Guiying Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Guiying Wu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Li Sun
National Engineering Research Center of Power Generation Control and Safety, School of Energy and Environment, Southeast University, Nanjing 210096, China
3 shared publications Kwang Y. Lee
Department of Electrical and Computer Engineering, Baylor University, Waco, TX, USA
2 shared publications- Kwang Y. Lee
Department of Electrical and Computer Engineering, Baylor University, Waco, TX, USA
2 shared publications Yali Xue
State Key Lab for Power Systems, Tsinghua University, Beijing, China
2 shared publicationsDonghai Li
State Key Lab for Power Systems, Tsinghua University, Beijing, China
1 shared publication- Donghai Li
State Key Laboratory of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100084, China
1 shared publication
Latest Publications
- 20 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (1) , 1-9
Coordinated Control Strategies for Fuel Cell Power Plant in a Microgrid
Solid-oxide fuel cell (SOFC) power plant plays a vital role in a hybrid alternative energy based microgrid due to its reliability and flexibility in power supply. However, the control of SOFC is challenging in terms of providing a fast load tracking while maintaining the fuel utilization rate within a safe range. To this end, this paper builds two basic coordinated control strategies (CCS) for power management of SOFC-based microgrid. The first is “Fuel Cell follows Inverter” scheme, where fast tracking is preferred while SOFC may operate on the edge of the safety range. The second is “Inverter follows Fuel Cell” scheme, where high security is guaranteed by sacrificing performance in load tracking. To obtain a robust and simple scheme, energy balance principle is used in CCS such that PI controller is sufficient to fulfill the basic duties. Moreover, a simple supervisory control strategy is proposed for microgrid to provide a reasonable power reference for SOFC. The control system is designed and tuned based on an SOFC plant with inverter's average model. The efficiency of the proposed strategies is validated via a grid-connected SOFC/photovoltaic microgrid.
- 20 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (1) , 1-9
Coordinated Control Strategies for Fuel Cell Power Plant in a Microgrid
Solid-oxide fuel cell (SOFC) power plant plays a vital role in a hybrid alternative energy based microgrid due to its reliability and flexibility in power supply. However, the control of SOFC is challenging in terms of providing a fast load tracking while maintaining the fuel utilization rate within a safe range. To this end, this paper builds two basic coordinated control strategies (CCS) for power management of SOFC-based microgrid. The first is “Fuel Cell follows Inverter” scheme, where fast tracking is preferred while SOFC may operate on the edge of the safety range. The second is “Inverter follows Fuel Cell” scheme, where high security is guaranteed by sacrificing performance in load tracking. To obtain a robust and simple scheme, energy balance principle is used in CCS such that PI controller is sufficient to fulfill the basic duties. Moreover, a simple supervisory control strategy is proposed for microgrid to provide a reasonable power reference for SOFC. The control system is designed and tuned based on an SOFC plant with inverter's average model. The efficiency of the proposed strategies is validated via a grid-connected SOFC/photovoltaic microgrid.
- Open Access
- 1 July 2017
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 50 (1) , 5554-5559
Coordinated Fuzzy Logic Control Strategy for Hybrid PV Array with Fuel-Cell and Ultra-Capacitor in a Microgrid
- 1 July 2017
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 50 (1) , 5554-5559
Open AccessCoordinated Fuzzy Logic Control Strategy for Hybrid PV Array with Fuel-Cell and Ultra-Capacitor in a Microgrid
- 1 January 2015
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 48 (30) , 445-449
A Practical Compound Controller Design for Solid Oxide Fuel Cells
- 1 January 2015
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 48 (30) , 445-449
A Practical Compound Controller Design for Solid Oxide Fuel Cells
- 1 January 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Modeling and control of power conditioning system for grid-connected Fuel Cell power plant
This paper introduces a power conditioning system (PCS) for the Fuel Cell power plant. The PCS is an interface between distributed generation and utility grid. The proposed system has DC/DC converter, DC/AC inverter, and LCL filter. The DC/DC converter and DC/AC inverter use switches that operate at high speeds. The use of detailed model with switches will decrease the simulation speed, and thus it takes long time to execute time simulations in MATLAB. This paper presents effective average models for DC/DC converter and DC/AC inverter to reduce the calculation time in MATLAB. This helps significantly in reducing execution time when implemented for a large-scale fuel cell power plant.
- 1 January 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Modeling and control of power conditioning system for grid-connected Fuel Cell power plant
This paper introduces a power conditioning system (PCS) for the Fuel Cell power plant. The PCS is an interface between distributed generation and utility grid. The proposed system has DC/DC converter, DC/AC inverter, and LCL filter. The DC/DC converter and DC/AC inverter use switches that operate at high speeds. The use of detailed model with switches will decrease the simulation speed, and thus it takes long time to execute time simulations in MATLAB. This paper presents effective average models for DC/DC converter and DC/AC inverter to reduce the calculation time in MATLAB. This helps significantly in reducing execution time when implemented for a large-scale fuel cell power plant.