Arthur T. Zielinski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arthur T. Zielinski has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Markus Kalberer
Centre for Atmospheric Science, Department of Chemistry , University of Cambridge , Cambridge CB2 1EW , United Kingdom
7 shared publications- Roderic L. Jones
Yusuf Hamied Department of Chemistry, University of Cambridge, Cambridge, UK
6 shared publications - Ashwin A. Seshia
University of Cambridge
4 shared publications - Abhinav Prasad
School of Physics and Astronomy, University of Glasgow, Glasgow, UK
3 shared publications - Chiara Giorio
University of Cambridge (Cambridge, United Kingdom)
3 shared publications - Andrea Tapparo
Department of Chemical Sciences, University of Padua, Via Francesco Marzolo, 1, 35122 Padua, Italy
2 shared publications
Latest Publications
- 3 July 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (16) , 9716-9724
Measuring Aerosol Phase Changes and Hygroscopicity with a Microresonator Mass Sensor
The interaction between atmospheric aerosol particles and water vapor influences aerosol size, phase and composition, parameters which critically influence their impacts in the atmosphere. Methods to accurately measure aerosol water uptake for a wide range of particle types are therefore merited. We present here a new method for characterizing aerosol hygroscopicity, an impaction stage containing a MicroElectroMechanical Systems (MEMS) microresonator. We find that deliquescence and efflorescence relative humidities (RHs) of sodium chloride and ammonium sulfate are easily diagnosed via changes in resonant frequency and peak sharpness. These agree well with literature values and thermodynamic models. Furthermore, we demonstrate that unlike other resonator-based techniques, full hygroscopic growth curves can be derived, including for an inorganic-organic mixture (sodium chloride and malonic acid) which remains liquid at all RH. The response of the microresonator frequency to temperature and particle mechanical properties, and the resulting limitations when measuring hygroscopicity, are discussed. MEMS resonators show great potential as miniaturized ambient aerosol mass monitors and future work will consider the applicability of our approach to complex ambient samples. The technique also offers an alternative to established methods for accurate thermodynamic measurements in the laboratory.
- 3 July 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (16) , 9716-9724
Measuring Aerosol Phase Changes and Hygroscopicity with a Microresonator Mass Sensor
The interaction between atmospheric aerosol particles and water vapor influences aerosol size, phase and composition, parameters which critically influence their impacts in the atmosphere. Methods to accurately measure aerosol water uptake for a wide range of particle types are therefore merited. We present here a new method for characterizing aerosol hygroscopicity, an impaction stage containing a MicroElectroMechanical Systems (MEMS) microresonator. We find that deliquescence and efflorescence relative humidities (RHs) of sodium chloride and ammonium sulfate are easily diagnosed via changes in resonant frequency and peak sharpness. These agree well with literature values and thermodynamic models. Furthermore, we demonstrate that unlike other resonator-based techniques, full hygroscopic growth curves can be derived, including for an inorganic-organic mixture (sodium chloride and malonic acid) which remains liquid at all RH. The response of the microresonator frequency to temperature and particle mechanical properties, and the resulting limitations when measuring hygroscopicity, are discussed. MEMS resonators show great potential as miniaturized ambient aerosol mass monitors and future work will consider the applicability of our approach to complex ambient samples. The technique also offers an alternative to established methods for accurate thermodynamic measurements in the laboratory.
- Open Access
- 25 June 2018
- Published by Springer Nature in Aerosol Science and Engineering
- Vol. 2 (3) , 118-129
Compositional Analysis of Adsorbed Organic Aerosol on a Microresonator Mass Sensor
- 25 June 2018
- Published by Springer Nature in Aerosol Science and Engineering
- Vol. 2 (3) , 118-129
Open AccessCompositional Analysis of Adsorbed Organic Aerosol on a Microresonator Mass Sensor
- 1 April 2018
- Published by Elsevier in Atmospheric Environment
- Vol. 178, 129-139
A new processing scheme for ultra-high resolution direct infusion mass spectrometry data
- 1 April 2018
- Published by Elsevier in Atmospheric Environment
- Vol. 178, 129-139
A new processing scheme for ultra-high resolution direct infusion mass spectrometry data
- Open Access
- 13 September 2017
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry A
- Vol. 121 (40) , 7641-7654
Cloud Processing of Secondary Organic Aerosol from Isoprene and Methacrolein Photooxidation
Aerosol-cloud interaction contributes to the largest uncertainties in the estimation and interpretation of the Earth’s changing energy budget. The present study explores experimentally the impacts of water condensation-evaporation events, mimicking processes occurring in atmospheric clouds, on the molecular composition of secondary organic aerosol (SOA) from the photooxidation of methacrolein. A range of on- and off-line mass spectrometry techniques were used to obtain a detailed chemical characterization of SOA formed in control experiments in dry conditions, in triphasic experiments simulating gas-particle-cloud droplet interactions (starting from dry conditions and from 60% relative humidity (RH)), and in bulk aqueous-phase experiments. We observed that cloud events trigger fast SOA formation accompanied by evaporative losses. These evaporative losses decreased SOA concentration in the simulation chamber by 25–32% upon RH increase, while aqueous SOA was found to be metastable and slowly evaporated after cloud dissipation. In the simulation chamber, SOA composition measured with a high-resolution time-of-flight aerosol mass spectrometer, did not change during cloud events compared with high RH conditions (RH > 80%). In all experiments, off-line mass spectrometry techniques emphasize the critical role of 2-methylglyceric acid as a major product of isoprene chemistry, as an important contributor to the total SOA mass (15–20%) and as a key building block of oligomers found in the particulate phase. Interestingly, the comparison between the series of oligomers obtained from experiments performed under different conditions show a markedly different reactivity. In particular, long reaction times at high RH seem to create the conditions for aqueous-phase processing to occur in a more efficient manner than during two relatively short cloud events.
