Yawei Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yawei Wei has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Ganesh Kumar Venayagamoorthy
Real‐Time Power and Intelligent Systems Laboratory, The Holcombe Department of Electrical and Computer Engineering Clemson University Clemson SC 29634 USA
8 shared publicationsIroshani Jayawardene
Real‐Time Power and Intelligent Systems Laboratory, The Holcombe Department of Electrical and Computer Engineering Clemson University Clemson SC 29634 USA
3 shared publicationsParanietharan Arunagirinathan
3 shared publications- Ali Arzani
Center for Energy Systems Research, Tennessee Technological University, Cookeville, TN, USA
2 shared publications Ashfaqur Rahman
Real Time Power and Intelligent Systems Laboratory, Clemson University, Clemson, SC, USA
1 shared publicationBruce A. Mork
Department of Electrical and Computer Engineering, Michigan Technological University, Houghton, USA
1 shared publication
Latest Publications
- Open Access
- 13 September 2019
- Published by Institution of Engineering and Technology (IET) in IET Smart Grid
- Vol. 2 (4) , 581-593
Optimal automatic generation controllers in a multi‐area interconnected power system with utility‐scale PV plants
The centralised utility‐scale photovoltaic (PV) plants installation has greatly enlarged their percentage in the bulk power systems, along with the nature uncertainty for the balance of system power and loads. Consequently, the successful integration of solar PV power in large‐scale power systems requires a reliable and efficient multi‐area automatic generation control (AGC) system within the control centre. Specifically, area‐AGCs that perform tie‐line bias control, in which the area frequency regulates the tie‐line power flow, must balance the operational control area supply power‐and‐demand loads within a pre‐tuned parameter set. Traditional AGC control systems have area linear controllers that must be periodically tuned to manage the high fluctuation of PV power. A practical two‐step tuning method to determine the optimal parameters of existing multi‐area AGCs is presented. The proposed method is demonstrated on a five‐area multi‐machine power system with two large PV plants. The power system was equipped with the synchrophasor‐based monitoring system, with a real‐time simulation platform serving as the application host. Results indicated that the two‐step tuning method provides optimal parameters for all the system AGCs over a wide range of PV penetration levels. Typical results demonstrated the effectiveness of the tuned multi‐area AGCs under dynamic conditions and disturbances.
- 13 September 2019
- Published by Institution of Engineering and Technology (IET) in IET Smart Grid
- Vol. 2 (4) , 581-593
Open AccessOptimal automatic generation controllers in a multi‐area interconnected power system with utility‐scale PV plants
The centralised utility‐scale photovoltaic (PV) plants installation has greatly enlarged their percentage in the bulk power systems, along with the nature uncertainty for the balance of system power and loads. Consequently, the successful integration of solar PV power in large‐scale power systems requires a reliable and efficient multi‐area automatic generation control (AGC) system within the control centre. Specifically, area‐AGCs that perform tie‐line bias control, in which the area frequency regulates the tie‐line power flow, must balance the operational control area supply power‐and‐demand loads within a pre‐tuned parameter set. Traditional AGC control systems have area linear controllers that must be periodically tuned to manage the high fluctuation of PV power. A practical two‐step tuning method to determine the optimal parameters of existing multi‐area AGCs is presented. The proposed method is demonstrated on a five‐area multi‐machine power system with two large PV plants. The power system was equipped with the synchrophasor‐based monitoring system, with a real‐time simulation platform serving as the application host. Results indicated that the two‐step tuning method provides optimal parameters for all the system AGCs over a wide range of PV penetration levels. Typical results demonstrated the effectiveness of the tuned multi‐area AGCs under dynamic conditions and disturbances.
