Shuangshuang Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shuangshuang Tian has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoxing Zhang
Hubei University of Technology
22 shared publications - Yi Li
Wuhan University
12 shared publications - Song Xiao
State Key Laboratory of Power Grid Environmental Protection School of Electrical Engineering and Automation Wuhan University Hubei China
10 shared publications - Fanchao Ye
Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan, China
5 shared publications Ju Tang
School of Electrical Engineering, Wuhan University 1 , Wuhan 430072, China
4 shared publications- Yann Cressault
Laboratoire Plasma et Conversion dEnergie (LAPLACE), Universit de Toulouse, Toulouse, France
4 shared publications
Latest Publications
- 9 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Electro–Thermal Coupled Decomposition Mechanism of a High-Safety Fluorinated Silicone Oil–Paper Insulation System Based on ReaxFF.
The methyl fluorinated silicone oil exhibits a combination of advantages, including a high flash point and fire point, excellent insulating performance, and chemical stability, making it a promising insulating oil for enhancing transformer safety. To evaluate its applicability in oil–paper insulation systems, ReaxFF-based molecular dynamics simulations are employed to construct composite systems of methyl fluorinated silicone oil with aromatic polyamide paper (Nomex) and with cellulose insulation paper, respectively. The electro–thermal coupled decomposition behaviors of the two systems are comparatively investigated. The results indicate that, under electro–thermal coupling conditions, the Nomex–methyl system demonstrates higher interfacial stability, a lower decomposition rate of long-chain reactant molecules, and a significantly reduced generation of the primary degradation product H₂O compared with the cellulose–methyl system, resulting in an overall lower degree of decomposition. In summary, the oil–paper insulation system composed of methyl fluorinated silicone oil and Nomex insulation paper exhibits superior compatibility and aging resistance and is therefore more suitable as the main oil–paper insulation combination for fluorinated silicone oil–filled transformers.
- 9 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Electro–Thermal Coupled Decomposition Mechanism of a High-Safety Fluorinated Silicone Oil–Paper Insulation System Based on ReaxFF.
The methyl fluorinated silicone oil exhibits a combination of advantages, including a high flash point and fire point, excellent insulating performance, and chemical stability, making it a promising insulating oil for enhancing transformer safety. To evaluate its applicability in oil–paper insulation systems, ReaxFF-based molecular dynamics simulations are employed to construct composite systems of methyl fluorinated silicone oil with aromatic polyamide paper (Nomex) and with cellulose insulation paper, respectively. The electro–thermal coupled decomposition behaviors of the two systems are comparatively investigated. The results indicate that, under electro–thermal coupling conditions, the Nomex–methyl system demonstrates higher interfacial stability, a lower decomposition rate of long-chain reactant molecules, and a significantly reduced generation of the primary degradation product H₂O compared with the cellulose–methyl system, resulting in an overall lower degree of decomposition. In summary, the oil–paper insulation system composed of methyl fluorinated silicone oil and Nomex insulation paper exhibits superior compatibility and aging resistance and is therefore more suitable as the main oil–paper insulation combination for fluorinated silicone oil–filled transformers.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- p. 1
Influence of O 2 Content on the Short-Circuit Grounding Making Performance and Decomposition Characteristics of C 4 F 7 N/CO 2 /O 2 Gas Mixtures in Ring Main Units
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- p. 1
Influence of O 2 Content on the Short-Circuit Grounding Making Performance and Decomposition Characteristics of C 4 F 7 N/CO 2 /O 2 Gas Mixtures in Ring Main Units
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Bubble Motion and Insulation Characteristics of Evaporative Cooling Medium C 6 F 12 O