- 13 September 2017
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry A
- Vol. 121 (40) , 7641-7654
Open AccessCloud Processing of Secondary Organic Aerosol from Isoprene and Methacrolein Photooxidation
Aerosol-cloud interaction contributes to the largest uncertainties in the estimation and interpretation of the Earth’s changing energy budget. The present study explores experimentally the impacts of water condensation-evaporation events, mimicking processes occurring in atmospheric clouds, on the molecular composition of secondary organic aerosol (SOA) from the photooxidation of methacrolein. A range of on- and off-line mass spectrometry techniques were used to obtain a detailed chemical characterization of SOA formed in control experiments in dry conditions, in triphasic experiments simulating gas-particle-cloud droplet interactions (starting from dry conditions and from 60% relative humidity (RH)), and in bulk aqueous-phase experiments. We observed that cloud events trigger fast SOA formation accompanied by evaporative losses. These evaporative losses decreased SOA concentration in the simulation chamber by 25–32% upon RH increase, while aqueous SOA was found to be metastable and slowly evaporated after cloud dissipation. In the simulation chamber, SOA composition measured with a high-resolution time-of-flight aerosol mass spectrometer, did not change during cloud events compared with high RH conditions (RH > 80%). In all experiments, off-line mass spectrometry techniques emphasize the critical role of 2-methylglyceric acid as a major product of isoprene chemistry, as an important contributor to the total SOA mass (15–20%) and as a key building block of oligomers found in the particulate phase. Interestingly, the comparison between the series of oligomers obtained from experiments performed under different conditions show a markedly different reactivity. In particular, long reaction times at high RH seem to create the conditions for aqueous-phase processing to occur in a more efficient manner than during two relatively short cloud events.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Particulate mass sensing with piezoelectric bulk acoustic mode resonators
Current portable particle detection instruments typically rely on optical methods which are limited to 100 nm diameter particles. Microfabricated bulk acoustic resonators, when used as mass balances, could take particle detection below this limit. This study examines the collection of particles onto piezoelectric bulk acoustic mode resonators from gaseous flow using classical impaction. Collection of both polystyrene latex particles and α-pinene secondary organic aerosol particles was examined in terms of frequency shift and collection efficiency. A new experimental setup was introduced which allows for adjusting major impactor, resonator, and aerosol properties. Preliminary results show the setup works for both particles while the saturation limit was not reached within an hour despite highly elevated particle concentrations.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Particulate mass sensing with piezoelectric bulk acoustic mode resonators
Current portable particle detection instruments typically rely on optical methods which are limited to 100 nm diameter particles. Microfabricated bulk acoustic resonators, when used as mass balances, could take particle detection below this limit. This study examines the collection of particles onto piezoelectric bulk acoustic mode resonators from gaseous flow using classical impaction. Collection of both polystyrene latex particles and α-pinene secondary organic aerosol particles was examined in terms of frequency shift and collection efficiency. A new experimental setup was introduced which allows for adjusting major impactor, resonator, and aerosol properties. Preliminary results show the setup works for both particles while the saturation limit was not reached within an hour despite highly elevated particle concentrations.
- Open Access
- 1 December 2015
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 236, 369-379
Effects of spatial sensitivity on mass sensing with bulk acoustic mode resonators
- 1 December 2015
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 236, 369-379
Open AccessEffects of spatial sensitivity on mass sensing with bulk acoustic mode resonators
- 19 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 28-31
Studying particulate adsorption by drying droplets on a microfabricated electro-acoustic resonator
Microfabricated in-plane bulk acoustic resonators can be configured as gravimetric sensors wherein the mass of surface-bound species is transduced as a shift in the resonant frequency. Using this principle, we examine the adsorption of spherical polystyrene latex particles on the resonator surface by drying particulate laden droplets. Distribution of particles on the surface is governed by the coffee-ring effect which is correlated to the observed frequency response of the resonators. We also present an analytical approach to describe the spatial dependence of adsorbed mass on the induced frequency shift for square plate resonators which can be extended to model other resonator geometries.
