Marie Teresa Nawka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Marie Teresa Nawka has a total of 171 co-authors. Here are the top co-authors by number of shared publications:
Jens Fiehler
9 shared publicationsJan-Hendrik Buhk
Affiliation Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
5 shared publications- Jens Fiehler
Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
4 shared publications Andreas Maximilian Frölich
Affiliation Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
3 shared publications- Gabriel Broocks
Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
3 shared publications - Lukas Meyer
Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
3 shared publications
Latest Publications
- Open Access
- 29 April 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (3) , 782-789
Higher risk of recurrence in partially thrombosed cerebral aneurysms post-WEB (Woven EndoBridge) device treatment: insights from the WorldWideWEB Consortium registry
Background The Woven EndoBridge (WEB) device is a prevalent treatment for intracranial aneurysms. While many studies have assessed the obliteration rate post-WEB embolization, few have focused on long-term outcomes in partially thrombosed aneurysms. Objective To assess whether partially thrombosed aneurysms are at higher risk of recurrence or retreatment following WEB embolization compared with non-thrombosed aneurysms. Methods We evaluated data from 22 academic institutions, focusing on previously untreated cerebral aneurysms treated with the WEB device. Logistic regression was utilized to analyze factors predicting long-term aneurysm obliteration and retreatment necessity. Results Among 1303 patients, 26 presented with a partially thrombosed aneurysm. In the partially thrombosed group, the mean aneurysm maximal diameter was 10.7±4 mm with a neck ratio of 1.99±1.19 mm, larger than in the control group where the mean aneurysm maximal diameter was 6.81±2.37 mm with a neck ratio of 1.64±0.51 mm (PConclusion Partially thrombosed aneurysms are associated with a poorer occlusion rate and a higher rate of retreatment following WEB embolization. For partially thrombosed aneurysms, the WEB device appears suboptimal as a first-line treatment, and therefore alternative techniques should be prioritized.
- 29 April 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (3) , 782-789
Open AccessHigher risk of recurrence in partially thrombosed cerebral aneurysms post-WEB (Woven EndoBridge) device treatment: insights from the WorldWideWEB Consortium registry
Background The Woven EndoBridge (WEB) device is a prevalent treatment for intracranial aneurysms. While many studies have assessed the obliteration rate post-WEB embolization, few have focused on long-term outcomes in partially thrombosed aneurysms. Objective To assess whether partially thrombosed aneurysms are at higher risk of recurrence or retreatment following WEB embolization compared with non-thrombosed aneurysms. Methods We evaluated data from 22 academic institutions, focusing on previously untreated cerebral aneurysms treated with the WEB device. Logistic regression was utilized to analyze factors predicting long-term aneurysm obliteration and retreatment necessity. Results Among 1303 patients, 26 presented with a partially thrombosed aneurysm. In the partially thrombosed group, the mean aneurysm maximal diameter was 10.7±4 mm with a neck ratio of 1.99±1.19 mm, larger than in the control group where the mean aneurysm maximal diameter was 6.81±2.37 mm with a neck ratio of 1.64±0.51 mm (PConclusion Partially thrombosed aneurysms are associated with a poorer occlusion rate and a higher rate of retreatment following WEB embolization. For partially thrombosed aneurysms, the WEB device appears suboptimal as a first-line treatment, and therefore alternative techniques should be prioritized.
- Open Access
- 1 February 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 108, 22-28
Hybrid dynamic bright and black blood angiography by non-contrast-enhanced vessel selective saturation angiography
- 1 February 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 108, 22-28
Open AccessHybrid dynamic bright and black blood angiography by non-contrast-enhanced vessel selective saturation angiography
- 18 January 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (e1) , e15-e24
The impact of postoperative aspirin in patients undergoing Woven EndoBridge: a multicenter, institutional, propensity score-matched analysis
Background The Woven EndoBridge (WEB) device is frequently used for the treatment of intracranial aneurysms. Postoperative management, including the use of aspirin, varies among clinicians and institutions, but its impact on the outcomes of the WEB has not been thoroughly investigated. Methods This was a retrospective, multicenter study involving 30 academic institutions in North America, South America, and Europe. Data from 1492 patients treated with the WEB device were included. Patients were categorized into two groups based on their postoperative use of aspirin (aspirin group: n=1124, non-aspirin group: n=368). Data points included patient demographics, aneurysm characteristics, procedural details, complications, and angiographic and functional outcomes. Propensity score matching (PSM) was applied to balance variables between the two groups. Results Prior to PSM, the aspirin group exhibited significantly higher rates of modified Rankin scale (mRS) mRS 0–1 and mRS 0–2 (89.8% vs 73.4% and 94.1% vs 79.8%, pConclusions Aspirin use post-WEB treatment may lead to better functional outcomes and lower mortality but with higher retreatment rates. These insights are crucial for postoperative management after WEB procedures, but further studies are necessary for validation.