- 1 July 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 172, 38-49
Situational awareness of coherency behavior of synchronous generators in a power system with utility-scale photovoltaics
- 1 July 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 172, 38-49
Situational awareness of coherency behavior of synchronous generators in a power system with utility-scale photovoltaics
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Wide-Area Situational Awareness based Power System Stabilizer Tuning with Utility Scale PV Integration
Historically, poorly damped electromechanical oscillations exhibited by synchronous generators have caused power system blackouts. With variable generation sources such as PV power integrated in power systems, the high variability and lack of sufficiently accurate forecasts, triggers electromechanical oscillations. Optimally tuned power system stabilizers (PSSs) are expected to provide effective damping to these electromechanical oscillations. The effects of the variations of the PV power and system disturbances on the speed deviations of the generators are captured and used in the formulation of the cost function to be optimized. The IEEE 68 bus 16 generator benchmark New England-New York power system integrated with utility scale PV generation sources is studied.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Wide-Area Situational Awareness based Power System Stabilizer Tuning with Utility Scale PV Integration
Historically, poorly damped electromechanical oscillations exhibited by synchronous generators have caused power system blackouts. With variable generation sources such as PV power integrated in power systems, the high variability and lack of sufficiently accurate forecasts, triggers electromechanical oscillations. Optimally tuned power system stabilizers (PSSs) are expected to provide effective damping to these electromechanical oscillations. The effects of the variations of the PV power and system disturbances on the speed deviations of the generators are captured and used in the formulation of the cost function to be optimized. The IEEE 68 bus 16 generator benchmark New England-New York power system integrated with utility scale PV generation sources is studied.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-8
Optimized automatic generation control in a multi-area power system with particle swarm optimization
An unexpected load change in an interconnected multi-area power system can cause variations in area frequencies and tie-line power flows of the system. Integration of renewable energy sources increases the uncertainties in a power system, which causes more frequency and tie-line power variabilities. Automatic generation control (AGC) plays a vital role in multi-area power systems in maintaining area frequencies and tie-line power flows at their nominal values while utilizing available renewable energy. An effective AGC requires optimal selection of its parameters for best tie-line bias control. In this study, a particle swarm optimization (PSO) approach is presented for tuning parameters of AGCs in a multi-area power system with photovoltaic plants. A modified IEEE New-England and NewYork test model with five AGCs is simulated on a real-time digital simulator. Typical results indicate that PSO based AGC parameters provide minimal area control errors with improved system performance.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-8
Optimized automatic generation control in a multi-area power system with particle swarm optimization
An unexpected load change in an interconnected multi-area power system can cause variations in area frequencies and tie-line power flows of the system. Integration of renewable energy sources increases the uncertainties in a power system, which causes more frequency and tie-line power variabilities. Automatic generation control (AGC) plays a vital role in multi-area power systems in maintaining area frequencies and tie-line power flows at their nominal values while utilizing available renewable energy. An effective AGC requires optimal selection of its parameters for best tie-line bias control. In this study, a particle swarm optimization (PSO) approach is presented for tuning parameters of AGCs in a multi-area power system with photovoltaic plants. A modified IEEE New-England and NewYork test model with five AGCs is simulated on a real-time digital simulator. Typical results indicate that PSO based AGC parameters provide minimal area control errors with improved system performance.
- 1 September 2017
- Published by Elsevier in Neural Networks
- Vol. 93, 21-35
Cellular computational generalized neuron network for frequency situational intelligence in a multi-machine power system
- 1 September 2017
- Published by Elsevier in Neural Networks
- Vol. 93, 21-35
Cellular computational generalized neuron network for frequency situational intelligence in a multi-machine power system
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4252-4258
Cellular computational generalized neuron network with cooperative PSO for power systems
To enhance the reliability of the power system, newer technologies are being incorporated day by day. Predictions of different states can significantly increase the reliability of the system. To predict the frequency, a cellular computational generalized neuron network (CCGNN) that is trained with particle swarm optimization (PSO) is proposed recently. However, with the size of the system, the dimension of PSO grows that in turn, increases the complexity of the training. To solve the problem, a special version of PSO named cooperative PSO (CPSO) is applied for training the CCGNN in this paper. Through simulation on a 68-dimensional problem of a two-area four-machine system, it is shown that the CPSO performs significantly better than the canonical one.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4252-4258
Cellular computational generalized neuron network with cooperative PSO for power systems
To enhance the reliability of the power system, newer technologies are being incorporated day by day. Predictions of different states can significantly increase the reliability of the system. To predict the frequency, a cellular computational generalized neuron network (CCGNN) that is trained with particle swarm optimization (PSO) is proposed recently. However, with the size of the system, the dimension of PSO grows that in turn, increases the complexity of the training. To solve the problem, a special version of PSO named cooperative PSO (CPSO) is applied for training the CCGNN in this paper. Through simulation on a 68-dimensional problem of a two-area four-machine system, it is shown that the CPSO performs significantly better than the canonical one.
