Ponnusamy Pandithevan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ponnusamy Pandithevan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Varatharajan Prasannavenkadesan
School of Mechanical and Aerospace Engineering, Queen’s University
7 shared publications- Varatharajan Prasannavenkadesan
Queen Mary University of London
2 shared publications - Gurunathan Saravana Kumar
Department of Engineering Design, Indian Institute of Technology Madras, Chennai, India
1 shared publication N. A. Jaseem Sajidh
Department of Mechanical Engineering, Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram , Chennai, Tamil Nadu 600127, India
1 shared publication- N. A. Jaseem Sajidh
Indian Institute of Information Technology, Design and Manufacturing Kancheepuram
1 shared publication Natarajan Vinayaga Muruga Pandy
Department of Mechanical Engineering, Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram, Chennai 600127, Tamilnadu, India
1 shared publication
Latest Publications
- 18 March 2026
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 148 (6) , 1-31
Mechanistic Model to Predict Forces in Bone End Milling: An Experimental Study Intended for Bone Grafting Surgery
In orthopedic surgery, subtractive manufacturing processes, such as drilling, sawing, grinding, and milling, are employed for implant placement, fracture fixation, and reconstruction surgery. If the forces resulting from the bone cutting processes are uncontrolled, mechanical damage (e.g., microcracks and bone fragmentations) is observed in the local host bone. In this study, the use of the end milling process for harvesting bone grafts was investigated. Importantly, the mechanistic model for the prediction of bone end milling forces was developed, considering the axial, tangential, and radial force components, geometry of the end milling cutter, and mechanical properties of the bone. First, an analytical description of the milling forces resulting from the end milling process was developed. Second, the cutting and edge force coefficients were calculated. Third, the axial, tangential, and radial forces resulting from the end mill cutter were predicted from the mechanistic model. To validate the end milling forces predicted from the mechanistic model, different sets of experiments were conducted. It was verified that the forces predicted from the mechanistic model agreed well with the validation experiments. The outcomes of this study can be used to pre-estimate the forces resulting from the end milling cutter, and therefore, mechanical damage can be avoided.
- 18 March 2026
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 148 (6) , 1-31
Mechanistic Model to Predict Forces in Bone End Milling: An Experimental Study Intended for Bone Grafting Surgery
In orthopedic surgery, subtractive manufacturing processes, such as drilling, sawing, grinding, and milling, are employed for implant placement, fracture fixation, and reconstruction surgery. If the forces resulting from the bone cutting processes are uncontrolled, mechanical damage (e.g., microcracks and bone fragmentations) is observed in the local host bone. In this study, the use of the end milling process for harvesting bone grafts was investigated. Importantly, the mechanistic model for the prediction of bone end milling forces was developed, considering the axial, tangential, and radial force components, geometry of the end milling cutter, and mechanical properties of the bone. First, an analytical description of the milling forces resulting from the end milling process was developed. Second, the cutting and edge force coefficients were calculated. Third, the axial, tangential, and radial forces resulting from the end mill cutter were predicted from the mechanistic model. To validate the end milling forces predicted from the mechanistic model, different sets of experiments were conducted. It was verified that the forces predicted from the mechanistic model agreed well with the validation experiments. The outcomes of this study can be used to pre-estimate the forces resulting from the end milling cutter, and therefore, mechanical damage can be avoided.
- 28 October 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (12) , 1-41
Identification of Johnson–Cook Model Parameters for Human Cortical Bone Using Inverse Finite Element Method to Practice and Rehearse Surgical Operations
Constitutive models (CMs) are used to predict material-specific relationships, such as stress and strain, through computer simulation. Although constitutive models, such as Johnson–Cook, Cowper–Symonds, modified Johnson–Cook, and Arrhenius, were used to simulate the behavior of animal bones and surrogate materials, the outcomes predicted from such models cannot be directly applied to human bone, as they were developed from animal and bone surrogate materials. Therefore, this is the first study to identify the Johnson–Cook model (JC-M) parameters for human cortical bone using the inverse finite element method (FEM). As a procedure, the initial value with upper and lower bounds for each of the parameters involved in the Johnson–Cook model was assigned for the simulation, and then the parameter values that could best represent the human cortical bone were determined using the Levenberg–Marquardt optimization algorithm (LMOA). To evaluate the results, tensile test simulations were carried out at various strain rates (0.00001–1/s); the results obtained from the simulations were shown to agree well with the experiments. A case study to demonstrate the orthogonal bone cutting was also conducted, which justified the demand for the Johnson–Cook model parameters of the human cortical bone. The findings of this study could be used to simulate complex surgical operations, and thus, the surgical rehearsal and practice could be carried out in silico without conducting experiments on human or animal bones.
