Yuzuru Shimazaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuzuru Shimazaki has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Shinzaburo Ito
Department of Polymer Chemistry, Graduate School of Engineering, Kyoto University, Sakyo, Kyoto 606-8501, Japan
6 shared publicationsYoshio Kobayashi
6 shared publicationsMasahide Yamamoto
Department of Polymer Chemistry, Graduate School of Engineering, Kyoto University, Sakyo, Kyoto 606-8501, Japan
5 shared publicationsMasaya Mitsuishi
Department of Polymer Chemistry, Graduate School of Engineering, Kyoto University, Yoshida, Sakyo, Kyoto 606-8501, Japan
4 shared publicationsMikio Konno
4 shared publicationsAkihiro Miyauchi
3 shared publications
Latest Publications
- 8 February 2021
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 60 (3) , 037002
Dense array of floating water droplets aligned to an assembly of tubular wells
A dense array of surfactant-stabilized water droplets (20 μ m in diameter) floating on the surface of fluorinated oil was prepared. More than 30000 droplets were planarly arrayed in an 8 mm squared area using the “droplet guide”, an assembly of tubular wells located on the top wall of the fluidic channel. Parallel measurement of the melting temperatures of digitally partitioned KRAS DNAs hybridized with molecular beacons was demonstrated using the array of floating droplets.
- 8 February 2021
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 60 (3) , 037002
Dense array of floating water droplets aligned to an assembly of tubular wells
A dense array of surfactant-stabilized water droplets (20 μ m in diameter) floating on the surface of fluorinated oil was prepared. More than 30000 droplets were planarly arrayed in an 8 mm squared area using the “droplet guide”, an assembly of tubular wells located on the top wall of the fluidic channel. Parallel measurement of the melting temperatures of digitally partitioned KRAS DNAs hybridized with molecular beacons was demonstrated using the array of floating droplets.
- 7 August 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (17) , 11705-11713
10-Plex Digital Polymerase Chain Reaction with Four-Color Melting Curve Analysis for Simultaneous KRAS and BRAF Genotyping
Digital PCR (dPCR) is a promising method for performing liquid biopsies that quantifies nucleic acids more sensitively than real-time PCR. However, dPCR shows large fluctuations in the fluorescence intensity of droplets or wells due to insufficient PCR amplification in the small partitions, limiting the multiplexing capability of using the fluorescence intensity. In this study, we propose a measurement method that combines dPCR with melting curve analysis for highly multiplexed genotyping. A sample was digitized into a silicon chip with up to 2x104 wells in which asymmetric PCR was performed to obtain more single-stranded amplicons that were complimentary to molecular beacon probes. Fluorescence images were captured while controlling the temperature of the chip, and the melting curve was measured for each well. Then, genotyping was performed by using the fluorescence intensity, the dye color of the probe, and the melting temperature (Tm). Because the Tm of the PCR products is not highly dependent on the amplification efficiency of PCR, genotyping accuracy is improved by using Tm values, enabling highly multiplexed genotyping. The concept was confirmed by simultaneously identifying wild-type KRAS, BRAF and, eight mutants of these genes (G12D, G12R, G12V, G13D, G12A, G12C, G12S, and V600E) through four-color melting curve analysis. To the best of our knowledge, this is the first demonstration of the genotyping of ten DNA groups including single mutations of cancer-related genes by combining dPCR with four-color melting curve analysis.
- 7 August 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (17) , 11705-11713
10-Plex Digital Polymerase Chain Reaction with Four-Color Melting Curve Analysis for Simultaneous KRAS and BRAF Genotyping
Digital PCR (dPCR) is a promising method for performing liquid biopsies that quantifies nucleic acids more sensitively than real-time PCR. However, dPCR shows large fluctuations in the fluorescence intensity of droplets or wells due to insufficient PCR amplification in the small partitions, limiting the multiplexing capability of using the fluorescence intensity. In this study, we propose a measurement method that combines dPCR with melting curve analysis for highly multiplexed genotyping. A sample was digitized into a silicon chip with up to 2x104 wells in which asymmetric PCR was performed to obtain more single-stranded amplicons that were complimentary to molecular beacon probes. Fluorescence images were captured while controlling the temperature of the chip, and the melting curve was measured for each well. Then, genotyping was performed by using the fluorescence intensity, the dye color of the probe, and the melting temperature (Tm). Because the Tm of the PCR products is not highly dependent on the amplification efficiency of PCR, genotyping accuracy is improved by using Tm values, enabling highly multiplexed genotyping. The concept was confirmed by simultaneously identifying wild-type KRAS, BRAF and, eight mutants of these genes (G12D, G12R, G12V, G13D, G12A, G12C, G12S, and V600E) through four-color melting curve analysis. To the best of our knowledge, this is the first demonstration of the genotyping of ten DNA groups including single mutations of cancer-related genes by combining dPCR with four-color melting curve analysis.
