatigue-oriented structural assessment. The proposed integrated framework provides numerical support for vibration-response prediction and safety assessment of thin-walled structures in high-Mach-number vehicles.
- 2 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessRiemann-TLSPH Simulation of Turbulent-Noise-Induced Vibration Response of an Inlet Compression Panel under High-Mach-Number Flow Conditions
During the operation of high-Mach-number vehicles, the inlet compression panel is subjected to broadband turbulent-noise excitation, which may induce complex structural vibration responses and increase the risk of fatigue damage. To investigate the noise-induced vibration of inlet compression panels under external flow excitation, this study establishes a one-way aerodynamic-load/structural-response analysis framework by integrating the Universal Discretizing and Synthesizing Random Flow Generation (UDSRFG) method with the Total Lagrangian-Riemann Smoothed Particle Hydrodynamics (Riemann-TLSPH) method. In this framework, broadband turbulent pressure loads are reconstructed under the corresponding flow conditions and then mapped onto the SPH structural model as external excitation. The results show that the inlet compression panel undergoes random vibration under turbulent-noise excitation, with a broadband spectrum and clear energy concentration within the 1-4 kHz frequency band. Compared with the pressure-load input reconstructed from the nine experimental measurement points, for which the maximum RMS acceleration-level deviation reaches 11.14 dB, the UDSRFG-derived 4×4 virtual sampling-point load representation reduces the maximum absolute deviation to 5.89 dB, with the deviations at all nine acceleration measurement points remaining below 6 dB. This indicates that the predicted vibration response is sensitive to the spatial representation of the pressure excitation and that the UDSRFG-based load representation improves agreement with the experimental data. Further frequency-domain decomposition identifies distinct structural response characteristics near 2 and 3.4 kHz. The response near 2 kHz exhibits stronger spatial localization and modal coherence, whereas that near 3.4 kHz shows a substantially larger transverse velocity amplitude and more complex spatial organization. These frequency-dependent patterns provide a basis for identifying response bands and panel regions requiring priority attention in vibration monitoring and fatigue-oriented structural assessment. The proposed integrated framework provides numerical support for vibration-response prediction and safety assessment of thin-walled structures in high-Mach-number vehicles.
- Open Access
- 1 April 2026
- Published by Elsevier in SSRN Electronic Journal
Heat transfer enhancement of supercritical carbon dioxide in a new elliptical channel with bump-like boundary structures
Cooling with supercritical CO₂ (sCO₂) under one-sided high heat flux is promising for compact thermal management. This study proposes an additively manufacturable elliptical cooling channel featuring near-wall bump-like protrusions on the heated side to promote heat transfer. Simulations at a pressure of 10 MPa, a velocity of 5 m/s, an inlet temperature of 303 K, and a heat flux of 500 kW/m² show a 23 K reduction in wall temperature compared with a smooth ellipse. One-sided heating experiments were then performed at 35 operating points with pressures of 7.7–9.3 MPa, velocities of 1.2–9.9 m/s, inlet temperatures of 305–313.7 K, and heat fluxes of 195.6–471 kW/m². The bump-like channel provides higher heat transfer coefficients, about 11–26 kW/(m²K) versus about 6.9–8.1 kW/(m²K) for the smooth channel, corresponding to an overall enhancement of roughly 1.8–3.4 times, with the largest gains occurring near 400 kW/m². Evaluating 25 published sCO₂ correlations on this database shows typical mean absolute deviations (MAD) above 40%. A new correlation is developed for both geometries using six dimensionless parameters. It reaches a MAD of 4.9% for the smooth channel and 8.2% for the bump-like channel, with 6.2% overall. This provides a practical design path that couples geometry-enhanced heat transfer with reliable performance prediction for sCO₂ cooling channels.
- 1 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHeat transfer enhancement of supercritical carbon dioxide in a new elliptical channel with bump-like boundary structures
Cooling with supercritical CO₂ (sCO₂) under one-sided high heat flux is promising for compact thermal management. This study proposes an additively manufacturable elliptical cooling channel featuring near-wall bump-like protrusions on the heated side to promote heat transfer. Simulations at a pressure of 10 MPa, a velocity of 5 m/s, an inlet temperature of 303 K, and a heat flux of 500 kW/m² show a 23 K reduction in wall temperature compared with a smooth ellipse. One-sided heating experiments were then performed at 35 operating points with pressures of 7.7–9.3 MPa, velocities of 1.2–9.9 m/s, inlet temperatures of 305–313.7 K, and heat fluxes of 195.6–471 kW/m². The bump-like channel provides higher heat transfer coefficients, about 11–26 kW/(m²K) versus about 6.9–8.1 kW/(m²K) for the smooth channel, corresponding to an overall enhancement of roughly 1.8–3.4 times, with the largest gains occurring near 400 kW/m². Evaluating 25 published sCO₂ correlations on this database shows typical mean absolute deviations (MAD) above 40%. A new correlation is developed for both geometries using six dimensionless parameters. It reaches a MAD of 4.9% for the smooth channel and 8.2% for the bump-like channel, with 6.2% overall. This provides a practical design path that couples geometry-enhanced heat transfer with reliable performance prediction for sCO₂ cooling channels.