- 18 January 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (e1) , e15-e24
The impact of postoperative aspirin in patients undergoing Woven EndoBridge: a multicenter, institutional, propensity score-matched analysis
Background The Woven EndoBridge (WEB) device is frequently used for the treatment of intracranial aneurysms. Postoperative management, including the use of aspirin, varies among clinicians and institutions, but its impact on the outcomes of the WEB has not been thoroughly investigated. Methods This was a retrospective, multicenter study involving 30 academic institutions in North America, South America, and Europe. Data from 1492 patients treated with the WEB device were included. Patients were categorized into two groups based on their postoperative use of aspirin (aspirin group: n=1124, non-aspirin group: n=368). Data points included patient demographics, aneurysm characteristics, procedural details, complications, and angiographic and functional outcomes. Propensity score matching (PSM) was applied to balance variables between the two groups. Results Prior to PSM, the aspirin group exhibited significantly higher rates of modified Rankin scale (mRS) mRS 0–1 and mRS 0–2 (89.8% vs 73.4% and 94.1% vs 79.8%, pConclusions Aspirin use post-WEB treatment may lead to better functional outcomes and lower mortality but with higher retreatment rates. These insights are crucial for postoperative management after WEB procedures, but further studies are necessary for validation.
- Open Access
- 15 August 2023
- Published by Wiley in Child: Care, Health and Development
- Vol. 50 (1)
Child‐centredness in paediatric magnetic resonance imaging: Information needs and experiences of children requiring magnetic resonance imaging and their parents
Background: Assessing patient experiences is essential to provide high quality health‐care. The objectives of this study were to examine (1) child‐ and parent‐reported information status before magnetic resonance imaging (MRI), (2) experiences during an MRI and (3) needs and suggestions for improvement.Methods: Children (≥8 years) and parents answered questionnaires (before and after planned MRI examination) covering mental condition, information status/needs, preparation for MRI, and potential stressors. Before MRI n = 132 accompanying parents and n = 91 children provided data (after MRI: n = 93 parents; n = 71 children). The mean age of the children undergoing MRI was 10.5 years (SD = 4.9). Children had on average seven previous MRIs before our survey (Range: 1–33). Twenty‐three percent of the children were to be sedated during the examination.Results: Parents and children reported low to medium levels of burden, high knowledge and high information status. For the children, most stressful factors during the MRI were boredom and noise. Main information resources were the radiologists or self‐searches. Parents of children with their first MRI reported higher anxiety levels in their children and stated a worse information status (main information source: self‐searches/internet).Parents reported needs regarding organization of the MRI (e.g., reduction of waiting times), age‐appropriate information and communication during the MRI. Children wished to visit the MRI room prior the examination (44%) and to get more information (44%). Children suggested improvements such as better sound quality of films/music, more transparency about the procedure, being in contact with a parent and shorter examinations.Conclusion: Results suggest that preparation, information provision and care is perceived positively by families. Needs and suggestions for improvement were, for example, higher transparency of procedures, better communication and reduction of stress. Findings indicate that preparation in routine‐care should follow an individualized child‐focused approach, should focus on families without previous MRIs and should address children with high anxiety levels.
