Bharti Kataria
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bharti Kataria has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Örjan Smedby
Department of Biomedical Engineering and Health Systems (MTH), KTH Royal Institute of Technology, Stockholm, Sweden
7 shared publications - Michael Sandborg
Department of Health, Medicine and Caring Sciences, Linköping University , SE-581 83 Linköping
6 shared publications - Anders Persson
Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
4 shared publications - Jonas Nilsson Althén
Department of Health , Medicine & Caring Sciences SE-581 83 Linköping , Sweden
3 shared publications Michael Sandborg
Department of Health, Medicine & Caring Sciences, Linköping University, Linköping, Sweden
3 shared publications- Anders Lindgaard Andersen
Department of Anesthesia and Intensive Care, Växjö County Hospital, Växjö, Sweden
2 shared publications
Latest Publications
- Open Access
- 14 May 2025
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 7 (5) , e1269
Determination of Glomerular Filtration Rate After Contrast-Enhanced CT Among Critically Ill Patients: Support for a New Procedure
OBJECTIVES: To measure glomerular filtration rate using iohexol plasma clearance (mGFRiohexol) in critically ill patients using the high doses of iohexol administered at CT and to evaluate its agreements with urinary creatinine clearance (uClcr) and estimated glomerular filtration rates (eGFRs), calculated from plasma concentrations of creatinine (eGFRcr) and cystatin C (eGFRcys). DESIGN: Prospective observational cohort study. SETTING: ICUs across Southeast Sweden. PATIENTS: Critically ill adult patients. INTERVENTIONS AND MEASUREMENTS: Twenty-six ICU patients were given high doses of iohexol (range, 27–140 mL) for contrast-enhanced CT, whereafter blood samples were taken in the elimination phase for determination of mGFRiohexol. Plasma iohexol concentrations were determined by high-performance liquid chromatography and mGFRiohexol was calculated. Standard dose (5 mL) of iohexol was administered the following days to compare low-dose clearance results with the high-dose clearance results. Six-hour uClcr was performed four times a day and averaged. MAIN RESULTS: Mean ± sd mGFRiohexol after CT was 77.4 ± 38.1 mL/min (n = 26), and uClcr was 97.3 ± 58.2 mL/min (n = 25) in the critically ill patients. There was a strong positive correlation between mGFRiohexol determined with high and low doses of iohexol in patients with normal or high mGFRiohexol (coefficient of determination [R 2] = 0.88; p < 0.001) and between mGFRiohexol and uClcr (R 2 = 0.87; p < 0.001). eGFRcr overestimated mGFRiohexol and eGFRcys underestimated mGFRiohexol. CONCLUSIONS: mGFRiohexol after contrast-enhanced CT compares well with mGFRiohexol after standard low-dose iohexol respectively uClcr. Over- and underestimation of mGFRiohexol by eGFRcr and eGFRcys is probably explained by increased tubular secretion of creatinine and increased production of cystatin C in intensive care patients.
- 14 May 2025
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 7 (5) , e1269
Open AccessDetermination of Glomerular Filtration Rate After Contrast-Enhanced CT Among Critically Ill Patients: Support for a New Procedure
OBJECTIVES: To measure glomerular filtration rate using iohexol plasma clearance (mGFRiohexol) in critically ill patients using the high doses of iohexol administered at CT and to evaluate its agreements with urinary creatinine clearance (uClcr) and estimated glomerular filtration rates (eGFRs), calculated from plasma concentrations of creatinine (eGFRcr) and cystatin C (eGFRcys). DESIGN: Prospective observational cohort study. SETTING: ICUs across Southeast Sweden. PATIENTS: Critically ill adult patients. INTERVENTIONS AND MEASUREMENTS: Twenty-six ICU patients were given high doses of iohexol (range, 27–140 mL) for contrast-enhanced CT, whereafter blood samples were taken in the elimination phase for determination of mGFRiohexol. Plasma iohexol concentrations were determined by high-performance liquid chromatography and mGFRiohexol was calculated. Standard dose (5 mL) of iohexol was administered the following days to compare low-dose clearance results with the high-dose clearance results. Six-hour uClcr was performed four times a day and averaged. MAIN RESULTS: Mean ± sd mGFRiohexol after CT was 77.4 ± 38.1 mL/min (n = 26), and uClcr was 97.3 ± 58.2 mL/min (n = 25) in the critically ill patients. There was a strong positive correlation between mGFRiohexol determined with high and low doses of iohexol in patients with normal or high mGFRiohexol (coefficient of determination [R 2] = 0.88; p < 0.001) and between mGFRiohexol and uClcr (R 2 = 0.87; p < 0.001). eGFRcr overestimated mGFRiohexol and eGFRcys underestimated mGFRiohexol. CONCLUSIONS: mGFRiohexol after contrast-enhanced CT compares well with mGFRiohexol after standard low-dose iohexol respectively uClcr. Over- and underestimation of mGFRiohexol by eGFRcr and eGFRcys is probably explained by increased tubular secretion of creatinine and increased production of cystatin C in intensive care patients.