Perfluorohexanone (C6F12O) has emerged as an ideal medium for electrical equipment evaporative cooling systems due to its excellent comprehensive properties, including low boiling point and superior insulation performance. The heat dissipation capacity and insulation characteristics of the system can be significantly affected by the bubble dynamics of the medium during the evaporative cooling process, thereby limiting its application in high-voltage, high-capacity power equipment. Therefore, the investigation of the bubble behavior and insulation properties of C6F12O is considered crucial for practical applications in power equipment. In this study, comprehensive investigations are conducted to examine the effects of temperature, electric field, heat flux density, and electrode spacing on bubble dynamics and insulation characteristics using C6F12O. The experimental results reveal that bubbles exhibit five distinct behavioral modes in the absence of the electric field: migration, deformation, fusion, splitting, and fragmentation. The system is identified to operate in natural convection regime at 305-315 K and nucleate boiling regime at 322-348 K. Under uniform electric fields, the breakdown characteristics of two-phase flow are found to resemble those of liquid phase due to the "liquid lock" phenomenon. When the heat flux density ranges from 0 to 3.31 W/cm², the two-phase system preserves its liquid-phase properties and adheres to a two-parameter Weibull distribution due to the liquid lock effect. As the heat flux density increases to 4.41-5.51 W/cm², bubbles eventually penetrate the liquid lock barrier, establishing gas-phase conduction pathways. These findings provide valuable theoretical guidance and practical references for the engineering application of evaporative cooling in electrical power equipment.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Bubble Motion and Insulation Characteristics of Evaporative Cooling Medium C 6 F 12 O
Perfluorohexanone (C6F12O) has emerged as an ideal medium for electrical equipment evaporative cooling systems due to its excellent comprehensive properties, including low boiling point and superior insulation performance. The heat dissipation capacity and insulation characteristics of the system can be significantly affected by the bubble dynamics of the medium during the evaporative cooling process, thereby limiting its application in high-voltage, high-capacity power equipment. Therefore, the investigation of the bubble behavior and insulation properties of C6F12O is considered crucial for practical applications in power equipment. In this study, comprehensive investigations are conducted to examine the effects of temperature, electric field, heat flux density, and electrode spacing on bubble dynamics and insulation characteristics using C6F12O. The experimental results reveal that bubbles exhibit five distinct behavioral modes in the absence of the electric field: migration, deformation, fusion, splitting, and fragmentation. The system is identified to operate in natural convection regime at 305-315 K and nucleate boiling regime at 322-348 K. Under uniform electric fields, the breakdown characteristics of two-phase flow are found to resemble those of liquid phase due to the "liquid lock" phenomenon. When the heat flux density ranges from 0 to 3.31 W/cm², the two-phase system preserves its liquid-phase properties and adheres to a two-parameter Weibull distribution due to the liquid lock effect. As the heat flux density increases to 4.41-5.51 W/cm², bubbles eventually penetrate the liquid lock barrier, establishing gas-phase conduction pathways. These findings provide valuable theoretical guidance and practical references for the engineering application of evaporative cooling in electrical power equipment.
- Open Access
- 30 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (17) , 9576
Life Cycle Carbon Footprint Assessment of 12 kV C4F7N Gas-Insulated Switchgear Systems
The C4F7N eco-friendly switchgear shows significant application potential, and quantifying its carbon footprint can accelerate the low-carbon transition in the power industry. A life cycle assessment (LCA) model for a 12 kV C4F7N eco-friendly switchgear is established in this study, and the carbon footprint across four stages—raw material acquisition, transportation, operation, and recycling—is accurately quantified. Sensitivity analysis of key raw material parameters and Monte Carlo simulation are used to further quantify the impact of uncertainty in these key sensitive parameters. Results indicate that the operational stage contributes the most to the switchgear’s carbon footprint, amounting to 24,794.77 kgCO2e, mainly due to electricity consumption. Within this stage, C4F7N gas leakage contributes minimally at 2.21 kgCO2e. The raw material acquisition stage follows with 3005.57 kgCO2e, where C4F7N gas, aluminum, and stainless steel are identified as the primary contributing materials. Sensitivity analysis shows that electricity, C4F7N, aluminum, and stainless steel are the resources that have the greatest impact on the switchgear’s carbon footprint. Compared with traditional SF6 switchgear, the C4F7N switchgear has a 23.8% lower total carbon footprint, with its total carbon footprint reaching 26,771.58 kgCO2e compared to 35,136.48 kgCO2e for SF6 switchgear. This advantage stems largely from C4F7N’s much lower global warming potential—2090 versus 25,200 for SF6—which reduces gas-related emissions by 96.6%. These findings substantiate the practical viability of C4F7N-based eco-friendly switchgear and provide strategies for the power sector to achieve a low-carbon transition.