- 21 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Situational intelligence for online coherency analysis of synchronous generators in power system
This paper presents a situational intelligence (SI) based approach to carry out coherency analysis of synchronous generator in a power system in an online manner. A cellular computational network (CCN) is used as the SI algorithm. CCN is a framework for distributed multi-timescale frequency prediction by utilizing the local and neighboring phasor measurement units (PMUs). The predicted frequency values are utilized for coherency analysis. The advantages of the CCN are scalability and distributedness which caters for on-line predicted coherency analysis for large power systems. The multi-time scale frequency predictions mitigates or minimizes delays in power system measurements and provides an insight to the power system coherent behavior apriori. The simulation studies on the New York-New England IEEE benchmark power system are presented to demonstrate that CCN based SI can be utilized in online coherency analysis. Predicted measurements can enhance resiliency to bad data. Furthermore, it is possible to utilize this approach for adaptive control of wide area power systems.
- 21 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Situational intelligence for online coherency analysis of synchronous generators in power system
This paper presents a situational intelligence (SI) based approach to carry out coherency analysis of synchronous generator in a power system in an online manner. A cellular computational network (CCN) is used as the SI algorithm. CCN is a framework for distributed multi-timescale frequency prediction by utilizing the local and neighboring phasor measurement units (PMUs). The predicted frequency values are utilized for coherency analysis. The advantages of the CCN are scalability and distributedness which caters for on-line predicted coherency analysis for large power systems. The multi-time scale frequency predictions mitigates or minimizes delays in power system measurements and provides an insight to the power system coherent behavior apriori. The simulation studies on the New York-New England IEEE benchmark power system are presented to demonstrate that CCN based SI can be utilized in online coherency analysis. Predicted measurements can enhance resiliency to bad data. Furthermore, it is possible to utilize this approach for adaptive control of wide area power systems.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3085-3092
A lite cellular generalized neuron network for frequency prediction of synchronous generators in a multimachine power system
Power system protection and emergency control systems require continuous monitoring to prevent grid-wide frequency instability or system islanding. Amongst different methods, cellular computation networks (CCNs) are more suitable for providing dynamic frequency predictions. CCN is a scalable and distributed framework using the concept of cells and intercellular connections to represent a power system topology with multiple synchronous machines, transmission lines and loads. However, from a practical viewpoint, fast computing algorithms are needed for effective monitoring and response. In this paper, a lite CCN is proposed based on generalized neurons (GNs), referred to as the cellular generalized neuron network (CGNN). The performance of CGNN is compared with that of a cellular multilayer perceptron network (CMLPN). The frequency predictions by the CGNN and CMLPN have been validated on a two-area four-machine benchmark power system. Data for the CGNN is provided from a real time digital simulation of the power system with phasor measurement units (PMUs). Based on a performance metric, results obtained show that the CGNN outperforms the CMLPN, especially in terms of least number of trainable parameters, low training time and better prediction accuracy.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3085-3092
A lite cellular generalized neuron network for frequency prediction of synchronous generators in a multimachine power system
Power system protection and emergency control systems require continuous monitoring to prevent grid-wide frequency instability or system islanding. Amongst different methods, cellular computation networks (CCNs) are more suitable for providing dynamic frequency predictions. CCN is a scalable and distributed framework using the concept of cells and intercellular connections to represent a power system topology with multiple synchronous machines, transmission lines and loads. However, from a practical viewpoint, fast computing algorithms are needed for effective monitoring and response. In this paper, a lite CCN is proposed based on generalized neurons (GNs), referred to as the cellular generalized neuron network (CGNN). The performance of CGNN is compared with that of a cellular multilayer perceptron network (CMLPN). The frequency predictions by the CGNN and CMLPN have been validated on a two-area four-machine benchmark power system. Data for the CGNN is provided from a real time digital simulation of the power system with phasor measurement units (PMUs). Based on a performance metric, results obtained show that the CGNN outperforms the CMLPN, especially in terms of least number of trainable parameters, low training time and better prediction accuracy.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 673-678
