VAValentina Arima

Valentina Arima

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Valentina Arima has a total of 255 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The role of dynamic viscosity in evaluating transformer oil aging

    by M. Bianco, A. Zizzari, P. Metrangolo, A.L. Passaseo, G. Pecoraro, V. Tumiatti, A. Passaseo, I. Viola, V. Arima

  • Open Access

    A Droplet-Based Microfluidic Platform for Rapid Optical Detection of Bacteria: Proof-of-Concept for Radiopharmaceutical Sterility Testing

    by Adriano Colombelli, Daniela Lospinoso, Vita Guarino, Alessandra Zizzari, Monica Bianco, Valentina Arima, Roberto Rella, Maria Grazia Manera

    Rapid sterility testing of radiopharmaceuticals is essential due to their short half-lives and strict safety requirements. Conventional culture-based methods require several days and are not compatible with clinical workflows. In this work, we present a proof-of-concept droplet-based microfluidic platform for rapid optical detection of bacterial contamination through optical extinction analysis of microdroplets. Monodisperse water-in-oil microdroplets were generated and optically interrogated using a fiber-based detection system. Calibration was first performed using 500 nm polystyrene nanoparticles to establish the relationship between particle concentration and optical extinction. Subsequently, Staphylococcus aureus suspensions were analyzed under aerobic and anaerobic conditions at concentrations ranging from 0 to 230 CFU/mL. The system demonstrated reliable detection of bacterial contamination with estimated limits of detection of ~15 CFU/mL (aerobic) and ~7.5 CFU/mL (anaerobic). The platform enables real-time, high-throughput analysis with minimal sample handling and reduced analysis time compared to conventional sterility tests. This study validates the feasibility of microdroplet-based optical detection as a rapid quality control strategy specifically suited for radiopharmaceutical production, where the short half-lives of common radiotracers impose strict time constraints incompatible with conventional 14-day culture-based sterility tests. The results provide a proof-of-concept foundation for future integration into automated sterility testing workflows, with further validation on real radiopharmaceutical matrices planned as the next step.

  • Open Access

    Quantifying capillary dynamics in paper-based microchannels using BS and openCV motion Algorithms

    by Gabriele Surano, Alessandra Zizzari, Monica Bianco, Stefano Pascali, Elisabetta Perrone, Ilenia Viola, Gian Paolo Marra, Valentina Arima


  • Open Access

    Cost-Effective and High-Throughput LPS Detection via Microdroplet Technology in Biopharmaceuticals

    by Adriano Colombelli, Daniela Lospinoso, Valentina Arima, Vita Guarino, Alessandra Zizzari, Monica Bianco, Elisabetta Perrone, Luigi Carbone, Roberto Rella, Maria Grazia Manera

    Lipopolysaccharides (LPS) from Gram-negative bacteria represent a significant challenge across various industries due to their prevalence and pathogenicity and the limitations of existing detection methods. Traditional approaches, such as the rabbit pyrogen test (RPT) and the Limulus Amebocyte Lysate (LAL) assay, have served as gold standards for endotoxin detection. However, these methods are constrained by high costs, lengthy processing times, environmental concerns, and the need for significant reagent volumes, which limit their scalability and application in resource-limited settings. In this study, we introduce an innovative microfluidic platform that integrates the LAL assay within microdroplets, addressing the critical limitations of traditional techniques. By leveraging the precise fluid control and reaction isolation offered by microdroplet technology, the system reduces reagent consumption, enhances sensitivity, and enables high-throughput analysis. Calibration tests were performed to validate the platform’s ability to detect LPS, using colorimetric measurements. Results demonstrated comparable or improved performance relative to traditional systems, achieving lower detection limits and greater accuracy. This work demonstrates a proof-of-concept miniaturisation of the pharmacopoeial LAL assay. The method yielded low intra-assay variability (σ ≈ 0.002 OD; CV ≈ 0.9% over n = 50 droplets per point) and a LOD estimated from calibration statistics after path-length normalisation. Broader adoption will require additional comparative validation and standardisation. This scalable, cost-effective, and environmentally sustainable approach offers a practical solution for endotoxin detection in clinical diagnostics, biopharmaceutical production, and environmental monitoring. The proposed technology paves the way for advanced LPS detection methods that meet stringent safety standards while improving efficiency, affordability, and adaptability for diverse applications.