- 30 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (17) , 9576
Open AccessLife Cycle Carbon Footprint Assessment of 12 kV C4F7N Gas-Insulated Switchgear Systems
The C4F7N eco-friendly switchgear shows significant application potential, and quantifying its carbon footprint can accelerate the low-carbon transition in the power industry. A life cycle assessment (LCA) model for a 12 kV C4F7N eco-friendly switchgear is established in this study, and the carbon footprint across four stages—raw material acquisition, transportation, operation, and recycling—is accurately quantified. Sensitivity analysis of key raw material parameters and Monte Carlo simulation are used to further quantify the impact of uncertainty in these key sensitive parameters. Results indicate that the operational stage contributes the most to the switchgear’s carbon footprint, amounting to 24,794.77 kgCO2e, mainly due to electricity consumption. Within this stage, C4F7N gas leakage contributes minimally at 2.21 kgCO2e. The raw material acquisition stage follows with 3005.57 kgCO2e, where C4F7N gas, aluminum, and stainless steel are identified as the primary contributing materials. Sensitivity analysis shows that electricity, C4F7N, aluminum, and stainless steel are the resources that have the greatest impact on the switchgear’s carbon footprint. Compared with traditional SF6 switchgear, the C4F7N switchgear has a 23.8% lower total carbon footprint, with its total carbon footprint reaching 26,771.58 kgCO2e compared to 35,136.48 kgCO2e for SF6 switchgear. This advantage stems largely from C4F7N’s much lower global warming potential—2090 versus 25,200 for SF6—which reduces gas-related emissions by 96.6%. These findings substantiate the practical viability of C4F7N-based eco-friendly switchgear and provide strategies for the power sector to achieve a low-carbon transition.
- 7 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2076-2083
Insulation Performance and Microstructural Mechanism of Self-Extinguishing Fluorinated Silicone Oil
Traditional mineral oils are widely used as liquid insulating media in power transformers, and the search for new liquid insulating media is crucial due to their limited fire resistance and biodegradability as well as the scarcity of fossil fuels. Two possible alternative media, natural insulating ester and silicone oil, have been proposed, but the relevant performance index parameters of the two need to be further optimized, and there are still more challenges to be faced when they are put into operation in transformers. In this paper, the insulating properties of three new self-extinguishing fluorinated silicone oils are investigated theoretically and experimentally and their application potential are evaluated. The results of the frequency breakdown experiments show that the insulating properties and stability of hydrogen-containing silicone fluoride oils are better than those of hydroxy silicone fluoride oils and methyl silicone fluoride oils. By constructing molecular models of the three different types of silicone fluoride oils and analyzing the bond lengths, HOMO-LUMO energy level differences, and the area of distribution of the electrostatic potentials, the results indicate that the uniformity of the electron distribution of the hydrogen-containing silicone fluoride oil molecules is superior to that of methyl silicone fluoride oils than to that of hydroxy silicone fluoride oils. The results show that due to the molecular electron distribution uniformity of hydrogen fluorinated silicone oil being better than that of methyl fluorinated silicone oil and hydroxyl fluorinated silicone oil, this leads to a difference in polarization ability between the materials, so the hydrogen fluorinated silicone oil shows better insulating properties, which provides a certain reference for the research of new liquid insulating media that can replace mineral oil.
- 7 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2076-2083
Insulation Performance and Microstructural Mechanism of Self-Extinguishing Fluorinated Silicone Oil
Traditional mineral oils are widely used as liquid insulating media in power transformers, and the search for new liquid insulating media is crucial due to their limited fire resistance and biodegradability as well as the scarcity of fossil fuels. Two possible alternative media, natural insulating ester and silicone oil, have been proposed, but the relevant performance index parameters of the two need to be further optimized, and there are still more challenges to be faced when they are put into operation in transformers. In this paper, the insulating properties of three new self-extinguishing fluorinated silicone oils are investigated theoretically and experimentally and their application potential are evaluated. The results of the frequency breakdown experiments show that the insulating properties and stability of hydrogen-containing silicone fluoride oils are better than those of hydroxy silicone fluoride oils and methyl silicone fluoride oils. By constructing molecular models of the three different types of silicone fluoride oils and analyzing the bond lengths, HOMO-LUMO energy level differences, and the area of distribution of the electrostatic potentials, the results indicate that the uniformity of the electron distribution of the hydrogen-containing silicone fluoride oil molecules is superior to that of methyl silicone fluoride oils than to that of hydroxy silicone fluoride oils. The results show that due to the molecular electron distribution uniformity of hydrogen fluorinated silicone oil being better than that of methyl fluorinated silicone oil and hydroxyl fluorinated silicone oil, this leads to a difference in polarization ability between the materials, so the hydrogen fluorinated silicone oil shows better insulating properties, which provides a certain reference for the research of new liquid insulating media that can replace mineral oil.
