ASAlexander Saunders

Alexander Saunders

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander Saunders has a total of 193 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ultracold neutron properties of the Eljen-299-02D deuterated scintillator

    by Z. Tang, E. B. Watkins, S. M. Clayton, S. A. Currie, D. E. Fellers, T. Hassan, D. E. Hooks, T. M. Ito, S. K. Lawrence, S. W. T. MacDonald, et al.

    In this paper, we report studies of the Fermi potential and loss per bounce of ultracold neutrons (UCNs) on a deuterated scintillator (Eljen-299-02D). These UCN properties of the scintillator enable its use in a wide variety of applications in fundamental neutron research.


  • Experimental observations of exploding bridgewire detonator function

    by L. Smilowitz, B. F. Henson, D. Remelius, P. Bowlan, N. Suvorova, J. Allison, D. Cardon, M. Freeman, F. Mariam, W. Meijer, et al.

    Exploding bridgewire detonators are an industry standard technology used for over 75 years and valued for their precise timing and safety characteristics. Despite widespread use, their functional mechanism remains controversial with both shock and non-shock mechanisms attributed. In this work, we reexamine the bridgewire detonator function with a suite of modern diagnostics and compare these observations with the existing literature. Traditional detonator observations consisted of voltage applied to the bridgewire and time dependent current, integral response measurements such as case motion, and more recently Schlieren imaging of the detonator surface. In this work, we add visible light emission, x-ray transmission, proton radiography, and temperature measurements during detonator function in addition to voltage, current, and function times. The addition of in situ observations of light emission, temperature, and density gives us new insight into the mechanisms of explosive bridgewire detonator function. We see a distinct separation in time, location, symmetry, and velocity of bridgewire output and detonation onset. During the time between bridgewire burst and the initiation of detonation, we observe a temperature ramp in the input pellet. In this paper, we present the suite of measurements and comparisons with the literature on integral response measurements.


  • Dark field proton radiography

    by M. S. Freeman, J. C. Allison, E. F. Aulwes, B. A. Broder, M. G. Davis, M. Espy, P. E. Magnelind, F. G. Mariam, L. I. Martinez, J. J. Medina, et al.

    A pre- and post-collimation scheme has been applied to high energy proton radiography to establish a dark field condition, which defaults to a state of no transmission until a scatterer is placed at the object plane. This technique, dark field proton radiography, provides two additional capabilities to a standard proton radiography setup. First, protons with a high degree of angular dispersion are removed from the beam, reducing the effects of chromatic aberrations and decreasing noise. Second, protons below the same threshold are removed from the beam downstream of the objects, effectively making the transmission highly sensitive to small amounts of scatter at the object plane. Initial results indicate that the system is highly sensitive to the presence of thinner materials and improves sensitivity to subtle areal density variations in thick objects.


  • Open Access

    A next-generation inverse-geometry spallation-driven ultracold neutron source

    by K. K. H. Leung, G. Muhrer, T. Hügle, T. M. Ito, E. M. Lutz, M. Makela, C. L. Morris, R. W. Pattie, A. Saunders, A. R. Young

    The physics model of a next-generation spallation-driven high-current ultracold neutron (UCN) source capable of delivering an extracted UCN rate of around an order of magnitude higher than the strongest proposed sources, and around three orders of magnitude higher than existing sources, is presented. This UCN-current-optimized source would dramatically improve cutting-edge UCN measurements that are currently statistically limited. A novel “Inverse Geometry” design is used with 40 l of superfluid 4 He (He-II), which acts as the converter of cold neutrons to UCNs, cooled with state-of-the-art subcooled cryogenic technology to ∼ 1.6 K . Our source design is optimized for a 100 W maximum heat load constraint on the He-II and its vessel. In this paper, we first explore modifying the Lujan Center Mark-3 target for UCN production as a benchmark. In our Inverse Geometry, the spallation target is wrapped symmetrically around the cryogenic UCN converter to permit raster scanning the proton beam over a relatively large volume of tungsten spallation target to reduce the demand on the cooling requirements, which makes it reasonable to assume that water edge-cooling only is sufficient. Our design is refined in several steps to reach a UCN production rate P UCN = 2.1 × 10 9 s − 1 under our other restriction of 1 MW maximum available proton beam power. We then study the effects of the He-II scattering kernel used as well as reductions in P UCN due to pressurization to reach P UCN = 1.8 × 10 9 s − 1 . Finally, we provide a design for the UCN extraction system that takes into account the required He-II heat transport properties and implementation of a He-II containment foil that allows UCN transmission. We estimate a total useful UCN current from our source of R use ≈ 5 × 10 8 s − 1 from an 18 cm diameter guide ∼ 5 m from the source. Under a conservative “no return” (or “single passage”) approximation, this rate can produce an extracted density of > 1 × 10 4 UCN cm − 3 in < 1000 l external experimental volumes with a 58 Ni ( 335 neV ) cutoff potential.