- 15 August 2023
- Published by Wiley in Child: Care, Health and Development
- Vol. 50 (1)
Open AccessChild‐centredness in paediatric magnetic resonance imaging: Information needs and experiences of children requiring magnetic resonance imaging and their parents
Background: Assessing patient experiences is essential to provide high quality health‐care. The objectives of this study were to examine (1) child‐ and parent‐reported information status before magnetic resonance imaging (MRI), (2) experiences during an MRI and (3) needs and suggestions for improvement.Methods: Children (≥8 years) and parents answered questionnaires (before and after planned MRI examination) covering mental condition, information status/needs, preparation for MRI, and potential stressors. Before MRI n = 132 accompanying parents and n = 91 children provided data (after MRI: n = 93 parents; n = 71 children). The mean age of the children undergoing MRI was 10.5 years (SD = 4.9). Children had on average seven previous MRIs before our survey (Range: 1–33). Twenty‐three percent of the children were to be sedated during the examination.Results: Parents and children reported low to medium levels of burden, high knowledge and high information status. For the children, most stressful factors during the MRI were boredom and noise. Main information resources were the radiologists or self‐searches. Parents of children with their first MRI reported higher anxiety levels in their children and stated a worse information status (main information source: self‐searches/internet).Parents reported needs regarding organization of the MRI (e.g., reduction of waiting times), age‐appropriate information and communication during the MRI. Children wished to visit the MRI room prior the examination (44%) and to get more information (44%). Children suggested improvements such as better sound quality of films/music, more transparency about the procedure, being in contact with a parent and shorter examinations.Conclusion: Results suggest that preparation, information provision and care is perceived positively by families. Needs and suggestions for improvement were, for example, higher transparency of procedures, better communication and reduction of stress. Findings indicate that preparation in routine‐care should follow an individualized child‐focused approach, should focus on families without previous MRIs and should address children with high anxiety levels.
- 2 March 2022
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 90 (5) , 597-604
Impact of Woven EndoBridge Shape Modification on Aneurysm Recanalization at Short-Term Follow-up Digital Subtraction Angiography
BACKGROUND: Woven EndoBridge (WEB) shape modification (WSM) is a frequently observed phenomenon after aneurysm embolization. OBJECTIVE: To test our hypothesis that WSM is associated with worse aneurysm occlusion on short-term angiographic follow-up images. METHODS: Patients with short-term follow-up digital subtraction angiography (DSA) available were included. Baseline patient characteristics, aneurysm morphometrics, and WEB dimensions (“conventional” parameters) and height and width WSM (“WSM” parameters) in the initial and the follow-up examination were analyzed. For ordinal regression analyses, aneurysm occlusion was graded according to the Bicêtre Occlusion Scale Score (BOSS; grades 0, 0′, 1, 2, 3, and 1 + 3). Receiver operating characteristic curve analysis was used to distinguish adequately (BOSS 0, 0′, and 1) from incompletely (BOSS 2, 3, and 1 + 3) occluded aneurysms. RESULTS: We included 93 patients with 96 aneurysms. Adequate occlusion was observed in 72 cases (75.0%). In univariate ordinal regression analysis, width WSM in anteroposterior DSA (odds ratio = 0.96, 95% CI: 0.94-0.99, P = .010) and in lateral DSA (odds ratio = 0.98, 95% CI: 0.97-0.99, P = .049) were significantly associated with the BOSS after 6 months. In multivariate regression analysis, WSM was not independently associated with aneurysm occlusion. Based on receiver operating characteristic curve analysis, the area under the curve (AUC) of the “conventional” model (AUC = 0.83, 95% CI 0.74-0.90) was higher than the AUC of the “WSM” model (WSM; AUC = 0.70, 95% CI 0.60-0.79). CONCLUSION: WSM was not independently associated with angiographic aneurysm occlusion status after 6 months. However, the “conventional” parameters including sex, rupture state, WEB type, WEB width, aneurysm width, height, and volume were associated with partial aneurysm recanalization in WEB-treated patients at the short-term follow-up.