- Open Access
- 25 March 2026
- Published by Elsevier in SSRN Electronic Journal
Validation of a Laser Speckle–Based DIC Method for Strain Measurement on Divertor Plasma-Facing Surfaces Under High Heat Flux Conditions
Measuring surface strain on divertor targets under high heat flux (HHF) is critical for fusion reactor reliability, yet conventional physical speckle methods fail due to coating ablation or surface damage. This study presents a laser speckle–based digital image correlation (LS-DIC) method that eliminates artificial markings by leveraging intrinsic surface roughness to generate stable speckle patterns under coherent illumination. A Multi-Factor Fusion Index for Laser Speckle Sequences (MFFIseq) is introduced to optimize imaging and thermal loading parameters, ensuring high-quality image sequences under HHF conditions. Experiments on tungsten divertor targets at 2, 5, and 10 MW/m2 show that LS-DIC successfully captures full-field strain evolution throughout the entire loading cycle. The method demonstrates excellent agreement with physical markers (relative errors: 1.46%–2.96%) and finite element simulations (deviation: ~4.03%). This work provides a non-destructive, high-fidelity approach for direct strain measurement on plasma-facing components under extreme thermal loads, offering robust experimental validation for fusion applications.
- 25 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessValidation of a Laser Speckle–Based DIC Method for Strain Measurement on Divertor Plasma-Facing Surfaces Under High Heat Flux Conditions
Measuring surface strain on divertor targets under high heat flux (HHF) is critical for fusion reactor reliability, yet conventional physical speckle methods fail due to coating ablation or surface damage. This study presents a laser speckle–based digital image correlation (LS-DIC) method that eliminates artificial markings by leveraging intrinsic surface roughness to generate stable speckle patterns under coherent illumination. A Multi-Factor Fusion Index for Laser Speckle Sequences (MFFIseq) is introduced to optimize imaging and thermal loading parameters, ensuring high-quality image sequences under HHF conditions. Experiments on tungsten divertor targets at 2, 5, and 10 MW/m2 show that LS-DIC successfully captures full-field strain evolution throughout the entire loading cycle. The method demonstrates excellent agreement with physical markers (relative errors: 1.46%–2.96%) and finite element simulations (deviation: ~4.03%). This work provides a non-destructive, high-fidelity approach for direct strain measurement on plasma-facing components under extreme thermal loads, offering robust experimental validation for fusion applications.
- Open Access
- 3 February 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (3)
Enhanced thermal fatigue resistance of W/Cu divertor components via serrated interface design: Experimental and numerical insights
Divertors constructed primarily from tungsten–copper (W/Cu) composites are essential components in magnetically confined fusion reactors, where they are subjected to extreme thermal loads. However, the W/Cu interface is particularly susceptible to fatigue-induced fracture under high heat flux conditions. Modifying the interfacial configuration between tungsten and copper presents a promising approach to enhance the fatigue life of divertors. This study introduces a millimetre-scale serrated W/Cu interfacial design with finite element simulations and compares the fatigue performance of planar and serrated interfaces under cyclic thermal loading, with a focus on their thermomechanical behavior and failure mechanisms. The high heat flux experiments with digital image correlation (DIC) and infrared (IR) thermography demonstrates that the serrated interface enhances fatigue life by about 5 times compared to the planar configuration under cyclic loading at 10 MW/m². After 1300 thermal cycles, metallographic observations reveal that the planar interface experiences severe shear-driven fracture, while the serrated interface maintains structural integrity with minimal damage. This enhancement in fatigue performance is attributed to the serrated geometry, which redistributes shear strain, concentrates deformation at serration tips, and induces compressive strains that suppress crack propagation. These findings provide the practical and economical optimization of W/Cu interfacial structures, supporting the development of more robust divertors for fusion reactors operating under more extreme thermal environments.