- Open Access
- 7 October 2024
- Published by Elsevier in Radiography
- Vol. 30 (6) , 1563-1571
Image quality assessments in abdominal CT: Relative importance of dose, iterative reconstruction strength and slice thickness
- 7 October 2024
- Published by Elsevier in Radiography
- Vol. 30 (6) , 1563-1571
Open AccessImage quality assessments in abdominal CT: Relative importance of dose, iterative reconstruction strength and slice thickness
- Open Access
- 17 February 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (5) , 504-514
Image quality in CT thorax: effect of altering reconstruction algorithm and tube load
Non-linear properties of iterative reconstruction (IR) algorithms can alter image texture. We evaluated the effect of a model-based IR algorithm (advanced modelled iterative reconstruction; ADMIRE) and dose on computed tomography thorax image quality. Dual-source scanner data were acquired at 20, 45 and 65 reference mAs in 20 patients. Images reconstructed with filtered back projection (FBP) and ADMIRE Strengths 3–5 were assessed independently by six radiologists and analysed using an ordinal logistic regression model. For all image criteria studied, the effects of tube load 20 mAs and all ADMIRE strengths were significant (p < 0.001) when compared to reference categories 65 mAs and FBP. Increase in tube load from 45 to 65 mAs showed image quality improvement in three of six criteria. Replacing FBP with ADMIRE significantly improves perceived image quality for all criteria studied, potentially permitting a dose reduction of almost 70% without loss in image quality.
- 17 February 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (5) , 504-514
Open AccessImage quality in CT thorax: effect of altering reconstruction algorithm and tube load
Non-linear properties of iterative reconstruction (IR) algorithms can alter image texture. We evaluated the effect of a model-based IR algorithm (advanced modelled iterative reconstruction; ADMIRE) and dose on computed tomography thorax image quality. Dual-source scanner data were acquired at 20, 45 and 65 reference mAs in 20 patients. Images reconstructed with filtered back projection (FBP) and ADMIRE Strengths 3–5 were assessed independently by six radiologists and analysed using an ordinal logistic regression model. For all image criteria studied, the effects of tube load 20 mAs and all ADMIRE strengths were significant (p < 0.001) when compared to reference categories 65 mAs and FBP. Increase in tube load from 45 to 65 mAs showed image quality improvement in three of six criteria. Replacing FBP with ADMIRE significantly improves perceived image quality for all criteria studied, potentially permitting a dose reduction of almost 70% without loss in image quality.
- Open Access
Determination of glomerular filtration rate, a spin off after contrast-enhanced computed tomography among critically ill patients – proof of concept
Background: Recently, Gong et al. (Gong et al. 2022) showed, in nine heathy subjects, that plasma clearance of high doses of iohexol given as contrast enhanced computed tomography (CT) could be used for determination of glomerular filtration rate (GFR). We utilized high doses of iohexol from angiographic or other contrast enhanced CT given to critical ill patients for calculation of GFR iohexol and compared these data with standard low dose iohexol GFR determinations. Method: Patients at intensive care units (ICUs) in Southeast Sweden intended for radiographic investigations that included injection of 45-120 ml of iohexol (Omnipaque) were included, and the concentration of iohexol in plasma was measured by HPLC. Iohexol clearance was calculated by the method of Bröchner-Mortensen. The following days was iohexol clearance determined using the standard low dose of 5 mL of iohexol. Sixteen patients admitted to ICUs were included in this pilot study. Results: GFR after high dosing of iohexol at contrast enhanced CT could be measured for all sixteen critically ill patients. Patients with normal or increased renal function had neglectable iohexol concentrations the day following the CT scan. There was excellent correlation between GFR determination with high and standard low iohexol dosing among these 6 patients. Ten patients had decreased renal function and delayed elimination of iohexol, thus was not GFR measurement with low dose iohexol possible to analyse the day after CT scan with high dose iohexol. Conclusion: This pilot study showed that GFR can be measured after high doses of iohexol at enhanced CT and compare well with the standard low dose of iohexol clearance determinations.