- 12 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2033-2042
Mechanism of the Effect of Micro-Water on the Thermal Decomposition Characteristics of C₄F₇N/CO₂/O₂ Gas Mixture
The C 4 F 7 N/CO 2 /O 2 ternary gas mixture, with its excellent environmental and insulating properties, has emerged as one of the most promising alternatives to SF 6 and has seen initial applications in global power systems. Currently, there is limited research on the stability of C 4 F 7 N/CO 2 /O 2 in equipment under long-term operation with micro-water content. This study uses reactive molecular dynamics simulations, using ReaxFF forcefield, for investigating the effect of water (up to 2%) on the thermal decomposition characteristics of C 4 F 7 N/CO 2 /O 2 at the microscopic level. Additionally, thermal decomposition experiments of C 4 F 7 N/CO 2 /O 2 under different micro-water concentrations were conducted to analyze the relationship between decomposition products and micro-water content. When the micro-water concentration is below 1.6%, H 2 O promotes the generation of O radicals, increasing the decomposition of C 4 F 7 N. However, as the H2O concentration increases further, the large amount of generated OH radicals consume O radicals, inhibiting the main decomposition reactions of C 4 F 7 N. Experimental results show that the main thermal decomposition products of the gas mixture are CF 4 , C 3 F 8 , C 3 F 6 , C 2 F 6 , and CHF 3 . The findings of this study provide theoretical support and technical foundation for enhancing the reliability of C 4 F 7 N/CO 2 /O 2 insulation equipment in long-term engineering applications.
- 12 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2033-2042
Mechanism of the Effect of Micro-Water on the Thermal Decomposition Characteristics of C₄F₇N/CO₂/O₂ Gas Mixture
The C 4 F 7 N/CO 2 /O 2 ternary gas mixture, with its excellent environmental and insulating properties, has emerged as one of the most promising alternatives to SF 6 and has seen initial applications in global power systems. Currently, there is limited research on the stability of C 4 F 7 N/CO 2 /O 2 in equipment under long-term operation with micro-water content. This study uses reactive molecular dynamics simulations, using ReaxFF forcefield, for investigating the effect of water (up to 2%) on the thermal decomposition characteristics of C 4 F 7 N/CO 2 /O 2 at the microscopic level. Additionally, thermal decomposition experiments of C 4 F 7 N/CO 2 /O 2 under different micro-water concentrations were conducted to analyze the relationship between decomposition products and micro-water content. When the micro-water concentration is below 1.6%, H 2 O promotes the generation of O radicals, increasing the decomposition of C 4 F 7 N. However, as the H2O concentration increases further, the large amount of generated OH radicals consume O radicals, inhibiting the main decomposition reactions of C 4 F 7 N. Experimental results show that the main thermal decomposition products of the gas mixture are CF 4 , C 3 F 8 , C 3 F 6 , C 2 F 6 , and CHF 3 . The findings of this study provide theoretical support and technical foundation for enhancing the reliability of C 4 F 7 N/CO 2 /O 2 insulation equipment in long-term engineering applications.
