BZBanghe Zhu

Banghe Zhu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Banghe Zhu has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Review of Image Sensors Used in Near-Infrared and Shortwave Infrared Fluorescence Imaging

    by Banghe Zhu, Henry Jonathan

    To translate near-infrared (NIR) and shortwave infrared (SWIR) fluorescence imaging into the clinic, the paired imaging device needs to detect trace doses of fluorescent imaging agents. Except for the filtration scheme and excitation light source, the image sensor used will finally determine the detection limitations of NIR and SWIR fluorescence imaging systems. In this review, we investigate the current state-of-the-art image sensors used in NIR and SWIR fluorescence imaging systems and discuss the advantages and limitations of their characteristics, such as readout architecture and noise factors. Finally, the imaging performance of these image sensors is evaluated and compared.


  • Near-Infrared Fluorescence Tomography and Imaging of Ventricular Cerebrospinal Fluid Flow and Extracranial Outflow in Non-Human Primates

    by Banghe Zhu, Jonathan Hendricks, Janelle E. Morton, John C. Rasmussen, Christopher Janssen, Manish N. Shah, Eva Marie Sevick-Muraca

    The role of the lymphatics in the clearance of cerebrospinal fluid (CSF) from the brain has been implicated in multiple neurodegenerative conditions. In premature infants, intraventricular hemorrhage causes increased CSF production and, if clearance is impeded, hydrocephalus and severe developmental disabilities can result. In this work, we developed and deployed near-infrared fluorescence (NIRF) tomography and imaging to assess CSF ventricular dynamics and extracranial outflow in similarly sized, intact non-human primates (NHP) following microdose of indocyanine green (ICG) administered to the right lateral ventricle. Fluorescence optical tomography measurements were made by delivering ~10 mW of 785 nm light to the scalp by sequential illumination of 8 fiber optics and imaging the 830 nm emission light collected from 22 fibers using a gallium arsenide intensified, charge coupled device. Acquisition times were 16 seconds. Image reconstruction used the diffusion approximation and hard-priors obtained from MRI to enable dynamic mapping of ICG-laden CSF ventricular dynamics and drainage into the subarachnoid space (SAS) of NHPs. Subsequent, planar NIRF imaging of the scalp confirmed extracranial efflux into SAS and abdominal imaging showed ICG clearance through the hepatobiliary system. Necropsy confirmed imaging results and showed that deep cervical lymph nodes were the routes of extracranial CSF egress. The results confirm the ability to use trace doses of ICG to monitor ventricular CSF dynamics and extracranial outflow in NHP. The techniques may also be feasible for similarly-sized infants and children who may suffer impairment of CSF outflow due to intraventricular hemorrhage.


  • Cap-Based Transcranial Optical Tomography in an Awake Infant

    by Banghe Zhu, Eva M. Sevick-Muraca, Ryan D. Nguyen, Manish N. Shah

    Although Blood Oxygenation Level Dependent (BOLD) functional MRI (fMRI) is widely used to examine brain function in adults, the need for general anesthesia limits its practical utility in infants and small children. Functional Near-Infrared Spectroscopy - Diffuse Optical Tomography (fNIRS-DOT) imaging promises to be an alternative brain network imaging technique. Yet current versions of continuous-wave fNIRS-DOT systems are restricted to the cortical surface measurements and do not probe deep structures that are frequently injured especially in premature infants. Herein we report a transcranial near infrared optical imaging system, called Cap-based Transcranial Optical Tomography (CTOT) able to image whole brain hemodynamic activity with 3 seconds of data acquisition time. We show the system is capable of whole brain oxygenation mapping in an awake child, and that tomographically reconstructed static CTOT-derived oxy- and deoxygenated blood volumes are spatially correlated with the time-averaged BOLD fMRI volumes. By removing time bottlenecks in the current system, dynamic CTOT mapping should be possible, which would then enable evaluation of functional connectivity in awake infants.


  • Comparison of NIR Versus SWIR Fluorescence Image Device Performance Using Working Standards Calibrated With SI Units

    by Banghe Zhu, Sunkuk Kwon, John C. Rasmussen, Maritoni Litorja, Eva M. Sevick-Muraca

    Recently, fluorescence imaging using shortwave infrared light (SWIR, 1,000-2,000 nm) has been proposed as having advantage over conventional near-infrared fluorescence (NIRF) imaging due to the reduced tissue scattering, negligible autofluorescence, comparable tissue absorption, and the discovery that indocyanine green (ICG), used clinically as a NIRF contrast agent, also has fluorescence emission in SWIR regime. Images of ICG in small animals acquired by commercial Si-based and InGaAs-based imaging cameras have been qualitatively compared, however the lack of working standards to quantify performance of these imaging systems limits quantitative comparison. Without quantification using a traceable in vitro test, clinical adoption of rapidly evolving advances in both NIRF and SWIR imaging devices will become limited. In this work, we developed an ICG based fluorescent solid working standard calibrated with SI units (mW${^\centerdot }$ cm$^{-{2}} {^\centerdot }$ sr -1 ) for quantification of measurement sensitivity of Si, GaAs-intensified Si, and InGaAs based camera systems, their signal-to-noise ratio (SNR), and contrast in non-clinical tests. In addition, we present small animal and large animal imaging with ICG for qualitative comparison of the same SWIR fluorescence and NIRF imaging systems. Results suggest that SWIR fluorescence imaging of ICG may have superior resolution in small animal imaging compared to NIRF imaging, but lack of measurement sensitivity, SNR, contrast, as well as water absorption limits deep penetration in large animals.


