LSLars Schiøtt Sørensen

Lars Schiøtt Sørensen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lars Schiøtt Sørensen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Novel and legacy brominated flame retardants in human breast milk and house dust from Denmark

    by Stephanie C. Hammel, Katrin Vorkamp, Jesper Bo Nielsen, Lars S. Sørensen, Lisbeth E. Knudsen, Marie Frederiksen

    A suite of novel brominated flame retardants (NBFRs), hexabromocyclododecanes (HBCDDs), polybrominated diphenyl ethers (PBDEs) and dechlorane plus were measured in matched samples of house dust (n = 47) and human breast milk (n = 40) from Denmark sampled in 2007, i.e., shortly after PBDE restrictions were implemented in Europe providing a valuable reference point. The most abundant BFR in breast milk was BDE-153 with a median concentration of 0.79 ng/g lipid followed by BDE-47 (median: 0.61 ng/g lipid) and BDE-209 (median: 0.53 ng/g lipid). Levels of bis(2-ethylhexyl) tetrabromophthalate (BEH-TEBP) were comparable (median: 0.78 ng/g lipid); however, they were based on fewer samples. α-HBCDD was the most abundant HBCDD in breast milk (median: 0.24 ng/g lipid) and detected in all samples. The house dust samples were dominated by BDE-209 (median: 432 ng/g) and γ-HBCDD (median: 177 ng/g); among the NBFRs, the highest levels were found for decabromodiphenyl ethane (DBDPE) (median: 86.2 ng/g) and BEH-TEBP (median: 26.7 ng/g). BDE-28, 47 and 153 were significantly correlated between breast milk and serum (rs = 0.73-0.81, P < 0.0001); however, this was not the case for any of the NBFRs. Intake estimates for a 3-month-old infant indicated that for most of the flame retardants, breast milk was by far the dominant route of exposure, whereas dust only contributed substantially for BDE-209, γ-HBCDD, and to some extent α-HBCDD. This study is the first to report on human exposure to NBFRs in Denmark and shows that internal exposure levels of NBFRs were similar to those of most PBDEs already at the time of PBDE restrictions.


  • Open Access

    Dermal uptake and percutaneous penetration of organophosphate esters in a human skin ex vivo model

    by Marie Frederiksen, Heather M. Stapleton, Katrin Vorkamp, Thomas F. Webster, Niels Martin Jensen, Jens Ahm Sørensen, Flemming Nielsen, Lisbeth E. Knudsen, Lars S. Sørensen, Per Axel Clausen, et al.


  • Fire resistance of extruded hollow-core slabs

    by Kristian Hertz, Luisa Giuliani, Lars Schiøtt Sørensen

    Purpose: Prefabricated extruded hollow-core slabs are preferred building components for floor structures in several countries. It is therefore important to be able to document the fire resistance of these slabs proving fulfilment of standard fire resistance requirements of 60 and 120 min found in most national building regulations. The paper aims to present a detailed analysis of the mechanisms responsible for the loss of load-bearing capacity of hollow-core slabs when exposed to fire. Design/methodology/approach: Furthermore, it compares theoretical calculation and assessment according to the structural codes with data derived from a standard fire test and from a thorough examination of the comprehensive test documentation available on fire exposed hollow-core slabs. Findings: Mechanisms for loss of load-bearing capacity are clarified, and evidence of the fire resistance is found. Originality value: For the first time, the mechanisms responsible for loss of load-bearing capacity are identified, and test results and calculation approach are for the first time applied in accordance with each other for assessment of fire resistance of the structure.


  • Dermal uptake and percutaneous penetration of ten flame retardants in a human skin ex vivo model

    by Marie Frederiksen, Katrin Vorkamp, Niels Martin Jensen, Jens Ahm Sørensen, Lisbeth E. Knudsen, Lars S. Sørensen, Thomas F. Webster, Jesper B. Nielsen


  • Open Access

    Heat Transmission Coefficient Measurements in Buildings Utilizing a Heat Loss Measuring Device

    by Lars Schiøtt Sørensen

    Global energy efficiency can be obtained in two ordinary ways. One way is to improve the energy production and supply side, and the other way is, in general, to reduce the consumption of energy in society. This paper has focus on the latter and especially the consumption of energy for heating and cooling our houses. There is a huge energy-saving potential in this area for reducing both the global climate problems as well as economy challenges. Heating of buildings in Denmark accounts for approximately 40% of the entire national energy consumption. For this reason, a reduction of heat losses from building envelopes are of great importance in order to reach the Bologna CO2 emission reduction targets. Upgrading of the energy performance of buildings is a topic of huge global interest these years. Not only heating in the temperate and arctic regions are important, but also air conditioning and mechanical ventilation in the “warm countries” contribute to an enormous energy consumption and corresponding CO2 emission. In order to establish the best basis for upgrading the energy performance, it is important to make measurements of the heat losses at different places on a building facade, in order to optimize the energy performance. This paper presents a method for measuring the heat loss by utilizing a U-value meter. The U-value meter measures the heat transfer in the unit W/Km2 and has been used in several projects to upgrade the energy performance in temperate regions. The U-value meter was also utilized in an EUDP (Energy Technological Development and Demonstration Program) focusing on renovation of houses from the 1960s and 1970s.


  • Open Access

    Energy Reduction in Buildings in Tempered and Tropic Regions Utilizing a Heat Loss Measuring Device (U-value Meter)

    by Lars Sørensen

    There exist two ordinary ways to obtain global energy efficiency. One way is to make improvements on the energy production and supply side, and the other way is, in general, to reduce the consume of energy in the society. This paper has focus on the latter and especially the consume of energy for heating up, and cooling down our houses. There is a huge energy saving potential on this area reducing both the World climate problems and economy challenges as well. Heating of buildings in Denmark counts for approximately 40% of the entire national energy consume. Of this reason a reduction of heat losses from building envelopes are of great impor­tance in order to reach the Bologna CO2-emission reduction goals. Energy renovation of buildings is a topic of huge focus around the world these years. Not only expenses for heating in the tempered and arctic regions are of importance, but also expenses to ACMV in the "warm countries" contribute to an enormous energy consumption and corresponding CO2 emission. In order to establish the best basis for energy renovation, it is important to have measures of the heat losses on a building façade, for optimizing the energy renovation. This paper will present a new method for measuring the heat loss by utilizing a so called U-value Meter [Sørensen 2010]. The U-value Meter is a heat loss measuring device and has been used in several energy renovation projects in tempered regions and is now planned to be utilized in the tropics for measuring the heat penetration through facades with the aim to reduce the costs to AC. The paper will introduce a common project between NUS (National University of Singapore), AAU (Aalborg University) and HT-Meter, the latter as the U-value Meter developer company. In the project we will measure the heat transfer in the unit W/Km2 through different facade elements, such as outer walls, entrance doors, windows and roofs on selected buildings. The results will be analysed as basic for improvements of the envelope. A developing of new energy renovation systems and energy renovation principles is expected to be the outcome of the project. Furthermore this paper present results from already conducted heat loss measurements in the tempered regions and discusses the U-value Meter device aiming for improvements.