- 2 March 2022
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 90 (5) , 597-604
Impact of Woven EndoBridge Shape Modification on Aneurysm Recanalization at Short-Term Follow-up Digital Subtraction Angiography
BACKGROUND: Woven EndoBridge (WEB) shape modification (WSM) is a frequently observed phenomenon after aneurysm embolization. OBJECTIVE: To test our hypothesis that WSM is associated with worse aneurysm occlusion on short-term angiographic follow-up images. METHODS: Patients with short-term follow-up digital subtraction angiography (DSA) available were included. Baseline patient characteristics, aneurysm morphometrics, and WEB dimensions (“conventional” parameters) and height and width WSM (“WSM” parameters) in the initial and the follow-up examination were analyzed. For ordinal regression analyses, aneurysm occlusion was graded according to the Bicêtre Occlusion Scale Score (BOSS; grades 0, 0′, 1, 2, 3, and 1 + 3). Receiver operating characteristic curve analysis was used to distinguish adequately (BOSS 0, 0′, and 1) from incompletely (BOSS 2, 3, and 1 + 3) occluded aneurysms. RESULTS: We included 93 patients with 96 aneurysms. Adequate occlusion was observed in 72 cases (75.0%). In univariate ordinal regression analysis, width WSM in anteroposterior DSA (odds ratio = 0.96, 95% CI: 0.94-0.99, P = .010) and in lateral DSA (odds ratio = 0.98, 95% CI: 0.97-0.99, P = .049) were significantly associated with the BOSS after 6 months. In multivariate regression analysis, WSM was not independently associated with aneurysm occlusion. Based on receiver operating characteristic curve analysis, the area under the curve (AUC) of the “conventional” model (AUC = 0.83, 95% CI 0.74-0.90) was higher than the AUC of the “WSM” model (WSM; AUC = 0.70, 95% CI 0.60-0.79). CONCLUSION: WSM was not independently associated with angiographic aneurysm occlusion status after 6 months. However, the “conventional” parameters including sex, rupture state, WEB type, WEB width, aneurysm width, height, and volume were associated with partial aneurysm recanalization in WEB-treated patients at the short-term follow-up.
- Open Access
- 25 January 2022
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 15 (1) , 8-13
Benefit and risk of intravenous alteplase in patients with acute large vessel occlusion stroke and low ASPECTS
Background The benefit of best medical treatment including intravenous alteplase (IVT) before mechanical thrombectomy (MT) in patients with acute ischemic stroke and extensive early ischemic changes on baseline CT remains uncertain. The purpose of this study was to evaluate the benefit of IVT for patients with low ASPECTS (Alberta Stroke Programme Early CT Score) compared with patients with or without MT. Methods This multicenter study pooled consecutive patients with anterior circulation acute stroke and ASPECTS≤5 to analyze the impact of IVT on functional outcome, and to compare bridging IVT with direct MT. Functional endpoints were the rates of good (modified Rankin Scale (mRS) score ≤2) and very poor (mRS ≥5) outcome at day 90. Safety endpoint was the occurrence of symptomatic intracranial hemorrhage (sICH). Results 429 patients were included. 290 (68%) received IVT and 168 (39%) underwent MT. The rate of good functional outcome was 14.4% (95% CI 7.1% to 21.8%) for patients who received bridging IVT and 24.4% (95% CI 16.5% to 32.2%) for those who underwent direct MT. The rate of sICH was significantly higher in patients with bridging IVT compared with direct MT (17.8% vs 6.4%, p=0.004). In multivariable logistic regression analysis, IVT was significantly associated with very poor outcome (OR 2.22, 95% CI 1.05 to 4.73, p=0.04) and sICH (OR 3.44, 95% CI 1.18 to 10.07, p=0.02). Successful recanalization, age, and ASPECTS were associated with good functional outcome. Conclusions Bridging IVT in patients with low ASPECTS was associated with very poor functional outcome and an increased risk of sICH. The benefit of this treatment should therefore be carefully weighed in such scenarios. Further randomized controlled trials are required to validate our findings.