  • Open Access

    PDMS Membranes Drilled by Proton Microbeam Writing: A Customizable Platform for the Investigation of Endothelial Cell–Substrate Interactions in Transwell-like Devices

    by Vita Guarino, Giovanna Vasco, Valentina Arima, Rosella Cataldo, Alessandra Zizzari, Elisabetta Perrone, Giuseppe Gigli, Maura Cesaria

    Cell migration assays provide valuable insights into pathological conditions, such as tumor metastasis and immune cell infiltration, and the regenerative capacity of tissues. In vitro tools commonly used for cell migration studies exploit commercial transwell systems, whose functionalities can be improved through engineering of the pore pattern. In this context, we propose the fabrication of a transwell-like device pursued by combining the proton beam writing (PBW) technique with wet etching onto thin layers of polydimethylsiloxane (PDMS). The resulting transwell-like device incorporates a PDMS membrane with finely controllable pore patterning that was used to study the arrangement and migration behavior of HCMEC/D3 cells, a well-established human brain microvascular endothelial cell model widely used to study vascular maturation in the brain. A comparison between commercial polycarbonate membranes and the PBW-holed membranes highlights the impact of the ordering of the pattern and porosity on cellular growth, self-organization, and transmigration by combining fluorescent microscopy and advanced digital processing. Endothelial cells were found to exhibit distinctive clustering, alignment, and migratory behavior close to the pores of the designed PBW-holed membrane. This is indicative of activation patterns associated with cytoskeletal remodeling, a critical element in the angiogenic process. This study stands up as a novel approach toward the development of more biomimetic barrier models (such as organ-on-chips).


  • Open Access

    Pericyte‐Assisted Vascular Lumen Organization in a Novel Dynamic Human Blood‐Brain Barrier‐on‐Chip Model

    by Vita Guarino, Elisabetta Perrone, Elisa De Luca, Alberto Rainer, Maura Cesaria, Alessandra Zizzari, Monica Bianco, Giuseppe Gigli, Lorenzo Moroni, Valentina Arima

    Organ‐on‐Chip (OoC) technology provides a powerful platform for neurovascular research, enabling the precise replication of the blood‐brain barrier (BBB) microenvironment, including its 3D architecture and the influence of dynamic blood flow. This study introduces a novel microfluidic device designed to investigate the morphological and structural adaptations of human brain endothelial cells (ECs) within narrow, square‐shaped microchannels that closely mimic the microvessels of the brain's microcirculation. The endothelial microchannels are layered above a microchamber filled with Matrigel and abluminal vascular cells, enhancing cell‐cell interactions across the BBB interface. The system integrates co‐culture with pericytes and astrocytes while subjecting brain ECs to physiologically relevant pulsatile flow. The findings reveal that the morphology and cytoskeletal organization of brain ECs are distinctly influenced by pulsatile flow depending on the presence of pericytes and astrocytes. Specifically, in the absence of perivascular support, brain ECs exhibit a stretched morphology with prominent actin stress fibers, while co‐culture with pericytes and astrocytes promotes endothelial rearrangement, leading to lumen formation and enhanced barrier properties. This study highlights the essential role of perivascular cells in modulating endothelial responses under microvascular confinement and physiologically relevant flow. These insights advance in vitro models of the neurovascular unit and BBB mechanobiology.


  • Open Access

    Electromagnetic Mode Management in Transparent DMD Electrodes for High Angular Color Stability in White OLEDs

    by Claudia Triolo, Antonella Lorusso, Sofia Masi, Fabrizio Mariano, Antonio Della Torre, Gianluca Accorsi, Valentina Arima, Stefano De Leo, Rosaria Rinaldi, Salvatore Patané, et al.

