YGYanjuan Geng

Yanjuan Geng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yanjuan Geng has a total of 82 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Progressive Tactile Perception and Peripheral Hemodynamic Responses Induced by LIFUS on Fingertip

    by Liuni Qin, Yinshen Huang, Jin Xie, Lili Niu, Laixin Huang, Fei Li, Shichun Bao, Guanglin Li, Yanjuan Geng

    Peripherally applied low-intensity focused ultrasound stimulation (LIFUS) has emerged as a new modality of tactile restoration recently. If repetitive LIFUS would cause perceptual adaptation, like transcutaneous electrical nerve stimulation (TENS) does, has been rarely investigated. To address this issue, 14 healthy volunteers received LIFUS-based fine tactile stimulation on their right index fingertip in this work. To evaluate their perceptual stability, both subjective perceptual ratings and peripheral local hemodynamic responses were deployed. The sensory-level TENS was also included for comparison. Our results showed that the LIFUS brought better perceptual acuity and perceptual stability than TENS in terms of subjective perception and judgement. Moreover, the LIFUS induced an increase of local blood perfusion volume (BPV) since stimulation onset, while the TENS caused a decrease of BPV, both followed by a slow rebound to the baseline. Notably, repetitive LIFUS didn’t cause obvious progressive decrease of BPV responses with increasing dose, i.e., temporal accumulation, whereas TENS did. These findings would facilitate the development of non-invasive sensory feedback technique in multiple human-machine interaction scenarios, and shed valuable insights on neuromodulation mechanisms of peripherally applied LIFUS.

  • Open Access

    Low-Intensity Focused Ultrasound Stimulation on Fingertip Can Evoke Fine Tactile Sensations and Different Local Hemodynamic Responses

    by Liuni Qin, Mingyang Dou, Lili Niu, Laixin Huang, Fei Li, Shichun Bao, Xinping Deng, Guanglin Li, Yanjuan Geng

    Low-intensity focused ultrasound stimulation (LIFUS) has been proved effective in eliciting vibrotactile in addition to warm, cold and nociceptive pain when applied to human peripheral endings. However, if it can evoke fine tactile sensations has been rarely investigated by far despite the importance of fine tactile feedback in motor control. To explore this issue, 14 healthy volunteers were recruited in this study. A psychophysical experiment was firstly conducted to determine the appropriate range of pulse repetition frequency (PRF) and acoustic intensity (AI). Then, participants were asked to perceive and discriminate different tactile stimulations under LIFUS, so as to evaluate if multiple fine tactile sensations could be reliably elicited by modulating the PRF and AI. For objective assessment, the local blood perfusion volume (BPV) response beneath stimulated fingertip was recorded and characterized. Our results showed that four types of tactile sensations, including tapping, vibrating, electrical, and pressure could be reliably elicited by modulating the PRF and AI within a specific range, and there was a significant impact of PRF and AI on both participants’ tactile discrimination and amplitude features of BPV response. This study would facilitate the application of LIFUS to some human-machine interaction scenarios, and shed valuable insights on the physiological mechanisms of peripherally applied ultrasound stimulation.


  • Open Access

    Characterizing upper limb motor dysfunction with temporal and spatial distribution of muscle synergy extracted from high-density surface electromyography

    by Haoshi Zhang, Boxing Peng, Ziyin Chen, Yinghu Peng, Xiaomeng Zhou, Yanjuan Geng, Guanglin Li

    Objective. To promote the development of objective and comprehensive motion function assessment for patients, based on high-density surface electromyography (HD-sEMG), this study investigates the temporal and spatial variations of neuromuscular activities related to upper limb motor dysfunction. Approach. Patients with unilateral upper limb motor dysfunction and healthy controls were enrolled in the study. HD-sEMG was collected from both arms while they were performing eight hand and wrist movements. Muscle synergies were extracted from the HD-sEMG. Symmetry of bilateral upper limb synergies and synergy differences between motions were proposed as spatial indicators to measure alterations in synergy spatial distribution. Additionally, as a temporal characteristic, the correlation of bilateral upper limb activation coefficient was proposed to describe the coordination control of the central nervous system. All temporal and spatial indicators were compared between patients and healthy subjects. Main results. The patients showed a significant decrease (p < 0.05) in the symmetry of bilateral upper limb synergy spatial distribution and correlation of bilateral upper limb activation coefficient. Patients with motor dysfunction also showed an increase in synergy similarity between motions, indicating altered spatial distribution of muscle synergies. Significance. These findings provide valuable insights into specific patterns associated with motor dysfunction, informing motor function assessment, and guiding targeted interventions and rehabilitation strategies for neurologically disordered patients.