  • A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)

    by Kevin Ronald Kuk, UCN Collaboration, Christopher Cude-Woods, Claudio Rodrigo Chavez Blanco, Jin Ha Choi, Juan Cruz Estrada Vigil, Mark Hoffbauer, Mark Makela, Petra Merkel, Christopher Morris, et al.

    The U.S. Department of Energy's Office of Scientific and Technical Information


  • Cylindrical Driven Shocks in Ceria

    by M. S. Freeman, C. L. Rousculp, D. A. Fredenburg, J. T. Bradley, P. M. Donovan, J. T. Dunwoody, F. Fierro, J. R. Griego, J. C. Lamar, F. G. Mariam, et al.

    Shock compression of granular ceria (CeO 2 ) was studied in converging cylindrical geometry using LANL proton radiography, and driven by the Precision High Energy-Density Liner Implosion Experiment (PHELIX) magnetic implosion system. PHELIX delivered nearly 4 MA to a 1.25-mm thick liner-impactor to magnetically accelerate it to ~0.8-1.0 mm μs -1 . The impactor launched a shock in the cylindrical Al outer wall of the target assembly containing equiaxed, 0.63-μm-mean diameter ceria powder initially compacted to a static density of 3.95 or 4.03 g cm -3 . The cylindrically converging shock in the target was observed with a series of 21 proton-radiographic frames down the axis of the cylinder. Proton radiography was performed using a ×3 magnetic lens magnifier and a 7.5-mrad collimator. The proton radiographic views were transformed from transmission images to areal density images, for comparison to a model. Results indicate that significant energy was expended in compacting the porous CeO 2 , as the wave velocity markedly decreases during convergence, and a clear shock reflected from the axis was not observed. These observations are inconsistent with pre-shot modeling, and highlight the need for an improved understanding of the physics of compaction under non-ideal loading configurations.


  • Measurement of the neutron lifetime using a magneto-gravitational trap and in situ detection

    by R. W. Pattie, N. B. Callahan, C. Cude-Woods, E. R. Adamek, L. J. Broussard, S. M. Clayton, S. A. Currie, E. B. Dees, X. Ding, E. M. Engel, et al.

    How long does a neutron live?: Unlike the proton, whose lifetime is longer than the age of the universe, a free neutron decays with a lifetime of about 15 minutes. Measuring the exact lifetime of neutrons is surprisingly tricky; putting them in a container and monitoring their decay can lead to errors because some neutrons will be lost owing to interactions with the container walls. To overcome this problem, Pattie et al. measured the lifetime in a trap where ultracold polarized neutrons were levitated by magnetic fields, precluding interactions with the trap walls (see the Perspective by Mumm). This more precise determination of the neutron lifetime will aid our understanding of how the first nuclei formed after the Big Bang. Science , this issue p. 627 ; see also p. 605


  • Open Access

    Measurement of the neutron lifetime using an asymmetric magneto- gravitational trap and in situ detection

    by R. W. Pattie Jr., N. B. Callahan, C. Cude-Woods, E. R. Adamek, L. J. Broussard, S. M. Clayton, S. A. Currie, E. B. Dees, X. Ding, E. M. Engel, et al.

    The precise value of the mean neutron lifetime, $\tau_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $\tau_n$ measured by counting the decay rate of free neutrons in a beam (887.7 $\pm$ 2.2 s) and by counting surviving ultracold neutrons stored for different storage times in a material trap (878.5$\pm$0.8 s). The experiment described here eliminates loss mechanisms present in previous trap experiments by levitating polarized ultracold neutrons above the surface of an asymmetric storage trap using a repulsive magnetic field gradient so that the stored neutrons do not interact with material trap walls and neutrons in quasi-stable orbits rapidly exit the trap. As a result of this approach and the use of a new in situ neutron detector, the lifetime reported here (877.7 $\pm$ 0.7 (stat) +0.4/-0.2 (sys) s) is the first modern measurement of $\tau_n$ that does not require corrections larger than the quoted uncertainties.

  • Open Access

    Demonstration of a solid deuterium source of ultra-cold neutrons

    by A. Saunders, J. M. Anaya, T. J. Bowles, B. W. Filippone, P. Geltenbort, R. E. Hill, M. Hino, S. Hoedl, G. E. Hogan, T. M. Ito, et al.

    Ultra-cold neutrons (UCN), neutrons with energies low enough to be confined by the Fermi potential in material bottles, are playing an increasing role in measurements of fundamental properties of the neutron. The ability to manipulate UCN with material guides and bottles, magnetic fields, and gravity can lead to experiments with lower systematic errors than have been obtained in experiments with cold neutron beams. The UCN densities provided by existing reactor sources limit these experiments. The promise of much higher densities from solid deuterium sources has led to proposed facilities coupled to both reactor and spallation neutron sources. In this paper we report on the performance of a prototype spallation neutron-driven solid deuterium source. This source produced bottled UCN densities of 145 +/-7 UCN/cm3, about three times greater than the largest bottled UCN densities previously reported. These results indicate that a production UCN source with substantially higher densities should be possible.