Open AccessDetermination of glomerular filtration rate, a spin off after contrast-enhanced computed tomography among critically ill patients – proof of concept
Background: Recently, Gong et al. (Gong et al. 2022) showed, in nine heathy subjects, that plasma clearance of high doses of iohexol given as contrast enhanced computed tomography (CT) could be used for determination of glomerular filtration rate (GFR). We utilized high doses of iohexol from angiographic or other contrast enhanced CT given to critical ill patients for calculation of GFR iohexol and compared these data with standard low dose iohexol GFR determinations. Method: Patients at intensive care units (ICUs) in Southeast Sweden intended for radiographic investigations that included injection of 45-120 ml of iohexol (Omnipaque) were included, and the concentration of iohexol in plasma was measured by HPLC. Iohexol clearance was calculated by the method of Bröchner-Mortensen. The following days was iohexol clearance determined using the standard low dose of 5 mL of iohexol. Sixteen patients admitted to ICUs were included in this pilot study. Results: GFR after high dosing of iohexol at contrast enhanced CT could be measured for all sixteen critically ill patients. Patients with normal or increased renal function had neglectable iohexol concentrations the day following the CT scan. There was excellent correlation between GFR determination with high and standard low iohexol dosing among these 6 patients. Ten patients had decreased renal function and delayed elimination of iohexol, thus was not GFR measurement with low dose iohexol possible to analyse the day after CT scan with high dose iohexol. Conclusion: This pilot study showed that GFR can be measured after high doses of iohexol at enhanced CT and compare well with the standard low dose of iohexol clearance determinations.
- Open Access
- 6 May 2023
- Published by Elsevier in European Journal of Radiology Open
- Vol. 10, 100490
Learning effects in visual grading assessment of model-based reconstruction algorithms in abdominal Computed Tomography
- 6 May 2023
- Published by Elsevier in European Journal of Radiology Open
- Vol. 10, 100490
Open AccessLearning effects in visual grading assessment of model-based reconstruction algorithms in abdominal Computed Tomography
- Open Access
- 16 August 2022
- Published by Springer Nature in Research Square
Learning effects in visual grading assessment of new reconstruction algorithms in abdominal Computed Tomography
ObjectivesImages reconstructed with higher strengths of iterative reconstruction algorithms impair radiologists’ subjective perception and diagnostic performance due to changes in the amplitude of different spatial frequencies of noise. The hypothesis was that there was a change in radiologists´ assessments towards a more positive attitude to the higher strengths of Advanced modeled iterative reconstruction algorithm (ADMIRE). Can radiologists learn to adapt to the unusual appearance of images produced by higher strengths of ADMIRE?MethodsThe present study is based on two ethical board, previously published, studies that evaluated the performance of ADMIRE in non-contrast and contrast-enhanced abdominal CT. Images from 25 (first material) and 50 (second material) clinical examinations, were reconstructed with ADMIRE strengths 3, 5 and filtered back projection (FBP). These images were assessed by local radiologists using image criteria obtained from the European guidelines for quality criteria in CT. To ascertain if there was a learning effect as the reviews progressed, results from these two studies were used in the new analyses of existing data by introducing a time variable in the mixed-effects ordinal logistic regression model.ResultsFor the highest strength (5) of the ADMIRE algorithm, the significant negative attitude for both liver parenchyma and overall image quality for diagnostic purposes, at the beginning of the reviews was strengthened during the progress of the reviews in both materials. For ADMIRE strength 3, an early positive attitude for the algorithm was perceived with no significant change over time for majority of the criteria except for one criterion, i.e., the overall image quality, where a significant negative trend over time was seen in the second material. ConclusionsAs the reviews in both materials progressed, an increasing dislike for ADMIRE 5 images was apparent for at least two image criteria. In the time perspective of weeks or months, no learning effect towards accepting the new algorithm could be demonstrated.