- 3 February 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (3)
Open AccessEnhanced thermal fatigue resistance of W/Cu divertor components via serrated interface design: Experimental and numerical insights
Divertors constructed primarily from tungsten–copper (W/Cu) composites are essential components in magnetically confined fusion reactors, where they are subjected to extreme thermal loads. However, the W/Cu interface is particularly susceptible to fatigue-induced fracture under high heat flux conditions. Modifying the interfacial configuration between tungsten and copper presents a promising approach to enhance the fatigue life of divertors. This study introduces a millimetre-scale serrated W/Cu interfacial design with finite element simulations and compares the fatigue performance of planar and serrated interfaces under cyclic thermal loading, with a focus on their thermomechanical behavior and failure mechanisms. The high heat flux experiments with digital image correlation (DIC) and infrared (IR) thermography demonstrates that the serrated interface enhances fatigue life by about 5 times compared to the planar configuration under cyclic loading at 10 MW/m². After 1300 thermal cycles, metallographic observations reveal that the planar interface experiences severe shear-driven fracture, while the serrated interface maintains structural integrity with minimal damage. This enhancement in fatigue performance is attributed to the serrated geometry, which redistributes shear strain, concentrates deformation at serration tips, and induces compressive strains that suppress crack propagation. These findings provide the practical and economical optimization of W/Cu interfacial structures, supporting the development of more robust divertors for fusion reactors operating under more extreme thermal environments.
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (3)
Mechanism of bubble nucleation and growth during nucleate boiling on microcavity surfaces
The enhancement of heat transfer using engineered microstructured surfaces holds significant potential for applications in high heat flux components. To investigate the impact of microstructure scale on bubble nucleation and growth at the microscale, three types of microcavity surfaces, each with an identical surface area-to-volume ratio, were fabricated on monocrystalline silicon plates. The nucleation and growth of bubbles on these microstructured surfaces, as well as on smooth surfaces, were observed during pool boiling experiments using a metallurgical microscope and high-speed photography with de-ionized water. The experimental results indicate that both the temperature and diameter of nucleated bubbles are significantly influenced by the scale of the microstructure. These observations are consistent with predictions from the Young–Laplace equation, confirming that the scale of the microstructure plays a pivotal role in enhancing boiling heat transfer. However, existing bubble growth models exhibit discrepancies when compared to the experimental data. To address this, a new bubble growth model, based on energy conservation principles and microstructure characterization parameters, is proposed. This model accurately predicts bubble growth behavior on microstructured surfaces, with a mean absolute deviation of 11.7%. The microstructure enhances heat transfer both from the wall to the bubble and from the wall to the adjacent superheated liquid layer. The expansion of the vapor/liquid interface is an important factor in the growth of bubble diameter on microstructured surfaces.
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (3)
Mechanism of bubble nucleation and growth during nucleate boiling on microcavity surfaces
The enhancement of heat transfer using engineered microstructured surfaces holds significant potential for applications in high heat flux components. To investigate the impact of microstructure scale on bubble nucleation and growth at the microscale, three types of microcavity surfaces, each with an identical surface area-to-volume ratio, were fabricated on monocrystalline silicon plates. The nucleation and growth of bubbles on these microstructured surfaces, as well as on smooth surfaces, were observed during pool boiling experiments using a metallurgical microscope and high-speed photography with de-ionized water. The experimental results indicate that both the temperature and diameter of nucleated bubbles are significantly influenced by the scale of the microstructure. These observations are consistent with predictions from the Young–Laplace equation, confirming that the scale of the microstructure plays a pivotal role in enhancing boiling heat transfer. However, existing bubble growth models exhibit discrepancies when compared to the experimental data. To address this, a new bubble growth model, based on energy conservation principles and microstructure characterization parameters, is proposed. This model accurately predicts bubble growth behavior on microstructured surfaces, with a mean absolute deviation of 11.7%. The microstructure enhances heat transfer both from the wall to the bubble and from the wall to the adjacent superheated liquid layer. The expansion of the vapor/liquid interface is an important factor in the growth of bubble diameter on microstructured surfaces.