- 28 October 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (12) , 1-41
Identification of Johnson–Cook Model Parameters for Human Cortical Bone Using Inverse Finite Element Method to Practice and Rehearse Surgical Operations
Constitutive models (CMs) are used to predict material-specific relationships, such as stress and strain, through computer simulation. Although constitutive models, such as Johnson–Cook, Cowper–Symonds, modified Johnson–Cook, and Arrhenius, were used to simulate the behavior of animal bones and surrogate materials, the outcomes predicted from such models cannot be directly applied to human bone, as they were developed from animal and bone surrogate materials. Therefore, this is the first study to identify the Johnson–Cook model (JC-M) parameters for human cortical bone using the inverse finite element method (FEM). As a procedure, the initial value with upper and lower bounds for each of the parameters involved in the Johnson–Cook model was assigned for the simulation, and then the parameter values that could best represent the human cortical bone were determined using the Levenberg–Marquardt optimization algorithm (LMOA). To evaluate the results, tensile test simulations were carried out at various strain rates (0.00001–1/s); the results obtained from the simulations were shown to agree well with the experiments. A case study to demonstrate the orthogonal bone cutting was also conducted, which justified the demand for the Johnson–Cook model parameters of the human cortical bone. The findings of this study could be used to simulate complex surgical operations, and thus, the surgical rehearsal and practice could be carried out in silico without conducting experiments on human or animal bones.
- 4 March 2025
- Published by Taylor & Francis in Machining Science and Technology
- Vol. 29 (2) , 159-186
Dimpled drill-bit to minimize thrust-force in bone drilling with in-vitro experimental validation
- 4 March 2025
- Published by Taylor & Francis in Machining Science and Technology
- Vol. 29 (2) , 159-186
Dimpled drill-bit to minimize thrust-force in bone drilling with in-vitro experimental validation
- 23 August 2024
- Published by Springer Nature
- p. 85-93
Finite Element Analysis of Pelvic Stability to Predict Post-trapdoor Risk During Bone Grafting Procedure
- 23 August 2024
- Published by Springer Nature
- p. 85-93
Finite Element Analysis of Pelvic Stability to Predict Post-trapdoor Risk During Bone Grafting Procedure
- 23 August 2024
- Published by Springer Nature
- p. 49-60
Investigation on In Situ Bone Temperature Induced During End-Milling Process: A Study Intended for Bone Grafting
- 23 August 2024
- Published by Springer Nature
- p. 49-60
Investigation on In Situ Bone Temperature Induced During End-Milling Process: A Study Intended for Bone Grafting
- 23 August 2024
- Published by Springer Nature
- p. 353-361
Texturing on Drill Tool Flank Surface for Force Reduction in Surgical Drilling Procedure
- 23 August 2024
- Published by Springer Nature
- p. 353-361
Texturing on Drill Tool Flank Surface for Force Reduction in Surgical Drilling Procedure
- 15 July 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 24 (01)
A NON-INVASIVE METHOD TO RECONSTRUCT PATIENT-SPECIFIC HUMAN FEMUR WITH IN-SITU DRILLING TEMPERATURE DATA USING PROBABILITY DENSITY FUNCTION
Drilling through bone is widely performed in orthopedic surgeries to fix the plate and implant using bone screws. Clinical observation revealed that the mechanical and thermal damages driven by the uncontrolled drilling operations loosen the implants soon after their fixations. During fracture treatment and reconstruction surgery, the quality of the hole generated is to be considered as an important metric, and therefore drill feed rate and spindle speed, apparent bone density, drill bit geometry, and skill of the surgeon are the parameters to influence the success of the bone drilling procedure. The generation of temperature due to the conversion of mechanical work around the osteotomy site leads to irreversible thermal damage to the bone tissue, when it exceeds 47∘C. So, a non-invasive method which can identify the probability to not get a thermal osteonecrosis at the chosen drill spot can help the surgeon to strongly fix the implant around the defect site. To make this happen, the in-situ bone temperatures measured in the earlier study when drilling with a 3.20[ ]mm diameter drill bit was used for the investigation. As a procedure, the test statistics and critical test statistics values were calculated, and found that the log normal and gamma density functions could best describe the bone drilling temperatures, when drilling in the radial and circumferential directions, respectively. Additionally, the CT data sets of the patient-specific femur were used to reconstruct the bone both with geometry and drilling temperature data. The Kolmogrov–Smirnov test performed to check the validity of the temperature distribution models showed a good agreement with the experimental results. The outcomes of the method can help the surgeon to choose a suitable location for the strongest fixation using CT data sets of the patient as the only input.
