Miloš Kalousek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Miloš Kalousek has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Martin Němeček
Brno University of Technology
4 shared publications- Anna Igorevna Rybakova
Russian Academy of Sciences
2 shared publications Lukáš Chuchma
Brno University of Technology
2 shared publicationsMarie Rusinová
Brno University of Technology
2 shared publications- Miroslav Čekon
Slovak Academy of Sciences
2 shared publications Radek Partika
VSB- Technical University of Ostrava
2 shared publications
Latest Publications
- 21 December 2025
- Published by Springer Nature
- p. 533-540
The Assessment of Details of Existing Building Structures with the Addition of a Thermally Conductive Element
- 21 December 2025
- Published by Springer Nature
- p. 533-540
The Assessment of Details of Existing Building Structures with the Addition of a Thermally Conductive Element
- Open Access
- 29 September 2023
- Published by University of Zagreb, Faculty of Forestry and Wood Technology in Drvna industrija
- Vol. 74 (3) , 369-377
Analiza utjecaja protupožarne obloge na bazi gipsa na pougljenje drvenih nosivih elemenata
Fire resistance of load-bearing wooden structures is evaluated by the charring of surface layers of wooden bearing elements. The degree of resistance is determined by the onset and course of charring; these basic parameters are affected by the cover...
- 29 September 2023
- Published by University of Zagreb, Faculty of Forestry and Wood Technology in Drvna industrija
- Vol. 74 (3) , 369-377
Open AccessAnaliza utjecaja protupožarne obloge na bazi gipsa na pougljenje drvenih nosivih elemenata
Fire resistance of load-bearing wooden structures is evaluated by the charring of surface layers of wooden bearing elements. The degree of resistance is determined by the onset and course of charring; these basic parameters are affected by the cover...
- 25 January 2019
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 887, 98-105
Assessment of the Dynamic Temperature Profile in Fire Loaded Sandwich Structures Based on Wood in Comparison with Conventional Structural Systems
Fire safety is an important feature of healthy internal environment. If a fire breaks out, the interior of fire compartments within the building is exposed to very high temperatures and further phenomena accompanying the burning process. All of them impact the boundaries of the compartment structures, including the structures that are located inside them. Some structures serve the load bearing function hand in hand with fire barriers, some are only fire barriers. As to the dramatic increase of temperature, its impact upon the opposite surface of the fire separating structure should be considered, in particular regarding the behavior of the load bearing elements and their stability. This is topical at the present day, since the conventional construction materials are seen to give way to wooden sandwich structures that are preferred especially for their thermal insulation properties, low weight, small thickness and speediness of construction. The article uses dynamic simulation to illustrate how these modern structures react to high temperatures within specific time intervals, offering comparisons with traditional brick structures.
- 25 January 2019
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 887, 98-105
Assessment of the Dynamic Temperature Profile in Fire Loaded Sandwich Structures Based on Wood in Comparison with Conventional Structural Systems
Fire safety is an important feature of healthy internal environment. If a fire breaks out, the interior of fire compartments within the building is exposed to very high temperatures and further phenomena accompanying the burning process. All of them impact the boundaries of the compartment structures, including the structures that are located inside them. Some structures serve the load bearing function hand in hand with fire barriers, some are only fire barriers. As to the dramatic increase of temperature, its impact upon the opposite surface of the fire separating structure should be considered, in particular regarding the behavior of the load bearing elements and their stability. This is topical at the present day, since the conventional construction materials are seen to give way to wooden sandwich structures that are preferred especially for their thermal insulation properties, low weight, small thickness and speediness of construction. The article uses dynamic simulation to illustrate how these modern structures react to high temperatures within specific time intervals, offering comparisons with traditional brick structures.
- 5 December 2016
- Published by Trans Tech Publications, Ltd.
Buildings and Environment - Energy Performance, Smart Materials and Buildings
The volume was collected by results of Conference "Buildings and Environment" (enviBUILD 2016, 22nd – 23rd September 2016, Brno, Czech Republic). This volume presents scientific works in the field of building technologies and quality of indoor environment. Also included are works describing new advanced materials and technologies and sustainable construction. Most of the presented works focus on the built environment of the Central Europe Region but however their results are universally applicable.
- 5 December 2016
- Published by Trans Tech Publications, Ltd.
Buildings and Environment - Energy Performance, Smart Materials and Buildings
The volume was collected by results of Conference "Buildings and Environment" (enviBUILD 2016, 22nd – 23rd September 2016, Brno, Czech Republic). This volume presents scientific works in the field of building technologies and quality of indoor environment. Also included are works describing new advanced materials and technologies and sustainable construction. Most of the presented works focus on the built environment of the Central Europe Region but however their results are universally applicable.
- 1 December 2016
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 861, 409-416
Effect of Ventilation in Protected Escape Ways upon the Thermal Properties of these Spaces
Protected escape routes enable the rescuing of persons to the outside of a building on fire. They are characterized, in particular, by strict requirements relating to the aeration of such spaces. However, the fulfilling of these limits may impact the monitored thermal characteristics of the respective internal areas. The outlined dilemma will be illustrated by way of an example of a protected escape route aerated by positive-pressure ventilation.
- 1 December 2016
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 861, 409-416
Effect of Ventilation in Protected Escape Ways upon the Thermal Properties of these Spaces
Protected escape routes enable the rescuing of persons to the outside of a building on fire. They are characterized, in particular, by strict requirements relating to the aeration of such spaces. However, the fulfilling of these limits may impact the monitored thermal characteristics of the respective internal areas. The outlined dilemma will be illustrated by way of an example of a protected escape route aerated by positive-pressure ventilation.