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (2)
Visual observations of bubble growth and nucleation site density on microstructured surfaces during flow boiling in a single microchannel
Recent studies have shown that modified microstructures can significantly enhance boiling heat transfer performance. However, the unclear mechanisms of boiling on microstructured surfaces present challenges in optimizing heat transfer through microstructural modulation. To investigate the influence of the microstructure on bubble dynamics, visual observations of bubble behavior on microstructured surfaces during flow boiling were carried out with a metallurgical microscope and high-speed photography. The experiments focused on bubble growth on a smooth surface with nine microcavities and nucleation site density on a microstructured surface during flow boiling under various conditions (Reynolds numbers of 17.5, 34.9, and 87.4, and heat fluxes of 50, 100, and 150 kW/m2). The observations reveal that heat flux strongly promotes bubble growth and nucleation site density when bubble sizes remain below 200 μm. Based on 114 experimental data points, ten existing bubble growth models were assessed and found to inadequately predict the growth of micrometer-scale bubbles. A new dimensionless model, with a mean absolute deviation of 9.65%, was developed by integrating heat transfer, fluid flow, interface dynamics, and temporal variations, and it can be adapted for similar experiments. Additionally, bubble numbers peak with active nucleation and decrease due to coalescence, influenced by velocity and heat flux. Higher heat fluxes promote bubble growth and coalescence, whereas the flow velocity has a dual effect on bubble growth and nucleation site density. The results suggest that optimizing the flow velocity on microstructured surfaces based on bubble behavior can effectively enhance the heat transfer performance, providing guidance for future thermal management innovations.
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (2)
Visual observations of bubble growth and nucleation site density on microstructured surfaces during flow boiling in a single microchannel
Recent studies have shown that modified microstructures can significantly enhance boiling heat transfer performance. However, the unclear mechanisms of boiling on microstructured surfaces present challenges in optimizing heat transfer through microstructural modulation. To investigate the influence of the microstructure on bubble dynamics, visual observations of bubble behavior on microstructured surfaces during flow boiling were carried out with a metallurgical microscope and high-speed photography. The experiments focused on bubble growth on a smooth surface with nine microcavities and nucleation site density on a microstructured surface during flow boiling under various conditions (Reynolds numbers of 17.5, 34.9, and 87.4, and heat fluxes of 50, 100, and 150 kW/m2). The observations reveal that heat flux strongly promotes bubble growth and nucleation site density when bubble sizes remain below 200 μm. Based on 114 experimental data points, ten existing bubble growth models were assessed and found to inadequately predict the growth of micrometer-scale bubbles. A new dimensionless model, with a mean absolute deviation of 9.65%, was developed by integrating heat transfer, fluid flow, interface dynamics, and temporal variations, and it can be adapted for similar experiments. Additionally, bubble numbers peak with active nucleation and decrease due to coalescence, influenced by velocity and heat flux. Higher heat fluxes promote bubble growth and coalescence, whereas the flow velocity has a dual effect on bubble growth and nucleation site density. The results suggest that optimizing the flow velocity on microstructured surfaces based on bubble behavior can effectively enhance the heat transfer performance, providing guidance for future thermal management innovations.
- 1 April 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (4)
An improved wall boiling model for numerical simulation of subcooled flow boiling on a new hybrid micro/nanostructured surface
Previous studies have demonstrated that micro/nanostructured surfaces have great potential for heat transfer enhancement. However, simulating subcooled flow boiling on such surfaces is difficult owing to the lack of proper bubble characteristic parameter models, because most models used in flow boiling simulations were developed based on smooth surface conditions, which may limit their applications in engineering design. In this study, we improved upon one validated bubble characteristic parameter model suitable for subcooled flow boiling on smooth surfaces to adapt to the new hybrid micro/nanostructured surfaces proposed by Huang et al. [“Experimental investigation of a new hybrid structured surface for subcooled flow boiling heat transfer enhancement,” Appl. Therm. Eng. 192, 116929 (2021)]. The new bubble characteristic parameter model incorporates both basic correction terms to account for boiling bubble behaviors and ad hoc parameters to account for other unknown effects. Through sensitivity analysis and detailed calibration, the model was simplified to a set of correlations and only one constant parameter. With this improved model, subcooled flow boiling heat transfer simulations were conducted for three target surface specifications under conditions of 4–10 MW/m2 incident heat flux and 1–5 m/s flow velocity and the related heat-transfer mechanisms were further compared and discussed. The maximum error between the simulation and experimental results remains less than 3.5%, indicating that the established model has considerable accuracy in predicting the heat transfer performance for this type of micro/nanostructured surface in high-heat-flux engineering design applications. The heat transfer enhancement for subcooled flow boiling on this type of hybrid micro/nanostructured surface is greatly beneficial owing to its proper organization of convection, evaporation, and quenching heat transfer.