- Open Access
- 19 September 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (9) , 192
A Study Based on the First-Principle Study of the Adsorption and Sensing Properties of Mo-Doped WSe2 for N2O, CO2, and CH4
As industry continues to develop rapidly, the greenhouse effect is becoming increasingly severe. CO2, CH4, and N2O are the three primary greenhouse gases, making their effective monitoring a crucial step in reducing emissions. This paper investigates the gas sensing performance of Mo-doped WSe2 for these three gases, through a theoretical study. First, using first-principles calculations, the doping behavior of Mo in WSe2 is examined. Subsequently, the adsorption properties of Mo-WSe2 for CO2, CH4, and N2O are analyzed by calculating adsorption energy, charge transfer, the electron localization function (ELF), Hirshfeld partition (IGMH), and the density of states (DOSs), culminating in an analysis of its sensing properties. The results indicate that when Mo is positioned above the upper Se atom, the structure is most stable. Therefore, this position is selected as the optimal adsorption site for studying the adsorption of the three gases. The adsorption energies for CO2, CH4, and N2O are 1.349 eV, −1.194 eV, and −0.528 eV, respectively, with corresponding charge transfers of 0.418, 0.450, and 0.115. In the N2O and CO2 adsorption systems, significant adsorption energy and charge transfer are observed, leading to relatively better adsorption compared to the CH4 system. Additionally, considering the adsorption performance, Mo-WSe2 demonstrates good sensor response and desorption times for N2O and CO2 at temperatures above 298 K. The findings of this research provide theoretical guidance for the application of Mo-WSe2 as a gas sensing material for detecting greenhouse gases.
- 19 September 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (9) , 192
Open AccessA Study Based on the First-Principle Study of the Adsorption and Sensing Properties of Mo-Doped WSe2 for N2O, CO2, and CH4
As industry continues to develop rapidly, the greenhouse effect is becoming increasingly severe. CO2, CH4, and N2O are the three primary greenhouse gases, making their effective monitoring a crucial step in reducing emissions. This paper investigates the gas sensing performance of Mo-doped WSe2 for these three gases, through a theoretical study. First, using first-principles calculations, the doping behavior of Mo in WSe2 is examined. Subsequently, the adsorption properties of Mo-WSe2 for CO2, CH4, and N2O are analyzed by calculating adsorption energy, charge transfer, the electron localization function (ELF), Hirshfeld partition (IGMH), and the density of states (DOSs), culminating in an analysis of its sensing properties. The results indicate that when Mo is positioned above the upper Se atom, the structure is most stable. Therefore, this position is selected as the optimal adsorption site for studying the adsorption of the three gases. The adsorption energies for CO2, CH4, and N2O are 1.349 eV, −1.194 eV, and −0.528 eV, respectively, with corresponding charge transfers of 0.418, 0.450, and 0.115. In the N2O and CO2 adsorption systems, significant adsorption energy and charge transfer are observed, leading to relatively better adsorption compared to the CH4 system. Additionally, considering the adsorption performance, Mo-WSe2 demonstrates good sensor response and desorption times for N2O and CO2 at temperatures above 298 K. The findings of this research provide theoretical guidance for the application of Mo-WSe2 as a gas sensing material for detecting greenhouse gases.
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (4) , 1840-1848
Experimental and Theoretical Study of the Interaction Between SF₆/N₂ and EPDM: A Comparative Study With SF₆
Mixing nitrogen (N 2 ) into sulfur hexafluoride (SF 6 ) is considered a beneficial measure to reduce the consumption of SF 6 . Minimal interaction and airtightness are key factors in maintaining the long-term stable operation of the equipment. To provide a theoretical support for the application of EPDM in SF 6 /N 2 insulated equipment, the interaction mechanism and permeability of SF 6 /N 2 with EPDM at different temperatures are investigated. The experimental results are comparatively analyzed using FTIR and tensile properties tests. In the meantime, the bond length distribution and diffusion coefficient of gas molecules in EPDM are analyzed using molecular dynamics. The adsorption performance (adsorption energy, transfer charge and density of states) of EPDM on gas molecules are also analyzed by DFT. The results show that, the infrared spectra of the experimental groups almost overlapped before and after experiments with little gas products. The mechanical properties are slightly worse than SF 6 /N 2 . The averages of SF 6 and N 2 bond lengths at 383 K increase by 5.97% and 0.57% compared to those at 298 K, respectively. The permeation coefficient of N 2 is 5.28 times higher than that of SF 6 in SF 6 /N 2 gas mixture at room temperature. The adsorption energy and transfer charge of EPDM on the SF 6 (-0.902 eV, 0.0456 e) are higher than those of the N 2 (-0.214 eV, 0.0204 e) indicating that EPDM has a stronger adsorption effect on SF 6 . The analysis of the density of states further confirms it. The interaction between EPDM and SF 6 as well as N 2 is mainly van der Waals force and a small amount of hydrogen bonding, and the force strength of SF 6 is stronger than that of N 2 . Overall, the interaction of EPDM with both SF 6 and N 2 is minimal. However, it is necessary to take appropriate measures to prevent SF 6 and N 2 leakage.