- 15 July 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 24 (01)
A NON-INVASIVE METHOD TO RECONSTRUCT PATIENT-SPECIFIC HUMAN FEMUR WITH IN-SITU DRILLING TEMPERATURE DATA USING PROBABILITY DENSITY FUNCTION
Drilling through bone is widely performed in orthopedic surgeries to fix the plate and implant using bone screws. Clinical observation revealed that the mechanical and thermal damages driven by the uncontrolled drilling operations loosen the implants soon after their fixations. During fracture treatment and reconstruction surgery, the quality of the hole generated is to be considered as an important metric, and therefore drill feed rate and spindle speed, apparent bone density, drill bit geometry, and skill of the surgeon are the parameters to influence the success of the bone drilling procedure. The generation of temperature due to the conversion of mechanical work around the osteotomy site leads to irreversible thermal damage to the bone tissue, when it exceeds 47∘C. So, a non-invasive method which can identify the probability to not get a thermal osteonecrosis at the chosen drill spot can help the surgeon to strongly fix the implant around the defect site. To make this happen, the in-situ bone temperatures measured in the earlier study when drilling with a 3.20[ ]mm diameter drill bit was used for the investigation. As a procedure, the test statistics and critical test statistics values were calculated, and found that the log normal and gamma density functions could best describe the bone drilling temperatures, when drilling in the radial and circumferential directions, respectively. Additionally, the CT data sets of the patient-specific femur were used to reconstruct the bone both with geometry and drilling temperature data. The Kolmogrov–Smirnov test performed to check the validity of the temperature distribution models showed a good agreement with the experimental results. The outcomes of the method can help the surgeon to choose a suitable location for the strongest fixation using CT data sets of the patient as the only input.
- 30 October 2022
- Published by Springer Nature
- p. 151-162
Finite Element Analysis to Determine Pull-Out Strength of Fixation Around Large Defect Site in Femur Reconstruction Surgery
- 30 October 2022
- Published by Springer Nature
- p. 151-162
Finite Element Analysis to Determine Pull-Out Strength of Fixation Around Large Defect Site in Femur Reconstruction Surgery
- 21 June 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 235 (6) , 1984-1997
Mechanistic models to predict thrust force and torque in bone drilling: An in-vitro study validated with robot-assisted surgical drilling parameters
Compression plates are widely used in orthopaedic surgeries for internal fixation of fractured femurs. To fix the plate and thus to provide compression to a fracture, the self-tapping bone screws are tightened through predrilled pilot holes of smaller diameter. Preliminary investigation showed that the holes drilled with the inappropriate cutting parameters cause mechanical and thermal damages to the local host bone, which further lead to loosening of internal fixations. In this paper, the mechanistic models to predict the thrust forces and torques during bone drilling were developed, using a 3.20 mm diameter drill bit. As a procedure, the cutting action was investigated at three different regions of the drill point, namely cutting lips, secondary cutting edges and indentation zone. The models employed the analytical approach to account for the drill-bit geometry and cutting parameters, and an empirical approach to account for the material and friction properties. To complete the procedure, calibration experiments were conducted on bovine cortical femurs with two different spindle speeds (1000 and 3000 r/min) and feeds (0.03 and 0.06 mm/rev), and then the specific normal and friction coefficients were determined. The developed mechanistic models were validated with different ranges of parameters (500–3500 r/min speeds, and 0.02–0.07 mm/rev feeds) those commonly involved in manual and robot-assisted surgery. The validation study revealed that the thrust forces predicted using the mechanistic models showed a maximum error of only 5.80%. However, the torques predicted from the mechanistic model found with more error than the thrust forces. The predominant reasons for this under-prediction might because of the extrapolation used to determine the specific cutting pressures, slip-line field applied to the indentation zone instead of compressive fracture, and chip clogging involved during the bone drilling as demonstrated in earlier studies. Despite the deviations, the developed mechanistic models satisfactorily follow the trends of the thrust forces and torques experienced during bone drilling. The outcomes can be used to practice the bone drilling procedure and monitor the effect of process parameters on thrust forces and torques in the in-silico environment before performing actual surgery.