- 19 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 28-31
Studying particulate adsorption by drying droplets on a microfabricated electro-acoustic resonator
Microfabricated in-plane bulk acoustic resonators can be configured as gravimetric sensors wherein the mass of surface-bound species is transduced as a shift in the resonant frequency. Using this principle, we examine the adsorption of spherical polystyrene latex particles on the resonator surface by drying particulate laden droplets. Distribution of particles on the surface is governed by the coffee-ring effect which is correlated to the observed frequency response of the resonators. We also present an analytical approach to describe the spatial dependence of adsorbed mass on the induced frequency shift for square plate resonators which can be extended to model other resonator geometries.
- 9 June 2013
- Published by ASME International
Employing Visual Image Correlation for the Measurement of Compressive Strains for Arctic Onshore Pipelines
The Arctic onshore environment contains regions of discontinuous permafrost, where pipes may be subject to displacement-controlled bending in addition to high hoop stresses due to the pressurized fluids being transported. Considering the displacement-controlled nature of the deformations, strain-based design methodologies have been developed for permafrost pipelines when they are subject to bending and tension, which limit the longitudinal compressive and tensile strains. The widely accepted methodology in the industry to obtain the compressive strain capacity of line pipes subject to bending is to conduct Finite Element Analysis, incorporating material and geometrical nonlinearity calibrated against benchmark full-scale tests (bend tests) [1,2]. During these tests, compressive strains can be measured by various methods. The seemingly obvious choice is to apply strain gauges along the compression face of the specimen with respect to bending (intrados). This method will provide reasonable results until the compressive strain pattern begins to vary due to the initiation of buckle formation, which typically occurs shortly after yield. In order to measure average compressive strain beyond yield and up to buckling, the method used by C-FER Technologies (C-FER) involves using rotation measurement devices (inclinometers) to calculate the strain change between the most compressive and tensile fibres of the specimen (intrados and extrados, respectively) with respect to the bending direction. This value is then subtracted from the tensile strain gauge readings as measured by the strain gauge(s) located on the extrados of the specimen. The average compressive strain values derived from the inclinometer and extrados strain gauge measurements are based on the assumption that the plane sections remain plane. Recently, five large diameter pipes were bend-tested at C-FER’s testing facility in Edmonton, Alberta. In addition to the compressive strain measurement method used by C-FER described above (C-FER method), a visual image correlation (VIC) camera system was used to survey the strain distribution on the compressive face of the specimens. This paper gives a brief description of the test setup and instrumentation of this test program. The VIC camera setup and measurement technique are described and the overall strain distribution on the bending intrados as measured by the VIC cameras is presented. Strain measured by the VIC system is compared with gauge measurements at local points as well as the average compressive strain behaviour of the specimens obtained through the C-FER method described above. The results show that the VIC system can be a candidate to replace the conventional measurement techniques employed for compressive strain limit testing in support of strain-based design of arctic pipelines.
- 9 June 2013
- Published by ASME International
Employing Visual Image Correlation for the Measurement of Compressive Strains for Arctic Onshore Pipelines
The Arctic onshore environment contains regions of discontinuous permafrost, where pipes may be subject to displacement-controlled bending in addition to high hoop stresses due to the pressurized fluids being transported. Considering the displacement-controlled nature of the deformations, strain-based design methodologies have been developed for permafrost pipelines when they are subject to bending and tension, which limit the longitudinal compressive and tensile strains. The widely accepted methodology in the industry to obtain the compressive strain capacity of line pipes subject to bending is to conduct Finite Element Analysis, incorporating material and geometrical nonlinearity calibrated against benchmark full-scale tests (bend tests) [1,2]. During these tests, compressive strains can be measured by various methods. The seemingly obvious choice is to apply strain gauges along the compression face of the specimen with respect to bending (intrados). This method will provide reasonable results until the compressive strain pattern begins to vary due to the initiation of buckle formation, which typically occurs shortly after yield. In order to measure average compressive strain beyond yield and up to buckling, the method used by C-FER Technologies (C-FER) involves using rotation measurement devices (inclinometers) to calculate the strain change between the most compressive and tensile fibres of the specimen (intrados and extrados, respectively) with respect to the bending direction. This value is then subtracted from the tensile strain gauge readings as measured by the strain gauge(s) located on the extrados of the specimen. The average compressive strain values derived from the inclinometer and extrados strain gauge measurements are based on the assumption that the plane sections remain plane. Recently, five large diameter pipes were bend-tested at C-FER’s testing facility in Edmonton, Alberta. In addition to the compressive strain measurement method used by C-FER described above (C-FER method), a visual image correlation (VIC) camera system was used to survey the strain distribution on the compressive face of the specimens. This paper gives a brief description of the test setup and instrumentation of this test program. The VIC camera setup and measurement technique are described and the overall strain distribution on the bending intrados as measured by the VIC cameras is presented. Strain measured by the VIC system is compared with gauge measurements at local points as well as the average compressive strain behaviour of the specimens obtained through the C-FER method described above. The results show that the VIC system can be a candidate to replace the conventional measurement techniques employed for compressive strain limit testing in support of strain-based design of arctic pipelines.