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (4) , 1840-1848
Experimental and Theoretical Study of the Interaction Between SF₆/N₂ and EPDM: A Comparative Study With SF₆
Mixing nitrogen (N 2 ) into sulfur hexafluoride (SF 6 ) is considered a beneficial measure to reduce the consumption of SF 6 . Minimal interaction and airtightness are key factors in maintaining the long-term stable operation of the equipment. To provide a theoretical support for the application of EPDM in SF 6 /N 2 insulated equipment, the interaction mechanism and permeability of SF 6 /N 2 with EPDM at different temperatures are investigated. The experimental results are comparatively analyzed using FTIR and tensile properties tests. In the meantime, the bond length distribution and diffusion coefficient of gas molecules in EPDM are analyzed using molecular dynamics. The adsorption performance (adsorption energy, transfer charge and density of states) of EPDM on gas molecules are also analyzed by DFT. The results show that, the infrared spectra of the experimental groups almost overlapped before and after experiments with little gas products. The mechanical properties are slightly worse than SF 6 /N 2 . The averages of SF 6 and N 2 bond lengths at 383 K increase by 5.97% and 0.57% compared to those at 298 K, respectively. The permeation coefficient of N 2 is 5.28 times higher than that of SF 6 in SF 6 /N 2 gas mixture at room temperature. The adsorption energy and transfer charge of EPDM on the SF 6 (-0.902 eV, 0.0456 e) are higher than those of the N 2 (-0.214 eV, 0.0204 e) indicating that EPDM has a stronger adsorption effect on SF 6 . The analysis of the density of states further confirms it. The interaction between EPDM and SF 6 as well as N 2 is mainly van der Waals force and a small amount of hydrogen bonding, and the force strength of SF 6 is stronger than that of N 2 . Overall, the interaction of EPDM with both SF 6 and N 2 is minimal. However, it is necessary to take appropriate measures to prevent SF 6 and N 2 leakage.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1647-1650
Numerical Simulation of Phase Transition Evolution of Evaporative Cooling Medium C₆F₁₂O Under Inhomogeneous Electric Field
C 6 F 12 O, an environmentally friendly medium, is non-flammable and non-explosive with excellent insulating properties. Moreover, it is economically favourable for phase change cooling technology which offers safe and efficient heat dissipation for high-power, large-capacity electrical equipment. Despite its potential, the application of C 6 F 12 O as a cooling medium is nascent. The work employs numerical simulation to consider the mutual coupling effects of the electric-flow-thermal-phase fields, and investigates the influence of temperature and inhomogeneous electric fields on the evolution of bubble motion during the boiling process of the C 6 F 12 O medium. Typical characteristic parameters of bubble motion are obtained, and the analysis of the inherent connection between bubble release rate and motion speed is conducted to predict the formation of bubble channels. Numerical results indicate that higher temperatures and Electric Bond numbers ( BoE ) enhance the release frequency and velocity of C 6 F 12 O bubbles. The inhomogeneous electric field increases the stretching degree of bubble release, facilitating faster detachment. Furthermore, a warning coefficient D is proposed to characterize the generation of bubble channels, which signifies the speed and frequency of bubble motion. The D value below 7 signals potential insulation performance degradation, necessitating caution; ideally, the value of D should be maintained between 10 and 15 during standard equipment operation. Our findings offer theoretical insights for the practical implementation of C 6 F 12 O-based phase change cooling technology.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1647-1650
Numerical Simulation of Phase Transition Evolution of Evaporative Cooling Medium C₆F₁₂O Under Inhomogeneous Electric Field