    The understanding and management of the optical behavior of dielectric/metal/dielectric (DMD)-based electrodes are crucial for the design of fully transparent OLEDs. Specifically, the chromatic stability with the viewing angle of white OLED emission remains an important issue due to the angle dependence of internal reflection at the organic/electrode interface as the wavelength varies. The purpose of the present work is to provide a complete analysis of the optical behavior of DMD structures by Variable Angle Spectroscopic Ellipsometry in order to optimize the transmittance of DMD-based transparent white OLEDs over a wide viewing angle. The analysis of the optical modes contributing to power dissipation reveals that the reduction of plasmonic and waveguided modes is related to the antireflection properties of the DMD electrode. This results in a simultaneous significant improvement in the absolute value of the transmittance across the full visible spectral range and in the color stability of white OLED emission over a wide viewing cone of 120°, thus paving the way for a new generation of transparent white lighting sources.


  • Open Access

    Controlling endotoxin contamination in PDMS-based microfluidic systems for organ-on-chip technologies

    by V. Guarino, E. Perrone, A. Zizzari, M. Bianco, G. Giancane, R. Rella, M.G. Manera, V. Arima


  • Open Access

    Glass Microdroplet Generator for Lipid-Based Double Emulsion Production

    by Alessandra Zizzari, Valentina Arima

    Microfluidics offers a highly controlled and reproducible route to synthesize lipid vesicles. In recent years, several microfluidic approaches have been introduced for this purpose, but double emulsions, such as Water-in-Oil-in-Water (W/O/W) droplets, are preferable to produce giant vesicles that are able to maximize material encapsulation. Flow focusing (FF) is a technique used to generate double emulsion droplets with high monodispersity, a controllable size, and good robustness. Many researchers use polydimethylsiloxane as a substrate material to fabricate microdroplet generators, but it has some limitations due to its hydrophobicity, incompatibility with organic solvents, and the molecular adsorption on the microchannel walls. Thus, specific surface modification and functionalization steps, which are uncomfortable to perform in closed microchannels, are required to overcome these shortcomings. Here, we propose glass as a material to produce a chip with a six-inlet junction geometry. The peculiar geometry and the glass physicochemical properties allow for W/O/W droplet formation without introducing microchannel wall functionalization and using a variety of reagents and organic solvents. The robust glass chip can be easily cleaned and used repeatedly, bringing advantages in terms of cost and reproducibility in emulsion preparation.


  • Open Access

    Catalase Detection via Membrane-Based Pressure Sensors

    by Monica Bianco, Alessandra Zizzari, Elisabetta Perrone, Diego Mangiullo, Marco Mazzeo, Ilenia Viola, Valentina Arima

    Membrane-based sensors (MePSs) exhibit remarkable precision and sensitivity in detecting pressure changes. MePSs are commonly used to monitor catalytic reactions in solution, generating gas products crucial for signal amplification in bioassays. They also allow for catalyst quantification by indirectly measuring the pressure generated by the gaseous products. This is particularly interesting for detecting enzymes in biofluids associated with disease onset. To enhance the performance of a MePS, various structural factors influence membrane flexibility and response time, ultimately dictating the device’s pressure sensitivity. In this study, we fabricated MePSs using polydimethylsiloxane (PDMS) and investigated how structural modifications affect the Young’s modulus (E) and residual stress (σ0) of the membranes. These modifications have a direct impact on the sensors’ sensitivity to pressure variations, observed as a function of the volume of the chamber (Σ) or of the mechanical properties of the membrane itself (S). MePSs exhibiting the highest sensitivities were then employed to detect catalyst quantities inducing the dismutation of hydrogen peroxide, producing dioxygen as a gaseous product. As a result, a catalase enzyme was successfully detected using these optimized MePSs, achieving a remarkable sensitivity of (22.7 ± 1.2) µm/nM and a limit of detection (LoD) of 396 pM.