- 1 April 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (4)
An improved wall boiling model for numerical simulation of subcooled flow boiling on a new hybrid micro/nanostructured surface
Previous studies have demonstrated that micro/nanostructured surfaces have great potential for heat transfer enhancement. However, simulating subcooled flow boiling on such surfaces is difficult owing to the lack of proper bubble characteristic parameter models, because most models used in flow boiling simulations were developed based on smooth surface conditions, which may limit their applications in engineering design. In this study, we improved upon one validated bubble characteristic parameter model suitable for subcooled flow boiling on smooth surfaces to adapt to the new hybrid micro/nanostructured surfaces proposed by Huang et al. [“Experimental investigation of a new hybrid structured surface for subcooled flow boiling heat transfer enhancement,” Appl. Therm. Eng. 192, 116929 (2021)]. The new bubble characteristic parameter model incorporates both basic correction terms to account for boiling bubble behaviors and ad hoc parameters to account for other unknown effects. Through sensitivity analysis and detailed calibration, the model was simplified to a set of correlations and only one constant parameter. With this improved model, subcooled flow boiling heat transfer simulations were conducted for three target surface specifications under conditions of 4–10 MW/m2 incident heat flux and 1–5 m/s flow velocity and the related heat-transfer mechanisms were further compared and discussed. The maximum error between the simulation and experimental results remains less than 3.5%, indicating that the established model has considerable accuracy in predicting the heat transfer performance for this type of micro/nanostructured surface in high-heat-flux engineering design applications. The heat transfer enhancement for subcooled flow boiling on this type of hybrid micro/nanostructured surface is greatly beneficial owing to its proper organization of convection, evaporation, and quenching heat transfer.
- Open Access
- 1 February 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (2)
New correlation of the subcooled flow boiling heat transfer coefficient for hybrid micro/nanostructured surfaces with high heat flux incidence
Surfaces manipulated with micro/nanostructures have great potential for imparting high heat removal capacity to heat transfer equipment under high heat flux incidence. However, few correlations of heat transfer coefficients have been developed based on high-heat flux experiments of subcooled flow boiling with nano- and microstructured surfaces, which may limit the further application of this technique in industrial engineering. Aiming at recently developed hybrid micro/nanostructured surfaces for subcooled flow boiling performance enhancement, a series of experiments with different surface structure scale specifications, flow conditions, and heat flux incidence ranges were conducted. In total, 530 experimental data points were obtained with heat fluxes ranging from 3.4 to 13.1 MW/m2, pressures from 0.5 to 1.5 MPa, liquid velocities from 1 to 5 m/s, inlet temperatures from 303.15 to 323.15 K, and structured surfaces with wire apertures of 250, 125, and 58 μm. The 28 existing correlations based on smooth surfaces and structured surfaces failed to predict these experimental data. A new enhancement factor-type correlation model, which included four dimensionless numbers that specialized in the effects of the span dimension and depth dimension of the target hybrid micro/nanostructured surfaces, was developed and shown to have good prediction accuracy and a considerable degree of application adaptability, with a mean absolute deviation of 5.7%.
- 1 February 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (2)
Open AccessNew correlation of the subcooled flow boiling heat transfer coefficient for hybrid micro/nanostructured surfaces with high heat flux incidence
Surfaces manipulated with micro/nanostructures have great potential for imparting high heat removal capacity to heat transfer equipment under high heat flux incidence. However, few correlations of heat transfer coefficients have been developed based on high-heat flux experiments of subcooled flow boiling with nano- and microstructured surfaces, which may limit the further application of this technique in industrial engineering. Aiming at recently developed hybrid micro/nanostructured surfaces for subcooled flow boiling performance enhancement, a series of experiments with different surface structure scale specifications, flow conditions, and heat flux incidence ranges were conducted. In total, 530 experimental data points were obtained with heat fluxes ranging from 3.4 to 13.1 MW/m2, pressures from 0.5 to 1.5 MPa, liquid velocities from 1 to 5 m/s, inlet temperatures from 303.15 to 323.15 K, and structured surfaces with wire apertures of 250, 125, and 58 μm. The 28 existing correlations based on smooth surfaces and structured surfaces failed to predict these experimental data. A new enhancement factor-type correlation model, which included four dimensionless numbers that specialized in the effects of the span dimension and depth dimension of the target hybrid micro/nanostructured surfaces, was developed and shown to have good prediction accuracy and a considerable degree of application adaptability, with a mean absolute deviation of 5.7%.