- 25 January 2022
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 15 (1) , 8-13
Open AccessBenefit and risk of intravenous alteplase in patients with acute large vessel occlusion stroke and low ASPECTS
Background The benefit of best medical treatment including intravenous alteplase (IVT) before mechanical thrombectomy (MT) in patients with acute ischemic stroke and extensive early ischemic changes on baseline CT remains uncertain. The purpose of this study was to evaluate the benefit of IVT for patients with low ASPECTS (Alberta Stroke Programme Early CT Score) compared with patients with or without MT. Methods This multicenter study pooled consecutive patients with anterior circulation acute stroke and ASPECTS≤5 to analyze the impact of IVT on functional outcome, and to compare bridging IVT with direct MT. Functional endpoints were the rates of good (modified Rankin Scale (mRS) score ≤2) and very poor (mRS ≥5) outcome at day 90. Safety endpoint was the occurrence of symptomatic intracranial hemorrhage (sICH). Results 429 patients were included. 290 (68%) received IVT and 168 (39%) underwent MT. The rate of good functional outcome was 14.4% (95% CI 7.1% to 21.8%) for patients who received bridging IVT and 24.4% (95% CI 16.5% to 32.2%) for those who underwent direct MT. The rate of sICH was significantly higher in patients with bridging IVT compared with direct MT (17.8% vs 6.4%, p=0.004). In multivariable logistic regression analysis, IVT was significantly associated with very poor outcome (OR 2.22, 95% CI 1.05 to 4.73, p=0.04) and sICH (OR 3.44, 95% CI 1.18 to 10.07, p=0.02). Successful recanalization, age, and ASPECTS were associated with good functional outcome. Conclusions Bridging IVT in patients with low ASPECTS was associated with very poor functional outcome and an increased risk of sICH. The benefit of this treatment should therefore be carefully weighed in such scenarios. Further randomized controlled trials are required to validate our findings.
- 1 January 2022
- Published by Wolters Kluwer Health in Stroke
- Vol. 53 (1) , 201-209
Quantitative Lesion Water Uptake as Stroke Imaging Biomarker: A Tool for Treatment Selection in the Extended Time Window?
Background and Purpose: Patients presenting in the extended time window may benefit from mechanical thrombectomy. However, selection for mechanical thrombectomy in this patient group has only been performed using specialized image processing platforms, which are not widely available. We hypothesized that quantitative lesion water uptake calculated in acute stroke computed tomography (CT) may serve as imaging biomarker to estimate ischemic lesion progression and predict clinical outcome in patients undergoing mechanical thrombectomy in the extended time window. Methods: All patients with ischemic anterior circulation stroke presenting within 4.5 to 24 hours after symptom onset who received initial multimodal CT between August 2014 and March 2020 and underwent mechanical thrombectomy were analyzed. Quantitative lesion net water uptake was calculated from the admission CT. Prediction of clinical outcome was assessed using univariable receiver operating characteristic curve analysis and logistic regression analyses. Results: One hundred two patients met the inclusion criteria. In the multivariable logistic regression analysis, net water uptake (odds ratio, 0.78 [95% CI, 0.64–0.95], P =0.01), age (odds ratio, 0.94 [95% CI, 0.88–0.99]; P =0.02), and National Institutes of Health Stroke Scale (odds ratio, 0.88 [95% CI, 0.79–0.99], P =0.03) were significantly and independently associated with favorable outcome (modified Rankin Scale score ≤1), adjusted for degree of recanalization and Alberta Stroke Program Early CT Score. A multivariable predictive model including the above parameters yielded the highest diagnostic ability in the classification of functional outcome, with an area under the curve of 0.88 (sensitivity 92.3%, specificity 82.9%). Conclusions: The implementation of quantitative lesion water uptake as imaging biomarker in the diagnosis of patients with ischemic stroke presenting in the extended time window might improve clinical prognosis. Future studies could test this biomarker as complementary or even alternative tool to CT perfusion.
- 1 January 2022
- Published by Wolters Kluwer Health in Stroke
- Vol. 53 (1) , 201-209
Quantitative Lesion Water Uptake as Stroke Imaging Biomarker: A Tool for Treatment Selection in the Extended Time Window?