- 31 May 2019
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 1 (8) , 1925-1929
Design of Thermoresponsive Polymers Toward Antibody Purification
- 31 May 2019
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 1 (8) , 1925-1929
Design of Thermoresponsive Polymers Toward Antibody Purification
- 25 April 2019
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 58 (SD) , SDDJ01
Effect of bumps on the stability of water droplets on the pillar surface
The effect of small bumps on the state of water droplets was investigated experimentally on the hydrophobic surfaces of pillars with a controlled size. The bump-introduced pillar surfaces were fabricated by the UV-imprinting technique on the SiO 2 nanoparticle/resin composite and the partial removal of the resin by O 2 etching. Water droplets showed a large contact angle on the pillar surfaces with the bumps. However, on the pillar surfaces without the bumps, the contact angle decreased with the increase in the distance between pillars. These results clearly indicate that the bumps stabilize hydrophobicity on the pillar surface.
- 25 April 2019
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 58 (SD) , SDDJ01
Effect of bumps on the stability of water droplets on the pillar surface
The effect of small bumps on the state of water droplets was investigated experimentally on the hydrophobic surfaces of pillars with a controlled size. The bump-introduced pillar surfaces were fabricated by the UV-imprinting technique on the SiO 2 nanoparticle/resin composite and the partial removal of the resin by O 2 etching. Water droplets showed a large contact angle on the pillar surfaces with the bumps. However, on the pillar surfaces without the bumps, the contact angle decreased with the increase in the distance between pillars. These results clearly indicate that the bumps stabilize hydrophobicity on the pillar surface.
- Open Access
- 22 February 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
KRAS genotyping by digital PCR combined with melting curve analysis
Digital PCR (dPCR) has been developed as a method that can quantify nucleic acids more sensitively than real-time PCR. However, dPCR exhibits large fluctuations in the fluorescence intensity of the compartment, resulting in low accuracy. The main cause is most likely due to insufficient PCR. In this study, we proposed a new method that combines dPCR with melting curve analysis and applied that method to KRAS genotyping. Since the melting temperature (Tm) of the PCR product hardly depends on the amplification efficiency, genotyping accuracy is improved by using the Tm value. The results showed that the peaks of the distribution of the Tm values of DNA in the wells were 68.7, 66.3, and 62.6 °C for wild-type KRAS, the G12R mutant, and the G12D mutant, respectively, and the standard deviation of the Tm values was 0.2 °C for each genotype. This result indicates that the proposed method is capable of discriminating between the wild-type sequence and the two mutants. To the best of our knowledge, this is the first demonstration of the genotyping of single mutations by combining melting curve analysis and dPCR. The application of this approach could be useful for the quantification and genotyping of cancer-related genes in low-abundance samples.
- 22 February 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
Open AccessKRAS genotyping by digital PCR combined with melting curve analysis
Digital PCR (dPCR) has been developed as a method that can quantify nucleic acids more sensitively than real-time PCR. However, dPCR exhibits large fluctuations in the fluorescence intensity of the compartment, resulting in low accuracy. The main cause is most likely due to insufficient PCR. In this study, we proposed a new method that combines dPCR with melting curve analysis and applied that method to KRAS genotyping. Since the melting temperature (Tm) of the PCR product hardly depends on the amplification efficiency, genotyping accuracy is improved by using the Tm value. The results showed that the peaks of the distribution of the Tm values of DNA in the wells were 68.7, 66.3, and 62.6 °C for wild-type KRAS, the G12R mutant, and the G12D mutant, respectively, and the standard deviation of the Tm values was 0.2 °C for each genotype. This result indicates that the proposed method is capable of discriminating between the wild-type sequence and the two mutants. To the best of our knowledge, this is the first demonstration of the genotyping of single mutations by combining melting curve analysis and dPCR. The application of this approach could be useful for the quantification and genotyping of cancer-related genes in low-abundance samples.