  • A Transfer Learning Based Cross-Subject Generic Model for Continuous Estimation of Finger Joint Angles From a New User

    by Yucheng Long, Yanjuan Geng, Chenyun Dai, Guanglin Li

    Continuous estimation of finger joints based on surface electromyography (sEMG) has attracted much attention in the field of human-machine interface (HMI). A couple of deep learning models were proposed to estimate the finger joint angles for specific subject. When applied onto a new subject, however, the performance of the subject-specific model would degrade significantly due to the inter-subject differences. Therefore, a novel cross-subject generic (CSG) model was proposed in this study to estimate continuous kinematics of finger joints for new users. Firstly, a multi-subject model based on the LSTA-Conv network was built by using sEMG and finger joint angles data from multiple subjects. Then, the subjects adversarial knowledge (SAK) transfer learning strategy was adopted to calibrate the multi-subject model with the training data from a new user. With the updated model parameters and the testing data from the new user, multiple finger joint angles could be estimated afterwards. The overall performance of the CSG model for new users was validated on three public datasets from Ninapro. The results showed that the newly proposed CSG model significantly outperformed five subject-specific models and two transfer learning models in terms of Pearson correlation coefficient, root mean square error, and coefficient of determination. Comparison analysis showed that both the long short-term feature aggregation (LSTA) module and the SAK transfer learning strategy contributed to the CSG model. Moreover, increasing number of subjects in training set improved the generalization capability of the CSG model. The novel CSG model would facilitate the application of robotic hand control and other HMI settings.


  • Open Access

    Applying muscle synergy analysis to forearm high-density electromyography of healthy people

    by Yanjuan Geng, Ziyin Chen, Yang Zhao, Vincent C. K. Cheung, Guanglin Li

    Introduction: Muscle synergy is regarded as a motor control strategy deployed by the central nervous system (CNS). Clarifying the modulation of muscle synergies under different strength training modes is important for the rehabilitation of motor-impaired patients.Methods: To represent the subtle variation of neuromuscular activities from the smaller forearm muscles during wrist motion, we proposed to apply muscle synergy analysis to preprocessed high-density electromyographic data (HDEMG). Here, modulation of muscle synergies within and across the isometric and isotonic training modes for strengthening muscles across the wrist were investigated. Surface HDEMGs were recorded from healthy subjects (N = 10). Three different HDEMG electrode configurations were used for comparison and validation of the extracted muscle synergies. The cosine of principal angles (CPA) and the Euclidian distance (ED) between synergy vectors were used to evaluate the intra- and inter-mode similarity of muscle synergies. Then, how the activation coefficients modulate the excitation of specific synergy under each mode was examined by pattern recognition. Next, for a closer look at the mode-specific synergies and the synergies shared by the two training modes, k-means clustering was applied.Results: We observed high similarity of muscle synergies across different tasks within each training mode, but decreased similarity of muscle synergies across different training modes. Both intra- and intermode similarity of muscle synergies were consistently robust to electrode configurations regardless of the similarity metric used.Discussion: Overall, our findings suggest that applying muscle synergy analysis to HDEMG is feasible, and that the traditional muscle synergies defined by whole-muscle components may be broadened to include sub-muscle components represented by the HDEMG channels. This work may lead to an appropriate neuromuscular analysis method for motor function evaluation in clinical settings and provide valuable insights for the prescription of rehabilitation training therapies.


  • Open Access

    In-Situ Measuring sEMG and Muscle Shape Change With a Flexible and Stretchable Hybrid Sensor for Hand Gesture Recognition

    by Pingao Huang, Hui Wang, Yuan Wang, Yanjuan Geng, Wenlong Yu, Chao Gao, Zhiyuan Liu, Guanglin Li