Frequency Prediction of Synchronous Generators in a Multi-Machine Power System with a Photovoltaic Plant Using a Cellular Computational Network
Power systems with synchronous generators and solar photovoltaic (PV) experience frequency and power fluctuations due to high variability of PV power. Automatic generation control is implemented to control power outputs of the generators and stabilize the system frequency. It is desirable with increasing levels of PV penetration to have foresight of frequency fluctuations to empower advanced control systems. A new methodology is presented in this paper for predicting frequency of synchronous generators in a power system with solar PV. A cellular computational network (CCN) is used to perform the frequency prediction over multi-time scale. CCNs are decentralized and distributed computing paradigms. Thus, CCNs are suitable for fast prediction of frequency of synchronous generators distributed spatially across a power system. The inputs to cells of the CCN are derived from phasor measurement unit (PMU) measurements of frequency and voltage phasor at the respective generator buses. Past, current and predicted measurements enable multi-timescale predictions of synchronous generator frequencies in a power system. Typical multi-time scale frequency predictions using the CCN are illustrated on a two-area four machine power system with solar PV integrated.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 673-678
Frequency Prediction of Synchronous Generators in a Multi-Machine Power System with a Photovoltaic Plant Using a Cellular Computational Network
Power systems with synchronous generators and solar photovoltaic (PV) experience frequency and power fluctuations due to high variability of PV power. Automatic generation control is implemented to control power outputs of the generators and stabilize the system frequency. It is desirable with increasing levels of PV penetration to have foresight of frequency fluctuations to empower advanced control systems. A new methodology is presented in this paper for predicting frequency of synchronous generators in a power system with solar PV. A cellular computational network (CCN) is used to perform the frequency prediction over multi-time scale. CCNs are decentralized and distributed computing paradigms. Thus, CCNs are suitable for fast prediction of frequency of synchronous generators distributed spatially across a power system. The inputs to cells of the CCN are derived from phasor measurement unit (PMU) measurements of frequency and voltage phasor at the respective generator buses. Past, current and predicted measurements enable multi-timescale predictions of synchronous generator frequencies in a power system. Typical multi-time scale frequency predictions using the CCN are illustrated on a two-area four machine power system with solar PV integrated.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Out-of-step detection using Zubov's approximation stability boundaries
This paper presents a new out-of-step detection method for multi-machine power systems based on approximate stability boundaries. The boundaries are constructed based on Zubov's method of stability analysis. The proposed out-of-step detection method first constructs a series of boundaries in power angle - frequency (δ-ω) plane, and tracks the trajectory of each generator in the δ-ω plane after the disturbance to differentiate out-of-step from stable power swings. The electrical parameters needed to construct approximate stability boundaries are obtained directly from Phasor Measurement Units (PMUs) located at the generator's terminal. The effectiveness of the proposed method is tested in a Single Machine Infinite Bus (SMIB) and the IEEE 3-machine 9-bus system. Simulation results show that the proposed algorithm is capable of detecting out-of-step conditions in multi-machine power systems without using network reduction techniques.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Out-of-step detection using Zubov's approximation stability boundaries
This paper presents a new out-of-step detection method for multi-machine power systems based on approximate stability boundaries. The boundaries are constructed based on Zubov's method of stability analysis. The proposed out-of-step detection method first constructs a series of boundaries in power angle - frequency (δ-ω) plane, and tracks the trajectory of each generator in the δ-ω plane after the disturbance to differentiate out-of-step from stable power swings. The electrical parameters needed to construct approximate stability boundaries are obtained directly from Phasor Measurement Units (PMUs) located at the generator's terminal. The effectiveness of the proposed method is tested in a Single Machine Infinite Bus (SMIB) and the IEEE 3-machine 9-bus system. Simulation results show that the proposed algorithm is capable of detecting out-of-step conditions in multi-machine power systems without using network reduction techniques.