- 24 July 2018
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 34 (32) , 9366-9375
Selection of Diacrylate Monomers for Sub-15 nm Ultraviolet Nanoimprinting by Resonance Shear Measurement
In UV nanoimprinting, selection of monomers suitable for sub-15 nm patterning is difficult because the behavior of resin filling at this scale still remains scientifically unclear. We demonstrate sub-15 nm patterning by UV nanoimprinting using silica molds with 20-, 15-, and 7-nm-diameter holes; however, the 7-nm-diameter pillar patterns were not fabricated using hydroxy-containing monomers. The filling behavior into silica holes of around 10 nm depended on the chemical structure of monomers. Resonance shear measurements revealed the followings: (1) The viscosities of hydroxy-containing monomers confined between chlorodimethyl(3,3,3-trifluoropropyl)silane (FAS3-Cl)-modified surfaces began to increase at shorter distances than those of the monomers between unmodified surfaces. (2) The monomers confined between tridecafluoro-1,1,2,2-tetrahydrooctyltrimethoxysilane (FAS13)-modified surfaces were squeezed out when surface-surface distance decreased at less than 7 nm. Measured viscosities between the FAS3-Cl-modified silica surfaces were correlated with the insufficient filling behavior into silica holes of around 10 nm in UV nanoimprinting. Contact angle measurements provided additional insight that a higher wettability of the monomers onto the antisticking chemisorbed monolayers resulted in imprinted patterns with higher aspect ratios. Considering the increase in the monomer viscosity in the nanospace and the wettability of monomers onto chemisorbed monolayers, we concluded that the monomer showing low viscosity under confinement and high wettability onto the mold surface was suitable for single-digit-nanometer UV nanoimprinting.
- 24 July 2018
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 34 (32) , 9366-9375
Selection of Diacrylate Monomers for Sub-15 nm Ultraviolet Nanoimprinting by Resonance Shear Measurement
In UV nanoimprinting, selection of monomers suitable for sub-15 nm patterning is difficult because the behavior of resin filling at this scale still remains scientifically unclear. We demonstrate sub-15 nm patterning by UV nanoimprinting using silica molds with 20-, 15-, and 7-nm-diameter holes; however, the 7-nm-diameter pillar patterns were not fabricated using hydroxy-containing monomers. The filling behavior into silica holes of around 10 nm depended on the chemical structure of monomers. Resonance shear measurements revealed the followings: (1) The viscosities of hydroxy-containing monomers confined between chlorodimethyl(3,3,3-trifluoropropyl)silane (FAS3-Cl)-modified surfaces began to increase at shorter distances than those of the monomers between unmodified surfaces. (2) The monomers confined between tridecafluoro-1,1,2,2-tetrahydrooctyltrimethoxysilane (FAS13)-modified surfaces were squeezed out when surface-surface distance decreased at less than 7 nm. Measured viscosities between the FAS3-Cl-modified silica surfaces were correlated with the insufficient filling behavior into silica holes of around 10 nm in UV nanoimprinting. Contact angle measurements provided additional insight that a higher wettability of the monomers onto the antisticking chemisorbed monolayers resulted in imprinted patterns with higher aspect ratios. Considering the increase in the monomer viscosity in the nanospace and the wettability of monomers onto chemisorbed monolayers, we concluded that the monomer showing low viscosity under confinement and high wettability onto the mold surface was suitable for single-digit-nanometer UV nanoimprinting.
- 7 June 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (12) , 6305-6308
Parallel Evaluation of Melting Temperatures of DNAs in the Arrayed Droplets through the Fluorescence from DNA Intercalators
Parallel evaluation of melting temperatures (Tm’s) of DNA molecules in multiple floating droplets (20 μm in diameter) was demonstrated. The Tm values were evaluated from the melting curves which were observed through the fluorescence from the DNA intercalators. The Tm values measured in the droplets corresponded well to those measured in the bulk, indicating the validity of the measurement. The parallel evaluation of Tm’s was realized by observing melting curves of DNAs in the different droplets at the same time using the “droplet guide”, which guided and fixed the floating droplets to the designated points in the observing plane. This demonstration would pave the way for the improvement of the precision of droplet digital PCR (ddPCR), whose state-of-the-art ascribes color and intensity of fluorescence to the base sequence of DNA in the droplet.