- 21 June 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 235 (6) , 1984-1997
Mechanistic models to predict thrust force and torque in bone drilling: An in-vitro study validated with robot-assisted surgical drilling parameters
Compression plates are widely used in orthopaedic surgeries for internal fixation of fractured femurs. To fix the plate and thus to provide compression to a fracture, the self-tapping bone screws are tightened through predrilled pilot holes of smaller diameter. Preliminary investigation showed that the holes drilled with the inappropriate cutting parameters cause mechanical and thermal damages to the local host bone, which further lead to loosening of internal fixations. In this paper, the mechanistic models to predict the thrust forces and torques during bone drilling were developed, using a 3.20 mm diameter drill bit. As a procedure, the cutting action was investigated at three different regions of the drill point, namely cutting lips, secondary cutting edges and indentation zone. The models employed the analytical approach to account for the drill-bit geometry and cutting parameters, and an empirical approach to account for the material and friction properties. To complete the procedure, calibration experiments were conducted on bovine cortical femurs with two different spindle speeds (1000 and 3000 r/min) and feeds (0.03 and 0.06 mm/rev), and then the specific normal and friction coefficients were determined. The developed mechanistic models were validated with different ranges of parameters (500–3500 r/min speeds, and 0.02–0.07 mm/rev feeds) those commonly involved in manual and robot-assisted surgery. The validation study revealed that the thrust forces predicted using the mechanistic models showed a maximum error of only 5.80%. However, the torques predicted from the mechanistic model found with more error than the thrust forces. The predominant reasons for this under-prediction might because of the extrapolation used to determine the specific cutting pressures, slip-line field applied to the indentation zone instead of compressive fracture, and chip clogging involved during the bone drilling as demonstrated in earlier studies. Despite the deviations, the developed mechanistic models satisfactorily follow the trends of the thrust forces and torques experienced during bone drilling. The outcomes can be used to practice the bone drilling procedure and monitor the effect of process parameters on thrust forces and torques in the in-silico environment before performing actual surgery.
- 1 June 2021
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 29 (25) , 4546-4556
Bone drilling simulation using Johnson-Cook model combined with Cowper-Symonds model validated with in-vitro experiments
The unrestrained thrust forces generated during bone drilling result in mechanical damages to the local host bone and lead to loosening of fixations. Even though Johnson-Cook model, Cowper-Symonds model, and Zerilli-Armstrong model consider the strain rate dependent on plastic curve, the predictability and suitability of the individual models restrict its applications. So, Johnson-Cook model combined with Cowper-Symonds model was developed, and bone drilling simulations were performed. It was found that the combined model predicted the thrust forces with a maximum error of 9.51%. The outcomes of the study can be used in the manual as well as robotic-assisted drilling operations.
- 1 June 2021
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 29 (25) , 4546-4556
Bone drilling simulation using Johnson-Cook model combined with Cowper-Symonds model validated with in-vitro experiments
The unrestrained thrust forces generated during bone drilling result in mechanical damages to the local host bone and lead to loosening of fixations. Even though Johnson-Cook model, Cowper-Symonds model, and Zerilli-Armstrong model consider the strain rate dependent on plastic curve, the predictability and suitability of the individual models restrict its applications. So, Johnson-Cook model combined with Cowper-Symonds model was developed, and bone drilling simulations were performed. It was found that the combined model predicted the thrust forces with a maximum error of 9.51%. The outcomes of the study can be used in the manual as well as robotic-assisted drilling operations.