Akshaya K. Pati
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Akshaya K. Pati has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- N. C. Sahoo
School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Odisha, India
2 shared publications Mohit Choudhary
School of Electronics, Kalinga Institute of Industrial Technology,Bhubaneswar,India
1 shared publicationN. C. Sahoo
School of Electrical Sciences, Indian Institute of Technology, Bhubaneswar, India
1 shared publicationNirod C Sahoo
School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, India
1 shared publicationNirod C. Sahoo
School of Electrical SciencesIndian Institute of Technology Bhubaneswar Bhubaneswar Odisha India
1 shared publication- Pravat Biswal
School of Electronics Engineering, KIIT University, Bhubaneswar, Odisha, India
1 shared publication
Latest Publications
- 24 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimizing Solar Energy Harvesting: Dual-Axis Solar Tracking and Simulation Analysis
This study explores the optimization of solar energy capture through the implementation of a dual-axis solar tracking system, coupled with advanced simulation using the PVsyst software. The objective is to enhance energy efficiency by precisely aligning photovoltaic panels with the sun's path. Our research investigates the performance of this system under varying environmental conditions and geographical locations. The PVsyst simulation offers valuable insights into energy generation potential, efficiency gains, and financial viability. Preliminary results indicate a substantial increase in energy yield compared to fixed panels, especially in regions with dynamic solar angles. The findings from this study underscore the significance of simulation-based approaches in assessing and maximizing the effectiveness of dual-axis.
- 24 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimizing Solar Energy Harvesting: Dual-Axis Solar Tracking and Simulation Analysis
This study explores the optimization of solar energy capture through the implementation of a dual-axis solar tracking system, coupled with advanced simulation using the PVsyst software. The objective is to enhance energy efficiency by precisely aligning photovoltaic panels with the sun's path. Our research investigates the performance of this system under varying environmental conditions and geographical locations. The PVsyst simulation offers valuable insights into energy generation potential, efficiency gains, and financial viability. Preliminary results indicate a substantial increase in energy yield compared to fixed panels, especially in regions with dynamic solar angles. The findings from this study underscore the significance of simulation-based approaches in assessing and maximizing the effectiveness of dual-axis.
- 5 March 2020
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 42 (12) , 2139-2154
A super-twisting sliding mode observer for boost inverter-based hybrid photovoltaic -battery system control
This paper proposes an observer-based control scheme for a three-phase differential boost inverter in a hybrid PV-battery system. In a conventional control scheme for three-phase differential boost inverter (DBI)-based PV system, the measurements of input inductor current and voltage across output capacitors are required for obtaining the desired voltage at the load end. In a typical three-phase differential boost inverter operation, four voltage sensors and seven current sensors are required to achieve the desired AC voltage. In this paper, an observer-based strategy for elimination of these sensors without compromising power quality is reported. For estimation of boost inverter inductor current and output capacitor voltage, only DC-link capacitor voltage and the load currents are measured. A super-twisting sliding mode observer is used for estimation of the states of the boost inverter. A comparative study between the first-order sliding mode observer and super-twisting sliding mode observer is also presented. The simulation and experimental results show that the proposed observer-based control scheme works satisfactorily under various operating conditions such as sudden change of load, changes in solar insolation, and also under unbalanced load conditions.
- 5 March 2020
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 42 (12) , 2139-2154
A super-twisting sliding mode observer for boost inverter-based hybrid photovoltaic -battery system control
This paper proposes an observer-based control scheme for a three-phase differential boost inverter in a hybrid PV-battery system. In a conventional control scheme for three-phase differential boost inverter (DBI)-based PV system, the measurements of input inductor current and voltage across output capacitors are required for obtaining the desired voltage at the load end. In a typical three-phase differential boost inverter operation, four voltage sensors and seven current sensors are required to achieve the desired AC voltage. In this paper, an observer-based strategy for elimination of these sensors without compromising power quality is reported. For estimation of boost inverter inductor current and output capacitor voltage, only DC-link capacitor voltage and the load currents are measured. A super-twisting sliding mode observer is used for estimation of the states of the boost inverter. A comparative study between the first-order sliding mode observer and super-twisting sliding mode observer is also presented. The simulation and experimental results show that the proposed observer-based control scheme works satisfactorily under various operating conditions such as sudden change of load, changes in solar insolation, and also under unbalanced load conditions.