- 16 August 2022
- Published by Springer Nature in Research Square
Open AccessLearning effects in visual grading assessment of new reconstruction algorithms in abdominal Computed Tomography
ObjectivesImages reconstructed with higher strengths of iterative reconstruction algorithms impair radiologists’ subjective perception and diagnostic performance due to changes in the amplitude of different spatial frequencies of noise. The hypothesis was that there was a change in radiologists´ assessments towards a more positive attitude to the higher strengths of Advanced modeled iterative reconstruction algorithm (ADMIRE). Can radiologists learn to adapt to the unusual appearance of images produced by higher strengths of ADMIRE?MethodsThe present study is based on two ethical board, previously published, studies that evaluated the performance of ADMIRE in non-contrast and contrast-enhanced abdominal CT. Images from 25 (first material) and 50 (second material) clinical examinations, were reconstructed with ADMIRE strengths 3, 5 and filtered back projection (FBP). These images were assessed by local radiologists using image criteria obtained from the European guidelines for quality criteria in CT. To ascertain if there was a learning effect as the reviews progressed, results from these two studies were used in the new analyses of existing data by introducing a time variable in the mixed-effects ordinal logistic regression model.ResultsFor the highest strength (5) of the ADMIRE algorithm, the significant negative attitude for both liver parenchyma and overall image quality for diagnostic purposes, at the beginning of the reviews was strengthened during the progress of the reviews in both materials. For ADMIRE strength 3, an early positive attitude for the algorithm was perceived with no significant change over time for majority of the criteria except for one criterion, i.e., the overall image quality, where a significant negative trend over time was seen in the second material. ConclusionsAs the reviews in both materials progressed, an increasing dislike for ADMIRE 5 images was apparent for at least two image criteria. In the time perspective of weeks or months, no learning effect towards accepting the new algorithm could be demonstrated.
- Open Access
- 29 March 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (3-4) , 177-187
IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW
Traditional filtered back projection (FBP) reconstruction methods have served the computed tomography (CT) community well for over 40 years. With the increased use of CT during the last decades, efforts to minimise patient exposure, while maintaining sufficient or improved image quality, have led to the development of model-based iterative reconstruction (MBIR) algorithms from several vendors. The usefulness of the advanced modeled iterative reconstruction (ADMIRE) (Siemens Healthineers) MBIR in abdominal CT is reviewed and its noise suppression and/or dose reduction possibilities explored. Quantitative and qualitative methods with phantom and human subjects were used. Assessment of the quality of phantom images will not always correlate positively with those of patient images, particularly at the higher strength of the ADMIRE algorithm. With few exceptions, ADMIRE Strength 3 typically allows for substantial noise reduction compared to FBP and hence to significant (≈30%) patient dose reductions. The size of the dose reductions depends on the diagnostic task.
- 29 March 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (3-4) , 177-187
Open AccessIMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW
Traditional filtered back projection (FBP) reconstruction methods have served the computed tomography (CT) community well for over 40 years. With the increased use of CT during the last decades, efforts to minimise patient exposure, while maintaining sufficient or improved image quality, have led to the development of model-based iterative reconstruction (MBIR) algorithms from several vendors. The usefulness of the advanced modeled iterative reconstruction (ADMIRE) (Siemens Healthineers) MBIR in abdominal CT is reviewed and its noise suppression and/or dose reduction possibilities explored. Quantitative and qualitative methods with phantom and human subjects were used. Assessment of the quality of phantom images will not always correlate positively with those of patient images, particularly at the higher strength of the ADMIRE algorithm. With few exceptions, ADMIRE Strength 3 typically allows for substantial noise reduction compared to FBP and hence to significant (≈30%) patient dose reductions. The size of the dose reductions depends on the diagnostic task.
- Open Access
- 1 January 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 122, 108703
Assessment of image quality in abdominal computed tomography: Effect of model-based iterative reconstruction, multi-planar reconstruction and slice thickness on potential dose reduction
- 1 January 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 122, 108703
Open AccessAssessment of image quality in abdominal computed tomography: Effect of model-based iterative reconstruction, multi-planar reconstruction and slice thickness on potential dose reduction
- Open Access
- 7 November 2019
- Published by Linkoping University Electronic Press
Visual grading evaluation of reconstruction methods and dose optimisation in abdominal Computed Tomography
Since its introduction in the 1970’s CT has emerged as a modality of choice because of its high sensitivity in producing accurate diagnostic images. A third of all Computed Tomography (CT) examinat ...
