QWQi Wang

Qi Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qi Wang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bayesian Inversion for Surface Magnetic Resonance Tomography Based on Geostatistics

    by Chuandong Jiang, Yunzhi Wang, Ruixin Miao, Qi Wang, Xinlei Shang, Baofeng Tian, Qingming Duan, Tingting Lin

    Magnetic resonance tomography (MRT) has the advantages of direct, quantitative and unique interpretation in the field of groundwater detection. Currently, the inversion of MRT data primarily uses the QT (Q-time) inversion method based on Tikhonov regularization. However, when the heterogeneity of an aquifer is high, and the water content distribution is markedly uneven, this method removes many details in the model and cannot perform uncertainty analysis on the results. To solve these problems, we propose a Bayesian inversion for MRT data based on geostatistics. The method uses previously known geological data, such as drilling, to determine prior information model containing variograms and mixture Gaussian probability distributions for generating many stochastic realizations. Under the Bayesian framework, a modified Markov chain Monte Carlo strategy (MCMC) is used to obtain the posterior probability distributions of subsurface aquifers and hydraulic conductivity, and the results of quantitative uncertainty analysis. By comparing the inversion performance for simulated models, the imaging result of the Bayesian method is found to be markedly more accurate than that of the QT method for subsurface two-dimensional aquifers, particularly in explaining the stochastic model (i.e., the water-bearing model with an uneven distribution of water content). This method can also intuitively quantify the uncertainty of the imaging results, which mitigates the shortcomings of existing inversion methods. This paper also discusses the effects of prior information, number of chains and noise levels on the results, and also validates the effectiveness and practicability of the proposed method using field-measured data.


  • Tunnel Magnetic Resonance Tomography for 2-D Water-Bearing Structures Using Rotating Coil With Separated Loop Configuration

    by Qi Wang, Chuandong Jiang, Kai Luo

    In tunnel construction, to prevent the occurrence of water inrush, the geological conditions of faults and underground rivers must be determined in advance. As a direct detection method of groundwater, magnetic resonance sounding (MRS) has been applied for the advanced detection of water-related hazards in tunnels and mines recently. However, the results of conventional 1-D MRS cannot correctly reflect the spatial distribution characteristics of complicated water-bearing structures. In this article, we propose a measurement scheme using a rotating coil with separated transmitter and receiver loop configuration (SEP) for the 2-D imaging of water-bearing structures, such as faults and conduits. In this scheme, the receiver coil rotates several times, while the transmitter coil, which is separated from the receiver coil by a certain distance, remains stationary. Moreover, all the observed data participate in the inversion to achieve the 2-D magnetic resonance tomography (MRT). Numerical simulations of water-bearing faults are performed, and we compare and analyze the 2-D sensitivity and inversion results of two measurement schemes for a rotating coil, i.e., an overlapping transmitter and receiver loop configuration (OVE) and SEP. The results showed that the imaging results of the SEP are better than those of the OVE because the OVE imaging has a symmetric artifact. Finally, we discuss the influence of the transceiver distance, the resistivity, and the environmental noise on the imaging results. Moreover, the imaging results of the water-bearing conduit at different locations were obtained to validate the effectiveness of the SEP rotating coil measurement scheme.


  • Data Correction for Surface Nuclear Magnetic Resonance in an Inhomogeneous Geomagnetic Field

    by Qi Wang, Shu Diao, Chuandong Jiang

    In surface nuclear magnetic resonance, we use the geomagnetic field as the background field and excite hydrogen protons in groundwater by emitting an alternating current with a frequency equal to the Larmor frequency. However, in practical, inhomogeneous geomagnetic field (IGF) or magnetic anomaly caused by ferromagnetic materials will make the non-uniqueness of Larmor frequency, resulting in the simultaneous existence of on-resonance and off-resonance (we refer as composite resonance). If only the on-resonance or off-resonance model is used to interpret the composite resonance data, then the accuracy of the inversion results would be seriously affected. To solve the problem, we derived the expression of free induction decay (FID) signal of composite magnetic resonance based on the layered model. The influence of IGF on the characteristic parameters of the FID signal was analyzed through simulation models, which showed that with the increase of the frequency offset and gradient, the relaxation time decreased prominently. Furthermore, we proposed an iterative correction method based on a frequency-depth curve. Through the synthetic and measured data, this study proved that the water content and relaxation time are consistent with the truth after correction, and the data consistency is better than that before correction.