- 3 February 2019
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 29 (5) , e2832
A novel power quality enhancement scheme for three‐phase differential boost inverter–based grid‐connected photovoltaic system with repetitive and feedback linearizing control
In grid‐connected (GC) photovoltaic (PV) system with a three‐phase voltage source inverter (VSI), one major requirement is that the DC‐side voltage should be greater than the inverter AC‐side voltage. In many PV installations, this is difficult to attain without an additional DC‐DC converter. For such scenarios, a three‐phase differential boost inverter, where input DC voltage can be less than AC‐side voltage, is a promising configuration. For GC PV systems integrated with such power electronic switching converters, the power quality control also plays a significant importance. In this paper, a novel power quality control technique for such a GC PV system based on three‐phase differential boost inverter has been proposed and evaluated. The proposed control system consists of three subsystem level control loops: (1) a novel control unit for reference voltage generation required for power quality improvement, (2) a double‐loop control strategy with plug‐in–type repetitive Proportional‐Integral (PI) control for outer loop and feedback linearizing control for inner loop meant for tracking of boost inverter output reference voltages, and (3) another bidirectional DC‐DC converter controller for battery operation. The performance of the proposed control algorithms has been tested under various scenarios, ie, power management, transition between GC to stand‐alone (SA) modes and vice versa, and grid current compensation under unbalanced load, nonlinear load, and unbalanced and distorted grid voltage conditions. Extensive simulation and experimental results are reported for validating the proposed control technique.
- 3 February 2019
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 29 (5) , e2832
A novel power quality enhancement scheme for three‐phase differential boost inverter–based grid‐connected photovoltaic system with repetitive and feedback linearizing control
In grid‐connected (GC) photovoltaic (PV) system with a three‐phase voltage source inverter (VSI), one major requirement is that the DC‐side voltage should be greater than the inverter AC‐side voltage. In many PV installations, this is difficult to attain without an additional DC‐DC converter. For such scenarios, a three‐phase differential boost inverter, where input DC voltage can be less than AC‐side voltage, is a promising configuration. For GC PV systems integrated with such power electronic switching converters, the power quality control also plays a significant importance. In this paper, a novel power quality control technique for such a GC PV system based on three‐phase differential boost inverter has been proposed and evaluated. The proposed control system consists of three subsystem level control loops: (1) a novel control unit for reference voltage generation required for power quality improvement, (2) a double‐loop control strategy with plug‐in–type repetitive Proportional‐Integral (PI) control for outer loop and feedback linearizing control for inner loop meant for tracking of boost inverter output reference voltages, and (3) another bidirectional DC‐DC converter controller for battery operation. The performance of the proposed control algorithms has been tested under various scenarios, ie, power management, transition between GC to stand‐alone (SA) modes and vice versa, and grid current compensation under unbalanced load, nonlinear load, and unbalanced and distorted grid voltage conditions. Extensive simulation and experimental results are reported for validating the proposed control technique.
- 1 July 2017
- Published by Elsevier in ISA Transactions
- Vol. 69, 296-306
Adaptive super-twisting sliding mode control for a three-phase single-stage grid-connected differential boost inverter based photovoltaic system
- 1 July 2017
- Published by Elsevier in ISA Transactions
- Vol. 69, 296-306
Adaptive super-twisting sliding mode control for a three-phase single-stage grid-connected differential boost inverter based photovoltaic system
- 4 January 2016
- Published by Springer Nature in Energy Systems
- Vol. 7 (1) , 145-172
A new approach in maximum power point tracking for a photovoltaic array with power management system using Fibonacci search algorithm under partial shading conditions
- 4 January 2016
- Published by Springer Nature in Energy Systems
- Vol. 7 (1) , 145-172
A new approach in maximum power point tracking for a photovoltaic array with power management system using Fibonacci search algorithm under partial shading conditions
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 599-604
Power quality improvement by feedback linearization control of grid connected three phase boost inverter
This paper proposes application of three-phase boost inverter for harmonic and reactive power compensation at the point of common coupling (PCC). A three-phase boost inverter is a combination of three symmetrical parameter boost converters connected in cascade. A DC link voltage control approach with a phase locked loop system is used to generate the synchronized reference voltage for the boost converter. Here, a double loop control approach with inner loop as feedback linearization control is used to track the reference voltage across the output capacitor of each boost converter. Using the synchronized waveform, a reference unit vector is generated. By converting the reference voltage to unit vector, amount of harmonic contents in the load current is measured. The boost inverter injects desired amount of current to the PCC to make the main grid supply current as pure sinusoidal. The performance of the proposed system is verified using MATLAB/SIMULINK.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 599-604
Power quality improvement by feedback linearization control of grid connected three phase boost inverter
This paper proposes application of three-phase boost inverter for harmonic and reactive power compensation at the point of common coupling (PCC). A three-phase boost inverter is a combination of three symmetrical parameter boost converters connected in cascade. A DC link voltage control approach with a phase locked loop system is used to generate the synchronized reference voltage for the boost converter. Here, a double loop control approach with inner loop as feedback linearization control is used to track the reference voltage across the output capacitor of each boost converter. Using the synchronized waveform, a reference unit vector is generated. By converting the reference voltage to unit vector, amount of harmonic contents in the load current is measured. The boost inverter injects desired amount of current to the PCC to make the main grid supply current as pure sinusoidal. The performance of the proposed system is verified using MATLAB/SIMULINK.