  • The Lymphatics in Early Venous and Peripheral Arterial Disease

    by John Rasmussen, Banghe Zhu, Aaron Sahihi, Melissa B. Aldrich, Stuart Harlin, Kristofer M. Charlton-Ouw, Caroline E. Fife, Thomas O'Donnell, Eva M. Sevick-Muraca

  • Open Access

    Near-Infrared Fluorescence-Enhanced Optical Tomography

    by Banghe Zhu, Anuradha Godavarty

    Fluorescence-enhanced optical imaging using near-infrared (NIR) light developed forin vivomolecular targeting and reporting of cancer provides promising opportunities for diagnostic imaging. The current state of the art of NIR fluorescence-enhanced optical tomography is reviewed in the context of the principle of fluorescence, the different measurement schemes employed, and the mathematical tools established to tomographically reconstruct the fluorescence optical properties in various tissue domains. Finally, we discuss the recent advances in forward modeling and distributed memory parallel computation to provide robust, accurate, and fast fluorescence-enhanced optical tomography.


  • Determining the Performance of Fluorescence Molecular Imaging Devices Using Traceable Working Standards With SI Units of Radiance

    by Banghe Zhu, John C. Rasmussen, Maritoni Litorja, Eva M. Sevick-Muraca

    To date, no emerging preclinical or clinical near-infrared fluorescence (NIRF) imaging devices for noninvasive and/or surgical guidance have their performances validated on working standards with SI units of radiance that enable comparison or quantitative quality assurance. In this work, we developed and deployed a methodology to calibrate a stable, solid phantom for emission radiance with International System of Units (SI) units of mW ·sr -1 ·cm -2 for use in characterizing the measurement sensitivity of ICCD and IsCMOS detection, signal-to-noise ratio, and contrast. In addition, at calibrated radiances, we assess transverse and lateral resolution of ICCD and IsCMOS camera systems. The methodology allowed demonstration of superior SNR of the ICCD over the IsCMOS technology and superior resolution of the IsCMOS over the ICCD approach. Contrast depended upon the camera settings (binning and integration time) and gain of intensifier. Finally, because the architecture of CMOS and CCD camera systems results in vastly different performance, we comment on the utility of these technologies for small animal imaging as well as clinical applications for noninvasive and surgical guidance.


  • Abstract 4298: Comparison of dual labeling strategies for NIRF/PET hybrid imaging

    by Sukhen C. Ghosh, Barrett R. Harvey, Holly Robinson, Kenneth L. Pinkston, Nathaniel Wilganowski, Banghe Zhu, Eva M. Sevick-Muraca, Ali Azhdarinia

    Objectives: Positron Emission Tomography (PET) plays a pivotal role in the surgical care of cancer patients pre- and post-operatively, however, no functional imaging approaches are currently available for real-time surgical guidance. Recently, antibodies dual-labeled with radioactive and near-infrared fluorescent (NIRF) labels have emerged as potential agents to extend whole-body nuclear imaging capabilities into the operating room, but structural limitations in conventional labeling reagents necessitate a random, two-step labeling process which can reduce bioactivity and batch reproducibility. Here, we evaluate the utility of a site-specific multimodal chelator (MMC) that combines PET/NIRF labeling into a single moiety for enhanced production of immunoconjugates for hybrid imaging.

  • Non-invasive fluorescence imaging under ambient light conditions using a modulated ICCD and laser diode

    by Banghe Zhu, John C. Rasmussen, Eva M. Sevick-Muraca

    One limitation of fluorescence molecular imaging that can limit clinical implementation and hamper small animal imaging is the inability to eliminate ambient light. Herein, we demonstrate the ability to conduct rapid non-invasive, far-red and near-infrared fluorescence imaging in living animals and a phantom under ambient light conditions using a modulated image intensified CCD (ICCD) and a laser diode operated in homodyne detection. By mapping AC amplitude from three planar images at varying phase delays, we show improvement in target-to-background ratios (TBR) and reasonable signal-to-noise ratios (SNR) over continuous wave measurements. The rapid approach can be used to accurately collect fluorescence in situations where ambient light cannot be spectrally conditioned or controlled, such as in the case of fluorescent molecular image-guided surgery.