Qiang Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Qiang Chen has a total of 131 co-authors. Here are the top co-authors by number of shared publications:
Junshuai Li
LONGi Institute of Future Technology and School of Materials & Energy, Lanzhou University Lanzhou China
23 shared publicationsQing Huo Liu
Department of Electrical and Computer Engineering, Duke University, Durham, NC 27708, United States of America
12 shared publicationsQing Xiong
Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
11 shared publicationsXin Wang
Xiamen University
11 shared publicationsRikizo Hatakeyama
Department of Electronic Engineering, Tohoku University 1 , Sendai 980-8579, Japan
10 shared publicationsBangbang He
Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance Institute of Electromagnetics and Acoustics, Xiamen University Xiamen China
9 shared publications
Latest Publications
- 19 May 2026
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 28 (8) , 085502
Plasma catalyzed hydrogen peroxide synthesis in an H-type electrochemical cell
Hydrogen peroxide (H2O2) is a versatile green oxidant widely used in environmental remediation, disinfection, and chemical processing. Plasma electrochemical synthesis offers a catalyst-free and decentralized route for on-site H2O2 production directly from water under ambient conditions. In this study, H2O2 generation is investigated in a double-layer H-type plasma electrochemical reactor, with systematic evaluation of discharge current, solution flow rate, temperature, and working gas composition. The H2O2 concentration increases linearly with increasing discharge current, while competing plasma reactions caused limited electron utilization efficiency. Lower solution flow rates favored higher product accumulation, while elevated temperatures enhanced decomposition under circulation conditions. Gas composition plays a decisive role: Ar plasma produced higher H2O2 yields than O2 or N2, whereas air significantly suppressed H2O2 formation due to nitrite-mediated consumption pathways. An optimized Ar/O2 mixture (54/6 sccm) enables enhanced performance, achieving a maximum H2O2 concentration of 120 mM after 4 h plasma operation. Although this represents significant progress, a substantial gap remains toward practically usable H2O2 concentrations, highlighting the need for further reactor and energy-efficiency optimization.
- 19 May 2026
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 28 (8) , 085502
Plasma catalyzed hydrogen peroxide synthesis in an H-type electrochemical cell
Hydrogen peroxide (H2O2) is a versatile green oxidant widely used in environmental remediation, disinfection, and chemical processing. Plasma electrochemical synthesis offers a catalyst-free and decentralized route for on-site H2O2 production directly from water under ambient conditions. In this study, H2O2 generation is investigated in a double-layer H-type plasma electrochemical reactor, with systematic evaluation of discharge current, solution flow rate, temperature, and working gas composition. The H2O2 concentration increases linearly with increasing discharge current, while competing plasma reactions caused limited electron utilization efficiency. Lower solution flow rates favored higher product accumulation, while elevated temperatures enhanced decomposition under circulation conditions. Gas composition plays a decisive role: Ar plasma produced higher H2O2 yields than O2 or N2, whereas air significantly suppressed H2O2 formation due to nitrite-mediated consumption pathways. An optimized Ar/O2 mixture (54/6 sccm) enables enhanced performance, achieving a maximum H2O2 concentration of 120 mM after 4 h plasma operation. Although this represents significant progress, a substantial gap remains toward practically usable H2O2 concentrations, highlighting the need for further reactor and energy-efficiency optimization.
- 4 May 2024
- Published by Springer Nature in The European Physical Journal D
- Vol. 78 (5) , 1-10
A reactor for generating DC plasma inside a liquid
- 4 May 2024
- Published by Springer Nature in The European Physical Journal D
- Vol. 78 (5) , 1-10
A reactor for generating DC plasma inside a liquid
- 26 March 2024
- Published by Wiley in Plasma Processes and Polymers
Revisiting the application of molecular probe diagnostics on quantifying aqueous OH radicals in plasma–liquid systems
We revisit one of the most used techniques for quantifying the aqueous OH radicals (OH aq ) in plasma–liquid systems, the molecular probe method which obtains the [OH aq ] by measuring a stable material formed through a rapid reaction between the molecular probe and the OH aq . In this study, we used disodium terephthalate (NaTA) as the molecular probe; the experimental results with a theoretical analysis suggest that to obtain the correct OH aq concentration, the concentration of the molecular probe should be greater than a certain value, which depends on the types of the plasma–liquid systems. However, this is not the case in most of the existing reports in which the NaTA is often much less than the requisite value.
- 26 March 2024
- Published by Wiley in Plasma Processes and Polymers
Revisiting the application of molecular probe diagnostics on quantifying aqueous OH radicals in plasma–liquid systems
We revisit one of the most used techniques for quantifying the aqueous OH radicals (OH aq ) in plasma–liquid systems, the molecular probe method which obtains the [OH aq ] by measuring a stable material formed through a rapid reaction between the molecular probe and the OH aq . In this study, we used disodium terephthalate (NaTA) as the molecular probe; the experimental results with a theoretical analysis suggest that to obtain the correct OH aq concentration, the concentration of the molecular probe should be greater than a certain value, which depends on the types of the plasma–liquid systems. However, this is not the case in most of the existing reports in which the NaTA is often much less than the requisite value.