- 7 November 2019
- Published by Linkoping University Electronic Press
Open AccessVisual grading evaluation of reconstruction methods and dose optimisation in abdominal Computed Tomography
Since its introduction in the 1970’s CT has emerged as a modality of choice because of its high sensitivity in producing accurate diagnostic images. A third of all Computed Tomography (CT) examinat ...
- Open Access
- 9 August 2019
- Published by Springer Nature in BMC Medical Imaging
- Vol. 19 (1) , 1-9
Image quality and pathology assessment in CT Urography: when is the low-dose series sufficient?
Our aim was to compare CT images from native, nephrographic and excretory phases using image quality criteria as well as the detection of positive pathological findings in CT Urography, to explore if the radiation burden to the younger group of patients or patients with negative outcomes can be reduced. This is a retrospective study of 40 patients who underwent a CT Urography examination on a 192-slice dual source scanner. Image quality was assessed for four specific renal image criteria from the European guidelines, together with pathological assessment in three categories: renal, other abdominal, and incidental findings without clinical significance. Each phase was assessed individually by three radiologists with varying experience using a graded scale. Certainty scores were derived based on the graded assessments. Statistical analysis was performed using visual grading regression (VGR). The limit for significance was set at p = 0.05. For visual reproduction of the renal parenchyma and renal arteries, the image quality was judged better for the nephrogram phase (p < 0.001), whereas renal pelvis/calyces and proximal ureters were better reproduced in the excretory phase compared to the native phase (p < 0.001). Similarly, significantly higher certainty scores were obtained in the nephrogram phase for renal parenchyma and renal arteries, but in the excretory phase for renal pelvis/calyxes and proximal ureters. Assessment of pathology in the three categories showed no statistically significant differences between the three phases. Certainty scores for assessment of pathology, however, showed a significantly higher certainty for renal pathology when comparing the native phase to nephrogram and excretory phase and a significantly higher score for nephrographic phase but only for incidental findings. Visualisation of renal anatomy was as expected with each post-contrast phase showing favourable scores compared to the native phase. No statistically significant differences in the assessment of pathology were found between the three phases. The low-dose CT (LDCT) seems to be sufficient in differentiating between normal and pathological examinations. To reduce the radiation burden in certain patient groups, the LDCT could be considered a suitable alternative as a first line imaging method. However, radiologists should be aware of its limitations.
- 9 August 2019
- Published by Springer Nature in BMC Medical Imaging
- Vol. 19 (1) , 1-9
Open AccessImage quality and pathology assessment in CT Urography: when is the low-dose series sufficient?
Our aim was to compare CT images from native, nephrographic and excretory phases using image quality criteria as well as the detection of positive pathological findings in CT Urography, to explore if the radiation burden to the younger group of patients or patients with negative outcomes can be reduced. This is a retrospective study of 40 patients who underwent a CT Urography examination on a 192-slice dual source scanner. Image quality was assessed for four specific renal image criteria from the European guidelines, together with pathological assessment in three categories: renal, other abdominal, and incidental findings without clinical significance. Each phase was assessed individually by three radiologists with varying experience using a graded scale. Certainty scores were derived based on the graded assessments. Statistical analysis was performed using visual grading regression (VGR). The limit for significance was set at p = 0.05. For visual reproduction of the renal parenchyma and renal arteries, the image quality was judged better for the nephrogram phase (p < 0.001), whereas renal pelvis/calyces and proximal ureters were better reproduced in the excretory phase compared to the native phase (p < 0.001). Similarly, significantly higher certainty scores were obtained in the nephrogram phase for renal parenchyma and renal arteries, but in the excretory phase for renal pelvis/calyxes and proximal ureters. Assessment of pathology in the three categories showed no statistically significant differences between the three phases. Certainty scores for assessment of pathology, however, showed a significantly higher certainty for renal pathology when comparing the native phase to nephrogram and excretory phase and a significantly higher score for nephrographic phase but only for incidental findings. Visualisation of renal anatomy was as expected with each post-contrast phase showing favourable scores compared to the native phase. No statistically significant differences in the assessment of pathology were found between the three phases. The low-dose CT (LDCT) seems to be sufficient in differentiating between normal and pathological examinations. To reduce the radiation burden in certain patient groups, the LDCT could be considered a suitable alternative as a first line imaging method. However, radiologists should be aware of its limitations.