C 6 F 12 O, an environmentally friendly medium, is non-flammable and non-explosive with excellent insulating properties. Moreover, it is economically favourable for phase change cooling technology which offers safe and efficient heat dissipation for high-power, large-capacity electrical equipment. Despite its potential, the application of C 6 F 12 O as a cooling medium is nascent. The work employs numerical simulation to consider the mutual coupling effects of the electric-flow-thermal-phase fields, and investigates the influence of temperature and inhomogeneous electric fields on the evolution of bubble motion during the boiling process of the C 6 F 12 O medium. Typical characteristic parameters of bubble motion are obtained, and the analysis of the inherent connection between bubble release rate and motion speed is conducted to predict the formation of bubble channels. Numerical results indicate that higher temperatures and Electric Bond numbers ( BoE ) enhance the release frequency and velocity of C 6 F 12 O bubbles. The inhomogeneous electric field increases the stretching degree of bubble release, facilitating faster detachment. Furthermore, a warning coefficient D is proposed to characterize the generation of bubble channels, which signifies the speed and frequency of bubble motion. The D value below 7 signals potential insulation performance degradation, necessitating caution; ideally, the value of D should be maintained between 10 and 15 during standard equipment operation. Our findings offer theoretical insights for the practical implementation of C 6 F 12 O-based phase change cooling technology.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3067-3073
Relevance Analysis Between Decomposition Product Characteristics of C₆F₁₂O Gas Mixture Under Partial Discharge and Insulation Faults
C 6 F 12 O/CO 2 gas mixture possesses the potential for application in medium to low voltage equipment. However, during equipment operation, insulation defects caused by various factors can result in partial discharge (PD), causing the C 6 F 12 O/CO 2 gas mixture to decompose. Therefore, the study of the properties of decomposition products under partial discharge of C 6 F 12 O/CO 2 gas mixture is of great significance for the identification of insulation faults. Four typical insulation defects are selected and PD decomposition experiments are carried out under different voltages for different defects of C 6 F 12 O/CO 2 gas mixture. Using gas chromatography, decomposition products such as CF 4 , C 2 F 6 , C 3 F 8 , and C 3 F 7 H are detected and the changing patterns of four typical decomposition products under different insulation defects are determined. The concentration ratios of C 2 F 6 /C 3 F 8 and CF 4 /C 3 F 7 H are plotted as two-dimensional coordinates X and Y, respectively, and the distribution of product concentration ratios under different defects is shown. A coding tree for identifying types of insulation defects has been constructed. Additionally, combining (CF 4 +C 2 F 6 +C 3 F 8 )/C 3 F 7 H and CF 4 /C 3 F 7 H with the decomposition product rate allows for a comprehensive assessment of the PD strength. This study provides effective means for diagnosing insulation faults in C 6 F 12 O/CO 2 gas mixture insulation equipment.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3067-3073
Relevance Analysis Between Decomposition Product Characteristics of C₆F₁₂O Gas Mixture Under Partial Discharge and Insulation Faults
C 6 F 12 O/CO 2 gas mixture possesses the potential for application in medium to low voltage equipment. However, during equipment operation, insulation defects caused by various factors can result in partial discharge (PD), causing the C 6 F 12 O/CO 2 gas mixture to decompose. Therefore, the study of the properties of decomposition products under partial discharge of C 6 F 12 O/CO 2 gas mixture is of great significance for the identification of insulation faults. Four typical insulation defects are selected and PD decomposition experiments are carried out under different voltages for different defects of C 6 F 12 O/CO 2 gas mixture. Using gas chromatography, decomposition products such as CF 4 , C 2 F 6 , C 3 F 8 , and C 3 F 7 H are detected and the changing patterns of four typical decomposition products under different insulation defects are determined. The concentration ratios of C 2 F 6 /C 3 F 8 and CF 4 /C 3 F 7 H are plotted as two-dimensional coordinates X and Y, respectively, and the distribution of product concentration ratios under different defects is shown. A coding tree for identifying types of insulation defects has been constructed. Additionally, combining (CF 4 +C 2 F 6 +C 3 F 8 )/C 3 F 7 H and CF 4 /C 3 F 7 H with the decomposition product rate allows for a comprehensive assessment of the PD strength. This study provides effective means for diagnosing insulation faults in C 6 F 12 O/CO 2 gas mixture insulation equipment.