- 29 June 2022
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 24 (8) , 085502
A simple derivative spectrophotometric method for simultaneously detecting nitrate and nitrite in plasma treated water
A spectrophotometric technique is developed to simultaneously quantify nitrate and nitrite in plasma treated water. The measurement is based on examining the inflection points (wavelengths) in the derivative absorbance of the nitrate or nitrite solution. At the inflection points of the pure nitrate solution, the derivative absorbance is zero and independent of the nitrate’s concentration, and thus the nitrite’s concentration in a mixed nitrate and nitrite solution can be obtained by using the Beer’s law at these points. The nitrate’s concentration can also be achieved from the inflection points of nitrite in the same manner. The relation between the tested substance’s (nitrate or nitrite) concentration and the second- or the third-order absorbances is obtained at these inflection points. Test measurements for mixed aqueous solutions of nitrate and nitrite with or without hydrogen peroxide confirm the reliability of this technique. We applied this technique to quantify the nitrate and nitrite generated in air plasma treated aqueous solutions. The results indicate that both nitrate and nitrite concentrations increase with the plasma treatment time, and the nitrite species is found to be generated prior to the nitrate species in the air plasma treated aqueous solution. Moreover, the production rate of total nitrogen species is independent of the solutions’ pH value. These results are relevant to diverse applications of plasma activated solutions in materials processing, biotechnology, medicine and other fields.
- 29 June 2022
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 24 (8) , 085502
A simple derivative spectrophotometric method for simultaneously detecting nitrate and nitrite in plasma treated water
A spectrophotometric technique is developed to simultaneously quantify nitrate and nitrite in plasma treated water. The measurement is based on examining the inflection points (wavelengths) in the derivative absorbance of the nitrate or nitrite solution. At the inflection points of the pure nitrate solution, the derivative absorbance is zero and independent of the nitrate’s concentration, and thus the nitrite’s concentration in a mixed nitrate and nitrite solution can be obtained by using the Beer’s law at these points. The nitrate’s concentration can also be achieved from the inflection points of nitrite in the same manner. The relation between the tested substance’s (nitrate or nitrite) concentration and the second- or the third-order absorbances is obtained at these inflection points. Test measurements for mixed aqueous solutions of nitrate and nitrite with or without hydrogen peroxide confirm the reliability of this technique. We applied this technique to quantify the nitrate and nitrite generated in air plasma treated aqueous solutions. The results indicate that both nitrate and nitrite concentrations increase with the plasma treatment time, and the nitrite species is found to be generated prior to the nitrate species in the air plasma treated aqueous solution. Moreover, the production rate of total nitrogen species is independent of the solutions’ pH value. These results are relevant to diverse applications of plasma activated solutions in materials processing, biotechnology, medicine and other fields.
- 8 March 2022
- Published by Springer Nature in Journal of Materials Science
- Vol. 57 (11) , 6308-6319
Tubular nanocarbon/SnS nanosheets/amorphous carbon composites with enhanced sodium ion storage performance
- 8 March 2022
- Published by Springer Nature in Journal of Materials Science
- Vol. 57 (11) , 6308-6319
Tubular nanocarbon/SnS nanosheets/amorphous carbon composites with enhanced sodium ion storage performance
- Open Access
- 30 January 2022
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 7 (3) , 405-419
Recent advances towards aqueous hydrogen peroxide formation in a direct current plasma–liquid system
The aqueous phase hydrogen peroxide (H 2 O 2aq ) produced from the plasma–liquid interactions can directly or synergistically (with other substances) affect the liquid chemistry, and therefore it is important to unfold the H 2 O 2aq formation mechanism. However, up to now, a consensus on the H 2 O 2aq formation mechanism is not reached. This review aims to survey the recent advances on the understanding of the H 2 O 2aq formation mechanism in the system of a direct current discharge plasma operated over a liquid electrode. Theoretical and experimental analyses indicate that the recombination of dissolved OH radicals (OH aq ) is the dominant process for the H 2 O 2aq formation, while the purported plasma‐induced photolysis of water and the dissolution of gaseous H 2 O 2 are ruled out.
- 30 January 2022
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 7 (3) , 405-419
Open AccessRecent advances towards aqueous hydrogen peroxide formation in a direct current plasma–liquid system
The aqueous phase hydrogen peroxide (H 2 O 2aq ) produced from the plasma–liquid interactions can directly or synergistically (with other substances) affect the liquid chemistry, and therefore it is important to unfold the H 2 O 2aq formation mechanism. However, up to now, a consensus on the H 2 O 2aq formation mechanism is not reached. This review aims to survey the recent advances on the understanding of the H 2 O 2aq formation mechanism in the system of a direct current discharge plasma operated over a liquid electrode. Theoretical and experimental analyses indicate that the recombination of dissolved OH radicals (OH aq ) is the dominant process for the H 2 O 2aq formation, while the purported plasma‐induced photolysis of water and the dissolution of gaseous H 2 O 2 are ruled out.