Background and Purpose: Patients presenting in the extended time window may benefit from mechanical thrombectomy. However, selection for mechanical thrombectomy in this patient group has only been performed using specialized image processing platforms, which are not widely available. We hypothesized that quantitative lesion water uptake calculated in acute stroke computed tomography (CT) may serve as imaging biomarker to estimate ischemic lesion progression and predict clinical outcome in patients undergoing mechanical thrombectomy in the extended time window. Methods: All patients with ischemic anterior circulation stroke presenting within 4.5 to 24 hours after symptom onset who received initial multimodal CT between August 2014 and March 2020 and underwent mechanical thrombectomy were analyzed. Quantitative lesion net water uptake was calculated from the admission CT. Prediction of clinical outcome was assessed using univariable receiver operating characteristic curve analysis and logistic regression analyses. Results: One hundred two patients met the inclusion criteria. In the multivariable logistic regression analysis, net water uptake (odds ratio, 0.78 [95% CI, 0.64–0.95], P =0.01), age (odds ratio, 0.94 [95% CI, 0.88–0.99]; P =0.02), and National Institutes of Health Stroke Scale (odds ratio, 0.88 [95% CI, 0.79–0.99], P =0.03) were significantly and independently associated with favorable outcome (modified Rankin Scale score ≤1), adjusted for degree of recanalization and Alberta Stroke Program Early CT Score. A multivariable predictive model including the above parameters yielded the highest diagnostic ability in the classification of functional outcome, with an area under the curve of 0.88 (sensitivity 92.3%, specificity 82.9%). Conclusions: The implementation of quantitative lesion water uptake as imaging biomarker in the diagnosis of patients with ischemic stroke presenting in the extended time window might improve clinical prognosis. Future studies could test this biomarker as complementary or even alternative tool to CT perfusion.
- Open Access
- 4 June 2021
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 32 (1) , 89-97
Woven EndoBridge (WEB) Width at the Aneurysm Neck Level Affects Early Angiographic Aneurysm Occlusion
Purpose: Endovascular therapy with the Woven EndoBridge (WEB) device is a safe treatment approach, whereby neoendothelialization at the neck area is a crucial element for aneurysm occlusion. We hypothesized that WEB sizing at the aneurysmal neck level has an impact on early aneurysm occlusion. Methods: Patients with short-term follow-up digital subtraction angiography following WEB treatment of unruptured aneurysms were included. Aneurysms were categorized according to the Bicêtre Occlusion Scale Score (BOSS) as adequately (BOSS 0, 0′, 1) or partially occluded (BOSS 2, 3, 1 + 3). The WEB device dimensions, including the average aneurysm diameter (AADi) and the average neck diameter (ANDi) as well as baseline patient characteristics were documented. Results: In this study 75 patients with 76 aneurysms were included and 65 aneurysms showed adequate occlusion at short-term follow-up (86%). In univariable logistic regression analysis, smaller differences in WEB size to ANDi (D-ANDi) were significantly associated with adequate aneurysm occlusion (odds ratio, OR = 0.41, 95% confidence interval, CI 0.23–0.71, p = 0.002). Receiver operating characteristic (ROC) curve analyses displayed higher discriminative power for the D‑ANDi (AUC = 0.77, 95% CI 0.66–0.86, cut-off ≤2.9 mm) compared to the difference in WEB size to the average aneurysm diameter (D-AADi, AUC = 0.65, 95% CI 0.53–0.75, cut-off ≤1.0 mm). Conclusion: Smaller differences between the WEB width and ANDi were associated with adequate early aneurysm occlusion and might thus have a higher impact on the results than the traditional device sizing considering the mean aneurysm diameter. D‑ANDi ≤2.9 mm served as an optimal cut-off to classify occlusion after WEB treatment at the short-term follow-up. Further external validation is warranted.