- 1 January 2016
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 824, 803-810
Exploitability of Renewable Resources in Administrative Buildings
The evaluation of energy flow measurements in two very special buildings under the name of Open Gardens, located in Brno, resulted in confirming that the resources of renewable energy in the Czech Republic can be sufficiently utilized. This energy is derived from photovoltaic elements and earth heat pumps and, additionally, it gets also accumulated in building structures. The energy from renewable resources is utilized for heating, cooling, warm water preparation, for raising air temperature, and it also partially covers the demand for electricity in the building. During the summer period, if the solar gains are considerable, the buildings need being cooled. This is ensured by an earth heat pump enabling the storage of waste heat in deep earth bore holes, offering the advantage of recuperating the heat for heating the rooms during the winter months. At the same time all electricity produced in the building gets utilized, covering roughly 1/3 of the consumption. A plan of comprehensive measurements aiming at the optimization of the most demanding electric appliances has been conceived for this compound of buildings, in order to ensure the best possible utilization of the produced electricity.
- 1 January 2016
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 824, 803-810
Exploitability of Renewable Resources in Administrative Buildings
The evaluation of energy flow measurements in two very special buildings under the name of Open Gardens, located in Brno, resulted in confirming that the resources of renewable energy in the Czech Republic can be sufficiently utilized. This energy is derived from photovoltaic elements and earth heat pumps and, additionally, it gets also accumulated in building structures. The energy from renewable resources is utilized for heating, cooling, warm water preparation, for raising air temperature, and it also partially covers the demand for electricity in the building. During the summer period, if the solar gains are considerable, the buildings need being cooled. This is ensured by an earth heat pump enabling the storage of waste heat in deep earth bore holes, offering the advantage of recuperating the heat for heating the rooms during the winter months. At the same time all electricity produced in the building gets utilized, covering roughly 1/3 of the consumption. A plan of comprehensive measurements aiming at the optimization of the most demanding electric appliances has been conceived for this compound of buildings, in order to ensure the best possible utilization of the produced electricity.
- 1 January 2016
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 824, 544-551
Summer Thermal Stability of a Passive House in Moravany - The Czech Republic and Thermal Storage Mass
The article describes the summer thermal stability of a semidetached passive house in Moravany - Czech Republic. Long-term measurement was carried out on the uninhabited house. The house is divided into two symmetrically identical residential units. Indoor air temperature differences of these symmetrically identical rooms are compared. Comparative numerical simulation was also carried out.
- 1 January 2016
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 824, 544-551
Summer Thermal Stability of a Passive House in Moravany - The Czech Republic and Thermal Storage Mass
The article describes the summer thermal stability of a semidetached passive house in Moravany - Czech Republic. Long-term measurement was carried out on the uninhabited house. The house is divided into two symmetrically identical residential units. Indoor air temperature differences of these symmetrically identical rooms are compared. Comparative numerical simulation was also carried out.
- 1 November 2015
- Published by Elsevier in Energy and Buildings
- Vol. 107, 68-75
Influence of thermal storage mass on summer thermal stability in a passive wooden house in the Czech Republic
- 1 November 2015
- Published by Elsevier in Energy and Buildings
- Vol. 107, 68-75
Influence of thermal storage mass on summer thermal stability in a passive wooden house in the Czech Republic
- 27 October 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1041, 175-179
Influence of Window on Solar Gains and Daylight Level
Energy savings led to design requirements for buildings with thermally insulated envelopes. Window glazing with better thermal insulation properties have in many cases reduced transmittance of solar radiation. They decrease solar thermal gains and daylight level in buildings. A study of influence of selected windows on solar gains and daylighting in a reference room is presented in the paper.
- 27 October 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1041, 175-179
Influence of Window on Solar Gains and Daylight Level
Energy savings led to design requirements for buildings with thermally insulated envelopes. Window glazing with better thermal insulation properties have in many cases reduced transmittance of solar radiation. They decrease solar thermal gains and daylight level in buildings. A study of influence of selected windows on solar gains and daylighting in a reference room is presented in the paper.
- 27 October 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1041, 171-174
Modeling of Details for Single-Layer Wall in a Passive House: The Case of Balcony Slab
The balcony is one of the main reasons of the increased heat loss. The presence of thermal bridge in constructions of balcony envelopes influences the energy consumption, durability of the building envelopes, and also the thermal comfort of occupants. If the balcony construction is performed of a metal back slab it would be hardly possible to avoid the formation of a powerful thermal bridge that will go along the whole balcony length. This problem could be solved by using of thermal insulating element for connecting cantilevered steel components to wall. An investigation into the various performance criteria concerning the effectiveness of steel balcony connections to reinforced concrete wall, has been carried out in our article.
- 27 October 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1041, 171-174
Modeling of Details for Single-Layer Wall in a Passive House: The Case of Balcony Slab
The balcony is one of the main reasons of the increased heat loss. The presence of thermal bridge in constructions of balcony envelopes influences the energy consumption, durability of the building envelopes, and also the thermal comfort of occupants. If the balcony construction is performed of a metal back slab it would be hardly possible to avoid the formation of a powerful thermal bridge that will go along the whole balcony length. This problem could be solved by using of thermal insulating element for connecting cantilevered steel components to wall. An investigation into the various performance criteria concerning the effectiveness of steel balcony connections to reinforced concrete wall, has been carried out in our article.