    The accurate recognition of hand motion intentions is an essential prerequisite for efficient human-machine interaction (HMI) systems such as multifunctional prostheses and rehabilitation robots. Surface electromyography (sEMG) signals and muscle shape change (MSC) signals which are usually detected with different types of sensors have been used for human hand motion intention recognition. However, using different sensors to measure sEMG and MSC respectively, it would be inconvenient and add deploying difficulty for human-machine interaction systems. In this study, a novel flexible and stretchable sensor was fabricated with a nano gold conductive material, which could simultaneously sense both sEMG and MSC signals. Accordingly, a wireless signal acquisition device was developed to record both sEMG and MSC signals with the fabricated hybrid sensors. The performance of the proposed in-situ dual-mode signal measurement (IDSM) system was evaluated by the recording signal quality and the accuracy of hand gesture recognition. The results demonstrated that by using two pairs of the hybrid sensors, the proposed IDSM system could obtain two-channel sEMG at a noise level of about 0.89 μVrms and four-channel MSC with a resolution of about 0.1 Ω. For a recognition task of 11 classes of hand gestures, the results showed that only with two pairs of the hybrid sensors, the average accuracy over all the subjects was 95.6 ± 2.9%, which was about 7% higher than that with two-channel sEMG and six-channel accelerometer signals. These results suggest that the proposed IDSM method would be an efficient way to simplify the human-machine interaction system with fewer sensors for high recognition accuracy of hand motions.


  • Open Access

    Identifying oscillations under multi-site sensory stimulation for high-level peripheral nerve injured patients: a pilot study

    by Yanjuan Geng, Liuni Qin, Yongcheng Li, Zhebin Yu, Linling Li, Mojisola Grace Asogbon, Yang Zhan, Nan Yan, Xin Guo, Guanglin Li

    Objective. For high-level peripheral nerve injuryed (PNI) patients with severe sensory dysfunction of upper extremities, identifying the multi-site tactile stimulation is of great importance to provide neurorehabilitation with sensory feedback. In this pilot study, we showed the feasibility of identifying multi-site and multi-intensity tactile stimulation in terms of electroencephalography (EEG). Approach. Three high-level PNI patients and eight non-PNI participants were recruited in this study. Four different sites over the upper arm, forearm, thumb finger and little finger were randomly stimulated at two intensities (both sensory-level) based on the transcutaneous electrical nerve stimulation. Meanwhile, 64-channel EEG signals were recorded during the passive tactile sense stimulation on each side. Main results. The spatial-spectral distribution of brain oscillations underlying multi-site sensory stimulation showed dominant power attenuation over the somatosensory and prefrontal cortices in both alpha-band (8–12 Hz) and beta-band (13–30 Hz). But there was no significant difference among different stimulation sites in terms of the averaged power spectral density over the region of interest. By further identifying different stimulation sites using temporal-spectral features, we found the classification accuracies were all above 89% for the affected arm of PNI patients, comparable to that from their intact side and that from the non-PNI group. When the stimulation site-intensity combinations were treated as eight separate classes, the classification accuracies were ranging from 88.89% to 99.30% for the affected side of PNI subjects, similar to that from their non-affected side and that from the non-PNI group. Other performance metrics, including specificity, precision, and F1-score, also showed a sound identification performance for both PNI patients and non-PNI subjects. Significance. These results suggest that reliable brain oscillations could be evoked and identified well, even though induced tactile sense could not be discerned by the PNI patients. This study have implication for facilitating bidirectional neurorehabilitation systems with sensory feedback.


  • A CNN-Attention Network for Continuous Estimation of Finger Kinematics from Surface Electromyography

    by Yanjuan Geng, Zhebin Yu, Yucheng Long, Liuni Qin, Ziyin Chen, Yongcheng Li, Xin Guo, Guanglin Li

    Dexterous control of robotic hand driven by human motor intent has drawn a lot of attention in both industrial and rehabilitation scenarios. Providing simultaneous and proportional control has become a prevailing solution recently. Towards improving the finger kinematics estimation precision and reducing its computational cost, a convolution model with attention mechanism (CNN-Attention) was proposed in this study. For comparison purpose, two previously used deep learning models, the long short-term memory (LSTM) and the Sparse Pseudo-input Gaussian processes (SPGP) were also included. By using surface electromyography (sEMG) and kinematic signals corresponding to six hand grasp movements, the estimation performance of each of the three models was evaluated with three measures, Pearson Correlation Coefficient (CC), Root Mean Square Error (RMSE), and coefficient of determination (R2) between real and estimated joint angles. The results demonstrated that the proposed CNN-Attention model outperformed LSTM and SPGP significantly ( p -value<0.05), with an average value of CC, RMSE, and R2, 0.87, 9.65 degrees, and 0.73, respectively. Also, the CNN-Attention model is more stable and versatile over various subjects and joint angles in comparison to other models. Additionally, the computational time to build a CNN-Attention was obviously shorter than that to train a LSTM model (43.00 ± 4.25 min vs. 73.40 ± 5.81 min). These findings suggest that the CNN-Attention would be a promising model for continuous estimation of hand movements in the human-machine interaction and cooperation.