- 4 June 2021
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 32 (1) , 89-97
Open AccessWoven EndoBridge (WEB) Width at the Aneurysm Neck Level Affects Early Angiographic Aneurysm Occlusion
Purpose: Endovascular therapy with the Woven EndoBridge (WEB) device is a safe treatment approach, whereby neoendothelialization at the neck area is a crucial element for aneurysm occlusion. We hypothesized that WEB sizing at the aneurysmal neck level has an impact on early aneurysm occlusion. Methods: Patients with short-term follow-up digital subtraction angiography following WEB treatment of unruptured aneurysms were included. Aneurysms were categorized according to the Bicêtre Occlusion Scale Score (BOSS) as adequately (BOSS 0, 0′, 1) or partially occluded (BOSS 2, 3, 1 + 3). The WEB device dimensions, including the average aneurysm diameter (AADi) and the average neck diameter (ANDi) as well as baseline patient characteristics were documented. Results: In this study 75 patients with 76 aneurysms were included and 65 aneurysms showed adequate occlusion at short-term follow-up (86%). In univariable logistic regression analysis, smaller differences in WEB size to ANDi (D-ANDi) were significantly associated with adequate aneurysm occlusion (odds ratio, OR = 0.41, 95% confidence interval, CI 0.23–0.71, p = 0.002). Receiver operating characteristic (ROC) curve analyses displayed higher discriminative power for the D‑ANDi (AUC = 0.77, 95% CI 0.66–0.86, cut-off ≤2.9 mm) compared to the difference in WEB size to the average aneurysm diameter (D-AADi, AUC = 0.65, 95% CI 0.53–0.75, cut-off ≤1.0 mm). Conclusion: Smaller differences between the WEB width and ANDi were associated with adequate early aneurysm occlusion and might thus have a higher impact on the results than the traditional device sizing considering the mean aneurysm diameter. D‑ANDi ≤2.9 mm served as an optimal cut-off to classify occlusion after WEB treatment at the short-term follow-up. Further external validation is warranted.
- 9 November 2020
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (10) , 869-874
Computed tomography-based triage of extensive baseline infarction: ASPECTS and collaterals versus perfusion imaging for outcome prediction
Background Patients presenting with large baseline infarctions are often excluded from mechanical thrombectomy (MT) due to uncertainty surrounding its effect on outcome. We hypothesized that computed tomography perfusion (CTP)-based selection may be predictive of functional outcome in low Alberta Stroke Program Early CT Score (ASPECTS) patients. Methods This was a double-center, retrospective analysis of patients presenting with ASPECTS≤5 who received multimodal admission CT imaging between May 2015 and June 2020. The predicted ischemic core (pCore) was defined as a reduction in cerebral blood flow (rCBF), while mismatch volume was defined using time to maximum (Tmax). The pCore perfusion mismatch ratio (CPMR) was also calculated. These parameters (pCore, mismatch volume, and CPMR), as well as a combined radiological score consisting of ASPECTS and collateral status (ASCO score), were tested in logistic regression and receiver operating characteristic (ROC) analyses. The primary outcome was favorable modified Rankin Scale (mRS) at discharge (≤3). Results A total of 113 patients met the inclusion criteria. The median ischemic core volume was 74.1 mL (IQR 43.8–121.8). The ASCO score was associated with favorable outcome at discharge (aOR 3.7, 95% CI 1.8 to 10.7, P=0.002), while no association was observed for the CTP parameters. A model including the ASCO score also had significantly higher area under the curve (AUC) values compared with the CTP-based model (0.88 vs 0.64, P=0.018). Conclusions The ASCO score was superior to the CTP-based model for the prediction of good functional outcome and could represent a quick, practical, and easily implemented method for the selection of low ASPECTS patients most likely benefit from MT.
- 9 November 2020
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (10) , 869-874
Computed tomography-based triage of extensive baseline infarction: ASPECTS and collaterals versus perfusion imaging for outcome prediction
Background Patients presenting with large baseline infarctions are often excluded from mechanical thrombectomy (MT) due to uncertainty surrounding its effect on outcome. We hypothesized that computed tomography perfusion (CTP)-based selection may be predictive of functional outcome in low Alberta Stroke Program Early CT Score (ASPECTS) patients. Methods This was a double-center, retrospective analysis of patients presenting with ASPECTS≤5 who received multimodal admission CT imaging between May 2015 and June 2020. The predicted ischemic core (pCore) was defined as a reduction in cerebral blood flow (rCBF), while mismatch volume was defined using time to maximum (Tmax). The pCore perfusion mismatch ratio (CPMR) was also calculated. These parameters (pCore, mismatch volume, and CPMR), as well as a combined radiological score consisting of ASPECTS and collateral status (ASCO score), were tested in logistic regression and receiver operating characteristic (ROC) analyses. The primary outcome was favorable modified Rankin Scale (mRS) at discharge (≤3). Results A total of 113 patients met the inclusion criteria. The median ischemic core volume was 74.1 mL (IQR 43.8–121.8). The ASCO score was associated with favorable outcome at discharge (aOR 3.7, 95% CI 1.8 to 10.7, P=0.002), while no association was observed for the CTP parameters. A model including the ASCO score also had significantly higher area under the curve (AUC) values compared with the CTP-based model (0.88 vs 0.64, P=0.018). Conclusions The ASCO score was superior to the CTP-based model for the prediction of good functional outcome and could represent a quick, practical, and easily implemented method for the selection of low ASPECTS patients most likely benefit from MT.