  • Two-dimensional QT inversion of complex magnetic resonance tomography data

    by Chuandong Jiang, Mike Müller-Petke, Qi Wang, Jan Igel

    Surface nuclear magnetic resonance is a valuable technique that provides insight into the distribution of water content and relaxation time, thus revealing hydraulic properties in the subsurface. Recent research has introduced a new measurement layout that allows for time-efficient imaging of the 2D parameter distribution. Furthermore, for 1D investigations, it has been verified that complex data can provide improved resolution and depth penetration. In our research, we have developed an inverse modeling algorithm based on the QT-inversion scheme that uses the 2D complex magnetic resonance tomography data. We evaluate the uses and limitations of complex data for 2D investigations. By comparing resolution measures, we test this algorithm against state-of-the-art amplitude-based inverse modeling using resolution measures, a rigorous synthetic test, and a field example. Finally, we assess the impact of unknown conductivity and off-resonance excitation on the subsurface image and examined their limitations in field applications. We find that complex inversion is feasible in practice and provides superior results but demands precise knowledge of the true excitation frequency.


  • An alternative approach to handling co-frequency harmonics in surface nuclear magnetic resonance data

    by Qi Wang, Chuandong Jiang, Mike Müller-Petke

    Surface nuclear magnetic resonance (SNMR) data typically suffers from very low signal-to-noise ratio. Two of the main sources of noise that generate low signal-to-noise ratios are powerlines and railways that create harmonic noise. Some noise cancellation strategies for mitigating this harmonic noise have been presented. However, when the frequency of one source of harmonics is close to the SNMR (Larmor) frequency value and thus when co-frequency harmonics are present, either the SNMR signal is significantly affected or harmonic noise cannot be effectively cancelled. Recently, a new approach to handling the issue of co-frequency harmonics that utilizes additional reference loops has been presented. In this paper, we propose an alternative approach to the elimination of co-frequency harmonics that involves using a processing-based, data-driven fitting method to avoid using additional reference loops. We investigate the accuracy and stability of the proposed fitting-based method and compare our results to those of other processing approaches using synthetic data. We find that the fitting-based approach to preserving the SNMR signal is superior to all other processing-based algorithms while effectively cancelling co-frequency harmonics. We apply the proposed fitting method to field data and demonstrate that even two different noise sources that both generate co-frequency harmonics can be handled. Finally, an efficient approach to determine the fundamental frequency of harmonics that allows acceleration of the processing of large volumes of data is given.


  • An Efficient Algorithm for Probabilistic RkNN Query on Uncertain Data with Large k

    by Shengsheng Wang, Chuangfeng Wang, Wei Liu, Qi Wang

    Recently, the query on uncertain data attracts much attention and it is great significance for probabilistic reverse k neighbor query on uncertain data based on location-based services (LBS). However, the relevant research is less and immature. Probabilistic reverse k nearest neighbor (PRkNN) requests the query point of reverse k neighbor query and the probability is greater than the given threshold. The main problem of the existing research is that, when the value k is larger, a reduction of the query efficiency is obvious. In this paper, we propose an algorithm called PRCLU for PRkNN with larger k, including pruning phase and verification phase. The pruning phase with a minimum circle to enclose the uncertain data, which performs pruning with the region, then followed by probabilistic pruning strategy in sequence. The results of the experiment show that the algorithm PRCLU is better than other similar methods when k is larger.


  • Joint conductivity-depth imaging for fixed-wing electromagnetic data Bx and Bz

    by Kaiguang Zhu, Bingbing Li, Qi Wang, Yuqi Cheng

    Summary: In the fixed-wing electromagnetic survey, the total field data is commonly used for conductivity-depth imaging, because it is difficult to obtain the correct multi-component response in the inertial coordinate system due to the limitation of bird attitude measurement. It loses multi-component measurement information, and decreases the imaging precision. Currently, bird attitude can be recorded by the inertial navigation unit (INU) or GPS antennas during surveys, and then we can calculate multi-component electromagnetic responses in the inertial coordinate system from the measured multi-component responses in the bird system through the attitude correction algorithm. In this paper, we have developed a joint conductivity-depth imaging approach based on two-component B field. A lookup table of Bx-Bz-conductivity-altitude is established based on the fixed-wing electromagnetic forward algorithm. Apparent conductivity can be obtained by searching the lookup table of Bx-Bz which is established above. And then the depth is obtained by transformation of the skin depth. Consequently, we get the result of the joint conductivity-depth imaging. In order to prove the effectiveness of the algorithm, we apply the two-component table lookup algorithm to synthetic data for layered and pseudo-2D models compared with the total field table lookup algorithm. All of the results indicate that joint conductivity-depth imaging based on Bx and Bz can achieve a better agreement with the true model.