- 7 June 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (12) , 6305-6308
Parallel Evaluation of Melting Temperatures of DNAs in the Arrayed Droplets through the Fluorescence from DNA Intercalators
Parallel evaluation of melting temperatures (Tm’s) of DNA molecules in multiple floating droplets (20 μm in diameter) was demonstrated. The Tm values were evaluated from the melting curves which were observed through the fluorescence from the DNA intercalators. The Tm values measured in the droplets corresponded well to those measured in the bulk, indicating the validity of the measurement. The parallel evaluation of Tm’s was realized by observing melting curves of DNAs in the different droplets at the same time using the “droplet guide”, which guided and fixed the floating droplets to the designated points in the observing plane. This demonstration would pave the way for the improvement of the precision of droplet digital PCR (ddPCR), whose state-of-the-art ascribes color and intensity of fluorescence to the base sequence of DNA in the droplet.
- 15 August 2013
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 5 (16) , 7661-7664
Reduction in Viscosity of Quasi-2D-Confined Nanoimprint Resin through the Addition of Fluorine-Containing Monomers: Shear Resonance Study
The fluidity of the resin for the nanoimprint lithography was investigated in a quasi-2D space by the shear resonance measurement, which enables us to measure the viscous property of the resin confined in a nanometer gap between mica surfaces. With this technique, we could observe that the resin fluidity was enhanced by the addition of the fluorine-containing monomer. The fluidity of the resin with the fluorine-containing monomer was maintained until the distance between mica surfaces became smaller than 15 nm, wheras the resin without the fluorine-containing monomer started losing its fluidity when the distance became 30 nm. Two reasons possibly explain the result; (i) the interaction between the resin and mica was reduced by the existence of the fluorine-containing segregated layer at the interface, and (ii) the reduction in viscosity took place by the addition of the fluorine-containing monomer that reduced the degree of chain entanglement in the resin because of its small intermolecular interaction force. The effect of the length of the perfluoroalkyl chain in the fluorine-containing monomer is also discussed.
- 15 August 2013
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 5 (16) , 7661-7664
Reduction in Viscosity of Quasi-2D-Confined Nanoimprint Resin through the Addition of Fluorine-Containing Monomers: Shear Resonance Study
The fluidity of the resin for the nanoimprint lithography was investigated in a quasi-2D space by the shear resonance measurement, which enables us to measure the viscous property of the resin confined in a nanometer gap between mica surfaces. With this technique, we could observe that the resin fluidity was enhanced by the addition of the fluorine-containing monomer. The fluidity of the resin with the fluorine-containing monomer was maintained until the distance between mica surfaces became smaller than 15 nm, wheras the resin without the fluorine-containing monomer started losing its fluidity when the distance became 30 nm. Two reasons possibly explain the result; (i) the interaction between the resin and mica was reduced by the existence of the fluorine-containing segregated layer at the interface, and (ii) the reduction in viscosity took place by the addition of the fluorine-containing monomer that reduced the degree of chain entanglement in the resin because of its small intermolecular interaction force. The effect of the length of the perfluoroalkyl chain in the fluorine-containing monomer is also discussed.
- 1 November 2010
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 351 (2) , 580-583
A durable PtRu/C catalyst with a thin protective layer for direct methanol fuel cells
- 1 November 2010
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 351 (2) , 580-583
A durable PtRu/C catalyst with a thin protective layer for direct methanol fuel cells
- 8 December 2008
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 1 (2) , 225-227
Highly Thermoconductive Polymer Nanocomposite with a Nanoporous α-Alumina Sheet
A highly thermoconductive insulative polymer nanocomposite with a nanoporous alpha-alumina sheet was reported. The thermal conductivity of the nanocomposite along the surface normal was 12 W m(-1) K(-1) (41 vol % alumina), a value as high as that predicted theoretically for a nanocomposite with thermoconductive fillers that form a perfectly connected thermoconductive network. The high thermal conductivity is probably due to the continuous alpha-alumina phase that functions as an efficient phonon path in the nanocomposite. The results suggest that the structure of the filler is important for the design of highly thermoconductive materials.
- 8 December 2008
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 1 (2) , 225-227
Highly Thermoconductive Polymer Nanocomposite with a Nanoporous α-Alumina Sheet
A highly thermoconductive insulative polymer nanocomposite with a nanoporous alpha-alumina sheet was reported. The thermal conductivity of the nanocomposite along the surface normal was 12 W m(-1) K(-1) (41 vol % alumina), a value as high as that predicted theoretically for a nanocomposite with thermoconductive fillers that form a perfectly connected thermoconductive network. The high thermal conductivity is probably due to the continuous alpha-alumina phase that functions as an efficient phonon path in the nanocomposite. The results suggest that the structure of the filler is important for the design of highly thermoconductive materials.