- Open Access
- 17 September 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (9) , e0238952
Feasibility of a customizable training environment for neurointerventional skills assessment
To meet increasing demands to train neuroendovascular techniques, we developed a dedicated simulator applying individualized three-dimensional intracranial aneurysm models (‘HANNES’; Hamburg Anatomic Neurointerventional Endovascular Simulator). We hypothesized that HANNES provides a realistic and reproducible training environment to practice coil embolization and to exemplify disparities between neurointerventionalists, thus objectively benchmarking operators at different levels of experience. Six physicians with different degrees of neurointerventional procedural experience were recruited into a standardized training protocol comprising catheterization of two internal carotid artery (ICA) aneurysms and one basilar tip aneurysm, followed by introduction of one framing coil into each aneurysm and finally complete coil embolization of one determined ICA aneurysm. The level of difficulty increased with every aneurysm. Fluoroscopy was recorded and assessed for procedural characteristics and adverse events. Physicians were divided into inexperienced and experienced operators, depending on their experience with microcatheter handling. Mean overall catheterization times increased with difficulty of the aneurysm model. Inexperienced operators showed longer catheterization times (median; IQR: 47; 30-84s) than experienced operators (21; 13-58s, p = 0.011) and became significantly faster during the course of the attempts (rho = -0.493, p = 0.009) than the experienced physicians (rho = -0.318, p = 0.106). Number of dangerous maneuvers throughout all attempts was significantly higher for inexperienced operators (median; IQR: 1.0; 0.0–1.5) as compared to experienced operators (0.0; 0.0–1.0, p = 0.014). HANNES represents a modular neurointerventional training environment for practicing aneurysm coil embolization in vitro. Objective procedural metrics correlate with operator experience, suggesting that the system could be useful for assessing operator proficiency.
- 17 September 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (9) , e0238952
Open AccessFeasibility of a customizable training environment for neurointerventional skills assessment
To meet increasing demands to train neuroendovascular techniques, we developed a dedicated simulator applying individualized three-dimensional intracranial aneurysm models (‘HANNES’; Hamburg Anatomic Neurointerventional Endovascular Simulator). We hypothesized that HANNES provides a realistic and reproducible training environment to practice coil embolization and to exemplify disparities between neurointerventionalists, thus objectively benchmarking operators at different levels of experience. Six physicians with different degrees of neurointerventional procedural experience were recruited into a standardized training protocol comprising catheterization of two internal carotid artery (ICA) aneurysms and one basilar tip aneurysm, followed by introduction of one framing coil into each aneurysm and finally complete coil embolization of one determined ICA aneurysm. The level of difficulty increased with every aneurysm. Fluoroscopy was recorded and assessed for procedural characteristics and adverse events. Physicians were divided into inexperienced and experienced operators, depending on their experience with microcatheter handling. Mean overall catheterization times increased with difficulty of the aneurysm model. Inexperienced operators showed longer catheterization times (median; IQR: 47; 30-84s) than experienced operators (21; 13-58s, p = 0.011) and became significantly faster during the course of the attempts (rho = -0.493, p = 0.009) than the experienced physicians (rho = -0.318, p = 0.106). Number of dangerous maneuvers throughout all attempts was significantly higher for inexperienced operators (median; IQR: 1.0; 0.0–1.5) as compared to experienced operators (0.0; 0.0–1.0, p = 0.014). HANNES represents a modular neurointerventional training environment for practicing aneurysm coil embolization in vitro. Objective procedural metrics correlate with operator experience, suggesting that the system could be useful for assessing operator proficiency.