- 1 December 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (12) , 123508
The Ag+ Reduction Process in a Plasma Electrochemical System Tuned by the pH Value
The interactions between discharge plasmas and an aqueous solutions can enable the production of reactive species and charge transfer at the plasma-liquid interface, forming the plasma electrochemical system (PES). The PES are promising for diverse applications, such as nanomaterials synthesis, due to the activation of the solution chemistry by the plasma. In this paper, we investigate the influence of the solution’s pH value on the formation of silver nanoparticles (AgNPs) in a direct current (DC) PES. Dual argon DC plasmas are generated in an H-type electrochemical cell containing an aqueous solution of silver nitrate with pH values in the range of 1.99–10.71. By this design, the solution acts as a cathode at one end of the H-type cell, and as an anode at the other end. The results show that the AgNPs are formed at the anode except for the solution with the pH value of 1.99. However, at the cathode, the AgNPs only appear in the solution with the pH value of 10.71. We find that the solvated electrons and hydrogen peroxide produced by the plasma-liquid interactions are responsible for the Ag+ reduction at the solution anode and the solution cathode, respectively.
- 1 December 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (12) , 123508
The Ag+ Reduction Process in a Plasma Electrochemical System Tuned by the pH Value
The interactions between discharge plasmas and an aqueous solutions can enable the production of reactive species and charge transfer at the plasma-liquid interface, forming the plasma electrochemical system (PES). The PES are promising for diverse applications, such as nanomaterials synthesis, due to the activation of the solution chemistry by the plasma. In this paper, we investigate the influence of the solution’s pH value on the formation of silver nanoparticles (AgNPs) in a direct current (DC) PES. Dual argon DC plasmas are generated in an H-type electrochemical cell containing an aqueous solution of silver nitrate with pH values in the range of 1.99–10.71. By this design, the solution acts as a cathode at one end of the H-type cell, and as an anode at the other end. The results show that the AgNPs are formed at the anode except for the solution with the pH value of 1.99. However, at the cathode, the AgNPs only appear in the solution with the pH value of 10.71. We find that the solvated electrons and hydrogen peroxide produced by the plasma-liquid interactions are responsible for the Ag+ reduction at the solution anode and the solution cathode, respectively.
- 29 April 2021
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 23 (5) , 055504
Colorimetric quantification of aqueous hydrogen peroxide in the DC plasma-liquid system
The quantification of hydrogen peroxide (H2O2) generated in the plasma-liquid interactions is of great importance, since the H2O2 species is vital for the applications of the plasma-liquid system. Herein, we report on in situ quantification of the aqueous H2O2 (H2O2aq) using a colorimetric method for the DC plasma-liquid systems with liquid as either a cathode or an anode. The results show that the H2O2aq yield is 8–12 times larger when the liquid acts as a cathode than when the liquid acts as an anode. The conversion rate of the gaseous OH radicals to H2O2aq is 4–6 times greater in the former case. However, the concentrations of dissolved OH radicals for both liquid as cathode and anode are of the same order of tens of nM.
- 29 April 2021
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 23 (5) , 055504
Colorimetric quantification of aqueous hydrogen peroxide in the DC plasma-liquid system
The quantification of hydrogen peroxide (H2O2) generated in the plasma-liquid interactions is of great importance, since the H2O2 species is vital for the applications of the plasma-liquid system. Herein, we report on in situ quantification of the aqueous H2O2 (H2O2aq) using a colorimetric method for the DC plasma-liquid systems with liquid as either a cathode or an anode. The results show that the H2O2aq yield is 8–12 times larger when the liquid acts as a cathode than when the liquid acts as an anode. The conversion rate of the gaseous OH radicals to H2O2aq is 4–6 times greater in the former case. However, the concentrations of dissolved OH radicals for both liquid as cathode and anode are of the same order of tens of nM.
- 11 March 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (22) , 229501
Corrigendum: Ethanol-controlled peroxidation in liquid-anode discharges (2019 J. Phys. D: Appl. Phys. 52 425205)
- 11 March 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (22) , 229501
Corrigendum: Ethanol-controlled peroxidation in liquid-anode discharges (2019 J. Phys. D: Appl. Phys. 52 425205)
- 23 July 2020
- Published by Springer Nature in The European Physical Journal D
- Vol. 74 (7) , 1-2
Erratum to: The formation mechanism of aqueous hydrogen peroxide in a plasma-liquid system with liquid as the anode
- 23 July 2020
- Published by Springer Nature in The European Physical Journal D
- Vol. 74 (7) , 1-2
Erratum to: The formation mechanism of aqueous hydrogen peroxide in a plasma-liquid system with liquid as the anode